Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Generation of intense isolated sub-40-as pulses from a coherent superposition state by quantum path control in the multicycle regime

We theoretically investigate high-order harmonic generation and attosecond pulses by numerically solving the three-dimensional time-dependent Schroedinger equation from a helium ion in a two-color laser field, which is synthesized by adding a 1600-nm laser pulse to a multicycle 800-nm laser pulse. The numerical results show that the short quantum path selection and broadband continuum spectra are achieved by adjusting the relative phase between two laser pulses, and isolated attosecond pulses can be generated successfully. Compared with the case of He{sup +} ions from the 1s ground state, the emission efficiency of the continuous harmonics and the intensity of the isolated attosecond pulse are enhanced approximately thirteen orders of magnitude by preparing He{sup +} ions in a coherent superposition of the states 1s and 2s. Furthermore, the bandwidth of the continuum spectrum is further broadened by increasing the intensity of the 1600-nm laser pulse, and an intense 38-as isolated pulse with a bandwidth of 109 eV is straightforwardly obtained.

74 ATOMIC AND MOLECULAR PHYSICS↗

Generating Quasi-Single-Cycle Relativistic Laser Pulses by Laser-Foil Interaction

A scheme for producing nearly single-cycle relativistic laser pulses is proposed. When a laser pulse interacts with an overdense thin foil, because of self-consistent nonlinear modulation, the latter will be more transparent to the more intense part of the laser, so that a transmitted pulse can be much shorter than the incident pulse. Using two-dimensional particle-in-cell simulation and analytical modeling, it is found that a transmitted pulse of duration 4 fs and peak intensity 3x10{sup 20} W/cm{sup 2} can be generated from a circularly polarized laser pulse. The intensity of the resulting pulse is only limited by that of the incident pulse, since this scheme involves only laser-plasma interaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion flux and ion distribution function measurements in synchronously pulsed inductively coupled plasmas

Changes in the ion flux and the time-averaged ion distribution functions are reported for pulsed, inductively coupled RF plasmas (ICPs) operated over a range of duty cycles. For helium and argon plasmas, the ion flux increases rapidly after the start of the RF pulse and after about 50 {mu}s reaches the same steady state value as that in continuous ICPs. Therefore, when the plasma is pulsed at 1 kHz, the ion flux during the pulse has a value that is almost independent of the duty cycle. By contrast, in molecular electronegative chlorine/chlorosilane plasmas, the ion flux during the pulse reaches a steady state value that depends strongly on the duty cycle. This is because both the plasma chemistry and the electronegativity depend on the duty cycle. As a result, the ion flux is 15 times smaller in a pulsed 10% duty cycle plasma than in the continuous wave (CW) plasma. The consequence is that for a given synchronous RF biasing of a wafer-chuck, the ion energy is much higher in the pulsed plasma than it is in the CW plasma of chlorine/chlorosilane. Under these conditions, the wafer is bombarded by a low flux of very energetic ions, very much as it would in a low density, capacitively coupled plasma. Therefore, one can extend the operating range of ICPs through synchronous pulsing of the inductive excitation and capacitive chuck-bias, offering new means by which to control plasma etching.

74 ATOMIC AND MOLECULAR PHYSICS↗

Absolute and relative dose measurements with Gafchromic trade mark sign EBT film for high energy electron beams with different doses per pulse

The authors have evaluated the accuracy, in absolute and relative dose measurements, of the Gafchromic trade mark sign EBT film in pulsed high-energy electron beams. Typically, the electron beams used in radiotherapy have a dose-per-pulse value of less than 0.1 mGy/pulse. However, very high dose-per-pulse electron beams are employed in certain linear accelerators dedicated to intraoperatory radiation therapy (IORT). In this study, the absorbed dose measurements with Gafchromic trade mark sign EBT in both low (less than 0.3 mGy per pulse) and high (30 and 70 mGy per pulse) dose-per-pulse electron beams were compared with ferrous sulfate chemical Fricke dosimetry (operated by the Italian Primary Standard Dosimetry Laboratory), a method independent of the dose per pulse. A summary of Gafchromic trade mark sign EBT in relative and absolute beam output determination is reported. This study demonstrates the independence of Gafchromic trade mark sign EBT absorption as a function of dose per pulse at different dose levels. A good agreement (within 3%) was found with Fricke dosimeters for plane-base IORT applicators. Comparison with a diode detector is presented for relative dose measurements, showing acceptable agreement both in the steep dose falloff zone and in the homogeneous dose region. This work also provides experimental values for recombination correction factor (K{sub sat}) of a Roos (plane parallel) ionization chamber calculated on the basis of theoretical models for charge recombination.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cross-phase-modulation-induced temporal reflection and waveguiding of optical pulses

Cross-phase modulation (XPM) is commonly viewed as a nonlinear process that chirps a probe pulse and modifies its spectrum when an intense pump pulse overlaps with it. Here we present an alternative view of XPM in which the pump pulse creates a moving refractive-index boundary that splits the probe pulse into two parts with distinct optical spectra through temporal reflection and refraction inside a dispersive nonlinear medium. The probe even undergoes a temporal version of total internal reflection for sufficiently intense pump pulses, a phenomenon that can be exploited for making temporal waveguides. In this paper we investigate the practical conditions under which XPM can be exploited for temporal reflection and waveguiding. The width and shape of pump pulses as well as the nature of medium dispersion at the pump and probe wavelength (normal versus anomalous) play important roles. A super-Gaussian shape of pump pulses is particularly helpful because of its relatively sharp edges. When the pump wavelength lies in the anomalous-dispersion regime, the pump pulse can form a soliton,whose unique properties can be exploited to advantage. We also discuss a potential application of XPM-induced temporal waveguides for compensating timing jitter.

36 MATERIALS SCIENCE↗

SIMULTANEOUS OBSERVATIONS OF GIANT PULSES FROM PULSAR PSR B0031-07 AT 38 AND 74 MHz

The first station of the Long Wavelength Array was used to study PSR B0031-07 with simultaneous observations at 38 and 74 MHz. We found that 158 (0.35%) of the observed pulses at 38 MHz and 221 (0.49%) of the observed pulses at 74 MHz qualified as giant pulses (GPs) in a total of 12 hr of observations. GPs are defined as having flux densities of a factor of ≥90 times that of an average pulse (AP) at 38 MHz and ≥80 times that of an AP at 74 MHz. The cumulative distribution of pulse strength follows a power law, with an index of −4.2 at 38 MHz and −4.9 at 74 MHz. This distribution has a much more gradual slope than would be expected if observing the tail of a Gaussian distribution of normal pulses. The dispersion measure (DM) value which resulted in the largest signal to noise for dedispersed pulses was DM = 10.9 pc cm{sup −3}. No other transient pulses were detected in the data in the wide DM range from 1 to 5000 pc cm{sup −3}. There were 12 GPs detected within the same period from both 38 and 74 MHz, meaning that the majority of them are not generated in a wide band.

79 ASTRONOMY AND ASTROPHYSICS↗

Descattering of giant pulses in PSR B1957+20

The interstellar medium scatters radio waves, which causes pulsars to scintillate. For intrinsically short bursts of emission, the observed signal should be a direct measurement of the impulse response function. We show that this is indeed the case for giant pulses from PSR B1957+20: from baseband observations at 327 MHz, we demonstrate that the observed voltages of a bright pulse allow one to coherently descatter nearby pulses. We find that while the scattering timescale is 12.2 μs, the power in the descattered pulses is concentrated within a span almost two orders of magnitude shorter, of ≲200 ns. This sets an upper limit to the intrinsic duration of the giant pulses. We verify that the response inferred from the giant pulses is consistent with the scintillation pattern obtained by folding the regular pulsed emission, and that it decorrelates on the same timescale, of 84 s. In principle, with large sets of giant pulses, it should be possible to constrain the structure of the scattering screen much more directly than with other current techniques, such as holography on the dynamic spectrum and cyclic spectroscopy.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal Acoustic Sensor for High Pulse Energy X-ray FEL Beams

The pulse energy density of X-ray FELs will saturate or destroy conventional X-ray diagnostics, and the use of large beam attenuation will result in a beam that is dominated by harmonics. We present preliminary results at the LCLS from a pulse energy detector based on the thermal acoustic effect. In this type of detector an X-ray resistant material (boron carbide in this system) intercepts the beam. The pulse heating of the target material produces an acoustic pulse that can be detected with high frequency microphones to produce a signal that is linear in the absorbed energy. The thermal acoustic detector is designed to provide first- and second-order calorimetric measurement of X-ray FEL pulse energy. The first-order calorimetry is a direct temperature measurement of a target designed to absorb all or most of the FEL pulse power with minimal heat leak. The second-order measurement detects the vibration caused by the rapid thermoelastic expansion of the target material each time it absorbs a photon pulse. Both the temperature change and the amplitude of the acoustic signal are directly related to the photon pulse energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Temporal laser pulse shaping for RF photocathode guns : the cheap and easy way using UV birefringent crystals.

We report experimental investigations into a new technique for achieving temporal laser pulse shaping for RF photocathode gun applications using inexpensive UV birefringent crystals. Exploiting the group velocity mismatch between the two different polarizations of a birefringent crystal, a stack of UV pulses can be assembled into the desired temporal pulse shape. The scheme is capable of generating a variety of temporal pulse shapes including: (i) flat-top pulses with fast rise-time and variable pulse duration. (ii) microbunch trains, and (iii) ramped pulse generation. We will consider two applications for beam generation at the Argonne Wakefield Accelerator (AWA) including a flat-top laser pulse for low emittance production and matched bunch length for enhanced transformer ratio production. Streak camera measurements of the temporal profiles generated with a 2-crystal set and a 4-crystal set are presented.

43 PARTICLE ACCELERATORS↗

Orientation-dependent enhanced ionization in acetylene revealed by ultrafast cross-polarized pulse pairs

We investigate the orientation dependence of enhanced ionization (EI) during strong-field-driven nuclear motion in acetylene (C 2 ⁢H 2 ). Here, we both initiate and probe molecular dynamics in acetylene with intense 6-fs cross-polarized pulse pairs, separated by a variable delay. Following multiple ionization by the first pulse, acetylene undergoes simultaneous elongation of the carbon-carbon and carbon-hydrogen bonds, enabling further ionization by the second pulse and the formation of a very highly charged state, [C 2 ⁢H 2 ] 6+ . At small interpulse delays (< 20 fs), this enhancement occurs when the molecule is aligned to the probe pulse. Conversely, at large delays (> 40 fs), formation of [C 2 ⁢H 2 ] 6+ occurs when the molecule is aligned to the pump pulse. By analyzing the polarization and time dependence of sequentially ionized [C 2 ⁢H 2 ] 6+ , we resolve two transient alignments that both contribute to a large increase in the multiple ionization yield. In conclusion, this cross-polarized pulse pair scheme uniquely enables selective probing of deeply bound orbitals, providing new insights on orientation-dependent EI in highly charged hydrocarbons.

Atomic & molecular clusters↗

Efficient 15 N hyperpolarization of [ 15 N 3 ]metronidazole antibiotic via spin-relayed pulsed SABRE-SHEATH

Signal Amplification by Reversible Exchange in SHield Enables Alignment Transfer to Heteronuclei (SABRE-SHEATH) is an NMR hyperpolarization technique that relies of the simultaneous exchange of parahydrogen and a to-be-hyperpolarized molecule on the metal center of a polarization-transfer catalyst in a microtesla magnetic field. Until recently, this method has been understood to perform hyperpolarization by establishing level anti-crossings between the nuclear spins of the parahydrogen derived hydrides (acting as a source of hyperpolarization) and those of the substrate. Recently, the application of highly non-intuitive pulse sequences (comprising pulses of microtesla DC fields) was predicted to hyperpolarize nuclear spins more efficiently than the canonical (static-field) SABRE-SHEATH approach. Here we show that by employing a basic “on-off” pulse sequence of rectangular microtesla pulses, it is possible to improve the hyperpolarization efficiency for SABRE-SHEATH of [ 15 N 3 ]metronidazole, an FDA-approved antibiotic (in non-enriched and non-hyperpolarized form) and potential hypoxia sensing molecule. Specifically, we demonstrate that 15N polarization of 18.5 % can be obtained in 80 s of parahydrogen bubbling parahydrogen through a solution containing 20 mM [ 15 N 3 ]metronidazole. In practice, (1.32 ± 0.14)-fold improvements in P 15N was obtained with the pulsed method described here compared to static field technique variant. These results show that pulsed SABRE-SHEATH was successfully applied to 15 N-labeled biologically relevant molecule. Moreover, we also demonstrate that although the pulsed SABRE-SHEATH sequence was designed for polarization transfer from parahydrogen derived hydrides to the metronidazole’s 15 N catalyst-binding site, all three 15 N sites of [ 15 N 3 ]metronidazole attained the hyperpolarized state. This spin-relayed polarization transfer becomes possible due to the 15 N relay network established by their spin-spin J-couplings. The feasibility of the spin-relayed polarization transfer is demonstrated here for the first time for pulsed SABRE-SHEATH (as opposed to the static-field SABRE-SHEATH reported previously) and it paves the way to broad applicability of the technique.

Hyperpolarization↗

Mitigating Damage to Hybrid Perovskites Using Pulsed-Beam TEM

Using a pulsed-beam transmission electron microscope, we discover a reduction in damage to methylammonium lead iodide (MAPbI3) as compared to conventional beams delivered at the same dose rates. For rates as low as 0.001 e·Å –2 ·s –1 , we find up to a 17% reduction in damage at a total dose of 10 e·Å –2 . We systematically study the effects of number of electrons in each pulse and the duration between pulse arrival. Damage increases for both, though the number of electrons per pulse has a larger effect. A crossover is identified, where a pulsed beam causes more damage than a conventional one. Although qualitatively similar to previous findings, the degree to which damage is reduced in MAPbI3 is less than that observed for other materials (e.g., C36H74), supporting the hypothesis that the effects are material- and damage-mechanism-dependent. Despite this, the observation here of damage reduction for relatively large electron packets (up to 200 electrons per pulse) suggests that MAPbI3 is in fact less susceptible to irradiation than C36H74, which may be related to reported self-healing effects. This work provides insights into damage processes and durability in hybrid perovskites and also illustrates the viability of using pulsed-beam TEM to explore the associated molecular-level routes to degradation, analogous to laser-accelerated energetic pulsed electron beams and the study of damage to biomolecules, cells, and tissues in radiobiology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistical Analysis of Trans‐Ionospheric Pulse Pairs and Inferences on Their Characteristics

Trans-ionospheric pulse pairs (TIPPs), first observed in 1993, are signatures of in-cloud lightning discharges observed by satellite-based broadband very high frequency (VHF) receivers. It has been definitively shown that TIPPs are the space-based signatures of compact intracloud discharges (CIDs), and that the associated pair of pulses that comprise a TIPP result from the direct VHF pulse from the discharge, followed by a pulse reflected from the Earth's surface. However, the ratio of the peak amplitudes of these two pulses can vary widely, with the second pulse often having considerably higher peak amplitude than the first. This observation has not been satisfactorily explained. Using data collected from geostationary orbit by the Radio Frequency Sensor (RFS) and matched to locations reported by the Global Lightning Dataset (GLD360), we assemble the largest database to date of 76,348 TIPPs with associated location, altitude, and amplitude ratio of the two pulses in the TIPP. We show that the amplitude ratio of TIPPs is strongly correlated to the altitude of the associated discharges and the geometry of the source location with respect to the Earth's surface and the receiver. These observations strongly suggest that the difference in amplitude of the two pulses is driven by a nondipole radiated beam pattern that is dependent on the polarity of the CID, velocity of the current wavefront, and viewing angle.

58 GEOSCIENCES↗

Control of Early Flame Kernel Growth by Multi-Wavelength Laser Pulses for Enhanced Ignition

The present contribution examines the impact of plasma dynamics and plasma-driven fluid dynamics on the flame growth of laser ignited mixtures and shows that a new dual-pulse scheme can be used to control the kernel formation process in ways that extend the lean ignition limit. We do this by performing a comparative study between (conventional) single-pulse laser ignition (λ = 1064 nm) and a novel dual-pulse method based on combining an ultraviolet (UV) pre-ionization pulse (λ = 266 nm) with an overlapped near-infrared (NIR) energy addition pulse (λ = 1064 nm). We employ OH* chemiluminescence to visualize the evolution of the early flame kernel. For single-pulse laser ignition at lean conditions, the flame kernel separates through third lobe detachment, corresponding to high strain rates that extinguish the flame. In this work, we investigate the capabilities of the dual-pulse to control the plasma-driven fluid dynamics by adjusting the axial offset of the two focal points. In particular, we find there exists a beam waist offset whereby the resulting vorticity suppresses formation of the third lobe, consequently reducing flame stretch. With this approach, we demonstrate that the dual-pulse method enables reduced flame speeds (at early times), an extended lean limit, increased combustion efficiency, and decreased laser energy requirements.

42 ENGINEERING↗

Monte Carlo Simulations of Microchannel Plate Detectors II: Pulsed Voltage Results

This paper is part of a continuing study of straight-channel microchannel plate (MCP)–based x-ray detectors. Such detectors are a useful diagnostic tool for two-dimensional, time-resolved imaging and time-resolved x-ray spectroscopy. To interpret the data from such detectors, it is critical to develop a better understanding of the behavior of MCPs biased with subnanosecond voltage pulses. The subject of this paper is a Monte Carlo computer code that simulates the electron cascade in a MCP channel under an arbitrary pulsed voltage, particularly those pulses with widths comparable to the transit time of the electron cascade in the MCP under DC voltage bias. We use this code to study the gain as a function of time (also called the gate profile or optical gate) for various voltage pulse shapes, including pulses measured along the MCP. In addition, experimental data of MCP behavior in pulsed mode are obtained with a short-pulse UV laser. Comparisons between the simulations and experimental data show excellent agreement for both the gate profile and the peak relative sensitivity along the MCP strips. We report that the dependence of relative gain on peak voltage increases in sensitivity in pulsed mode when the width of the high-voltage waveform is smaller than the transit time of cascading electrons in the MCP.

Kruschwitz, Craig A.↗

Extraction of negative ions from pulsed electronegative capacitively coupled plasmas

Charge buildup during plasma etching of dielectric features can lead to undesirable effects, such as notching, bowing, and twisting. Pulsed plasmas have been suggested as a method to achieve charge-free plasma etching. In particular, electronegative plasmas are attractive as the collapse of the plasma potential during the after-glow period of pulsed capacitively coupled plasmas (CCPs) can allow for extraction of negative ions into the feature. The extraction of negative ions in the after-glow of pulsed CCPs sustained in CF{sub 4} containing gas mixtures is computationally investigated. In this paper, the consequences of pulse frequency and gas chemistry on negative ion flux to the wafer are discussed. A low negative ion flux to the wafer was observed only in the late after-glow period of low pulse frequencies. The negative ion flux was found to significantly increase with the addition of highly electronegative gases (such as thermally attaching Cl{sub 2}) even at a high pulse frequency of 10 kHz. As the production of negative ions during the after-glow diminishes, alternative strategies to enhance the flux were also pursued. The flux of negative ions was found to increase by the addition of a pulsed dc voltage on the top electrode that is 180 Degree-Sign out-of-phase with the rf pulse.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A long-pulse repetitive operation magnetically insulated transmission line oscillator

The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of silicon and indium gallium arsenide photodiodes as direct timing detectors for pulsed x-ray systems

Benchtop pulsed x-ray systems are commonly used to record dynamic material data on the order of nanoseconds, but pulse timing is often difficult to accurately determine. This study demonstrates that commercially available photodiodes can be used effectively for direct x-ray pulse detection without the need for visible light scintillators. X-ray pulses from four commercially available flash x-ray systems were quantified using one silicon and two indium gallium arsenide (InGaAs) photodiodes. The measured InGaAs pulse durations were strongly dependent on radiation dose in the non-linear operating regime, so the photodiodes were shielded to operate below the 2.5 V non-linear regime threshold. The average pulse duration and pulse arrival time jitter of the photodiodes for each x-ray source were within several nanoseconds with the exception of two sets of measurements that were affected by low instrument sensitivity and electrical noise. These results show that InGaAs photodiodes can be used as effective and repeatable stand-alone timing diagnostics for x-ray pulses as short as 20 ns or less.

47 OTHER INSTRUMENTATION↗