Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power production”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

A Modular AC to DC Interface Converter to Enable Lunar Surface Power Transmission

NASA is developing technology to enable sustained operations on extraterrestrial planetary bodies such as the Moon and Mars. One fundamentally enabling technology is long-distance electrical power transmission. This paper describes the Universal Modular Interface Converter (UMIC), which connects 120 VDC space power equipment to a 3 kVAC grid, and is intended to enable kilometer-distance transmission of 1s to 10s of kW of electrical power to support Artemis and future lunar missions. Specifically, this paper describes the technology within the UMIC product, its electrical power interfaces, and the state of its development. It also describes initial hardware and simulation test results of the UMIC.

Planetary surface power↗

Concentrated Solar Power as a Pathway for Electrolytic Hydrogen Production

William Xi and Mark Ruth of the National Renewable Energy Laboratory (NREL), will present a new solar-electrolysis technoeconomic assessment capability: low-temperature and high-temperature electrolysis in the System Advisor Model (SAM) environment. They will also present analysis results including opportunities for solar-hydrogen systems to achieve the $2/kg hydrogen cost target.

concentrating solar power↗

Semiconductor Cubing

Through Goddard Space Flight Center and Jet Propulsion Laboratory Small Business Innovation Research contracts, Irvine Sensors developed a three-dimensional memory system for a spaceborne data recorder and other applications for NASA. From these contracts, the company created the Memory Short Stack product, a patented technology for stacking integrated circuits that offers higher processing speeds and levels of integration, and lower power requirements. The product is a three-dimensional semiconductor package in which dozens of integrated circuits are stacked upon each other to form a cube. The technology is being used in various computer and telecommunications applications.

Source record↗

Projecting Future Colorado River Basin Water and Hydropower Operations

Drought, variable renewable energy (VRE) resources (primarily wind and photovoltaic technologies), and power markets can all impact hydropower plant operations. We analyze how these three factors collectively may potentially change the future operation and economics of federal dams and hydropower plants located in the Colorado River Basin (CRB). Federal CRB energy and capacity resources, including 4,200 MW of hydropower capacity, are marketed by Western Area Power Administration (WAPA) and sold through long-term Firm Electric Service (FES) contracts to entities located in 15 western and central States that serve millions of electricity consumers. The parameters of FES contracts allow a wide range of scheduling flexibility for FES customers. The FES customers will adjust the timing of energy delivery according to the changing water, power market, and VRE contribution level to the power grid. We simulate and project water and hydropower operations with two models: 1) reservoir operation and 2) power system operation (production cost) with various temporal granularity. We consider two sets of grid scenarios (one representing today's infrastructure, and one representing higher VRE contributions in 2036) and two sets of water scenarios (drought and normal hydrology). We modeled scenarios to understand the power market-energy price levels and patterns, FES customer scheduling, hydropower economics, WAPA finances and hydropower operation for various hydrologic conditions, and VRE contribution level to the power grid. The detailed modeling framework includes: (1) creating ensembles of CRB hydrologic and hydropower futures, (2) selecting representative futures, (3) simulation of FES customer contracts, (4) simulating western U.S. power grid economic scheduling and dispatch under two VRE contribution levels, utilizing information from modeling steps (1)-(4), (5) assessment of reservoir water and hydropower operation, and (6) comparing scenario operations and economics. Our study team comprising WAPA, and an interdisciplinary team of national labs will gain insight into how WAPA can prepare for and adapt its practices in response to an evolving U.S. power grid.

Colorado River↗

Investigation of applications for high-power, self-critical fissioning uranium plasma reactors

Analytical studies were conducted to investigate potentially attractive applications for gaseous nuclear cavity reactors fueled by uranium hexafluoride and its decomposition products at temperatures of 2000 to 6000 K and total pressures of a few hundred atmospheres. Approximate operating conditions and performance levels for a class of nuclear reactors in which fission energy removal is accomplished principally by radiant heat transfer from the high temperature gaseous nuclear fuel to surrounding absorbing media were determined. The results show the radiant energy deposited in the absorbing media may be efficiently utilized in energy conversion system applications which include (1) a primary energy source for high thrust, high specific impulse space propulsion, (2) an energy source for highly efficient generation of electricity, and (3) a source of high intensity photon flux for heating working fluid gases for hydrogen production or MHD power extraction.

Rodgers, R. J.↗

Evaluation of shear mounted elastomeric damper

Viton-70 elastomeric shear mounted damper was built and tested on a T-55 power turbine spool in the rotor's high speed balancing rig. This application of a shear mounted elastomeric damper demonstrated for the first time, the feasibility of using elastomers as the primary rotor damping source in production turbine engine hardware. The shear damper design was selected because it was compatible with actual gas turbine engine radial space constraints, could accommodate both the radial and axial thrust loads present in gas turbine engines, and was capable of controlled axial preload. The shear damper was interchangeable with the production T-55 power turbine roller bearing support so that a direct comparison between the shear damper and the production support structure could be made. Test results show that the Viton-70 elastomer damper operated successfully and provided excellent control of both synchronous and nonsynchronous vibrations through all phases of testing up to the maximum rotor speed of 16,000 rpm. Excellent correlation between the predicted and experienced critical speeds, mode shapes and log decrements for the power turbine rotor and elastomer damper assembly was also achieved.

Zorzi, E.↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling a Lead-Cooled Fast Reactor with Thermal Energy Storage using Optimal Dispatch and SAM

Increased contributions from wind and solar energy have helped set the United States on an attainable pathway towards carbon-free energy production. Though renewable energy is pivotal for this goal, saturating the grid with these variable energy sources has its challenges. Resources for wind and solar vary from factors beyond human control, hence the power output from these energy generators doesn’t necessarily match power demand for a specific region at a given moment in time. Solar photovoltaic production has a drastic mismatch since the peaks for power demand and power production are often out of phase: production peaks with available irradiance while demand peaks during the morning and evening hours. This “duck curve” in energy demand, the difference between high and low demand, grows as the grid becomes more saturated with renewable energy providers.

Soto, Gabriel J.↗

Advanced Power and Propulsion: Insuring Human Survival and Productivity in Deep Space Missions

Dr. Chang-Diaz gave an intriguing presentation of his research in advanced rocket propulsion and its relevance for planning and executing crewed deep space explorations. Though not necessarily exclusively Martian, his thrust looks critically at future Mars missions. Initially Dr. Chang-Diaz showed the time constraints of Mars missions due to orbital mechanics and our present chemically powered rocket technology. Since essentially all the energy required to place current generation spacecraft into a Martian trajectory must be expended in the early minutes of a flight, most of such a mission is spent in free-fall drift, captive to the gravitational forces among Earth, the Sun, and Mars. The simple physics of such chemically powered missions requires nearly a year in transit for each direction of a Mars mission. And the optimal orientations of Earth and Mars for rendezvous require further time on or around Mars to await return. These extensions of mission duration place any crew under a three-fold jeopardy: (1) physiological deconditioning (which in some aspects is still unknown and unpreventable), (2) psychological stress, and (3) ionizing radiation. This latter risk is due to exposure of crew members for extended time to the highly unpredictable and potentially lethal radiations of open space. Any gains in shortening mission duration would reap equivalent or greater benefits for these crew concerns. Dr. Chang-Diaz has applied his training and expertise (Ph.D. from Massachusetts Institute of Technology in applied plasma physics) toward development of continuous rocket propulsion which would offer great time advantages in travel, and also more launch options than are now available. He clearly explained the enormous gains from a relatively low thrust accelerative force applied essentially continuously versus the high, but short-lived propulsion of present chemical rockets. In fact, such spacecraft could be powered throughout the mission, accelerating to approximately the midpoint and decelerating during the latter half. This would not only provide some level of gravity (acceleration) throughout the mission but also allow very high velocities to be achieved, thus saving many months of travel time. In proposing the design of such a spacecraft propulsion system, Dr. Chang-Diaz was quick to acknowledge the need for a large power source, which undoubtedly must be nuclear fueled at the solar distances involved. He calls his system the Variable Specific Impulse Magnetoplasma Rocket (VASIMR). The other major ingredient is a mass (deuterium, which could also function as a radiation shield for crews) for energizing into the ultra hot, high velocity exhaust plasma. He foresees models now functional in the laboratory soon to be tested in space. In fact, some of these concepts have already been tried there. His optimism and determination would have operational rockets in the next decades.

Chang-Diaz, Franklin R.↗

Boosting the performances of protonic solid oxide fuel cells for co-production of propylene and electricity from propane by integrating thermo- and electro- catalysis

Protonic solid oxide fuel cells (p-SOFC) integrated with clean thermal energy sources are promising platforms for decarbonized chemical production in addition to power generation, such as on-purpose propylene production from propane dehydrogenation (PDH). The catalytic performance of the conventional nickel-cermet-based anode materials in p-SOFC for propane conversion is restrained by their low active surface area and proneness to coking. In this work, by integration of a highly efficient industry-relevant thermal catalyst PtGa/ZSM-5 for PDH reaction, we demonstrate that both the electrochemical and catalytic performance of the propane-fueled p-SOFC can be effectively enhanced. The PtGa catalyst integrated p-SOFC exhibits a peak power density of 93 mW cm -2 at 600°C, which is greater by about 100% and 50% than that without catalyst or with a perovskite-based (Pr 0.3 Sr 0.7 ) 0.9 Ni 0.1 Ti 0.9 O 3 (PSNT) catalyst layer, respectively. The PDH activity and olefin selectivity of the PtGa catalyst is also significantly higher than that of the PSNT catalyst. In addition, much improved coke tolerance and propylene selectivity (over 90%) compared to the catalyst-free Ni-cermet anode materials were achieved by integrating the industrial catalyst layer. The propane conversion can be further improved by an applied current density, whereas the olefin selectivity is almost unaltered. The excellent performance of the PtGa catalyst integrated p-SOFC is attributed to the high surface area, intrinsically high catalytic activity, selectivity, and anti-coking properties of the catalytic layer for propane conversion. In conclusion, this work provides a general approach and a case study for boosting the performances of p-SOFCs in chemical production by integrating thermo- and electro- catalysis.

30 DIRECT ENERGY CONVERSION↗

Composite Cores

Spang & Company's new configuration of converter transformer cores is a composite of gapped and ungapped cores assembled together in concentric relationship. The net effect of the composite design is to combine the protection from saturation offered by the gapped core with the lower magnetizing requirement of the ungapped core. The uncut core functions under normal operating conditions and the cut core takes over during abnormal operation to prevent power surges and their potentially destructive effect on transistors. Principal customers are aerospace and defense manufacturers. Cores also have applicability in commercial products where precise power regulation is required, as in the power supplies for large mainframe computers.

Source record↗

High-Altitude, Long-Endurance Airships for Coastal Surveillance

A high altitude solar powered airship provides the ability to carry large payloads to high altitudes and remain on station for extended periods of time. This study examines applications and background of this type of concept vehicle, reviews the history of high altitude flight and provides a point design analysis. The capabilities and limitations of the airship are demonstrated and possible solutions are proposed. Factors such as time of year, latitude, wind speeds, and payload are considered in establishing the capabilities of the airship. East and west coast operation is evaluated. The key aspect to success of this type of airship is the design and operation of the propulsion and power system. A preliminary propulsion/power system design was produced based on a regenerative fuel cell energy storage system and solar photovoltaic array for energy production. Results on power system requirements for year long operation is presented.

Dolce, James L.↗

NASA objectives for improved solar power plants

The present work describes the principal goals for the main effort of NASA's research and development of solar photovoltaic cells and arrays. These are (1) to reduce array costs from $270/watt to $90/watt (no change in volume) or to $41/watt (high volume production), (2) raise power density from 66 watts/kg to 110 watts/kg, and (3) minimize dynamic interaction problems. The first two goals can be accomplished by increased cell efficiency, reduced cell thickness, the development of a multiple ribbon growth process, and automation of cell production. To minimize dynamic interaction between array and spacecraft, module flexibility will be increased.

Cohn, E. M.↗

A review of test results on solar thermal power modules with dish-mounted Stirling and Brayton cycle engines

This paper presents results of development tests of various solar thermal parabolic dish modules and assemblies that used dish-mounted Brayton or Stirling cycle engines for production of electric power. These tests indicate that early modules achieve net efficiencies up to 29 percent in converting sunlight to electricity, as delivered to the grid. Various equipment deficiencies were observed and a number of malfunctions occurred. The performance measurements, as well as the malfunctions and other test experience, provided information that should be of value in developing systems with improved performance and reduced maintenance.

Jaffe, Leonard D.↗

Hydropower operation in future power grid with various renewable power integration

Hydropower generation may play an increasingly important role in the power grid under increasing contribution of variable renewable sources such as wind and solar. An improved understanding of the changes to hydropower dispatch under future higher VRE grid conditions reveals research gap that should be informed power grid planning and reservoir water releases policies considering multiple other water uses and varying hydrologic condition. Here this study aims to understand the role of hydropower in a changing power grid by employing a production cost model, PLEXOS, across future power system scenarios, planning horizons, and regions. We explore optimized hydropower dispatch to understand its potential role in minimizing the system cost and renewable curtailment. We also examine the sensitivity of hydropower revenue under various grid scenarios of the Eastern U.S. and hydrology conditions. Results indicate hydropower generation follows net load and compensates for the variability of solar and wind generation. Although energy prices are lower during some periods in the future grid scenarios, there is a potential for higher revenue for hydropower by providing both energy and ancillary services during times of stress. Additionally, hydropower revenue is sensitive to hydrology in the SERC region, which we considered as an example. The feasibility of hydropower dispatching with higher ramps between low and high hourly-capacity factors, as indicated in the optimization model, requires further study to consider other water use and ecology constraints.

13 HYDRO ENERGY↗

Experimental evaluation of a breadboard heat and product-water removal system for a space-power fuel cell designed with static water removal and evaporative cooling

A test program was conducted to evaluate the design of a heat and product-water removal system to be used with fuel cell having static water removal and evaporative cooling. The program, which was conducted on a breadboard version of the system, provided a general assessment of the design in terms of operational integrity and transient stability. This assessment showed that, on the whole, the concept appears to be inherently sound but that in refining this design, several facets will require additional study. These involve interactions between pressure regulators in the pumping loop that occur when they are not correctly matched and the question of whether an ejector is necessary in the system.

Hagedorn, N. H.↗

Wake steering optimization under uncertainty

Turbines in wind power plants experience significant power losses when wakes from upstream turbines affect the energy production of downstream turbines. A promising plant-level control strategy to reduce these losses is wake steering, where upstream turbines are yawed to direct wakes away from downstream turbines. However, there are significant uncertainties in many aspects of the wake steering problem. For example, infield sensors do not give perfect information, and inflow to the plant is complex and difficult to forecast with available information, even over short time periods. Here, we formulate and solve an optimization under uncertainty (OUU) problem for determining optimal plant-level wake steering strategies in the presence of independent uncertainties in the direction, speed, turbulence intensity, and shear of the incoming wind, as well as in turbine yaw positions. The OUU wake steering strategy is first examined for a two-turbine test case to explore the impacts of different types of inflow uncertainties, and it is then demonstrated for a more realistic 11-turbine wind power plant. Of the sources of uncertainty considered, we find that wake steering strategies are most sensitive to uncertainties in the wind speed and direction. When maximizing expected power production, the OUU strategy also tends to favor smaller yaw angles, which have been shown in previous work to reduce turbine loading. Ultimately, the plant-level wake steering strategy formulated using an OUU approach yields 0.48?% more expected annual energy production for the 11-turbine wind plant than a strategy that neglects uncertainty when considering stochastic inputs. Thus, not only does the present OUU strategy produce more power in realistic conditions, but it also reduces risk by prescribing strategies that call for less extreme yaw angles.

17 WIND ENERGY↗