Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “positron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Nuclear Instruments and Methods in Physics Research: Microstructural Characterization of Semi-Interpenetrating Polymer Networks by Positron Lifetime Spectroscopy - Section B

Thermoset and thermoplastic polyimides have complementary physical/mechanical properties. Whereas thermoset polyimides are brittle and generally easier to process, thermoplastic polyimides are tough but harder to process. It is expected that a combination of these two types of polyimides may help produce polymers more suitable for aerospace applications. Semi-Interpenetrating Polymer Networks (S-IPNs) of thermoset LaRC(Trademark)-RP46 and thermoplastic LARC(Trademark)-IA polyimides were prepared in weight percent ratios ranging from 100:0 to 0: 100. Positron lifetime measurements were made in these samples to correlate their free volume features with physical/mechanical properties. As expected, positronium atoms are not formed in these samples. The second life time component has been used to infer the positron trap dimensions. The "free volume" goes through a minimum at about 50:50 ratio, suggesting that S-IPN samples are not merely solid solutions of the two polymers. These data and related structural properties of the S-IPN samples have been discussed in this paper.

Singh, Jag J.↗

The Positronium Radiative Combination Spectrum: Calculation in the Limit of Thermal Positrons and Low Densities

We calculate the intensities of the positronium de-excitation lines for two processes: (1) the radiative combination of free thermal electrons and positrons for transitions with principal quantum number n less than 20, and (2) charge exchange between free positrons and hydrogen and helium atoms, restricting our evaluation to the Lyman-alpha line. We consider a low-density medium modeled by the case A assumption of Baker & Menzel and use the "nL method" of Pengelly to calculate the absolute intensities. We also evaluate the positronium fine and hyperfine intensities and show that these transitions are in all cases much weaker than positronium de-excitation lines in the same wavelength range. We also extrapolate our positronium de-excitation intensities to the submillimeter, millimeter, and centimeter wavelengths. Our results favor the search of infrared transitions of positronium lines for point sources when the visual extinction A, is greater than approx. 5.

Wallyn, P.↗

Small Explorer (SMEX) POsitron Electron Magnet Spectrometer (POEMS)

This report covers the activities of Louisiana State University (LSU) under subcontract 26053-EX between LSU and the Bartol Research Institute (Bartol), which began January 1, 1994. The purpose of this subcontract was for LSU to participate in and support Bartol in the work to define the SMEX (Small Explorer)/POEMS (Positron Electron Magnet Spectrometer) spaceflight mission under NASA Contract NAS5-38098 between NASA and Bartol. The conclusions of this study were that for a 1998 launch into a 600km altitude, 98 degrees, approximately sun synchronous orbit, (a) the total radiation dose would be typically a few k-rad per year, certainly less than 20 k-rad per year for the anticipated shielding and potential solar flare environment, (b) detector counting rates would be dominated by the South Atlantic Anomaly (SAA) and the horns of the Van Allen belts, (c) the galactic electron and positron 'signal' can be extracted from the albedo background and the trapped populations by detailed evaluation of the geomagnetic transmission function (cut-off) for each event, (d) POEMS could make significant contributions to magnetospheric science if sufficient downlink capacity were provided and, (e) a fully functioning, cost efficient, data processing and analysis facility design was developed for the mission. Overall, POEMS was found to be a relatively simple experiment to manifest, operate and analyze and had potential for fundamental new discoveries in cosmic, heliospheric, solar and magnetospheric science.

LHeureux, Jacques↗

Microstructural Characterization of Polymers with Positrons

Positrons provide a versatile probe for monitoring microstructural features of molecular solids. In this paper, we report on positron lifetime measurements in two different types of polymers. The first group comprises polyacrylates processed on earth and in space. The second group includes fully-compatible and totally-incompatible Semi-Interpenetrating polymer networks of thermosetting and thermoplastic polyimides. On the basis of lifetime measurements, it is concluded that free volumes are a direct reflection of physical/electromagnetic properties of the host polymers.

Singh, Jag J.↗

Asymmetric 511 keV Positron Annihilation Line Emission from the Inner Galactic Disk

A recently reported asymmetry in the 511 keV gamma-ray line emission from the inner galactic disk is unexpected and mimics an equally unexpected one in the distribution of LMXBs seen at hard X-ray energies. A possible conclusion is that LMXBs are an important source of the positrons whose annihilation gives rise to the line. We will discuss these results, their statistical significance and that of any link between the two. The implication of any association between LMXBs and positrons for the strong annihilation radiation from the galactic bulge will be reviewed.

Skinner, Gerry↗

Portable Positron Measurement System (PPMS)

Portable Positron Measurement System (PPMS) is an automated, non-destructive inspection system based on positron annihilation, which characterizes a material's in situatomic-level properties during the manufacturing processes of formation, solidification, and heat treatment. Simultaneous manufacturing and quality monitoring now are possible. Learn more about the lab's project on our facebook site http://www.facebook.com/idahonationallaboratory.

36 MATERIALS SCIENCE↗

Surgical guidance system using hand-held probe with accompanying positron coincidence detector

A surgical guidance system offering different levels of imaging capability while maintaining the same hand-held convenient small size of light-weight intra-operative probes. The surgical guidance system includes a second detector, typically an imager, located behind the area of surgical interest to form a coincidence guidance system with the hand-held probe. This approach is focused on the detection of positron emitting biomarkers with gamma rays accompanying positron emissions from the radiolabeled nuclei.

Majewski, Stanislaw↗

Precision measurement of positron decay modes of Xe-125 in the LUX-ZEPLIN experiment

The radioisotope $^{125}\text{Xe}$ is a short-lived ($T_{1/2}\sim16.9 h$) activation product of the neutron calibrations performed in the LUX-ZEPLIN experiment. Subsequently, $^{125}$Xe decays primarily ($>99\%$) via electron capture, but positron emission has been confirmed by direct measurement to at least the 243 keV level of $^{125}\text{I}$. An additional decay to the 188keV level is expected from triple-coincident measurements of the annihilation and relaxation $γ$ rays, but has not been directly confirmed. By utilizing multiple-scatter event analysis and the pre-activation data to constrain backgrounds, this work reports positron emission with a statistical significance of 5.5$σ$. This corresponds to a total branching ratio of $0.29\pm0.08_{\text{stat.}}\pm0.04_{\text{sys.}}$%, and is the first constraint to the individual branching levels of $^{125}\text{I}$.

Akerib, D. S. [SLAC; KIPAC, Menlo Park]↗

Application of exterior complex scaling to positron-hydrogencollisions including rearrangement

The first application of an exterior complex scaling method to an atomic scattering problem with distinct rearrangement channels is reported. Calculations are performed for positron-hydrogen collisions in an s-wave model employing an electron-positron potential of V{sub 12} = -(8+(r{sub 1}-r{sub 2}){sup 2}){sup 1/2}, using the time-independent propagating exterior complex scaling (PECS) method. This potential has the correct long-range Coulomb tail of the full problem and the results demonstrate that ECS-based methods can accurately calculate scattering, ionization and positronium formation cross sections in this three-body rearrangement collision.

74 ATOMIC AND MOLECULAR PHYSICS↗

Accessing neutral weak coupling C{sub 3q} using polarized positron and electron beams at Jefferson Lab

Electroweak neutral weak couplings are important parameters of the Standard Model of particle physics. The product of lepton and quark couplings, C{sub 1q}, C{sub 2q} and C{sub 3q}, can be accessed from lepton scatterings via either parity violation or charge conjugate violations. In contrast to C{sub 1,2q} for which experiments have been planned to improve their precisions, the C{sub 3q} couplings have only been measured at limited facilities due to difficulties in comparing scattering cross sections between lepton and anti-lepton beams. In this document, the current knowledge on C{sub 1,2,3q} is reviewed first, followed by a sensitivity study of C{sub 3q} measurement using a possible positron beam at Jefferson Lab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Convergent close-coupling calculations of positron scattering on metastable helium

The convergent close-coupling method has been applied to positron scattering on a helium atom in the 2 {sup 3}S metastable state. For this system the positronium (Ps) formation channel is open even at zero scattering energy making the inclusion of the Ps channels especially important. Spin algebra is presented for the general case of arbitrary spins. A proof is given of the often-used assumption about the relationship between the amplitudes for ortho-positronium and para-positronium formation. The cross sections for scattering from 2 {sup 3}S are shown to be significantly larger than those obtained for the ground state.

74 ATOMIC AND MOLECULAR PHYSICS↗

Low-energy positron interactions with krypton

Cross sections for positron scattering from krypton have been measured with an energy resolution of {approx}60 meV over the energy range 0.5-60 eV. Absolute values of the grand total ({sigma}{sub GT}), positronium formation ({sigma}{sub Ps}), and grand total minus positronium formation ({sigma}{sub GT}-{sigma}{sub Ps},) cross sections are presented. Theoretical estimations of {sigma}{sub GT} and {sigma}{sub GT}-{sigma}{sub Ps} are also performed for this target using the convergent close-coupling method and the relativistic optical potential approach. We also provide experimental and theoretical results for elastic differential cross sections, for selected energies both below and above the Ps threshold. Where available, the present results are compared to both experimental and theoretical values from the literature.

74 ATOMIC AND MOLECULAR PHYSICS↗

Zeolite‐Based Catalysts for Conversion of Oxygenated Polymer Waste by Positron Annihilation

Positron Annihilation Lifetime Spectroscopy (PALS) has been employed to investigate the catalysts HZSM-5 and MESO−Y, which play a pivotal role in catalyzing and upgrading plastics, with a primary focus on oxygenated polymers, thereby transforming existing plastic materials into simpler, higher-quality value-added products. Here, in this study, PALS was systematically compared with other complementary analytical techniques. The research outcomes have successfully demonstrated the efficacy of PALS in elucidating the morphology and topology of zeolites at micro/meso-meter scales. The first experiment focuses on H-ZSM-5 zeolite subjected to treatments involving polyurethane and polypropylene. The second experiment delves into H-ZSM-5 zeolites with varying Si/Al ratios, both before and after conversion. The third experiment investigates Y zeolites that are surfactant templated to induce meso-porosity, examining their fresh state as well as their post-conversion condition. The PALS analysis was supplemented by BET (Brunauer-Emmett-Teller) analysis and NMR (Nuclear Magnetic Resonance) spectroscopies. Notably, PALS exhibits superior sensitivity, at the sub-nanometer scale, suggesting its potential as a preferred complementary method for catalysis studies. In conclusion, the integration of PALS into the repertoire of analytical tools enhances our understanding of catalyst behavior and catalytic processes, offering valuable insights for the advancement of plastic recycling and catalysis research.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Relative Defect Density Measurements of Laser Shock Peened 316L Stainless Steel Using Positron Annihilation Spectroscopy

The surface of an annealed 316L stainless steel coupon was laser shock peened and Vickers hardness measurements were subsequently taken of its surface. This Vickers hardness data was compared with measurements taken using the technique of positron annihilation Doppler broadening spectroscopy. When compared, a correlation was found between the Vickers hardness data measurements and those made using Doppler broadening spectroscopy. Although materials with a high defect density can cause the S-parameter measurements to saturate, variations in the Sparameter measurements suggest that through further research the Doppler broadening technique could be used as a viable alternative to measuring a material's hardness. In turn, this technique, could be useful in industrial settings where surface hardness and surface defects are used to predict lifetime of components.

36 MATERIALS SCIENCE↗

Fluorine-18-Labeled Fluoromisonidazole Positron Emission and Computed Tomography-Guided Intensity-Modulated Radiotherapy for Head and Neck Cancer: A Feasibility Study

Purpose: Hypoxia renders tumor cells radioresistant, limiting locoregional control from radiotherapy (RT). Intensity-modulated RT (IMRT) allows for targeting of the gross tumor volume (GTV) and can potentially deliver a greater dose to hypoxic subvolumes (GTV{sub h}) while sparing normal tissues. A Monte Carlo model has shown that boosting the GTV{sub h} increases the tumor control probability. This study examined the feasibility of fluorine-18-labeled fluoromisonidazole positron emission tomography/computed tomography ({sup 18}F-FMISO PET/CT)-guided IMRT with the goal of maximally escalating the dose to radioresistant hypoxic zones in a cohort of head and neck cancer (HNC) patients. Methods and Materials: {sup 18}F-FMISO was administered intravenously for PET imaging. The CT simulation, fluorodeoxyglucose PET/CT, and {sup 18}F-FMISO PET/CT scans were co-registered using the same immobilization methods. The tumor boundaries were defined by clinical examination and available imaging studies, including fluorodeoxyglucose PET/CT. Regions of elevated {sup 18}F-FMISO uptake within the fluorodeoxyglucose PET/CT GTV were targeted for an IMRT boost. Additional targets and/or normal structures were contoured or transferred to treatment planning to generate {sup 18}F-FMISO PET/CT-guided IMRT plans. Results: The heterogeneous distribution of {sup 18}F-FMISO within the GTV demonstrated variable levels of hypoxia within the tumor. Plans directed at performing {sup 18}F-FMISO PET/CT-guided IMRT for 10 HNC patients achieved 84 Gy to the GTV{sub h} and 70 Gy to the GTV, without exceeding the normal tissue tolerance. We also attempted to deliver 105 Gy to the GTV{sub h} for 2 patients and were successful in 1, with normal tissue sparing. Conclusion: It was feasible to dose escalate the GTV{sub h} to 84 Gy in all 10 patients and in 1 patient to 105 Gy without exceeding the normal tissue tolerance. This information has provided important data for subsequent hypoxia-guided IMRT trials with the goal of further improving locoregional control in HNC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation of ultra-relativistic electrons and positrons channeling in crystals with MBN EXPLORER

A newly developed code, implemented as a part of the MBN EXPLORER package (Solov'yov et al., 2012; (http://www.mbnexplorer.com/), 2012) [1,2] to simulate trajectories of an ultra-relativistic projectile in a crystalline medium, is presented. The motion of a projectile is treated classically by integrating the relativistic equations of motion with account for the interaction between the projectile and crystal atoms. The probabilistic element is introduced by a random choice of transverse coordinates and velocities of the projectile at the crystal entrance as well as by accounting for the random positions of the atoms due to thermal vibrations. The simulated trajectories are used for numerical analysis of the emitted radiation. Initial approbation and verification of the code have been carried out by simulating the trajectories and calculating the radiation emitted by ε=6.7 GeV and ε=855 MeV electrons and positrons in oriented Si(110) crystal and in amorphous silicon. The calculated spectra are compared with the experimental data and with predictions of the Bethe–Heitler theory for the amorphous environment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Possibility to achieve an antiproton polarizer by scattering off polarized positrons

The theoretical prediction for the polarizing cross section when scattering antiprotons off polarized e-vector{sup +} amounts to 2.10{sup 13} barn at 1.7 keV hadron energy in the e-vector{sup +} rest frame. Under this conditions polarizing stored antiprotons in a cooler-like arrangement becomes feasible. Compact e-vector{sup +} sources of sufficient intensity can be provided with present day technology in order to achieve a polarization of P{sub p} = 0.17 for 10{sup 10} stored antiprotons within one hour. Positron storage ring based designs offer an enormous increase in intensity, making an efficient polarizer feasible, even if the cross sections are many orders of magnitude smaller than presently predicted.

43 PARTICLE ACCELERATORS↗