Which calibration-pulse location method is robust?

The Threshold method, with high threshold and contiguous-block parameter values, was found to be a robust method of locating calibration pulses in the presence of light-leak and shutter-edge pulses within the calibration window. Tests used digitized calibration-window background and light-pulse data from the Landsat-5 Thematic Mapper (TM) instrument, analyzed by special software on an Apple II+ personal computer and on a VAX 11/780 minicomputer.

Gunther, F. J.↗

Roughness Parameter Optimization of the McClain Model in GlennICE

Aircraft icing remains a significant threat to aviation safety. Software that predicts the impingement and ice accretion on full aircraft geometries and aircraft components are in demand and NASA Glenn is committed to produce software that meets this need. One of the key parameters affecting an accurate prediction of iced geometry is the effect of ice roughness on the heat transfer coefficient. While many efforts have been made to implement the roughness in the flow solver, this report takes a correlation for roughness height distribution that is based on experimental measurements and demonstrates how to relate those measurements to an augmentation to the heat transfer coefficient provided by the flow solution. The outcome of this effort was the calibration of defaults for user supplied parameters to this correlation through comparison with 95 large glaze conditions from experiment by adjusting user-supplied parameters in the roughness augmentation equation.

Aircraft Icing↗

Overview of Aqua MODIS 10-year On-orbit Calibration and Performance

Since launch in May 2002, Aqua MODIS has successfully operated for nearly 10 years, continuously collecting global datasets for scientific studies of key parameters of the earth's land, ocean, and atmospheric properties and their changes over time. The quality of these geophysical parameters relies on the input quality of sensor calibrated radiances. MODIS observations are made in 36 spectral bands with wavelengths ranging from visible (VIS) to longwave infrared (LWIR). Its reflective solar bands (RSB) are calibrated using data collected from its on-board solar diffuser and regularly scheduled lunar views. The thermal emissive bands (TEB) are calibrated using an on-board blackbody (BB). The changes in the sensor's spectral and spatial characteristics are monitored by an on-board spectroradiometric calibration assembly (SRCA). This paper presents an overview of Aqua MODIS 10-year on-orbit operation and calibration activities, from launch to present, and summarizes its on-orbit radiometric, spectral, and spatial calibration and characterization performance. In addition, it will illustrate and discuss on-orbit changes in sensor characteristics and corrections applied to continuously maintain the sensor level 1B (L1B) data quality, as well as lessons learned that could benefit future calibration efforts.

Xiong, X.↗

Approach to derivation of SIR-C science requirements for calibration

Many of the experiments proposed for the forthcoming SIR-C mission require calibrated data, for example those which emphasize (1) deriving quantitative geophysical information (e.g., surface roughness and dielectric constant), (2) monitoring daily and seasonal changes in the Earth's surface (e.g., soil moisture), (3) extending local case studies to regional and worldwide scales, and (4) using SIR-C data with other spaceborne sensors (e.g., ERS-1, JERS-1, and Radarsat). There are three different aspects to the SIR-C calibration problem: radiometric and geometric calibration, which have been previously reported, and polarimetric calibration. The study described in this paper is an attempt at determining the science requirements for polarimetric calibration for SIR-C. A model describing the effect of miscalibration is presented first, followed by an example describing how to assess the calibration requirements specific to an experiment. The effects of miscalibration on some commonly used polarimetric parameters are also discussed. It is shown that polarimetric calibration requirements are strongly application dependent. In consequence, the SIR-C investigators are advised to assess the calibration requirements of their own experiment. A set of numbers summarizing SIR-C polarimetric calibration goals concludes this paper.

Dubois, Pascale C.↗

Model Calibration for Cancer Risk Projections According to Uncertain Data

This paper presents forward and inverse formulations for the calibration of computational models according to uncertain data. Uncertainty in the data might be caused by a poor metrology system, measurement noise, missing or uncontrollable input variables, or by the inability to directly measure the inputs and/or outputs of interest. The forward approach performs the calibration in the space of the model’s output thereby requiring repeated model simulations. Conversely, the inverse approach leverages an ensemble of solutions to an inverse problem in order to perform the calibration in the space of the model’s parameters. As such, the computational demands of the inverse approach are considerably lower. These strategies are applied to the calibration of a radiation model that in-forms cancer risk projections for future deep space missions.

uncertainty quantification↗

Benchmarking core turbulence and transport predictions for an inductive compact tokamak reactor plasma

Motivated by the need for accurate, timely, and efficient calculations of plasma transport, predictions of plasma turbulence properties made using different TGLF saturation rules are benchmarked against corresponding predictions from linear and nonlinear gyrokinetic CGYRO simulations. This benchmarking is carried out using parameters taken from an inductive burning plasma scenario in a hypothetical compact high-field (R maj = 4 m, B T = 8 T) tokamak, lying in a much different regime of parameter space than either the TGLF calibration regime or current-day experiments. The core turbulent transport in this scenario is predicted to be dominated by ion temperature gradient (ITG) turbulence. In general, the ITG critical gradients predicted by various TGLF saturation rules are quite close to the CGYRO predictions. Both codes predict similar linear ITG growth rates and frequency spectra, as well as their scaling with R/L T i = −Rd ln(T i )/dr. However, TGLF systematically predicts unstable trapped-electron modes (TEMs) above k y ρ s ≃ 0.5 not seen by CGYRO for the same parameters, due to TGLF predicting a lower threshold in R/L T e than CGYRO for TEM onset. It is shown that for this scenario, nonlinear CGYRO simulations predict stiffer ITG turbulence than the TGLF SAT0 and SAT1 saturation rules, with energy fluxes close in magnitude and scaling with R/L T i to what is predicted by the SAT2 saturation rule. Self-consistent core profiles calculated using nonlinear CGYRO flux predictions and the PORTALS transport solver are shown to agree fairly well with corresponding predictions made using the TGLF SAT2 model, including a similar level of density peaking.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Revealing the unusual rate-dependent mechanical behaviors of nematic liquid crystal elastomers

Liquid crystal elastomers (LCEs) exhibit unique mechanical properties of soft elasticity and enhanced energy dissipation with rate dependency. They are potentially transformative materials for applications in mechanical impact mitigation and vibration isolation. However, previous studies have primarily focused on the mechanics of LCEs under equilibrium and quasistatic loading conditions. Critical knowledge gaps exist in understanding their rate-dependent behaviors, which are a complex mixture of traditional network viscoelasticity and the soft elastic behaviors with changes in the mesogen orientation and order parameter. Together, these inelastic mechanisms lead to unusual rate-dependent energy absorption responses of LCEs. In this work, we developed a viscoelastic constitutive theory for monodomain nematic LCEs to investigate how multiple underlying sources of inelasticity manifest in the rate-dependent and dissipative behaviors of monodomain LCEs. Here, the theoretical modeling framework combines the neo-classical network theory with evolution rules for the mesogen orientation and order parameter with conventional viscoelasticity. The model is calibrated with uniaxial tension and compression data spanning six decades of strain rates. The established 3D constitutive model enables general loading predictions taking the initial mesogen orientation and order parameter as inputs. Additionally, parametric studies were performed to further understand the rate dependence of monodomain LCEs in relation to their energy absorption characteristics. Based on the parametric studies, particularly loading scenarios are identified as conditions where LCEs outperform conventional elastomers regarding energy absorption.

42 ENGINEERING↗

Calibration of the Airborne Visible/Infrared Imaging Spectrometer in the Laboratory

Imaging spectrometry data must be spectrally, radiometrically and geometrically calibrated in order to: 1) derive physical parameters from measured spectral radiance, 2) compare data acquired from different regions and at different times, 3) compare and analyze the imaging spectrometry data with data acquired from other calibrated sensors, and 4) compare and analyze data with results from computer models. The calibration of AVIRIS data is the process by which laboratory characterization data are applied to raw instrument data (digitized number versus spectral channels) to produce quantitative spectra (radiance versus wavelength) for each image pixel in units of spectral radiance. The AVIRIS sensor and calibration process are described by Vane and the application of the calibration data to the raw digital data is described by Green. This calibration process is validated for in-flight performance of the sensor using a rigorous ground-truth campaign. This workshop paper reviews the laboratory characterization data set that is used in the AVIRIS calibration process. The laboratory measurements used to acquire the calibration data are divided into three classes: 1) spectral calibration, 2) radiometric calibration, and 3) spatial calibration.

Green Robert O.↗

Calibration and Validation of a Finite ELement Model of THor-K Anthropomorphic Test Device for Aerospace Safety Applications

The THOR anthropomorphic test device (ATD) has been developed and continuously improved by the National Highway Traffic Safety Administration to provide automotive manufacturers an advanced tool that can be used to assess the injury risk of vehicle occupants in crash tests. Recently, a series of modifications were completed to improve the biofidelity of THOR ATD [1]. The updated THOR Modification Kit (THOR-K) ATD was employed at Wright-Patterson Air Base in 22 impact tests in three configurations: vertical, lateral, and spinal [2]. Although a computational finite element (FE) model of the THOR had been previously developed [3], updates to the model were needed to incorporate the recent changes in the modification kit. The main goal of this study was to develop and validate a FE model of the THOR-K ATD. The CAD drawings of the THOR-K ATD were reviewed and FE models were developed for the updated parts. For example, the head-skin geometry was found to change significantly, so its model was re-meshed (Fig. 1a). A protocol was developed to calibrate each component identified as key to the kinematic and kinetic response of the THOR-K head/neck ATD FE model (Fig. 1b). The available ATD tests were divided in two groups: a) calibration tests where the unknown material parameters of deformable parts (e.g., head skin, pelvis foam) were optimized to match the data and b) validation tests where the model response was only compared with test data by calculating their score using CORrelation and Analysis (CORA) rating system. Finally, the whole ATD model was validated under horizontal-, vertical-, and lateral-loading conditions against data recorded in the Wright Patterson tests [2]. Overall, the final THOR-K ATD model developed in this study is shown to respond similarly to the ATD in all validation tests. This good performance indicates that the optimization performed during calibration by using the CORA score as objective function is not test specific. Therefore confidence is provided in the ATD model for uses in predicting response in test conditions not performed in this study such those observed in the spacecraft landing. Comparison studies with ATD and human models may also be performed to contribute to future changes in THOR ATD design in an effort to improve its biofidelity, which has been traditionally based on post-mortem human subject testing and designer experience.

Putnam, J. B.↗

MODIS Pre-launch and On-orbit Calibration

Two nearly identical MODIS instruments are currently operated on-orbit: one on-board the EOS Terra spacecraft launched in December 1999 and the other on-board the Aqua spacecraft launched in May 2002. Both sensors went through extensive pre-launch calibration and characterization activities that had provided many critically important parameters and sensor characteristics in support of their on-orbit operation and calibration. On-orbit each MODIS instrument is calibrated and characterized via a set of on-board calibrators (OBC) that include a solar diffuser (SD), a solar diffuser stability monitor (SDSM), a blackbody (BB), and a spectroradiometric calibration assembly (SRCA). This paper provides an overview of MODIS calibration and characterization methodologies and measurements performed, pre-launch and on-orbit, for both the reflective solar bands (RSB) and thermal emissive bands (TEB). It discusses issues on the calibration transfer from ground to on-board and from pre-launch to on-orbit, and illustrates the calibration consistency between Terra and Aqua MODIS. Examples in three key areas, radiometric, spatial, and spectral, are presented. Also addressed in the paper are the challenges and lessons learned during MODIS pre-launch and on-orbit calibration and performance.

Xiong, X.↗

C-band radar calibration using GEOS-3

The various methods of determining tracking radar measurement error parameters are described, along with the projected accuracy of results. Typical examples and results for calibration of radars tracking the GEOS-3 satellite are presented.

Krabill, W. B.↗

The Badhwar-O'Neill 2020 Model

The Badhwar-O'Neill (BON) model has been used for some time to describe the galactic cosmic ray (GCR) environment encountered in deep space by astronauts and sensitive electronics. The most recent version of the model, BON2014, was calibrated to available measurements to reduce model errors for particles and energies of significance to astronaut exposure. Although subsequent studies showed the model to be reasonably accurate for such applications, modifications to the sunspot number (SSN) classification system and a large number of new high precision measurements suggested the need to develop an improved and more capable model. In this work, the BON2020 model is described. The new model relies on daily integral flux from the Advanced Composition Explorer Cosmic Ray Isotope Spectrometer (ACE/CRIS) to describe solar activity. For time periods not covered by ACE/CRIS, the updated international SSN database is used. Parameters in the new model are calibrated to available data, which includes the new Alpha Magnetic Spectrometer (AMS-02) and Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics (PAMELA) high-precision measurements. It is found that the BON2020 model is a significant improvement over BON2014. Systematic errors associated with BON2014 have been removed. The average relative error of the BON2020 model compared to all available measurements is found to be <1%, and BON2020 is found to be within ±15% of a large fraction of the available measurements (26,269 of 27,646 → 95%).

Slaba, Tony C.↗

The Badhwar-O'Neill 2020 Model

The Badhwar-O’Neill (BON) model has been used for some time to describe the galactic cosmic ray (GCR) environment encountered in deep space by astronauts and sensitive electronics. The most recent version of the model, BON2014, was calibrated to available measurements to reduce model errors for particles and energies of significance to astronaut exposure. Although subsequent studies showed the model to be reasonably accurate for such applications, modifications to the sunspot number (SSN) classification system and a large number of new high-precision measurements suggested the need to develop an improved and more capable model. In this work, the BON2020 model is described. The new model relies on daily integral flux from the Advanced Composition Explorer Cosmic Ray Isotope Spectrometer (ACE/CRIS) to describe solar activity. For time periods not covered by ACE/CRIS, the updated international SSN database is used. Parameters in the new model are calibrated to available data, which includes the new Alpha Magnetic Spectrometer (AMS-02) and Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics (PAMELA) high-precision measurements. It is found that the BON2020 model is a significant improvement over BON2014. Systematic errors associated with BON2014 have been removed. The average relative error of the BON2020 model compared to all available measurements is found to be <1%, and BON2020 is found to be within +15% of a large fraction of the available measurements (26,269 of 27,646  95%.

T C Slaba↗

Tracking system analytic calibration activities for the Mariner Mars 1971 mission

This report describes the functions of the Tracking System Analytic Calibration activity for Mariner Mars 1971 (MM'71), its objectives for this and future missions, and the support provided to the MM'71 Navigation Team during operations. The support functions encompass calibration of tracking data by estimating physical parameters whose uncertainties represent limitations to navigational accuracy, and detailed analysis of the tracking data to uncover and resolve any anomalies. Separate articles treat the activities and results of producing calibrations for the various error sources: Deep Space Station Locations, timing and polar motion, charged particles, and the troposphere. Two other articles are also included dis- - cussing the effects of the media error sources on orbit determination and the merits of the smoothing technique used for DRIVID.

Facilities↗

The tracking system analytic calibration activity for Mariner Mars 1971: Its function and scope

The functions of the Tracking System Analytic Calibration activity for Mariner Mars 1971 (MM'71), its objectives for this and future missions, and the support provided to the MM'71 Navigation Team during operations are described. Support functions encompass calibration of tracking data by estimating physical parameters whose uncertainties represent limitations to navigational accuracy, and detailed analysis of the tracking data to uncover and resolve any anomalies. Separate articles treat the activities and results of producing calibrations for the various error sources: Deep Space Station Locations, timing and polar motion, charged particles, and the troposphere. Two other articles are also included discussing the effects of the media error sources on orbit determination and the merits of the smoothing technique used for DRIVID.

Madrid, G. A.↗

Inferring Structural Parameters of Low-Surface-Brightness-Galaxies with Uncertainty Quantification using Bayesian Neural Networks

Measuring the structural parameters (size, total brightness, light concentration, etc.) of galaxies is a significant first step towards a quantitative description of different galaxy populations. In this work, we demonstrate that a Bayesian Neural Network (BNN) can be used for the inference, with uncertainty quantification, of such morphological parameters from simulated low-surface-brightness galaxy images. Compared to traditional profile-fitting methods, we show that the uncertainties obtained using BNNs are comparable in magnitude, well-calibrated, and the point estimates of the parameters are closer to the true values. Our method is also significantly faster, which is very important with the advent of the era of large galaxy surveys and big data in astrophysics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated Probabilistic Finite Element Model Calibration Tool Based on Uncertainty Quantification and Machine Learning

Qualification and certification of safety critical parts is a hurdle to the adoption of metallic additively manufactured components for aerospace vehicle applications. Challenges include variability in part properties due to inconsistent defect distribution and microstructure. Understanding of the process through finite element modeling (FEM), and process control through in-situ monitoring, may result in significant improvements; however, solutions useful to manufacturers will require large volumes of data and automated data utilization. Toward this end, a generalizable automated FEM calibration paradigm is developed. This paradigm leverages existing and novel tools from machine learning and uncertainty quantification to enable the automatic calibration of FEMs without requiring prior knowledge of the model performance across input parameter space, including meshing and solver settings, which can require time consuming manual model probing or cause noisy and inconsistent predictions. The result is a probabilistic distribution of calibrated and validated FEM input parameters targeting measured data.

Additive manufacturing model calibration finite el↗

Simultaneous inference of the compressibility and inelastic response of tantalum under extreme loading

We study the deformation of tantalum under extreme loading conditions. Experimental velocity data are drawn from both ramp loading experiments on Sandia’s Z-machine and gas gun compression experiments. The drive conditions enable the study of materials under pressures greater than 100 GPa. We provide a detailed forward model of the experiments including a model of the magnetic drive for the Z-machine. Utilizing these experiments, we simultaneously infer several different types of physically motivated parameters describing equation of state, plasticity, and anelasticity via the computational device of Bayesian model calibration. Characteristics of the resulting calculated posterior distributions illustrate relationships among the parameters of interest via the degree of cross correlation. The calibrated velocity traces display good agreement with the experiments up to experimental uncertainty as well as improvement over previous calibrations. Examining the Z-shots and gun-shots together and separately reveals a trade-off between accuracy and transferability across different experimental conditions. Implications for model calibration, limitations from model form, and suggestions for improvements are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗