Solid optical ring interferometer for high-throughput feedback-free spectral analysis and filtering

We describe a simple and inexpensive optical ring interferometer for use in high-resolution spectral analysis and filtering. It consists of a solid cuboid, reflection-coated on two opposite sides, in which constructive interference occurs for waves in a rhombic trajectory. Due to its monolithic design, the interferometer’s resonance frequencies are insensitive to environmental disturbances over time. Additional advantages are its simplicity of alignment, high-throughput, and feedback-free operation. If desired, it can be stabilized with a secondary laser without disturbance of the primary signal. We illustrate the use of the interferometer for the measurement of the spectral Mollow triplet from a quantum dot and characterize its long-term stability for filtering applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bragg grating inscription in photosensitive materials by an optical replication process

This paper examines the feasibility of producing multiplexed Bragg gratings for use as diffractive optical elements (DOEs) by coherent optical replication of a surface-relief phase grating into thick-film photosensitive materials. The use of such DOEs in light guide plates (LGPs) for optical imaging systems ensures energy-efficient light input into and output from LGPs and allows one to minimise their weight and size. We present simulation results for the interference structure fabrication process and recording of a series of multiplexed diffraction gratings in photosensitive materials. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The fast camera (Fastcam) imaging diagnostic systems on the DIII-D tokamak

Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data analysis workflow, particularly for intensity calibration. Here, the spatial calibration uses multiple observable wall features, resulting in a reconstruction accuracy ≤2 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Uncovering surface plasmon optical resonances in nanohole arrays through interferometric photoemission electron microscopy

In this work, the role of surface plasmon polaritons (SPPs) in nanohole array optical extinction spectra is explored using a time-resolved technique capable of isolating the air/metal interfacial SPP contribution to the typical Fano profile in optical transmission curves. A pair of interferometrically locked broad-band femtosecond pulses is used to launch SPPs from lithographically patterned plasmonic nanohole arrays. SPPs launched in the co- and counter-propagating directions are probed using a third probe pulse in a photoemission electron microscope. Using this approach, we record interferometric SPP–SPP linear autocorrelations that selectively report on the resonances of SPPs launched from arrays of varying pitches and hole diameters. Aside from advancing an approach to selective SPP spectroscopy, we illustrate that resonant coupling in the counter-propagating direction may be exploited to control the spatial, temporal, and spectral characteristics of SPPs. For the counter-propagating direction, we show that tuning the array pitch near the fundamental plasmon resonance generates color-tuned (~770–820 nm), narrow bandwidth SPPs, and the bandwidth may be controlled by changing the ratio of pitch to hole diameter. The SPP resonances we recover through Fourier transforms of the interferometric autocorrelations shed light on the classical problem of Fano interference in nanohole array extinction spectra.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

APPLICATION OF ABSORPTION SPECTROSCOPY TO ACTINIDE PROCESS ANALYSIS AND MONITORING

The characteristic strong colors of aqueous actinide solutions form the basis of analytical techniques for actinides based on absorption spectroscopy. Colorimetric measurements of samples from processing activities have been used for at least half a century. This seemingly mature technology has been recently revitalized by developments in chemometric data analysis. Where reliable measurements could formerly only be obtained under well-defined conditions, modern methods are robust with respect to variations in acidity, concentration of complexants and spectral interferents, and temperature. This paper describes two examples of the use of process absorption spectroscopy for Pu analysis at the Savannah River Site, in Aiken, SC. In one example, custom optical filters allow accurate colorimetric measurements of Pu in a stream with rapid nitric acid variation. The second example demonstrates simultaneous measurement of Pu and U by chemometric treatment of absorption spectra. The paper concludes with a description of the use of these analyzers to supplement existing technologies in nuclear materials monitoring in processing, reprocessing, and storage facilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental generation of single photons via active multiplexing

An on-demand single-photon source is a fundamental building block in quantum science and technology. We experimentally demonstrate the proof of concept for a scheme to generate on-demand single photons via actively multiplexing several heralded photons probabilistically produced from pulsed spontaneous parametric down-conversions (SPDCs). By utilizing a four-photon-pair source, an active feed-forward technique, and an ultrafast single-photon router, we show a fourfold enhancement of the output photon rate. Simultaneously, we maintain the quality of the output single-photon states, confirmed by correlation measurements. We also experimentally verify, via Hong-Ou-Mandel interference, that the router does not affect the indistinguishability of the single photons. Furthermore, we give numerical simulations, which indicate that photons based on multiplexing of four SPDC sources can outperform the heralding based on highly advanced photon-number-resolving detectors. Our results show a route for on-demand single-photon generation and the practical realization of scalable linear optical quantum-information processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

From a discrete to a continuous model for interpulse interference with a frequency-comb laser

We have investigated correlation patterns generated by a frequency-comb laser in a dispersive unbalanced Michelson interferometer and apply the developed formalism to the case of distance metrology. Due to group velocity dispersion, the position of the brightest fringe of the correlation pattern, which is used for distance determination, cannot be derived by simply using the definition of group refractive index of the dispersive medium. It is shown that the discrete spectrum of the optical frequency comb gives rise to correlation functions which can be represented by a series, namely a discrete correlation series. We have developed a general formalism, valid for any pulse train, extending the discrete model to a continuous model of cross-correlation functions using the Poisson summation. Our model is relevant for any offset and repetition frequency of the frequency comb. From the continuous cross-correlation model we show that, even for a homogeneous dispersive medium the position of the brightest fringe varies nonlinearly for small delay distances and stabilizes for longer ones. We have compared the theoretical results to measurements of pulse propagation in air for path-lengths up to 200 m.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Molecular high-order harmonic generation with more than one active orbital: Quantum interference effects

We investigate quantum interference effects in high-order harmonic generation in N{sub 2} and N{sub 2}{sup +} beyond the single-active-orbital approximation, with particular emphasis on the role of {sigma} and {pi} orbitals in the overall spectra. In the former case, we consider a simplified multielectron wave function which incorporates the 3{sigma}{sub g} and 1{pi}{sub u} orbitals, and, in the latter, we assume that the optically active electron is in a coherent superposition of the 3{sigma}{sub g} and 1{pi}{sub g}{sup *} one-electron states. If the orbitals are energetically close, such as the 3{sigma}{sub g} and the 1{pi}{sub u} orbitals of N{sub 2}, we show that the quantum interference patterns observed in the high-order harmonic spectra are predominantly determined by the 3{sigma}{sub g} orbital. If, on the other hand, there is a significant difference in their binding energies, such as for the 3{sigma}{sub g} and the 1{pi}{sub g}{sup *} orbitals of N{sub 2}{sup +}, the most loosely bound orbital will determine the shape of the spectra. Due, however, to the different cutoffs encountered, the more deeply bound orbital will leave an imprint on the high-energy harmonics. This holds both for the situation in which the dynamics of the electron is restricted to the plane p{sub x}p{sub z} and for the full three-dimensional case, if the azimuthal angle is integrated over and the degeneracy of the {pi} orbitals is taken into account.

74 ATOMIC AND MOLECULAR PHYSICS↗

A prototype, glassless densitometer traceable to primary optical standards for quantitative radiochromic film dosimetry

Purpose: To evaluate a prototype densitometer traceable to primary optical standards and compare its performance to an EPSON Expression{sup ®} 10000XL flatbed scanner (the Epson) for quantitative radiochromic film (RCF) dosimetry. Methods: A prototype traceable laser densitometry system (LDS) was developed to mitigate common film scanning artifacts, such as positional scan dependence and high noise in low-dose regions, by performing point-based measurements of RCF suspended in free-space using coherent light. The LDS and the Epson optical absorbance scales were calibrated up to 3 AU, using reference materials calibrated at a primary standards laboratory and a scanner calibration factor (SCF). Calibrated optical density (OD) was determined for 96 Gafchromic{sup ®} EBT3 film segments before and after irradiation to one of 16 dose levels between 0 and 10 Gy, exposed to {sup 60}Co in a polymethyl-methacrylate (PMMA) phantom. The sensitivity was determined at each dose level and at two rotationally orthogonal readout orientations to obtain the sensitometric response of each RCF dosimetry system. LDS rotational scanning dependence was measured at nine angles between 0°and 180°, due to the expected interference between coherent light and polarizing EBT3 material. The response curves were fit to the analytic functions predicted by two physical response models: the two-parameter single-hit model and the four-parameter percolation model. Results: The LDS and the Epson absorbance measurements were linear to primary optical standards to within 0.2% and 0.3% up to 2 and 1 AU, respectively. At higher densities, the LDS had an over-response (2.5% at 3 AU) and the Epson an under-response (3.1% and 9.8% at 2 and 3 AU, respectively). The LDS and the Epson SCF over the applicable range were 0.968% ± 0.2% and 1.561% ± 0.3%, respectively. The positional scan dependence was evaluated on each digitizer and shown to be mitigated on the LDS, as compared to the Epson. Maximum EBT3 rotational dependence was found to have a strong dependence on dose (0.1% and 34% at 30 mGy and 5 Gy, respectively). The preferred EBT3 polymerization axis angle was constant within experimental uncertainties. In its most sensitive orientation, the LDS-measured EBT3 sensitivity was 7.13 × 10{sup −4} ± 9.2 × 10{sup −6} AU/mGy, which represented a 4.5 fold increase over the Epson of 1.58 × 10{sup −4} ± 9.8 × 10{sup −6} AU/mGy. To first order approximations, EBT3 response was linear up to 500 mGy to within 0.80% and to within 7.5% for the most sensitive LDS and the Epson orientations, respectively. The corresponding single-hit and percolation model relative residual norms were 0.082 and 0.074 for LDS as compared to 0.29 and 0.18 for the Epson, which represented a significant increase in LDS-measured agreement with the simple physical model. Less sensitive LDS and the Epson orientations showed a marked decrease in the physical model agreement, which suggested that suboptimal readout device characteristics may be the origin of the complex sensitometric functional forms currently required for accurate RCF dosimetry. Conclusions: The prototype densitometer was shown to be superior to a conventional scanner for quantitative RCF dosimetry based on physical models of film response. The Epson was shown to be a reliable tool for routine RCF dosimetry in a clinical setting, yet calibration to primary optical standards did not mitigate the necessity for complex, empirical functional form fitting.

60 APPLIED LIFE SCIENCES↗

Towards fully self-consistent optoelectronic simulation of planar devices

Photon recycling plays an important role in various optoelectronic devices, such as thin-film solar cells and intracavity double-diode structures presently studied for electroluminescent cooling. However, a complete description of photon recycling requires developing fully self-consistent simulation tools of photon and electronic charge transport in realistic device structures. In this paper, we describe a possible route towards such simulation tools in planar devices by combining the radiative transfer (RT) equation of photon transport with the drift-diffusion (DD) equations of electron and hole dynamics. We investigate the feasibility of the approach by selected proof-of-principle device studies. The results indicate that combining the RT and DD models not only yields the expected device characteristics, but also produces new insight into the pertinent local emission and absorption properties within the device structures. In particular, the model allows to accurately investigate how emission directivity and saturation affect the coupling coefficient in the double diode structures, showing that the main contribution to the coupling coefficient arises from the reflectivity of the top contact. For completeness, we also discuss how interference affects photon transport in resonant devices by an example calculation using the quantized fluctuational electrodynamics framework, paving way for self-consistent modeling tools that also account for wave-optical effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The FRAM robotic telescope for atmospheric monitoring at the Pierre Auger Observatory

FRAM (F/Photometric Robotic Atmospheric Monitor) is a robotic telescope operated at the Pierre Auger Observatory in Argentina for the purposes of atmospheric monitoring using stellar photometry. As a passive system which does not produce any light that could interfere with the observations of the fluorescence telescopes of the observatory, it complements the active monitoring systems that use lasers. We discuss the applications of stellar photometry for atmospheric monitoring at optical observatories in general and the particular modes of operation employed by the Auger FRAM. We describe in detail the technical aspects of FRAM, the hardware and software requirements for a successful operation of a robotic telescope for such a purpose and their implementation within the FRAM system.

Optics↗

Chromatic interferometry with small frequency differences

By developing a ‘two-crystal’ method for color erasure, we can broaden the scope of chromatic interferometry to include optical photons whose frequency difference falls outside of the 400 nm to 4500 nm wavelength range, which is the passband of a PPLN crystal. We demonstrate this possibility experimentally, by observing interference patterns between sources at 1064.4 nm and 1063.6 nm, corresponding to a frequency difference of about 200 GHz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Fano-type transmission and field enhancement in heterostructures composed of epsilon-near-zero materials and truncated photonic crystals

The Fano-type interference effect is studied in the heterostructure composed of an epsilon-near-zero (ENZ) material and a truncated photonic crystal for transverse magnetic polarized light. In the Fano-type interference effect, the ENZ material provides narrow reflection pathway and the photonic crystal provides broadband reflection pathway. The boundary condition across the ENZ interface and the confinement effect provided by the photonic crystal can enhance the electric fields in the ENZ material greatly. The field enhancements, together with the asymmetric property of Fano-type spectrum, possess potential applications for significantly lowering the threshold of nonlinear processes such as optical switching and bistability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Post-Deposition Induced Conductivity in Pulsed Laser Irradiated Metal Doped Zinc Oxide Films

The optical and electrical properties of doped solution-deposited and rf sputter-deposited thin metal oxide films were investigated following post deposition pulsed laser irradiation. Solution deposited films were annealed at 450 ºC. Following the heating regiment, the transparent metal oxide films were subjected to 355 nm pulsed Nd:YAG laser irradiation (4 nsec pulsewidth) at fluences between 5 and 150 mJ/cm2. Irradiation times at pulse frequencies of 30 Hz ranged from seconds to tens of minutes. Film densification, index change and a marked increase in conductivity were observed following irradiation in air and under vacuum of Al:ZnO (AZO), Ga:ZnO (GZO), and In:ZnO (IZO) films deposited on silica substrates. Despite the measured increase in conductivity, all films continued to show high transparency on the order of 90% at wavelengths from the band edge well into the near infrared region of the spectrum. Laser energies required for turning on the conductivity of these films varied depending upon the dopant. Irradiations in air yielded resistivity measurements on the order of 16.cm. Resistivities of films irradiated under vacuum were on the order of 0.1.cm. The increase in conductivity can be attributed to the formation of oxygen vacancies and subsequent promotion of free carriers into the conduction band. All irradiated films become insulating after around 24 hours. Oxygen atoms in air become reduced by electrons in the metal conduction band and diffuse into the vacancies in the lattice. The rate of this reduction process depends on the type of dopant. This work also sheds light on the damage threshold, correlating the optical properties with the presence of free carriers that have been introduced into the conduction band. All films were characterized by means of UV-VIS-NIR transmission spectroscopy, visible and UV Raman spectroscopy and Hall measurements. Analysis of interference fringes in measured transmission spectra allowed film density and refractive index to be evaluated while the Raman measurements showed an increase in LO mode intensity with respect to the TO mode intensity as the films became more conducting. Results of this study are not only important for the continued development of transparent conducting oxide films that find use in photovoltaic cells and solid state lighting modules, but also provide evidence for the role of free carriers in initiating the laser damage process in these wide bandgap metal oxide films.

14 SOLAR ENERGY↗

Generalized acceleration theorem for spatiotemporal Bloch waves

A representation is put forward for wave functions of quantum particles in periodic lattice potentials subjected to homogeneous time-periodic forcing, based on an expansion with respect to Bloch-like states which embody both the spatial and the temporal periodicity. It is shown that there exists a generalization of Bloch's famous acceleration theorem which grows out of this representation and captures the effect of a weak probe force applied in addition to a strong dressing force. Taken together, these elements point at a ''dressing and probing'' strategy for coherent wave-packet manipulation, which could be implemented in present experiments with optical lattices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Talbot effect beyond the paraxial limit at optical frequencies

This paper reports the experimental and theoretical investigation of the Talbot effect beyond the paraxial limit at optical frequencies. Au hole array films with periodicity 0 a comparable to the wavelength of coherent illumination λ were used to study the non-paraxial Talbot effect. Significant differences from the paraxial (classical) Talbot effect were observed. Depending on the ratio of 0 a / λ , the interference pattern in the direction perpendicular to the hole array was not necessarily periodic, and the selfimage distances deviated from the paraxial Talbot distances. Defects within the hole array film or above the film were healed in the self-images as the light propagated from the surface.

36 MATERIALS SCIENCE↗

2013 R&D 100 Award: 'SHIELD' protects NIF optics from harmful pulses

In the past, it took as long as 12 hours to manually screen 48 critical checkpoints at the National Ignition Facility (NIF) for harmful laser pulses. The screening equipment had to be moved from point to point throughout a facility the size of three football fields. Now with a new technology, called Laser SHIELD (Screening at High-throughput to Identify Energetic Laser Distortion), and with the push of a button, the screening can be done in less than one second. Proper screening of pulses is critical for the operation of high-energy lasers to ensure that the laser does not exceed safe operating conditions for optics. The energetic beams of light are so powerful that, when left uncontrolled, they can shatter the extremely valuable glass inside the laser. If a harmful pulse is found, immediate adjustments can be made in order to protect the optics for the facility. Laser SHIELD is a custom-designed high-throughput screening system built from low-cost and commercially available components found in the telecommunications industry. Its all-fiber design makes it amenable to the unique needs of high-energy laser facilities, including routing to intricate pick-off locations, immunity to electromagnetic interference and low-loss transport (up to several kilometers). The technology offers several important benefits for NIF. First, the facility is able to fire more shots in less time-an efficiency that saves the facility millions of dollars each year. Second, high-energy lasers are more flexible to wavelength changes requested by target physicists. Third, by identifying harmful pulses before they damage the laser's optics, the facility potentially saves hundreds of thousands of dollars in maintenance costs each year.

42 ENGINEERING↗

Spatially resolved measurements to improve analytical performance of solution-cathode glow discharge optical-emission spectrometry

We report past studies of the solution-cathode glow discharge (SCGD) revealed that elemental and molecular emission are not spatially homogenous throughout the source, but rather conform to specific zones within the discharge. Exploiting this inhomogeneity can lead to improved analytical performance if emission is collected only from regions of the discharge where analyte species emit strongly and background emission (from continuum, elemental and/or molecular sources) is lower. Effects of this form of spatial discrimination on the analytical performance of SCGD optical emission spectrometry (OES) have been investigated with an imaging spectrograph for fourteen atomic lines, with emphasis on detection limits and precision. Vertical profiles of the emission intensity, signal-to-background ratio, and signal-to-noise ratio were collected and used to determine the optimal region to view the SCGD on a per-element basis. With optimized spatial filtering, detection limits ranged from 0.09–360 ppb, a 1.4–13.6 fold improvement over those obtained when emission is collected from the full vertical profile (1.1– 840 ppb),with a 4.2-fold average improvement. Precision was found to be unaffected by spatial filtering, ranging from0.5–2.6% relative standard deviation (RSD) for all elements investigated, closely comparable to the 0.4–2.4% RSD observed when no spatial filtering is used. In conclusion, spatial profiles also appear useful for identifying optimal line pairs for internal standardization and for flagging the presence of matrix interferences in SCGD-OES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗