Port Hope Area Initiative: Information Management for A Very Large Radiation Survey - 19567

The Port Hope Area Initiative (PHAI) represents the Government of Canada's commitment to the cleanup and safe, local, long-term management of historic low-level radioactive waste (LLRW) in two Southern Ontario municipalities - Port Hope. The PHAI is based on community-recommended solutions for the cleanup and safe long-term management of approximately 1.7 million cubic meters of LLRW. It is currently one of Canada's largest environmental remediation projects at a cost of over one billion dollars. The PHAI is being implemented by Canadian Nuclear Laboratories (CNL) on behalf of Atomic Energy of Canada Limited, a federal Crown corporation. The waste is the result of radium and uranium processing in Port Hope by the former federal crown corporation Eldorado Nuclear Limited between 1933 and 1988. The waste has been distributed in the Municipality of Port Hope through placement of contaminated materials (e.g. fill), reuse of contaminated objects (e.g. tailings use in concrete, steel posts, structural wood) and air-borne deposition. Signature contaminants of potential concern (COPCs) are Ra-226, Th-230, uranium and arsenic; however, there are an additional 17 COPCs that also need to be considered. A very large amount of information has been collected during the survey and effectively managing and analyzing this information is critical to the success for the property owners, CNL's implementation of the PHAI, and Arcadis. Data collected during the survey includes information pertaining to long-term interior radon gas measurements, interior gamma radiation surveys, contaminated objects and surfaces, exterior gamma radiation and subsurface investigations. exterior gamma radiation surveys. The information management (IM) is structured with SharePoint as a focal point supported by an EQuIS database, mobile data collection and GIS support. The IM process for this project is being advanced using recent software developments to assist with internal activities (e.g. QA) and interactions with CNL including notifications and scheduling and status of property completion. Different applications have been developed to help automate, visualize, actively track, and QA different processes using recent software developments by Microsoft. We have used SharePoint to organize and track our data. Power BI has been used to actively track and visualize our data from Interior gamma surveying to exterior drilling. The creation of dynamic/advanced visualizations in Power BI gathers data daily from our multiple sources and analyzes it for anomalous data and trends. Microsoft Flow syncs with Power BI and has been implemented to automate many processes including the QA of surveys and soil results for identification of LLRW. To tie everything together, our GIS and EQuIS systems are our primary data compilation source that makes our advanced analytics/visualization and automation/tracking our data possible. Specific examples will be discussed, as will challenges encountered during the continuing development of the IM system. The incorporation of software advancements to the existing IM system for Port Hope characterization has improved the quality of the surveys, the tracking of completion, meeting schedule requirements and providing the required data for tracking, report preparation and supporting remediation of contamination on the properties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Further work on credible levels of water moderation - 14267

The Research and Test Reactor (RTR) manufacturing operation produces aluminum clad fuel plates that are assembled into 'box type' elements that are used in reactors like the Advanced Test Reactor, University of Missouri, and Massachusetts Institute of Technology. These fuel plates and elements are stored in both horizontal and vertical arrangements during the manufacturing process. Since the presence of water is so important to criticality safety of the operations, a study was undertaken to establish credible levels of water moderation. At the NCSD 2013 Topical meeting, credible levels of interspersed water moderation from multiple sources including firefighting, steam and rain were presented. This covered the initial portions of the research. Subsequent research was conducted on water films resulting from these water sources. This phase of the research involved the formation of water films. These can form from condensation, water sprays or immersion. The thickness of the water films from these sources ranged from 0.04 cm to 0.30 cm for vertical fuel plates. Studies were also conducted on horizontal plates, stacks of plates and assembled elements. For fuel plates, the films ranged from essentially zero for stacked plates to 0.25 cm. For an element, there was sufficient adhesion that all of the channels were filled. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Tracing the HIV-1 subtype B mobility in Europe: a phylogeographic approach

The prevalence and the origin of HIV-1 subtype B, the most prevalent circulating clade among the long-term residents in Europe, have been studied extensively. However the spatial diffusion of the epidemic from the perspective of the virus has not previously been traced. In the current study we inferred the migration history of HIV-1 subtype B by way of a phylogeography of viral sequences sampled from 16 European countries and Israel. Migration events were inferred from viral phylogenies by character reconstruction using parsimony. With regard to the spatial dispersal of the HIV subtype B sequences across viral phylogenies, in most of the countries in Europe the epidemic was introduced by multiple sources and subsequently spread within local networks. Poland provides an exception where most of the infections were the result of a single point introduction. According to the significant migratory pathways, we show that there are considerable differences across Europe. Specifically, Greece, Portugal, Serbia and Spain, provide sources shedding HIV-1; Austria, Belgium and Luxembourg, on the other hand, are migratory targets, while for Denmark, Germany, Italy, Israel, Norway, the Netherlands, Sweden, Switzerland and the UK we inferred significant bidirectional migration. For Poland no significant migratory pathways were inferred. Subtype B phylogeographies provide a new insight about the geographical distribution of viral lineages, as well as the significant pathways of virus dispersal across Europe, suggesting that intervention strategies should also address tourists, travellers and migrants.

59 BASIC BIOLOGICAL SCIENCES↗

Biological Network Inference and Analysis using SEBINI and CABIN

Attaining a detailed understanding of the various biological networks in an organism lies at the core of the emerging discipline of systems biology. A precise description of the relationships formed between genes, mRNA molecules, and proteins is a necessary step toward a complete description of the dynamic behavior of an organism at the cellular level; and towards intelligent, efficient and directed modification of an organism. The importance of understanding such regulatory, signaling, and interaction networks has fueled the development of numerous in silico inference algorithms, as well as new experimental techniques and a growing collection of public databases. The Software Environment for BIological Network Inference (SEBINI) has been created to provide an interactive environment for the deployment, evaluation, and improvement of algorithms used to reconstruct the structure of biological regulatory and interaction networks. SEBINI can be used to analyze high-throughput gene expression, protein expression, or protein activation data via a suite of state-of-the-art network inference algorithms. It also allows algorithm developers to compare and train network inference methods on artificial networks and simulated gene expression perturbation data. SEBINI can therefore be used by software developers wishing to evaluate, refine, or combine inference techniques, as well as by bioinformaticians analyzing experimental data. Networks inferred from the SEBINI software platform can be further analyzed using the Collective Analysis of Biological Interaction Networks (CABIN) tool, which is exploratory data analysis software that enables integration and analysis of protein-protein interaction and gene-to-gene regulatory evidence obtained from multiple sources. The collection of edges in public databases, along with the confidence held in each edge (if available), can be fed into CABIN as one “evidence network”, using the Cytoscape SIF file format. Using CABIN, one may increase the confidence in individual edges in a network inferred by an algorithm in SEBINI, as well as extend such a network by combining it with species-specific or generic information; e.g., known protein-protein interactions or target genes identified for known transcription factors. Thus, the combined SEBINI–CABIN toolkit aids in the more accurate reconstruction of biological networks, with less effort, in less time. A demonstration web site for SEBINI can be accessed from https://www. emsl.pnl.gov/NIT/NIT.html. Source code and PostgreSQL database schema are available under open source license. Contact: ronald.taylor@pnl.gov. For commercial use, some algorithms included in SEBINI require licensing from the original developers. CABIN can be downloaded from http://www.sysbio.org/dataresources/cabin.stm. Contact: mudita.singhal@pnl.gov.

59 BASIC BIOLOGICAL SCIENCES↗

AN ALMA SURVEY OF SUBMILLIMETER GALAXIES IN THE EXTENDED CHANDRA DEEP FIELD SOUTH: SOURCE CATALOG AND MULTIPLICITY

We present an Atacama Large Millimeter/submillimeter Array (ALMA) Cycle 0 survey of 126 submillimeter sources from the LABOCA ECDFS Submillimeter Survey (LESS). Our 870 {mu}m survey with ALMA (ALESS) has produced maps {approx}3 Multiplication-Sign deeper and with a beam area {approx}200 Multiplication-Sign smaller than the original LESS observations, doubling the current number of interferometrically-observed submillimeter sources. The high resolution of these maps allows us to resolve sources that were previously blended and accurately identify the origin of the submillimeter emission. We discuss the creation of the ALESS submillimeter galaxy (SMG) catalog, including the main sample of 99 SMGs and a supplementary sample of 32 SMGs. We find that at least 35% (possibly up to 50%) of the detected LABOCA sources have been resolved into multiple SMGs, and that the average number of SMGs per LESS source increases with LESS flux density. Using the (now precisely known) SMG positions, we empirically test the theoretical expectation for the uncertainty in the single-dish source positions. We also compare our catalog to the previously predicted radio/mid-infrared counterparts, finding that 45% of the ALESS SMGs were missed by this method. Our {approx}1.''6 resolution allows us to measure a size of {approx}9 kpc Multiplication-Sign 5 kpc for the rest-frame {approx}300 {mu}m emission region in one resolved SMG, implying a star formation rate surface density of 80 M{sub Sun} yr{sup -1} kpc{sup -2}, and we constrain the emission regions in the remaining SMGs to be <10 kpc. As the first statistically reliable survey of SMGs, this will provide the basis for an unbiased multiwavelength study of SMG properties.

79 ASTRONOMY AND ASTROPHYSICS↗

Multiple species beam production on laser ion source for electron beam ion source in Brookhaven National Laboratory

Extracted ion beams from the test laser ion source (LIS) were transported through a test beam transport line which is almost identical to the actual primary beam transport in the current electron beam ion source apparatus. The tested species were C, Al, Si, Cr, Fe, Cu, Ag, Ta, and Au. The all measured beam currents fulfilled the requirements. However, in the case of light mass ions, the recorded emittance shapes have larger aberrations and the RMS values are higher than 0.06 π mm mrad, which is the design goal. Since we have margin to enhance the beam current, if we then allow some beam losses at the injection point, the number of the single charged ions within the acceptance can be supplied. For heaver ions like Ag, Ta, and Au, the LIS showed very good performance.

43 PARTICLE ACCELERATORS↗

Characterization of the neutron source term and multiplicity of a spent fuel assembly in support of NSDA safeguards of spent nuclear fuel

The gross neutron signal (GNS) is being considered as part of a fingerprinting or neutron balance approach to safeguards of spent nuclear fuel (SNF). Because the GNS is composed of many derivative components, understanding the time-dependent contribution of these derivative components is crucial to gauging the limitations of these approaches. The major components of the GNS are ({alpha}, n), spontaneous fission (SF), and multiplication neutrons. A methodology was developed to link MCNPX burnup output files to SOURCES4C input files for the purpose of automatically generating both the ({alpha}, n) and SF signals. Additional linking capabilities were developed to write MCNPX multiplication input files using the data obtained from the SOURCES4C output files. In this paper, the following are presented: (1) the relative contributions by source nuclide to the ({alpha}, n) signal as a function of initial enrichment/burnup/cooling time; (2) the relative contributions by source nuclide to the SF signal as a function of initial enrichment/burnup/cooling time; (3) the relative contributions by reaction type ({alpha},n vs. SF) to the GNS; and (4) the multiplication of the GNS as a function of initial enrichment/burnup/cooling time/counting environment. By developing these technologies to characterize the GNS, we can better evaluate the viability of the GNS fingerprint and neutron balance concepts for SNF.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An analytical solution to obtain the optimum source location using multiple direction finders on a spherical surface

An analytical solution is presented for determining the optimum location of a radiating source on the surface of a sphere, given multiple bearings. The bearings are assumed to have small errors of the order of 0-10 deg. The optimum location is found by minimizing the sum of the squares of the perpendicular great-circle distances from the source to the bearing lines. This is achieved analytically through an eigenvalue approach, rather than the usual iterative, numerical approach. Bearings of different weight are taken into account by approximating the distance from each direction finder to the source. The result is general and may have wide application. Since it is simple and nearly as fast as the triangulation technique for source location, it is now used in the SUNY-Albany East Coast Lightning Detection Network to compute the optimum location for lightning in real time.

Orville, Richard E., Jr.↗

Fault Slip and Fluid Flow: Seismic Source Analysis to Assess Role of Multiple Slip Patches in Fault Permeability

The relationship between fault reactivation, microearthquakes (MEQs), and permeability evolution during fluid injection plays a critical role in energy harvesting and waste disposal. Recent studies have demonstrated the possibility of predicting fault permeability using cumulative seismic moments of MEQs quantitatively. To understand the underlying physical processes, we conduct fault reactivation experiments using Utah FORGE granitoid and analyze acoustic emission (AE) signals generated during stepwise increases in fluid injection pressure. Frequency analysis of thousands of calibrated AE signals reveals that fault reactivation produces multiple AE source patches with millimeter-scale radii—smaller than the sample fault radius. The cumulative area of the reactivated patches covers the fault multiple times over (∼10x–50x area) for each pressure step. These findings provide mechanistic insight that measured permeability enhancement is not driven by a single large slip event, but by the sequential and interacting activation of multiple slip patches that create a continuous flow pathway.

Nurshal, M. E. M. [Pennsylvania State University, ↗

3-D Volumetric Gamma-ray Imaging and Source Localization with a Mobile Robot - 18124

Radiation detection has largely been a manual inspection process with point sensors such as Geiger-Muller counters and scintillation spectrometers to date. While their observations of source proximity prove useful, they lack the directional information necessary for efficient source localization and characterization in cluttered environments with multiple radiation sources. The recent commercialization of Compton gamma cameras provides directional information to the broader radiation detection community for the first time. This paper presents the integration of a Compton gamma camera with a self-localizing ground robot for accurate 3D radiation mapping. Using the position and orientation of the robot, radiation images from the gamma camera are accumulated over a traversed path in a shared frame of reference to construct a consistent voxel grid-based radiation map. The peaks of the map at pre-specified energy windows are selected as the source location estimates, which are compared to the ground truth source locations. The proposed approach localizes multiple sources to within an average of 0.2 m in two 5 x 4 m{sup 2} and 14 x 6 m{sup 2} laboratory environments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flow Analysis Tool White Paper

Faster networks are continually being built to accommodate larger data transfers. While it is intuitive to think that implementing faster networks will result in higher throughput rates, this is often not the case. There are many elements involved in data transfer, many of which are beyond the scope of the network itself. Although networks may get bigger and support faster technologies, the presence of other legacy components, such as older application software or kernel parameters, can often cause bottlenecks. Engineers must be able to identify when data flows are reaching a bottleneck that is not imposed by the network and then troubleshoot it using the tools available to them. The current best practice is to collect as much information as possible on the network traffic flows so that analysis is quick and easy. Unfortunately, no single method of collecting this information can sufficiently capture the whole endto- end picture. This becomes even more of a hurdle when large, multi-user systems are involved. In order to capture all the necessary information, multiple data sources are required. This paper presents a method for developing a flow analysis tool to effectively collect network flow data from multiple sources and provide that information to engineers in a clear, concise way for analysis. The purpose of this method is to collect enough information to quickly (and automatically) identify poorly performing flows along with the cause of the problem. The method involves the development of a set of database tables that can be populated with flow data from multiple sources, along with an easyto- use, web-based front-end interface to help network engineers access, organize, analyze, and manage all the information.

Boscia, Nichole K.↗

SU-E-T-223: Investigation of the Accuracy of Two-Dimensional Dose Distributions Measurement From High-Dose-Rate Brachytherapy Ir-192 Source Using Multiple-Diode-Array Detector (MapCheck2)

Purpose: To investigate the dosimetric accuracy of multiple-diode-array detector (Mapcheck2) for high-dose-rate brachytherapy Ir-192 source. The two-dimensional (2D) dose distributions measured with MapCheck2 were validated with EBT2 Gafchromic film measurement and AAPM task-group- 43 (TG-43) modeling. Methods: 2D-dose distributions from Ir-192 source were measured with MapCheck2 and EBT2-films. MapCheck2 response was corrected for effects: directional dependence, diode and phantom heterogeneity. Optical density growth of the film was controlled by synchronized scanning of the film exposed to Ir-192 and calibration films exposed to 6 MV linac beams. Similarly, MapCheck2 response was calibrated to dose using 6 MV beams. An empirical model was developed for the dose distributions measured with Mapcheck2 that considered directional, diode and phantom heterogeneity corrections. The dose deposited in solid-state-detectors was modeled using a cavity theory model for the diode. This model was then validated with measurements using EBT2-films and calculations with TG-43. Results: The response of MapCheck2 has been corrected for different effects including: (a) directional dependence of 0–20% over angular range 0o–90o, (b) phantom heterogeneity (3%) and (c) diode heterogeneity (9%). The corrected dose distributions measured with MapCheck2 agreed well with the measured dose distributions from EBT2-film and with calculations using TG-43 within 5% over a wide range of dose levels and rates. The advantages of MapCheck2 include less noisy, linear and stable response compared with film. The response of MapCheck2 exposed to 192Ir-source showed no energy dependence similar to its response to MV energy beam. Detection spatial-resolution of individual diodes was 0.8×0.8 mm2, however, 2DMapCheck2 resolution is limited by distance between diodes (7.07 mm). Conclusion: The dose distribution measured with MapCheck2 agreed well within 5% with that measured using EBT2-films; and calculations with TG- 43. Considering correction of artifacts, MapCheck2 provides a compact, practical and accurate dosimetric tool for measurement of 2D-dose distributions for brachytherapy Ir-192.

60 APPLIED LIFE SCIENCES↗

LUMINOSITY FUNCTIONS AND POINT-SOURCE PROPERTIES FROM MULTIPLE CHANDRA OBSERVATIONS OF M81

We present an analysis of 15 Chandra observations of the nearby spiral galaxy M81 taken over the course of six weeks in 2005 May-July. Each observation reaches a sensitivity of {approx}10{sup 37} erg s{sup -1}. With these observations and one previous deeper Chandra observation, we compile a master source list of 265 point sources, extract and fit their spectra, and differentiate basic populations of sources through their colors. We also carry out variability analyses of individual point sources and of X-ray luminosity functions (XLFs) in multiple regions of M81 on timescales of days, months, and years. We find that, despite measuring significant variability in a considerable fraction of sources, snapshot observations provide a consistent determination of the XLF of M81. We also fit the XLFs for multiple regions of M81 and, using common parameterizations, compare these luminosity functions to those of two other spiral galaxies, M31 and the Milky Way.

79 ASTRONOMY AND ASTROPHYSICS↗

GDT-based neutron source with multiple-mirror end plugs

We present a new linear trap to be built at the Budker Institute. It combines gasdynamictype central cell with sloshing ions for beam fusion and the multiple-mirror end plugs for improved axial confinement. Thus it is designed as an efficient neutron source and a testbed for future development of mirror-based fusion reactors.

07 ISOTOPE AND RADIATION SOURCES↗

Can the Hypothesis 'Photon Interferes only with Itself' be Reconciled with Superposition of Light from Multiple Beams or Sources?

Any superposition effect as measured (SEM) by us is the summation of simultaneous stimulations experienced by a detector due to the presence of multiple copies of a detectee each carrying different values of the same parameter. We discus the cases with light beams carrying same frequency for both diffraction and multiple beam Fabry-Perot interferometer and also a case where the two superposed light beams carry different frequencies. Our key argument is that if light really consists of indivisible elementary particle, photon, then it cannot by itself create superposition effect since the state vector of an elementary particle cannot carry more than one values of any parameter at the same time. Fortunately, semiclassical model explains all light induced interactions using quantized atoms and classical EM wave packet. Classical physics, with its deeper commitment to Reality Ontology, was better prepared to nurture the emergence of Quantum Mechanics and still can provide guidance to explore nature deeper if we pay careful attention to successful classical formulations like Huygens-Fresnel diffraction integral.

Roychoudhuri, Chandrasekhar↗

Source localization using multiple units of a tight-pitched detector array

A system and method for determining a probability of the location of an illicit radiation source within an environment based on directional detectors. An embodiment includes a plurality of directional radiation detectors distributed about the environment and integrated with a processing unit adapted to determine the probability of the source location based on the radiation count data received from the plurality of detectors. The processing unit is further adapted to output information indicative of the location of the radiation source within the environment.

Vilim, Richard B.↗

Subcritical Multiplication with a Fixed Source

In a subcritical, multiplying medium, the system multiplication describes the expected total number of neutrons created by a single source neutron. Subcriticality plays a large role in criticality safety and thus it is vital for the subcritical multiplication factor be accurate, especially as a system approaches criticality. This work examines the accuracy of calculating the system multiplication using the MCNP6.2 ® k-eigenvalue power iteration (KCODE) method when a fixed-point source is present in a multiplying medium, for near critical systems. This work compares the standard approach for calculating system multiplication, using the fixed-source calculational approach, to a new, single k-eigenvalue power iteration approach that incorporates a fixed-source component and a fission-source component into a single calculation. For the remainder of this paper, some theoretical background and numerical results for an approximate k eigenvalue approach, an accurate fixed-source approach and a new and more accurate k-eigenvalue approach to computing system multiplication are provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Solar Energetic Particle Event of 2010 August 14: Connectivity with the Solar Source Inferred from Multiple Spacecraft Observations and Modeling

We analyze one of the first solar energetic particle (SEP) events of solar cycle 24 observed at widely separated spacecraft in order to assess the reliability of models currently used to determine the connectivity between the sources of SEPs at the Sun and spacecraft in the inner heliosphere. This SEP event was observed on 2010 August 14 by near-Earth spacecraft, STEREO-A (∼80° west of Earth) and STEREO-B (∼72° east of Earth). In contrast to near-Earth spacecraft, the footpoints of the nominal magnetic field lines connecting STEREO-A and STEREO-B with the Sun were separated from the region where the parent fast halo coronal mass ejection (CME) originated by ∼88° and ∼47° in longitude, respectively. We discuss the properties of the phenomena associated with this solar eruption. Extreme ultraviolet and white-light images are used to specify the extent of the associated CME-driven coronal shock. We then assess whether the SEPs observed at the three heliospheric locations were accelerated by this shock or whether transport mechanisms in the corona and/or interplanetary space provide an alternative explanation for the arrival of particles at the poorly connected spacecraft. A possible scenario consistent with the observations indicates that the observation of SEPs at STEREO-B and near Earth resulted from particle injection by the CME shock onto the field lines connecting to these spacecraft, whereas SEPs reached STEREO-A mostly via cross-field diffusive transport processes. The successes, limitations, and uncertainties of the methods used to resolve the connection between the acceleration sites of SEPs and the spacecraft are evaluated.

79 ASTRONOMY AND ASTROPHYSICS↗