Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mismatch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

SU-E-T-294: Simulations to Investigate the Feasibility of ‘dry’ Optical-CT Imaging for 3D Dosimetry

Purpose: To perform simulations investigating the feasibility of “dry” optical-CT, and determine optimal design and scanning parameters for a novel dry tank telecentric optical-CT 3D dosimetry system. Such a system would have important advantages in terms of practical convenience and reduced cost. Methods: A Matlab based ray-tracing simulation platform, ScanSim, was used to model a telecentric system with a polyurethane dry tank, cylindrical dosimeter, and surrounding fluid. This program's capabilities were expanded for the geometry and physics of dry scanning. To categorize the effects of refractive index (RI) mismatches, simulations were run for several dosimeter (RI = 1.5−1.48) and fluid (RI = 1.55−1.33) combinations. Additional simulations examined the effect of increasing gap size (1–5mm) between the dosimeter and tank wall, and of changing the telecentric lens tolerance (0.5°−5°). The evaluation metric is the usable radius; the distance from the dosimeter center where the measured and true doses differ by less than 2%. Results: As the tank/dosimeter RI mismatch increases from 0–0.02, the usable radius decreases from 97.6% to 50.2%. The fluid RI for matching is lower than either the tank or dosimeter RI. Changing gap sizes has drastic effects on the usable radius, requiring more closely matched fluid at large gap sizes. Increasing the telecentric tolerance through a range from 0.5°–5.0° improved the usable radius for every combination of media. Conclusion: Dry optical-CT with telecentric lenses is feasible when the dosimeter and tank RIs are closely matched (<0.01 difference), or when data in the periphery is not required. The ScanSim tool proved very useful in situations when the tank and dosimeter have slight differences in RI by enabling estimation of the optimal choice of RI of the small amount of fluid still required. Some spoiling of the telecentric beam and increasing the tolerance helps recover the usable radius.

07 ISOTOPE AND RADIATION SOURCES↗

WE-G-18A-05: Cone-Beam CT Reconstruction with Deformed Prior Image

Purpose: Prior image can be incorporated into image reconstruction process to improve the quality of on-treatment cone-beam CT (CBCT) from sparseview or low-dose projections. However, the deformation between the prior image and on-treatment CBCT are not considered in current prior image based reconstructions (e.g., prior image constrained compressed sensing (PICCS)). The purpose of this work is to develop a deformed-prior-imagebased- reconstruction strategy (DPIR) to address the mismatch problem between the prior image and target image. Methods: The deformed prior image is obtained by a projection based registration approach. Specifically, the deformation vector fields (DVF) used to deform the prior image is estimated through matching the forward projection of the prior image and the measured on-treatment projection. The deformed prior image is then used as the prior image in the standard PICCS algorithm. Simulation studies on the XCAT phantom was conducted to evaluate the performance of the projection based registration procedure and the proposed DPIR strategy. Results: The deformed prior image matches the geometry of on-treatment CBCT closer as compared to the original prior image. Using the deformed prior image, the quality of the image reconstructed by DPIR from few-view projection data is greatly improved as compared to the standard PICCS algorithm. The relative image reconstruction error is reduced to 11.13% in the proposed DPIR from 17.57% in the original PICCS. Conclusion: The proposed DPIR approach can solve the mismatch problem between the prior image and target image, which overcomes the limitation of the original PICCS algorithm for CBCT reconstruction from sparse-view or low-dose projections.

60 APPLIED LIFE SCIENCES↗

Impact of extraneous mispositioned events on motion-corrected brain SPECT images of freely moving animals

Purpose: Single photon emission computed tomography (SPECT) brain imaging of freely moving small animals would allow a wide range of important neurological processes and behaviors to be studied, which are normally inhibited by anesthetic drugs or precluded due to the animal being restrained. While rigid body motion of the head can be tracked and accounted for in the reconstruction, activity in the torso may confound brain measurements, especially since motion of the torso is more complex (i.e., nonrigid) and not well correlated with that of the head. The authors investigated the impact of mispositioned events and attenuation due to the torso on the accuracy of motion corrected brain images of freely moving mice. Methods: Monte Carlo simulations of a realistic voxelized mouse phantom and a dual compartment phantom were performed. Each phantom comprised a target and an extraneous compartment which were able to move independently of each other. Motion correction was performed based on the known motion of the target compartment only. Two SPECT camera geometries were investigated: a rotating single head detector and a stationary full ring detector. The effects of motion, detector geometry, and energy of the emitted photons (hence, attenuation) on bias and noise in reconstructed brain regions were evaluated. Results: The authors observed two main sources of bias: (a) motion-related inconsistencies in the projection data and (b) the mismatch between attenuation and emission. Both effects are caused by the assumption that the orientation of the torso is difficult to track and model, and therefore cannot be conveniently corrected for. The motion induced bias in some regions was up to 12% when no attenuation effects were considered, while it reached 40% when also combined with attenuation related inconsistencies. The detector geometry (i.e., rotating vs full ring) has a big impact on the accuracy of the reconstructed images, with the full ring detector being more advantageous. Conclusions: Motion-induced inconsistencies in the projection data and attenuation/emission mismatch are the two main causes of bias in reconstructed brain images when there is complex motion. It appears that these two factors have a synergistic effect on the qualitative and quantitative accuracy of the reconstructed images.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 08: Rotational errors with on-board cone beam computed tomography

The focus of this study is on the Elekta XVI on-board cone beam computed tomography (CBCT) system. A rotational mismatch as large as 0.5° is observed between clockwise (CW) and counter-clockwise (CCW) CBCT scans. The error could affect non-isocentric treatments (e.g., lung SBRT and acoustic neuroma), as well as off-axis organs-at-risk. The error is caused by mislabeling of the projections with a lagging gantry angle, which is caused by the finite image acquisition time and delays in the imaging system. A 30 cm diameter cylindrical phantom with 5 mm diameter holes is used for the scanning. CW and CCW scans are acquired for five gantry speeds (360 to 120 deg./min.) on six linacs from three generations (MLCi, MLCi2, and Agility). Additional scans are acquired with different x-ray pulse widths for the same mAs. In the automated CBCT analysis (using ImageJ), the CW/CCW mismatch in a series of line profiles is identified and used to calculate the rotational error. Results are consistent among all linacs and indicate that the error varies linearly with gantry speed. The finite width of the x-ray pulses is a major but predictable contributor to the delay causing the error. For 40 ms pulses, the delay is 34 ± 1 ms. A simple solution applied in our clinic is adjusting the gantry angle offset to make the CCW one-minute scans correct. A more involved approach we are currently investigating includes adjustments of pulse width and mA, resulting in focal spot changes, with potential impact on image quality.

60 APPLIED LIFE SCIENCES↗

SU-E-P-13: Quantifying the Geometric Error Due to Irregular Motion in Four-Dimensional Computed Tomography (4DCT)

Purpose: Respiratory correlated 4DCT images are generated under the assumption of a regular breathing cycle. This study evaluates the error in 4DCT-based target position estimation in the presence of irregular respiratory motion. Methods: A custom-made programmable externally-and internally-deformable lung motion phantom was placed inside the CT bore. An abdominal pressure belt was placed around the phantom to mimic clinical 4DCT acquisitio and the motion platform was programmed with a sinusoidal (±10mm, 10 cycles per minute) motion trace and 7 motion traces recorded from lung cancer patients. The same setup and motion trajectories were repeated in the linac room and kV fluoroscopic images were acquired using the on-board imager. Positions of 4 internal markers segmented from the 4DCT volumes were overlaid upon the motion trajectories derived from the fluoroscopic time series to calculate the difference between estimated (4DCT) and “actual” (kV fluoro) positions. Results: With a sinusoidal trace, absolute errors of the 4DCT estimated markers positions vary between 0.78mm and 5.4mm and RMS errors are between 0.38mm to 1.7mm. With irregular patient traces, absolute errors of the 4DCT estimated markers positions increased significantly by 100 to 200 percent, while the corresponding RMS error values have much smaller changes. Significant mismatches were frequently found at peak-inhale or peak-exhale phase. Conclusion: As expected, under conditions of well-behaved, periodic sinusoidal motion, the 4DCT yielded much better estimation of marker positions. When an actual patient trace is used 4DCT-derived positions showed significant mismatches with the fluoroscopic trajectories, indicating the potential for geometric and therefore dosimetric errors in the presence of cycle-to-cycle respiratory variations.

60 APPLIED LIFE SCIENCES↗

SU-E-T-586: Optimal Determination of Tolerance Level for Radiation Dose Delivery Verification in An in Vivo Dosimetry System

Purpose: To statistically determine the optimal tolerance level in the verification of delivery dose compared to the planned dose in an in vivo dosimetry system in radiotherapy. Methods: The LANDAUER MicroSTARii dosimetry system with screened nanoDots (optically stimulated luminescence dosimeters) was used for in vivo dose measurements. Ideally, the measured dose should match with the planned dose and falls within a normal distribution. Any deviation from the normal distribution may be redeemed as a mismatch, therefore a potential sign of the dose misadministration. Randomly mis-positioned nanoDots can yield a continuum background distribution. A percentage difference of the measured dose to its corresponding planned dose (ΔD) can be used to analyze combined data sets for different patients. A model of a Gaussian plus a flat function was used to fit the ΔD distribution. Results: Total 434 nanoDot measurements for breast cancer patients were collected across a period of three months. The fit yields a Gaussian mean of 2.9% and a standard deviation (SD) of 5.3%. The observed shift of the mean from zero is attributed to the machine output bias and calibration of the dosimetry system. A pass interval of −2SD to +2SD was applied and a mismatch background was estimated to be 4.8%. With such a tolerance level, one can expect that 99.99% of patients should pass the verification and at most 0.011% might have a potential dose misadministration that may not be detected after 3 times of repeated measurements. After implementation, a number of new start breast cancer patients were monitored and the measured pass rate is consistent with the model prediction. Conclusion: It is feasible to implement an optimal tolerance level in order to maintain a low limit of potential dose misadministration while still to keep a relatively high pass rate in radiotherapy delivery verification.

61 RADIATION PROTECTION AND DOSIMETRY↗

4D ML reconstruction as a tool for volumetric PET-based treatment verification in ion beam radiotherapy

Purpose: An innovative strategy to improve the sensitivity of positron emission tomography (PET)-based treatment verification in ion beam radiotherapy is proposed. Methods: Low counting statistics PET images acquired during or shortly after the treatment (Measured PET) and a Monte Carlo estimate of the same PET images derived from the treatment plan (Expected PET) are considered as two frames of a 4D dataset. A 4D maximum likelihood reconstruction strategy was adapted to iteratively estimate the annihilation events distribution in a reference frame and the deformation motion fields that map it in the Expected PET and Measured PET frames. The outputs generated by the proposed strategy are as follows: (1) an estimate of the Measured PET with an image quality comparable to the Expected PET and (2) an estimate of the motion field mapping Expected PET to Measured PET. The details of the algorithm are presented and the strategy is preliminarily tested on analytically simulated datasets. Results: The algorithm demonstrates (1) robustness against noise, even in the worst conditions where 1.5 × 10{sup 4} true coincidences and a random fraction of 73% are simulated; (2) a proper sensitivity to different kind and grade of mismatches ranging between 1 and 10 mm; (3) robustness against bias due to incorrect washout modeling in the Monte Carlo simulation up to 1/3 of the original signal amplitude; and (4) an ability to describe the mismatch even in presence of complex annihilation distributions such as those induced by two perpendicular superimposed ion fields. Conclusions: The promising results obtained in this work suggest the applicability of the method as a quantification tool for PET-based treatment verification in ion beam radiotherapy. An extensive assessment of the proposed strategy on real treatment verification data is planned.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-AB-BRA-09: Registration of Preoperative MRI to Intraoperative Radiographs for Automatic Vertebral Target Localization

Purpose: Accurate localization of target vertebrae is essential to safe, effective spine surgery, but wrong-level surgery occurs with surprisingly high frequency. Recent research yielded the “LevelCheck” method for 3D-2D registration of preoperative CT to intraoperative radiographs, providing decision support for level localization. We report a new method (MR-LevelCheck) to perform 3D-2D registration based on preoperative MRI, presenting a solution for the increasingly common scenario in which MRI (not CT) is used for preoperative planning. Methods: Direct extension of LevelCheck is confounded by large mismatch in image intensity between MRI and radiographs. The proposed method overcomes such challenges with a simple vertebrae segmentation. Using seed points at centroids, vertebrae are segmented using continuous max-flow method and dilated by 1.8 mm to include surrounding cortical bone (inconspicuous in T2w-MRI). MRI projections are computed (analogous to DRR) using segmentation and registered to intraoperative radiographs. The method was tested in a retrospective IRB-approved study involving 11 patients undergoing cervical, thoracic, or lumbar spine surgery following preoperative MRI. Registration accuracy was evaluated in terms of projection-distance-error (PDE) between the true and estimated location of vertebrae in each radiograph. Results: The method successfully registered each preoperative MRI to intraoperative radiographs and maintained desirable properties of robustness against image content mismatch, and large capture range. Segmentation achieved Dice coefficient = 89.2 ± 2.3 and mean-absolute-distance (MAD) = 1.5 ± 0.3 mm. Registration demonstrated robust performance under realistic patient variations, with PDE = 4.0 ± 1.9 mm (median ± iqr) and converged with run-time = 23.3 ± 1.7 s. Conclusion: The MR-LevelCheck algorithm provides an important extension to a previously validated decision support tool in spine surgery by extending its utility to preoperative MRI. With initial studies demonstrating PDE <5 mm and 0% failure rate, the method is now in translation to larger scale prospective clinical studies. S. Vogt and G. Kleinszig are employees of Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

Dislocation-driven growth of two-dimensional lateral quantum-well superlattices

Here, the advent of two-dimensional (2D) materials has led to extensive studies of heterostructures for novel applications. 2D lateral multiheterojunctions and superlattices have been recently demonstrated, but the available growth methods can only produce features with widths in the micrometer or, at best, 100-nm scale and usually result in rough and defective interfaces with extensive chemical intermixing. Widths smaller than 5 nm, which are needed for quantum confinement effects and quantum-well applications, have not been achieved. We demonstrate the growth of sub–2-nm quantum-well arrays in semiconductor monolayers, driven by the climb of misfit dislocations in a lattice-mismatched sulfide/selenide heterointerface. Density functional theory calculations provide an atom-by-atom description of the growth mechanism. The calculated energy bands reveal type II alignment suitable for quantum wells, suggesting that the structure could, in principle, be turned into a “conduit” of conductive nanoribbons for interconnects in future 2D integrated circuits via n-type modulation doping. This misfit dislocation–driven growth can be applied to different combinations of 2D monolayers with lattice mismatch, paving the way to a wide range of 2D quantum-well superlattices with controllable band alignment and nanoscale width.

36 MATERIALS SCIENCE↗

Evolution of exciton states near the percolation threshold in two-phase systems with II-VI semiconductor quantum dots

From studies of two-phase systems (borosilicate matrices containing ZnSe or CdS quantum dots), it was found that the systems exhibit a specific feature associated with the percolation phase transition of charge carriers (excitons). The transition manifests itself as radical changes in the optical spectra of both ZnSe and CdS quantum dot systems and by fluctuations of the emission band intensities near the percolation threshold. These effects are due to microscopic fluctuations of the density of quantum dots. The average spacing between quantum dots is calculated taking into account their finite dimensions and the volume fraction occupied by the quantum dots at the percolation threshold. It is shown that clustering of quantum dots occurs via tunneling of charge carriers between the dots. A physical mechanism responsible for the percolation threshold for charge carriers is suggested. In the mechanism, the permittivity mismatch of the materials of the matrix and quantum dots plays an important role in delocalization of charge carriers (excitons): due to the mismatch, 'a dielectric trap' is formed at the external surface of the interface between the matrix and a quantum dot and, thus, surface exciton states are formed there. The critical concentrations of quantum dots are determined, such that the spatial overlapping of such surface states provides the percolation transition in both systems.

36 MATERIALS SCIENCE↗

Features of molecular-beam epitaxy and structural properties of AlInSb-based heterostructures

AlInSb layers are grown on highly lattice-mismatched GaAs (100) substrates by molecular-beam epitaxy (MBE) and studied in situ by reflection high-energy electron diffraction and ex situ by scanning and transmission electron microscopy (SEM and TEM). It is shown that one feature of AlInSb/GaAs heterostructure features is a high probability of forming microtwins; methods for decreasing their concentration are proposed. To initiate AlInSb growth on GaAs substrates under high lattice-mismatch ({approx}14.5%) conditions and to stimulate the transition to 2D growth, the GaAs layer surface was preliminarily exposed to an antimony flux followed by deposition of an intermediate AlSb buffer layer. The optimization of initial MBE growth stages of Sb-containing layers on the GaAs surface allows a decrease in the defect density in the GaAs/AlInSb heterostructures more than by two orders of magnitude, including a drastic decrease in the microtwin density. Optimal MBE growth conditions for Al{sub x}Al{sub 1-x}Sb are determined in a wide composition range (0 < x < 0.3). The TEM and SEM studies confirm the high structural quality of grown GaAs/AlInSb heterostructures. Hall-effect measurements showed the dependence of the carrier mobility and concentration on the aluminum content in AlInSb layers and allowed preliminary conclusions on scattering mechanisms.

36 MATERIALS SCIENCE↗

Optical properties of InGaAs/InGaAlAs quantum wells for the 1520–1580 nm spectral range

The optical properties of elastically strained semiconductor heterostructures with InGaAs/InGaAlAs quantum wells (QWs), intended for use in the formation of the active region of lasers emitting in the spectral range 1520–1580 nm, are studied. Active regions with varied lattice mismatch between the InGaAs QWs and the InP substrate are fabricated by molecular beam epitaxy. The maximum lattice mismatch for the InGaAs QWs is +2%. The optical properties of the elastically strained InGaAlAs/InGaAs/InP heterostructures are studied by the photoluminescence method in the temperature range from 20 to 140°C at various power densities of the excitation laser. Investigation of the optical properties of InGaAlAs/InGaAs/InP experimental samples confirms the feasibility of using the developed elastically strained heterostructures for the fabrication of active regions for laser diodes with high temperature stability.

36 MATERIALS SCIENCE↗

Investigation of Composition Uniformity in Thickness of GaInAsP Layers Grown on InP Substrates by Vapor-Phase Epitaxy

GaInPAs/InP heterostructures grown by metalorganic chemical vapor-phase deposition at a temperature of 600°C and pressure of 0.1 bar are investigated. The thicknesses of the grown GaInAsP layers amount to about 1 μm. For Ga{sub 1 –x}In{sub x}P{sub 1 –y}As{sub y} solid solutions with average compositions of x = 0.77–0.87 and y = 0.07–0.42, the variation in the content y of V-group atoms over the epitaxial-layer thickness by a value of Δy up to 0.1 atomic fractions in the sublattice of the V-group elements is revealed by secondary ion mass spectrometry. In most cases, a change in y occurs in the GaInAsP layer over a length to 200 nm from the InP heterointerface. In certain cases, y varies throughout the entire GaInPAs-layer thickness. For the epitaxial layers with satisfactory crystalline perfection, the value of Δy is less in the case of better lattice-matching between the GaInPAs epitaxial layer and the substrate. For GaInPAs layers strongly lattice-mismatched with the substrate and characterized by a low degree of crystalline perfection, the value of Δy is close to zero. All these facts enable us to assume that it is elastic deformations arising in the forming monolayer lattice-mismatched with the growing surface that affect the incorporation of V-group atoms into the forming crystalline lattice.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Epitaxial Electrodeposition of Wide Bandgap Cuprous Bromide on Silver via a Silver Bromide Buffer Layer

Cuprous halides are an important class of wide bandgap p-type semiconductors used in opto-electronics. Cuprous bromide (CuBr) shows potential for short-wavelength devices due to a large exciton binding energy (108 meV) and near-ultraviolet bandgap (3.1 eV). However, the growth of high-quality epitaxial CuBr films by electrodeposition has remained a challenge. Here, we introduce a low-cost electrochemical procedure for producing epitaxial CuBr(111) on a Ag(111) substrate by a [111]-oriented silver bromide (AgBr) buffer layer. The AgBr buffer layer forms during the electrodeposition of the CuBr. The mismatch between CuBr(111) and AgBr(111) is –1.3%. A plausible mechanism for nucleation and growth of the epitaxial CuBr is proposed. X-ray techniques including high resolution X-ray diffraction and X-ray pole figures are used to determine the epitaxial relationship. CuBr(100) is also produced on a Ag(100) surface by a AgBr(100) buffer layer that is rotated in-plane 45° relative to the Ag(100) surface. In conclusion, this in-plane rotation reduces the lattice mismatch from +39.5% for an unrotated film to –1.4% for a 45° rotated film.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MOSAIC-CONUS: A Multimodal, Multi-Temporally Paired Dataset for Earth Sciences

Earth embeddings—vector representations of geographic locations indexed in space and time—are emerging as a unifying interface for geospatial AI. However, their quality depends not only on model design, but on how multimodal Earth observation (EO) data are spatially indexed, temporally aligned, and cross-modally associated during pretraining. We introduce MOSAIC-CONUS (Multimodal Observations with Spatially Aligned Imagery, Urban Points of Interest, In-Situ Measurements and Text Captions), a large-scale EO dataset over the contiguous United States, organized around 250,000 stratified point indices that serve as stable spatial keys across seven modalities: active radar, passive optical imagery, lidar-derived elevation, land cover, functional context, hydrometeorological measurements, and textual summaries. Unlike existing EO datasets, MOSAIC-CONUS introduces four contributions not jointly addressed in prior work: 1. an open-source, large-scale multimodal EO corpus structured around point-indexed data designed to support Earth embedding learning; 2. explicit radar-optical pairing tables spanning twelve temporal alignment regimes, formalizing cross-sensor alignment as a controllable variable for analyzing how temporal mismatch across modalities influences learned embeddings quality; 3. a benchmark suite spanning cross-modal retrieval, annual nightlights regression, and basin-held-out streamflow prediction, positioning MOSAIC-CONUS as a benchmark-ready resource for multimodal AI systems; and 4. a language-based embedding layer through co-registered textual summaries, enabling Earth embeddings to function as a queryable interface for agentic AI systems. The dataset and pairing protocols are publicly released.

54 ENVIRONMENTAL SCIENCES↗

Smoothing tool design and performance during subaperture glass polishing

During subaperture tool grinding and polishing, overlaps of the tool influence function can result in undesirable mid-spatial frequency (MSF) errors in the form of surface ripples, which are often corrected using a smoothing polishing step. Here, in this study, flat multi-layer smoothing polishing tools are designed and tested to simultaneously (1) reduce or remove MSF errors, (2) minimize surface figure degradation, and (3) maximize the material removal rate. A time-dependent convergence model in which spatial material removal varies with a workpiece-tool height mismatch, combined with a finite element mechanical analysis to determine the interface contact pressure distribution, was developed to evaluate various smoothing tool designs as a function of tool material properties, thicknesses, pad textures, and displacements. An improvement in smoothing tool performance is achieved when the gap pressure constant, $\overline{h}$ (which describes the inverse rate at which the pressure drops with a workpiece-tool height mismatch), is minimized for smaller spatial scale length surface features (namely, MSF errors) and maximized for large spatial scale length features (i.e., surface figure). Five specific smoothing tool designs were experimentally evaluated. A two-layer smoothing tool using a thin, grooved IC1000 polyurethane pad (with a high elastic modulus, E pad =360 MPa ), thicker blue foam (with an intermediate modulus, E foam =5.3 MPa ) underlayer, and an optimized displacement (d t =1 mm ) provided the best overall performance (namely, high MSF error convergence, minimal surface figure degradation, and high material removal rate).

47 OTHER INSTRUMENTATION↗

Impact of longitudinal phase-matching variations on three-wave nonlinear interactions

A general study of three-wave nonlinear mixing in the presence of longitudinal variations in phase-matching conditions is presented. The efficiency of second-harmonic generation and optical parametric amplification is quantified using a normalized set of equations and a polynomial description of the wave-vector mismatch as a function of the longitudinal coordinate. These modeling results are used to estimate the impact of spatial variations in wave-vector mismatch experimentally obtained for five partially deuterated potassium dihydrogen phosphate crystals. The longitudinal inhomogeneities in the properties of crystals of similar quality are not expected to have a significant impact on their use for second-harmonic generation and optical parametric amplification, but the efficiency of nonlinear processes in crystals with larger variations could decrease.

36 MATERIALS SCIENCE↗

3D X-ray Microprobe Investigation of Local Dislocation Densities and Elastic Strain Gradients in a NiAl-Mo Composite and Exposed Mo Micropillars as a Function of Pre-strain

3D spatially-resolved polychromatic microdiffraction was used to nondestructively probe the depth-dependent dislocation density and elastic strain gradients in separate phases of a NiAl Mo composite. Dislocation density and strain gradients are investigated before and after compressive strain. After plastic deformation important changes in the local stress state are found compared to the as grown composite. In as grown composites, due to the thermal expansion mismatch, the Mo phase is under compression and the NiAl phase is in tension. After compressive strain, the Mo phase is in tension and NiAl matrix is under compression. This result can be understood from the mismatch in yield strain of the composite material and from the elastic constraints during unloading. The dislocation density in both phases is found to grow with increased straining. These measurements provide quantitative dislocation information to guide recent directional solidified Mo micro-pillar testing. They also guide models of interface dynamics in composite materials.

36 MATERIALS SCIENCE↗