Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

The natural thermoluminescence of meteorites. III - Lunar and basaltic meteorites

Natural thermoluminescence (TL) data were obtained to investigate recent thermal and radiation histories of the lunar meteorite MacAlpine Hills 88104/5 and 65 eucrites, howardites, diogenites, and mesosiderites. All these meteorites have low levels of natural TL compared to chondrites, which is primarily because they display anomalous fading. Some meteorites have especially low natural TL which must reflect heating within the last 100,000-1,000,000 y. The parameters for TL decay were determined assuming plausible values for cosmic ray dose rate and that the natural TL of MAC88104/5 was totally drained by ejection from the moon. The obtained parameters for TL decay suggest that the moon-earth transit times for MAC88104 and MAC88105 were 2,000 and 1,800 y, respectively, compared with 19,000 and 2,500 y for Y791197 and ALHA81005, respectively.

Sears, Derek W. G.↗

Steady and transient fluid shear stress stimulate NO release in osteoblasts through distinct biochemical pathways

Fluid flow has been shown to be a potent stimulus in osteoblasts and osteocytes and may therefore play an important role in load-induced bone remodeling. The objective of this study was to investigate the characteristics of flow-activated pathways. Previously we reported that fluid flow stimulates rapid and continuous release of nitric oxide (NO) in primary rat calvarial osteoblasts. Here we demonstrate that flow-induced NO release is mediated by shear stress and that this response is distinctly biphasic. Transients in shear stress associated with the onset of flow stimulated a burst in NO production (8.2 nmol/mg of protein/h), while steady flow stimulated sustained NO production (2.2 nmol/mg of protein/h). Both G-protein inhibition and calcium chelation abolished the burst phase but had no effect on sustained production. Activation of G-proteins stimulated dose-dependent NO release in static cultures of both calvarial osteoblasts and UMR-106 osteoblast-like cells. Pertussis toxin had no effect on NO release. Calcium ionophore stimulated low levels of NO production within 15 minutes but had no effect on sustained production. Taken together, these data suggest that fluid shear stress stimulates NO release by two distinct pathways: a G-protein and calcium-dependent phase sensitive to flow transients, and a G-protein and calcium-independent pathway stimulated by sustained flow.

Non-NASA Center↗

Neurogenic orthostatic hypotension: a double-blind, placebo-controlled study with midodrine

PURPOSE: To investigate the efficacy and safety of midodrine for treatment of patients with orthostatic hypotension due to autonomic failure. PATIENTS: Ninety-seven patients with orthostatic hypotension were randomized in a 4-week, double-blinded, placebo-controlled study with a 1-week placebo run-in period. Patients ranged in age from 22 to 86 years (mean: 61 years). METHODS: After a 1-week run-in phase, either placebo or midodrine at a dose of 2.5 mg, 5 mg, or 10 mg was administered three times a day for 4 weeks. Both the placebo group and the 2.5-mg midodrine group received constant doses throughout the double-blind phase. The patients receiving 5 mg or 10 mg of midodrine were given doses that were increased at weekly intervals by 2.5-mg increments until the designated dose was reached. Efficacy evaluations were based on an improvement at 1-hour postdose in standing systolic blood pressure and in symptoms of orthostatic hypotension (syncope, dizziness/lightheadedness, weakness/fatigue, and low energy level). RESULTS: Midodrine (10 mg) increased standing systolic blood pressure by 22 mm Hg (28%, p < 0.001 versus placebo). Midodrine improved (p < 0.05) the following symptoms of orthostatic hypotension compared to placebo: dizziness/lightheadedness, weakness/fatigue, syncope, low energy level, impaired ability to stand, and feelings of depression. The overall side effects were mainly mild to moderate. One or more side effects were reported by 22% of the placebo group compared with 27% of the midodrine-treated group. Scalp pruritus/tingling, which was reported by 10 of 74 (13.5%) of the midodrine-treated patients, was most frequent. Other reported side effects included supine hypertension (8%) and feelings of urinary urgency (4%). CONCLUSION: We conclude that midodrine is an effective and well-tolerated treatment for moderate-to-severe orthostatic hypotension associated with autonomic failure.

NASA Discipline Number 14-10↗

Computer subroutines for estimation of human exposure to radiation in low Earth orbit

Computer subroutines to calculate human exposure to trapped radiations in low Earth orbit (LEO) on the basis of a simple approximation of the human geometry by spherical shell shields of varying thickness are presented and detailed. The subroutines calculate the dose to critical body organs and the fraction of exposure limit reached as a function of altitude of orbit, degree of inclination, shield thickness, and days in mission. Exposure rates are compared with current exposure limits.

Cucinotta, F. A.↗

Oxidation of silicon with a 5 eV O(-) beam

A silicon wafer has been oxidized at room temperature in vacuum using a pure, ground-state beam of O(-) ions. The beam was of sufficiently low energy that no displacement damage or implantation was energetically possible. The resulting SiO2 films were analyzed with X-ray photoelectron spectroscopy. A logarithmic dependence of oxide thickness on dose was observed, with an extrapolated oxidation efficiency of unity for the clean silicon surface. A distinct initial oxidation phase was observed, with an anomalously high level of silicon suboxides. In addition, the valence-band offset between the silicon and the oxide was unusually small, suggesting a large interfacial dipole.

Hecht, M. H.↗

Induction and repair of HZE induced cytogenetic damage

Wistar rats were exposed to high-mass, high energy (HZE) 56Fe particles (1000 GeV/AMU) using the Alternating Gradient Synchrotron (AGS). The animals were sacrificed at 1-5 hours or after a 30-day recovery period. The frequency of micronuclei in the tracheal and the deep lung epithelial cells were evaluated. The relative effectiveness of 56Fe, for the induction of initial chromosome damage in the form of micronuclei, was compared to damage produced in the same biological system exposed to other types of high and low-LET radiation. It was demonstrated that for animals sacrificed at short times after exposure, the tracheal and lung epithelial cells, the 56Fe particles were 3.3 and 1.3 times as effective as 60Co in production of micronuclei, respectively. The effectiveness was also compared to that for exposure to inhaled radon. With this comparison, the 56Fe exposure of the tracheal epithelial cells and the lung epithelial cells were only 0.18 and 0.20 times as effective as radon in the production of the initial cytogenetic damage. It was suggested that the low relative effectiveness was related to potential for 'wasted energy' from the core of the 56Fe particles. When the animals were sacrificed after 30 days, the slopes of the dose-response relationships, which reflect the remaining level of damage, decreased by a factor of 10 for both the tracheal and lung epithelial cells. In both cases, the slope of the dose-response lines were no longer significantly different from zero, and the r2 values were very high. Lung epithelial cells, isolated from the animals sacrificed hours after exposure, were maintained in culture, and the micronuclei frequency evaluated after 4 and 6 subcultures. These cells were harvested at 24 and 36 days after the exposure. There was no dose-response detected in these cultures and no signs of genomic instability at either sample time.

Non-NASA Center↗

Actively Controlled Louver for Human Spacecraft Radiator Ultraviolet (UV), Dust, and Freeze Protection

The paper examines the use of actively controlled louvers for human spacecraft radiators. State of the Art (SOA) radiators were design for Low Earth Orbit (LEO) operations where Ultraviolet (UV) radiation and dust have miniscule performance impacts. However, Artemis missions to the lunar orbit or surface will expose the radiators to high dose UV radiation and dust, which can degrade the radiator coating emissivity by up to 50% and consequently reduce performance early in missions. In addition, environmental nighttime temperatures at the lunar south pole are significantly colder and linger longer than LEO, and may require up to 4 kW of heater power to prevent coolant tubes from freezing, thawing, and rupturing. Analysis showed equipping the radiators with actively controlled louvers attenuated the UV radiation and dust effects, and limited degradation to less than 10% through End of Life (EOL) of missions. Furthermore, analysis demonstrated the ability to eliminate the heater power needed for freeze protection. Louver technology is a promising solution to maintain radiator performance and integrity for Artemis missions, but heritage louvers are passively controlled and only been used on small satellites. The technology requires maturing to active control, or motor actuated, to achieve faster thermal response times. Design considerations are discussed in this paper.

Louver↗

DNA Break Clustering as a Predictor of Cell Death across Various Radiation Qualities: Influence of Cell Size, Cell Asymmetry, and Beam Orientation

Cosmic radiation, composed of high charge and energy (HZE) particles, causes cellular DNA damage that can result in cell death or mutation that can evolve into cancer. In this work, a cell death model is applied to several cell lines exposed to HZE ions spanning a broad range of linear energy transfer (LET) values. We hypothesize that chromatin movement leads to the clustering of multiple double strand breaks (DSB) within one radiation-induced foci (RIF). The survival probability of a cell population is determined by averaging the survival probabilities of individual cells, which is function of the number of pairwise DSB interactions within RIF. The simulation code RITCARD was used to compute DSB. Two clustering approaches were applied to determine the number of RIF per cell. RITCARD outputs were combined with experimental data from four normal human cell lines to derive the model parameters and expand its predictions in response to ions with LET ranging from ∼0.2keV/μmto∼3000keV/μm. Spherical and ellipsoidal nuclear shapes and two ion beam orientations were modeled to assess the impact of geometrical properties on cell death. The calculated average number of RIF per cell reproduces the saturation trend for high doses and high-LET values that is usually experimentally observed. The cell survival model generates the recognizable bell shape of LET dependence for the relative biological effectiveness (RBE). At low LET, smaller nuclei have lower survival due to increased DNA density and DSB clustering. At high LET, nuclei with a smaller irradiation area either because of a smaller size or a change in beam orientation have a higher survival rate due to a change in the distribution of DSB/RIF per cell. If confirmed experimentally, the geometric characteristics of cells would become a significant factor in predicting radiation-induced biological effects.

cell survival↗

Effects of alpha-particles on survival and chromosomal aberrations in human mammary epithelial cells

We have studied the radiation responses of a human mammary epithelial cell line, H184B5 F5-1 M/10. This cell line was derived from primary mammary cells after treatment with chemicals and heavy ions. The F5-1 M/10 cells are immortal, density-inhibited in growth, and non-tumorigenic in athymic nude mice and represent an in vitro model of the human epithelium for radiation studies. Because epithelial cells are the target of alpha-particles emitted from radon daughters, we concentrated our studies on the efficiency of alpha-particles. Confluent cultures of M/10 cells were exposed to accelerated alpha-particles [beam energy incident at the cell monolayer = 3.85 MeV, incident linear energy transfer (LET) in cell = 109 keV/microns] and, for comparison, to 80 kVp x-rays. The following endpoints were studied: (1) survival, (2) chromosome aberrations at the first postirradiation mitosis, and (3) chromosome alterations at later passages following irradiation. The survival curve was exponential for alpha-particles (D0 = 0.73 +/- 0.04 Gy), while a shoulder was observed for x-rays (alpha/beta = 2.9 Gy; D0 = 2.5 Gy, extrapolation number 1.6). The relative biological effectiveness (RBE) of high-LET alpha-particles for human epithelial cell killing was 3.3 at 37% survival. Dose-response curves for the induction of chromosome aberrations were linear for alpha-particles and linearquadratic for x-rays. The RBE for the induction of chromosome aberrations varied with the type of aberration scored and was high (about 5) for chromosome breaks and low (about 2) for chromosome exchanges.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Center JSC↗

Simulation and Comparison of Martian Surface Ionization Radiation

The spectrum of energetic particle radiation and corresponding doses at the surface of Mars is being characterized by the Radiation Assessment Detector (RAD), one of ten science instruments on the Mars Science Laboratory (MSL) Curiosity Rover. The time series of dose rate for the first 300 Sols after landing on Mars on August 6, 2012 is presented here. For the comparison to RAD measurements of dose rate, Martian surface ionization radiation is simulated by utilizing observed space quantities. The GCR primary radiation spectrum is calculated by using the Badhwar-O'Neill 2011 (BO11) galactic cosmic ray (GCR) model, which has been developed by utilizing all balloon and satellite GCR measurements since 1955 and the newer 1997-2012 Advanced Composition Explorer (ACE) measurements. In the BO11 model, solar modulation of the GCR primary radiation spectrum is described in terms of the international smoothed sunspot number and a time delay function. For the transport of the impingent GCR primary radiation through Mars atmosphere, a vertical distribution of atmospheric thickness at each elevation is calculated using the vertical profiles of atmospheric temperature and pressure made by Mars Global Surveyor measurements. At Gale Crater in the southern hemisphere, the seasonal variation of atmospheric thickness is accounted for the daily atmospheric pressure measurements of the MSL Rover Environmental Monitoring Station (REMS) by using low- and high-density models for cool- and warm-season, respectively. The spherically distributed atmospheric distance is traced along the slant path, and the resultant directional shielding by Martian atmosphere is coupled with Curiosity vehicle for dose estimates. We present predictions of dose rate and comparison to the RAD measurements. The simulation agrees to within +/- 20% with the RAD measurements showing clearly the variation of dose rate by heliospheric conditions, and presenting the sensitivity of dose rate by atmospheric pressure, which has been found from the RAD experiments and driven by thermal tides on Martian surface.

Kim, Myung-Hee Y.↗

Optical Analysis of Transparent Polymeric Material Exposed to Simulated Space Environment

Many innovations in spacecraft power and propulsion have been recently tested at NASA, particularly in non-chemical propulsion. One improvement in solar array technology is solar concentration using thin polymer film Fresnel lenses. Weight and cost savings were proven with the Solar Concentrator Arrays with Refractive Linear Element Technology (SCARLET)-II array on NASA's Deep Space I spacecraft. The Fresnel lens concentrates solar energy onto high-efficiency solar cells, decreasing the area of solar cells needed for power. Continued efficiency of this power system relies on the thin film's durability in the space environment and maintaining transmission in the 300 - 1000 nm bandwidth. Various polymeric materials have been tested for use in solar concentrators, including Lexan(TM), polyethylene terephthalate (PET), several formulations of Tefzel(Tm) and Teflon(TM), and DC 93-500, the material selected for SCARLET-II. Also tested were several innovative materials including Langley Research Center's CPI and CP2 polymers and atomic oxygen- resistant polymers developed by Triton Systems, Inc. The Environmental Effects Group of the Marshall Space Flight Center's Materials, Processes, and Manufacturing Department exposed these materials to simulated space environment and evaluated them for any change in optical transmission. Samples were exposed to a minimum of 1000 equivalent Sun hours of near-UV radiation (250 - 400 nm wavelength). Materials that appeared robust after near-UV exposure were then exposed to charged particle radiation equivalent to a five-year dose in geosynchronous orbit. These exposures were performed in MSFC's Combined Environmental Effects Test Chamber, a unique facility with the capability to expose materials simultaneously or sequentially to protons, low-energy electrons, high-energy electrons, near UV radiation and vacuum UV radiation. Reflectance measurements can be made on the samples in vacuum. Prolonged exposure to the space environment will decrease the polymer film's transmission and thus reduce the conversion efficiency. A method was developed to normalize the transmission loss and thus rank the materials according to their tolerance to space environmental exposure. Spectral results and the material ranking according to transmission loss are presented.

Edwards, David L.↗

Optical Analysis of Transparent Polymeric Material Exposed to Simulated Space Environment

Transparent polymeric materials are being designed and utilized as solar concentrating lenses for spacecraft power and propulsion systems. These polymeric lenses concentrate solar energy onto energy conversion devices such as solar cells and thermal energy systems. The conversion efficiency is directly related to the transmissivity of the polymeric lens. The Environmental Effects Group of the Marshall Space Flight Center's Materials, Processes, and Manufacturing Department exposed a variety of materials to a simulated space environment and evaluated them for an, change in optical transmission. These materials include Lexan(TM), polyethylene terephthalate (PET). several formulations of Tefzel(TM). and Teflon(TM), and silicone DC 93-500. Samples were exposed to a minimum of 1000 Equivalent Sun Hours (ESH) of near-UV radiation (250 - 400 nm wavelength). Data will be presented on materials exposed to charged particle radiation equivalent to a five-year dose in geosynchronous orbit. These exposures were performed in MSFC's Combined Environmental Effects Test Chamber, a unique facility with the capability to expose materials simultaneously or sequentially to protons, low-energy electrons, high-energy electrons, near UV radiation and vacuum UV radiation.Prolonged exposure to the space environment will decrease the polymer film's transmission and thus reduce the conversion efficiency. A method was developed to normalize the transmission loss and thus rank the materials according to their tolerance to space environmental exposure. Spectral results and the material ranking according to transmission loss are presented.

Edwards, David L.↗

Stability Analysis of ISS Medications

It is known that medications degrade over time, and that extreme storage conditions will hasten their degradation. The temperature and humidity conditions of the ISS have been shown to be within the ideal ranges for medication storage, but the effects of other environmental factors, like elevated exposure to radiation, have not yet been evaluated. Current operational procedures ensure that ISS medications are re-stocked before expiration, but this may not be possible on long duration exploration missions. For this reason, medications that have experienced long duration storage on the ISS were returned to JSC for analysis to determine any unusual effects of aging in the low- Earth orbit environment. METHODS Medications were obtained by the JSC Pharmacy from commercial distributors and were re-packaged by JSC pharmacists to conserve up mass and volume. All medication doses were part of the ISS crew medical kit and were transported to the International Space Station (ISS) via NASA's Shuttle Transportation System (Space Shuttle). After 568 days of storage, the medications were removed from the supply chain and returned to Earth on a Dragon (SpaceX) capsule. Upon return to Earth, medications were transferred to temperature and humidity controlled environmental chambers until analysis. Nine medications were chosen on the basis of their availability for study. The medications included several of the most heavily used by US crewmembers: 2 sleep aids, 2 antihistamines/decongestants, 3 pain relievers, an antidiarrheal and an alertness medication. Each medication was available at a single time point; analysis of the same medication at multiple time points was not possible. Because the samples examined in this study were obtained opportunistically from medical supplies, there were no control samples available (i.e. samples aged for a similar period of time on the ground); a significant limitation of this study. Medications were analyzed using the HPLC/MS methods described in the United States Pharmacopeia (USP) to measure the amount of intact active ingredient, identify degradation products and measure their amounts. Some analyses were conducted by an independent analytical laboratory, but certain (Schedule) medications could not be shipped to their facility and were analyzed at JSC. RESULTS Nine medications were analyzed with respect to active pharmaceutical ingredient (API) and degradant amounts. Results were compared to the USP requirements for API and degradants/impurities content for every FDA-approved medication. One medication met USP requirements at 5 months after its expiration date. Four of the nine (44% of those tested) medications tested met USP requirements up to 8 months post-expiration. Another 3 medications (33% of those tested) met USP guidelines 2-3 months before expiration. One medication, a compound classed by the FDA as a dietary supplement and sometimes used as a sleep aid, failed to meet USP requirements at 11 months post-expiration. CONCLUSION Analysis of each medication at a single time point provides limited information on the stability of a medication stored in particular conditions; it is not possible to predict how long a medication may be safe and effective from these data. Notwithstanding, five of the nine medications tested (56%) met USP requirements for API and degradants/impurities at least 5 months past expiration dates. The single compound that failed to meet USP requirements is not regulated as strictly as prescription medications are during manufacture; it is unknown if this medication would have met the requirements prior to flight. Notably, it was the furthest beyond its expiration date. Only more comprehensive analysis of flight-aged samples compared to appropriate ground controls will permit determination of spaceflight effects on medication stability.

Wotring, V. E.↗

Radiation and Fault Tolerance for Neuromorphic Computing

• The solar wind emanating from the sun is a stream of energetic electrons and protons and ions that are the primary ionizing radiation contributions. • The Earth’s magnetosphere significantly reduces radiation exposure and mutes the effects of solar flares out to 65K Km orbital altitude. • The radiation environment is highly dependent upon mission profile: for example geosynchronous orbits can see 50 times the radiation dose of a polar orbit due to reduction of atmospheric/magnetospheric shielding. • In LEO, the magnetosphere shields the Earth by creating trapped Van Allen radiation belts consisting of electrons and protons, which create a challenging radiation environment confined to specific regions. • Even for LEO, radiation dose can vary by a factor of 30 or more from a quiet sun to a solar flare. • Galactic Cosmic Rays (GCRs) are also present at very high energy, but at low rates. • Radiation effects on semiconductors are highly dependent upon particles species, energy and flux. • Therefore, radiation tolerance requirements will vary with mission profile and duration.

Space Radiation↗

Effects of cosmic rays on single event upsets

Assistance was provided to the Brookhaven Single Event Upset (SEU) Test Facility. Computer codes were developed for fragmentation and secondary radiation affecting Very Large Scale Integration (VLSI) in space. A computer controlled CV (HP4192) test was developed for Terman analysis. Also developed were high speed parametric tests which are independent of operator judgment and a charge pumping technique for measurement of D(sub it) (E). The X-ray secondary effects, and parametric degradation as a function of dose rate were simulated. The SPICE simulation of static RAMs with various resistor filters was tested.

Venable, D. D.↗

Calculation of the Frequency Distribution of the Energy Deposition in DNA Volumes by Heavy Ions

Radiation quality effects are largely determined by energy deposition in small volumes of characteristic sizes less than 10 nm representative of short-segments of DNA, the DNA nucleosome, or molecules initiating oxidative stress in the nucleus, mitochondria, or extra-cellular matrix. On this scale, qualitatively distinct types of molecular damage are possible for high linear energy transfer (LET) radiation such as heavy ions compared to low LET radiation. Unique types of DNA lesions or oxidative damages are the likely outcome of the energy deposition. The frequency distribution for energy imparted to 1-20 nm targets per unit dose or particle fluence is a useful descriptor and can be evaluated as a function of impact parameter from an ions track. In this work, the simulation of 1-Gy irradiation of a cubic volume of 5 micron by: 1) 450 (1)H(+) ions, 300 MeV; 2) 10 (12)C(6+) ions, 290 MeV/amu and 3) (56)Fe(26+) ions, 1000 MeV/amu was done with the Monte-Carlo simulation code RITRACKS. Cylindrical targets are generated in the irradiated volume, with random orientation. The frequency distribution curves of the energy deposited in the targets is obtained. For small targets (i.e. <25 nm size), the probability of an ion to hit a target is very small; therefore a large number of tracks and targets as well as a large number of histories are necessary to obtain statistically significant results. This simulation is very time-consuming and is difficult to perform by using the original version of RITRACKS. Consequently, the code RITRACKS was adapted to use multiple CPU on a workstation or on a computer cluster. To validate the simulation results, similar calculations were performed using targets with fixed position and orientation, for which experimental data are available [5]. Since the probability of single- and double-strand breaks in DNA as function of energy deposited is well know, the results that were obtained can be used to estimate the yield of DSB, and can be extended to include other targeted or non-target effects.

Plante, Ianik↗

Preliminary results from the heavy ions in space experiment

The Heavy Ions In Space (HIIS) experiment is intended to provide a deep survey of intensely ionizing particles in low earth orbit. Intensely ionizing particles produce single event effects in microelectronic components and are now recognized as the principal cause of spacecraft anomalies. These particles also make an important contribution to radiation doses. Besides the practical applications, HIIS data will be used to study several important scientific questions. By measuring heavy ions that stop in HIIS, the anomalous component of cosmic rays can be studied, evidence can be searched for of heavy ions trapped in the earth's magnetic field and by comparing HISS data with observations from outside the magnetosphere, the mean ionic charge state can be determined of solar energetic particles. HIIS will also record relativistic ultraheavy galactic cosmic rays. Their elemental composition will be measured from tin to uranium. Results are presented on the elemental resolution for stopping heavy ions and relativistic heavy ions.

Adams, J. H., Jr.↗