Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “long term testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

VIIP 2017 Clinical Update

INTRODUCTION: NASA's Space Medicine community knowledge regarding the "Vision Impairment Intracranial Pressure", or VIIP.has been evolving over time.. Various measures of occupational health related to this condition had to be determined and then plans/processes put into place. The most robust of these processes were inititated in 2010. This presentation will provide a clinic update of the astronaut occupational health data related to VIIP. METHODS: NASA and its international partners require its astronauts to undergo routine health measures deemed important to monitoring VIIP. The concern is that the spaceflight environment aboard ISS could cause some astronauts to have physiologic changes detrimental to either ongoing mission operations or long-term health related to the ocular system and possibly the CNS. Specific medical tests include but are not limited to brain/orbit MRI (NASA unique protocol), OCT, fundoscopy and ocular ultrasound. Measures are taken prior to spaceflight, in-flight and post-flight. Measures to be reported include incidence of disc edema, globe flattening, choroidal folds, ONSD and change in refractive error. RESULTS: 73 ISS astronauts have been evaluated at least partially for VIIP related measures. Of these individuals, approximately 1 in 7 have experienced disc edema. The prevalence of the other findings is more complicated as the medical testing has changed over time. Overall, 26 separate individuals have experienced at least one of the findings NASA has associated with VIIP Another confounding factor is most of the astronauts have prior spaceflight experience at the time of the "pre-flight" testing. DISCUSSION: In 2010 NASA and its US operating segment (USOS) partners (CSA, ESA and JAXA) began routine occupational monitoring and data collection for most VIIP related changes. Interpretation of that data is extremely challenging for several reasons. For example, the determination of disc edema is the most complete finding as we have had highly qualified optometrists routinely and competently performing post-flight funduscopic exams for the entirety of the ISS program. Yet in 2013 NASA added OCT to our in-flight suite of eye exams. Shortly after routine screening with the OCT, a new term appeared within VIIP vernacular - "subclinical disc edema". OCT has much greater ability to measure change within the retina and provides significantly more data to analyze, understand and communicate out. Communicating VIIP data clearly adds even more challenge. Historically we've reported data per eye and not necessarily per person. This has led to difficulty in understanding how many individuals have experienced "VIIP" within the aerospace medicine community. The presenter will attempt to provide clear and concise communication of VIIP findings.

Tarver, William↗

ISS EVA80 EMU Water in the Helmet Failure and Associated Analytical Response

On March 23rd, 2022, during Extra-Vehicular Activity (EVA) 80 aboard the International Space Station (ISS) crew identified an 8-10-inch diameter thin film of water in the pressure bubble of the suit during repress. This launched an investigation to determine the cause of the water in the helmet as well as short- and long-term mitigation efforts to enable return to EVA as quickly as possible. The investigation analysis efforts in combination with hardware inspection and testing determined the most likely cause of the water in the helmet to be sublimator carryover as a result of high latent loading put on the system. In parallel with this investigation, efforts were being made to mitigate any future water in the helmet events. The short-term mitigation strategy developed is to install absorbent material in the pressure bubble to capture water as it enters the helmet before it can impact the astronauts. This hardware is referred to as the Helmet Absorption Band (HAB) and Helmet Absorption Pad – Extender (HAP-E). Longer-term mitigation strategies include a device to capture small water events before entering the helmet by installing a water capture system in the vent loop of the Extravehicular Mobility Unit (EMU). This effort is coined the T2 Water Capture System. Additionally, developing an on-orbit sublimator challenge test which will be able to verify sublimator performance before and after EVAs. The sublimator is the hardware which condenses water vapor and removes it from the vent loop, and this hardware is referred to as the EMU Moisture Injection Test System (EMITS). Based on the investigation and short-term water capture solutions the ISS Program decided to return to nominal EVAs on October 7, 2022. With the addition of the long-term mitigation strategies, the team hopes to be able to prevent any future water in the helmet events.

Veronica Lee Pizor↗

Space Shuttle reaction control system thruster metal nitrate removal and characterization

The Space Shuttle hypergolic primary reaction control system (PRCS) thrusters continue to fail-leak or fail-off at a rate of approximately 1.5 per flight, attributed primarily to metal nitrate formation in the nitrogen tetroxide (N2O4) pilot operated valves (POV's). The failures have continued despite ground support equipment (GSE) and subsystem operational improvements. As a result, the Johnson Space Center (JSC) White Sands Test Facility (WSTF) performed a study to characterize the contamination in the N204 valves. This study prompted the development and implementation of a highly successful flushing technique using deionized (DI) water and gaseous nitrogen (GN2) to remove the contamination while minimizing Teflon seat damage. Following flushing a comprehensive acceptance test is performed before the thruster is deemed recovered. Between the time WSTF was certified to process flight thrusters (March 1992) and September 1993, a 68 percent thruster recovery rate was achieved. The contamination flushed from these thrusters was analyzed and has provided insight into the corrosion process, which is reported in this publication. Additionally, the long-term performance of 24 flushed thrusters installed in the WSTF Fleet Leader Shuttle reaction control subsystem (RCS) test articles is being assessed. WSTF continues to flush flight and test article thrusters and compile data to investigate metal nitrate formation characteristics in leaking and nonleaking valves.

Saulsberry, R. L.↗

Cyclic Fiber Push-In Test Monitors Evolution of Interfacial Behavior in Ceramic Matrix Composites

SiC fiber-reinforced ceramic matrix composites are being developed for high-temperature advanced jet engine applications. Obtaining a strong, tough composite material depends critically on optimizing the mechanical coupling between the reinforcing fibers and the surrounding matrix material. This has usually been accomplished by applying a thin C or BN coating onto the surface of the reinforcing fibers. The performance of these fiber coatings, however, may degrade under cyclic loading conditions or exposure to different environments. Degradation of the coating-controlled interfacial behavior will strongly affect the useful service lifetime of the composite material. Cyclic fiber push-in testing was applied to monitor the evolution of fiber sliding behavior in both C- and BN-coated small-diameter (15-mm) SiC-fiber-reinforced ceramic matrix composites. The cyclic fiber push-in tests were performed using a desktop fiber push-out apparatus. At the beginning of each test, the fiber to be tested was aligned underneath a 10- mm-diameter diamond punch; then, the applied load was cycled between selected maximum and minimum loads. From the measured response, the fiber sliding distance and frictional sliding stresses were determined for each cycle. Tests were performed in both room air and nitrogen. Cyclic fiber push-in tests of C-coated, SiC-fiber-reinforced SiC showed progressive increases in fiber sliding distances along with decreases in frictional sliding stresses for continued cycling in room air. This rapid degradation in interfacial response was not observed for cycling in nitrogen, indicating that moisture exposure had a large effect in immediately lowering the frictional sliding stresses of C-coated fibers. These results indicate that matrix cracks bridged by C-coated fibers will not be stable, but will rapidly grow in moisture-containing environments. In contrast, cyclic fiber push-in tests of both BN-coated, SiC-fiber-reinforced SiC and BNcoated, SiC-fiber-reinforced barium strontium aluminosilicate showed no significant changes in fiber sliding behavior with continued short-term cycling in either room air or nitrogen. Although the composites with BN-coated fibers showed stable short-term cycling behavior in both environments, long-term (several-week) exposure of debonded fibers to room air resulted in dramatically increased fiber sliding distances and decreased frictional sliding stresses. These results indicate that although matrix cracks bridged by BNcoated fibers will show short-term stability, such cracks will show substantial growth with long-term exposure to moisture-containing environments. Newly formulated BN coatings, with higher moisture resistance, will be tested in the near future.

Eldridge, Jeffrey I.↗

Assessment of Countermeasure Efficacy for Long-Term Space Missions

One of the main functions of the upcoming International Space Station (ISS) will be to provide a venue for testing proposed countermeasures for their ability to protect humans from the debilitating effects of longterm space flight. However, several limiting factors preclude an evaluation process similar to that used in clinical trials which traditionally are implemented with large sample sizes of subjects, including control groups, and with blind or double-blind application of treatments according to factorial or other balanced experimental designs. In particular, only very limited numbers of human subjects will be available for actual field testing in the ISS With no more than 125 subjects planned to fly on all ISS missions over 10 years, it is not possible to test extensive combinations of some 15-20 proposed countermeasures. Furthermore because of safety concerns and operational considerations, it is unlikely that anything other than the current best guess at the most effective countermeasure package will ever be used on ISS. In particular, control or placebos will not be allowed. In view of these limitations, historical data and groundbased or animal studies will have to be used to compensate for small sample sizes and lack of controls in the field. As a result, statistical analysis methodology will have to be developed which allows for the integration of these disparate data types into a meaningful evaluation process. The process must be sequential, providing objective rules for deciding through time whether to reject or modify an ineffective countermeasure, or whether to certify one as effective. Additional output should include performance characteristics for all relevant physiological systems, including uncertainty analyses and estimates of accept/reject decision error rates.

Feiveson, Alan H.↗

Analysis of Hypervelocity-Impacted Thin Films for Space Applications

Exposure to the harsh space environment and hypervelocity impacts from micrometeoroids and small orbital debris can affect space operations through long-term degradation of spacecraft materials, surfaces, or systems. Multi-layer insulation (MLI) and coated, polyimide films are spacecraft materials commonly found on the external surfaces of spacecraft for thermal control and protection. Characterizing the damage to these exposed materials with in situ and laboratory measurements can better inform spacecraft designers and operators in understanding and mitigating surface or system degradation. In this paper, we examine flown Hubble Space Telescope (HST) Equipment Bay 5 MLI and coated, polyimide ground test articles to characterize hypervelocity impact damage. Impact feature cavities are inspected to identify damage, which can validate long-term degradation models, improve thermal management systems, or improve accuracy of damage predictions. An overview of the impact characterization using optical microscopy, narrowband spectroscopy, and Scanning Election Microscopy/Energy Dispersive X- ray (SEM/EDX) of the two materials is presented. Observations of robustness in the space environment, as well as a detailed assessment of cratering and penetration statistics for the space-exposed sample, also are discussed.

Melissa A. Ward↗

Test Hardware Design for Flightlike Operation of Advanced Stirling Convertors (ASC-E3)

NASA Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, the Thermal Energy Conversion branch at GRC has been conducting extended operation of a multitude of free-piston Stirling convertors. The goal of this effort is to generate long-term performance data (tens of thousands of hours) simultaneously on multiple units to build a life and reliability database. The test hardware for operation of these convertors was designed to permit in-air investigative testing, such as performance mapping over a range of environmental conditions. With this, there was no requirement to accurately emulate the flight hardware. For the upcoming ASC-E3 units, the decision has been made to assemble the convertors into a flight-like configuration. This means the convertors will be arranged in the dual-opposed configuration in a housing that represents the fit, form, and thermal function of the ASRG. The goal of this effort is to enable system level tests that could not be performed with the traditional test hardware at GRC. This offers the opportunity to perform these system-level tests much earlier in the ASRG flight development, as they would normally not be performed until fabrication of the qualification unit. This paper discusses the requirements, process, and results of this flight-like hardware design activity.

Oriti, Salvatore M.↗

Test Hardware Design for Flight-Like Operation of Advanced Stirling Convertors

NASA Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, the Thermal Energy Conversion branch at GRC has been conducting extended operation of a multitude of free-piston Stirling convertors. The goal of this effort is to generate long-term performance data (tens of thousands of hours) simultaneously on multiple units to build a life and reliability database. The test hardware for operation of these convertors was designed to permit in-air investigative testing, such as performance mapping over a range of environmental conditions. With this, there was no requirement to accurately emulate the flight hardware. For the upcoming ASC-E3 units, the decision has been made to assemble the convertors into a flight-like configuration. This means the convertors will be arranged in the dual-opposed configuration in a housing that represents the fit, form, and thermal function of the ASRG. The goal of this effort is to enable system level tests that could not be performed with the traditional test hardware at GRC. This offers the opportunity to perform these system-level tests much earlier in the ASRG flight development, as they would normally not be performed until fabrication of the qualification unit. This paper discusses the requirements, process, and results of this flight-like hardware design activity.

Oriti, Salvatore M.↗

Chemical Stability of the Fiber Coating/Matrix Interface in Silicon-Based Ceramic Matrix Composites

Carbon and boron nitride are used as fiber coatings in silicon-based composites. In order to assess the long-term stability of these materials, reactions of carbon/Si3N4 and BN/SiC were studied at high temperatures with Knudsen effusion, coupon tests, and microstructural examination. In the carbon/Si3N4 system, carbon reacted with Si3N4 to form gaseous N2 and SiC. The formation of SiC limited further reaction by physically separating the carbon and Si3N4. Consequently, the development of high p(N2) at the interface, predicted from thermochemical calculations, did not occur, thus limiting the potential deleterious effects of the reaction on the composite. Strong indications of a reaction between BN and SiC were shown by TEM and SIMS analysis of the BN/SiC interface. In long-term exposures, this reaction can lead to a depletion of a BN coating and/or an unfavorable change of the interfacial properties, limiting the beneficial effects of the coating.

Lee, Kang N.↗

Oculometric Biomarkers of Visuomotor Deficits in Clinically Asymptomatic Patients With Systemic Lupus Erythematosus Undergoing Long-Term Hydroxychloroquine Treatment

Introduction: This study examines a set of oculomotor measurements, or “oculometric” biomarkers, as potential early indicators of visual and visuomotor deficits due to retinal toxicity in asymptomatic Systemic Lupus Erythematosus (SLE) patients on long-term hydroxychloroquine (HCQ) treatment. The aim is to identify subclinical functional impairments that are otherwise undetectable by standard clinical tests and to link them to structural retinal changes. Methods: We measured oculomotor responses in a cohort of SLE patients on chronic HCQ therapy using a previously established behavioral task and analysis technique. We also examined the relationship between oculometrics, OCT measures of retinal thickness, and standard clinical perimetry measures of visual function in our patient group using Bivariate Pearson Correlation and a Linear Mixed-Effects Model (LMM). Results: Significant visual and visuomotor deficits were found in 12 asymptomatic SLE patients on long-term HCQ therapy compared to a cohort of 17 age-matched healthy controls. Notably, six oculometrics were significantly different. The median initial pursuit acceleration was 22%, steady-state pursuit gain 16%, proportion smooth 7%, and target speed responsiveness 31% lower, while catch-up saccade amplitude was 46% and fixation error 46% larger. Excluding the two patients with diagnosed mild toxicity, four oculometrics, all but fixation error and proportion smooth, remained significantly impaired compared to controls. Across our population of 12 patients (24 retinae), we found that pursuit latency, initial acceleration, steady-state gain, and fixation error were linearly related to retinal thickness even when age was accounted for, while standard measures of clinical function (Mean Deviation and Pattern Standard Deviation) were not. Discussion: Our data show that specific oculometrics are sensitive early biomarkers of functional deficits in SLE patients on HCQ that could be harnessed to assist in the early detection of HCQ-induced retinal toxicity and other visual pathologies, potentially providing early diagnostic value beyond standard visual field and OCT evaluations.

eye movements↗

Summary of Stirling Convertor Testing at NASA Glenn Research Center

The NASA Glenn Research Center (GRC) has been testing free-piston Stirling convertors for potential use in radioisotope power systems. These convertors tend to be in the 35 to 80 W electric power output range. Tests at GRC have accumulated over 80,000 hr of operation. Test articles have been received from Infinia Corporation of Kennewick, Washington and from Sunpower of Athens, Ohio. Infinia designed and built the developmental Stirling Technology Demonstration Convertors (TDC) in addition to the more advanced Test Bed and Engineering Unit convertors. GRC has eight of the TDC's under test including two that operate in a thermal vacuum environment. Sunpower designed and developed the EE-35 and the Advanced Stirling Convertor (ASC). GRC has six of the EE- 35 s and is preparing for testing multiple ASC s. Free-piston Stirling convertors for radioisotope power systems make use of non-contacting operation that eliminates wear and is suited for long-term operation. Space missions with radioisotope power systems are often considered that extend from three to 14 years. One of the key capabilities of the GRC test facility is the ability to support continuous, unattended operation. Hardware, software, and procedures for preparing the test articles were developed to support these tests. These included the processing of the convertors for minimizing the contaminants in the working fluid, developing a helium charging system for filling and for gas sample analysis, and the development of new control software and a high-speed protection circuit to insure safe, round-the-clock operation. Performance data of Stirling convertors over time is required to demonstrate that a radioisotope power system is capable of providing reliable power for multi-year missions. This paper will discuss the status of Stirling convertor testing at GRC.

Schreiber, Jeffrey G.↗

STOP Analysis and Optimization of a Very-Low-Distortion Space Instrument: HST WFC3 Case Study

New generation optical instruments with very demanding stability requirements are being proposed and developed for space applications. STOP (Structural-Thermal-Optical Performance) analysis and optimization is crucial in meeting the very tight distortion budgets of these instruments. This presentation outlines STOP analysis and optimization approach in the context of WFC3 (Wide-Field Camera 3), which is a radial instrument designed to replace the Wide-Field Planetary Camera 2 (WFPC2) of the Hubble Space Telescope (HST). WFC3 houses two separate channels, UVIS and IR, and will have greater throughput and sensitivity than WFPC2. WFC3 line-of-sight alignment budget for the UVIS and IR channels are as small as 10 and 20 milli-arcsec, respectively. Its optical bench is the most critical subsystem effecting the optical stability of WFC3 hence our effort concentrates on the design and analysis of the bench and its interfaces. Structural analysis has accompanied the mechanical design of the bench since the initial concept study. A high fidelity structural Finite Element Model (FEM) of the bench has been developed and used for minimizing its thermally induced distortions as well as sizing it to meet the stiffness and strength requirements of a Shuttle launch. The bench is a composite honeycomb panel box structure with a very low planar Coefficient of Thermal Expansion (CTE) of approximately 0.1 ppm/C. Optic components are mounted to super-INVAR inserts bonded into the panels. The bench is kinematically supported on three HST latches via interface struts, which are tailored to exhibit negative CTE to cancel out the thermal motions of the latches. The interface struts also incorporate flexure elements to minimize the mechanical distortions coming into the bench from its enclosure. Bench FEM is coupled with the enclosure FEM to quantify these effects. Short term or on-orbit STOP analysis includes distortion due to the temperature variations of the bench, the struts, and the enclosure. Long term or ground-to-orbit STOP analysis includes distortional effects of gravity release, desorption, and assembly in addition to the ground-to-orbit temperature variations. A rigorous testing program has been implemented for verifying the material properties and the analysis predictions. STOP analysis results demonstrate that both the short-term and the long-term alignment budgets will be met. Presentation will cover design and analysis details that are critical to a successful implementation of the STOP analysis and optimization process.

Kunt, Cengiz↗

BioNutrients-1: Development of an On-Demand Nutrient Production System for Long-Duration Missions

Future long-duration missions beyond low-Earth orbit will require advances in food technologies to address the documented problem of degradation of vitamins and nutrients in supplied foods stored long-term. To begin to address the issue of nutrient degradation, we are developing and flight-testing a platform biomanufacturing technology for in situ production of target nutrients. This technology is being tested over a five-year duration on the International Space Station (ISS). As part of the BioNutrients-1 project we have developed an on-demand system for the production of two carotenoids, β-carotene and zeaxanthin, by genetically engineering distinct strains of Saccharomyces cerevisiae, more commonly known as baker’s yeast. The on-orbit nutrient production packs contain a desiccated yeast strain and edible growth substrate. Once hydrated, the contents of the production packs are intended to grow and produce a desired amount of ready-to-consume nutrients. In this current version the production packs will not be consumed and future missions will require an inactivation of microorganisms before consumption. In addition to the on-orbit hydration of the production packs a series of valuable microorganisms are currently being stored in stasis packs on the ISS including probiotics organisms, bacterial strains used in yogurt production, and organisms with potential use for future biomanufacturing. Analysis of returned ISS stasis packs and ground controls will include multi-omics studies and provide insight into long-term survival of organisms stored in a space environment. Both stasis packs and hydrated production packs will be intermittently returned to Earth for analysis. Preliminary data from long-term storage studies of stasis packs stored on the ISS for 47 days versus their ground control counterparts have shown no significant difference in viability. Currently no production packs have been processed.

Yeast↗

Long term evaluation of grease type lubricants in selected environments

The operating life of grease-type lubricants in various environments is evaluated. The test equipment and procedures are described. The lubricants were placed in the rolling element bearings of hysteresis synchronous motors and exposed to environments of a vacuum at 60 C, a vacuum at 93.3 C, 10 psia oxygen at 90 percent relative humidity at 60 C, 14.7 psia air at 90 percent relative humidity at 60 C, start-stop operation, and low temperature start capability for one or five years. The weights of the bearings were measured before and after lubrication; the weight data for each environment are analyzed. The data reveal that the high viscosity index perfluoroalkypolyether grease performs the best in a vacuum at moderate and high temperature, in low temperature start capability, and in start-stop steps; however, the grease does not work well in oxidizing and high relative humidity environments.

Dolan, F. J.↗

Observed changes in a-Si:H cell characteristics due to long term temperature stress

Determination of thermally induced degradation mechanisms affecting thin film amorphous silicon solar cells through the use of laboratory accelerated stress testing requires acquisition of specially constructed, individually addressable test cells and the development of highly repeatable instrumentation which is not influenced by short-term reversible optical effects. This paper illustrates these considerations by describing accelerated temperature stress procedures and test results for one type of a-Si:H cell. Observed electrical characteristic changes indicate that two types of stress induced mechanisms are operating - one of which is self limiting and can be observed at lower temperatures and one which continues to complete degradation. The self limiting mechanism can result in a dramatic improvement to cells having initially low Voc values.

Lathrop, Jay W.↗

Survey of long-term durability of fiberglass reinforced plastic structures

Included are fluid containment vessels, marine structures, and aircraft components with up to 19 years of service. Correlations were obtained for the variation of static fatigue strength, cyclic fatigue strength, and residual burst strength for pressure vessels. In addition, data are presented for the effects of moisture on strength retention. Data variations were analyzed, and relationships and implications for testing are discussed. Change in strength properties for complete structures was examined for indications of the effects of environmental conditions such as moisture and outdoor exposure (ultraviolet radiation, weathering) on long term durability.

Lieblein, S.↗