Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Downward jetting of a dynamic Leidenfrost drop

Jetting is a universal phenomenon frequently observed in nature and industries, for instance in rain drop impact, inkjet printing, spray cooling, fuel atomization, etc. In drop impact on a superheated surface, we observe the formation of a vapor cavity beneath the dynamic Leidenfrost drop and a consecutive downward ejection of a jet into the cavity, using ultrafast x-ray phase contrast imaging. We reveal that the cavity is induced mostly by the retraction of the drop and the jetting is caused by the convergence of capillary waves along the liquid-cavity interface. We find a jetting criterion based on the viscous damping of capillary waves: [OhWe 2 ] ≤ 66 ± 10. These results can provide important insight that leads to understanding and modeling of jets in nature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Realistic fuel spray modeling for gasoline direct injection engine applications

Fuel spray modeling plays a critical role during modern gasoline direct injection (GDI) engine development due to fuel injection’s dominant impact on engine performance and emissions as well as the complex physical processes involved. In engineering three-dimensional (3D) computational fluid dynamics (CFD) simulations, the liquid-phase fuel atomization, evaporation, and mixing are usually modeled with the discrete droplet model (DDM) adopting a Lagrangian approach for multiphase CFD simulations. To this end, general practices heavily depend on the reduced order characterization of the injector nozzle flow. However, such simplified injector modeling may lead to insufficient representations of the complex spray dynamics. To tackle this problem, this study proposes a novel workflow to numerically evaluate GDI sub-cooled and flash-boiling sprays under engine-relevant conditions using a side-mounted GDI injector together with real gasoline fuel properties. The workflow introduces a one-way coupling (OWC) method leveraging high-fidelity nozzle flow simulations to provide realistic boundary conditions to the Lagrangian injector model. The proposed workflow was first verified in a constant volume chamber (CVC) environment and then implemented in a practical GDI engine setup to study spray morphology, fuel-air mixing, and wall-wetting propensity. In addition, detailed comparison was performed between the OWC method and the conventional rate of injection (ROI) routine. In conclusion, quantitative analysis of spray characteristics was conducted to highlight possible source of discrepancies of the conventional ROI method.

33 ADVANCED PROPULSION SYSTEMS↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Microwave Resonant Cavity Transducer Recalibration Procedures

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Inner diameter of the cylindrical cavity is 22.2 mm, and the thin wall is approximately 200µm thick. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Sodium flow rate sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed. From the measurements, we observed significant scatter in high temperature liquid sodium at low flow velocity values. Our hypothesis is that this is caused by temperature drift in the liquid, which results in thermal expansion of the cavity and a drift in the resonator frequency. In this report, we investigate temperature dependence of the resonant frequency through development of analytic models and preliminary analysis of experimental data. In addition, we develop a procedure for compensation for temperature drift during flow sensing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Understanding NBI heating and fueling in LTX-β tokamak

My work on the contract DE-SC=0023274 (July, 2022 - July, 2025) was focused on understanding the plasma fueling by NBI. On Dec. 1998 with Sergei Krasheninnikov (UCSD, San Diego, CA) we initiated the Li Wall Fusion (LiWFusion) as a new concept of magnetic fusion [1]. The new 1 2 plasma 3 4 5 6 2.1 Overview of rate coefficients, mean-free paths λH0 , and diffusions coefficients 6 2. GSV code for ⟨σv⟩ analysis of NBI fueling concept was a reaction of the lack of luck of tokamak fusion with QDT = 1 on TFTR and JET. We recognized the edge plasma cooling by recycling to be the route reason of the tokamak problems on the way to burning plasma. LiWFusion relies on plasma pumping by a lithium layer on the inner walls of the plasma chamber, combined with the plasma heating and fueling by the Neutral Beam Injection (NBI). These two innovations eliminate the route problem of the tokmak fusion. The concept became theoretically mature in 2006. In 2012, the technology of continuously Flowing Liquid Lithium (24/7-FLiLi) was invented by me for the future implementations of the LWFusion concept. At the same time, my every presentation on LiWFusion to International Symposium on Lithium Applications since 2010 was objected by some person with words “Everybody since the 1970s knows that plasma fueling by NBI is impossible”. I dropped the name of the author of this objection and ignored his views. My work on the current grant on NBI fueling of LTX-β not only clarified the issue but resolved it in an astonishing way. The NBI fueling was fully understood (thus humiliating the current dogmatic fusion community). The new future of LTX-β dedicated for decades to Li in tokamaks, as well as of the entire magnetic fusion program was envisioned, in sharp contrast with the fallure of OFES in the post-TFTR era of 21st century.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum spin nematic phase in a square-lattice iridate

Spin nematic is a magnetic analogue of classical liquid crystals, a fourth state of matter exhibiting characteristics of both liquid and solid. Particularly intriguing is a valence-bond spin nematic, in which spins are quantum entangled to form a multipolar order without breaking time-reversal symmetry, but its unambiguous experimental realization remains elusive. Here, in this study, we establish a spin nematic phase in the square-lattice iridate Sr 2 IrO 4 , which approximately realizes a pseudospin one-half Heisenberg antiferromagnet in the strong spin-orbit coupling limit. Upon cooling, the transition into the spin nematic phase at T C approximate to 263 K is marked by a divergence in the static spin quadrupole susceptibility extracted from our Raman spectra and concomitant emergence of a collective mode associated with the spontaneous breaking of rotational symmetries. The quadrupolar order persists in the antiferromagnetic phase below TN approximate to 230 K and becomes directly observable through its interference with the antiferromagnetic order in resonant X-ray diffraction, which allows us to uniquely determine its spatial structure. Further, we find using resonant inelastic X-ray scattering a complete breakdown of coherent magnon excitations at short-wavelength scales, suggesting a many-body quantum entanglement in the antiferromagnetic state. Taken together, our results reveal a quantum order underlying the Neel antiferromagnet that is widely believed to be intimately connected to the mechanism of high-temperature superconductivity. We establish a spin nematic phase in the square-lattice iridate Sr 2 IrO 4 and find a complete breakdown of coherent magnon excitations at short-wavelength scales, suggesting a many-body quantum entanglement in the antiferromagnetic state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CONDENSATION-EVAPORATION MODELING OF DRIFT FROM A MECHANICAL COOLING TOWER

Numerical studyfor investigatingthe phase change behavior of a drift from a mechanical draft cooling tower is presented. A k-ε turbulence model, discrete phase model, species transport equations, and a heat-mass exchange model are solved simultaneouslyto capture the heat and mass transfer effects of a drift condensing and evaporatingeffects. The simulation result is compared to an available real scale test data and its limitation is also discussed. A parametric study is carried out by varying the ambient dry bulb temperature, ambient relative humidity, wind speed, liquid droplet diameter, and the drift amount. It is found that by combining the evaporation and condensation models, a drift phase change phenomena is accurately depicted. A parametric study reveals that wind speed impact is affected by the ambient temperature and the number of liquid droplets and their size play a critical role in the phase change phen

Han, Kai↗

Transfer and Flushing Evaluation for Potential Precipitated Solids in the 241-AP-106 to EMF Transfer Pipeline for DFLAW

Waste transfer pipeline flushing is necessary to maintain pipeline performance, but added flush fluid increases the nuclear waste inventory. During the Direct Feed Low-Activity Waste (DFLAW) mission, waste transfer lines from the Interim Low-Activity Waste Storage Tank (i.e., 241-AP-106) to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility must have the capability of being flushed to prevent accumulation of solids and to mitigate corrosion concerns. Operational experience at Hanford has shown that the solids precipitation occurs during processing operations from dilute Hanford liquids. Pacific Northwest National Laboratory was requested to evaluate the potential precipitated solid particle transport and flushing operational capabilities of the AP-106 through the Effluent Management Facility (EMF) low-point drain LAW feed pipeline. The evaluation results do not provide operational requirements, but rather provide a scoping basis for understanding the potential operational significance of solids precipitation in the pipeline. The salt and aluminum phase solids most likely to precipitate from the LAW feeds during cooling, evaporation, or mixing have particle densities that are estimated to range from 1.62 to 2.78 g/mL and a spherical particle size range of 8 to 2100 μm, depending on the solid phase considered. Application of the method to calculate the critical deposition velocity required by TFC-ENG-STD-26 at conservatively bounding estimates for the solids concentrations demonstrates that potentially precipitated solids may deposit on the bottom of the transfer pipe invert at the lower LAW feed pipeline flow rate, but the upper LAW feed pipeline flow rate will likely prevent deposition. The system pressure limit for the AP-106 through the EMF low-point drain LAW feed pipeline likely exceeds any pressure loss at a calculated critical deposition velocity even for the most adverse potential precipitated solid. However, should solids settle as a result of no-flow conditions, the flow capabilities of the AP-106 through the EMF low-point drain LAW feed pipeline are shown, based on the available literature, to be potentially inadequate for effective flushing operations to remove solids, even at solids concentrations below the maximum specified for LAW feed. Thus, stepwise solids accumulations over multiple transfers may be an issue, and eventual line plugging may occur. Further inadequacies may potentially be realized should the cohesive nature of certain precipitates be accounted for.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A unified non-equilibrium phase change model for injection flow modeling

The homogenous relaxation model (HRM) is one of the most widely used models to describe the liquid- gas phase transition. However, in its original formulation, it is unable to handle multispecies vapor-liquid equilibrium (VLE), which limits its applicability to single-component fluids. In this work, a unified non-equilibrium phase change model that considers the VLE of multicomponent mixtures is proposed building upon the HRM's structure. A time factor is introduced to mimic the effect of different phase change timescales due to different mechanisms, e.g., cavitation, flash-boiling, and evaporation. Here to assess the model's performance, computational fluid dynamics simulations of the internal and near-nozzle injection flow of the Engine Combustion Network's Spray G injector were performed using the nine-component PACE-20 fuel with both the unified model and the original HRM. The predicted fuel density in the near-nozzle region matched well with X-ray tomography measurements. The simulation results indicated that, whereas the HRM failed to capture the vaporization due to convective mixing between the fuel and ambient gas, the unified model performed well in predicting the mixing-driven vaporization and the corresponding evaporative cooling. Further comparisons using the nine-component fuel formula and a single-component fuel surrogate demonstrated the unified model's ability to predict preferential vaporization, which affects the predictions of local mixture composition and rate of vaporization. Finally, it is shown that the unified model is capable of representing multiple phase change mechanisms, and the relaxation time factor plays an important role in determining the degree of phase change due to the different mechanisms.

33 ADVANCED PROPULSION SYSTEMS↗

New helium recapture and reliquefier system for Dynamic Nuclear Polarization at UNH.

A new helium recapture and reliquefaction system, consisting of a gas bag, recapture manifold, cooling chiller, cryogenic purifier and, a gas storage cylinder banks, has been installed in the dynamic nuclear polarized target lab at the University of New Hampshire. This new system has the capability to improve the efficiency of our capacity to do target polarization runs by recycling our cryogenic helium which would otherwise be lost during polarization operations. Our helium liquefier is rated upto 40 L/Day under normal full-capacity operations, and is rated for a capacity of 500 liquid liters of helium. I explain the initial installation process followed by a discussion of the challenges with installation, including issues of impurities which appeared during the initial operation of the system. Then I discuss how we overcame these difficulties. Finally, I discuss the function of the system during normal operation and the present situation of the helium recapture and reliquefaction processing in the UNH Lab.

Lama, Chhetra [Univ. of New Hampshire, Durham, NH ↗

A comparative study of solute trapping in Fe-(33–45 at%) Cu alloys manufactured by laser directed energy deposition

The high cooling rates in laser directed energy deposition (DED-LB) of alloys lead to substantial amounts of solute trapping as solute atoms cannot diffuse away from the solid/liquid interface before it advances. In some concentrated alloys, this results in supersaturated solid phases that form nanoscale hierarchical microstructures when the solute atoms precipitate out during reheating from subsequent laser passes. We choose the Iron-Copper (Fe-Cu) binary alloy as model system as it is chemically homogeneous in the liquid phase and has negligible solid solubility at room temperature. Two alloys with nominal compositions in atomic (at.) %, Fe67Cu33 and Fe55Cu45, were manufactured using DED-LB. Scanning transmission electron microscopy (STEM), energy dispersive spectroscopy (EDS) and wavelength dispersive spectroscopy (WDS) were used to characterize the nanostructures and heterogeneous chemical compositions. A non-equilibrium solute partitioning model was used to compute the supersaturated chemistries of the constituent phases and validated with experimentally measured compositions. The measured phase compositions of the two alloys were very similar, at roughly 12 at.% Cu and 4 at.% Fe in the α(bcc)-Fe and ε(fcc)-Cu phases respectively, despite having different processing parameters and mechanical behavior. This indicates that the total thermal history, that depends on both the processing parameters and laser scan pattern, plays a stronger role on the final microstructure evolution than just the initial quantity of trapped solute. In addition, we find that current non-equilibrium solute partitioning models applied on the continuum scale fall short of predicting accurate quantitative phase compositions in concentrated alloys, although the qualitative trends are captured correctly.

36 MATERIALS SCIENCE↗

Plasma Facing Components with Capillary Porous System and Liquid Metal Coolant Flow

Liquid metal can create a renewable protective surface on plasma facing components (PFC), with an additional advantage of deuterium pumping and the prospect of tritium extraction if liquid lithium (LL) is used and maintained below 450 C, the temperature above which LL vapor pressure begins to contaminate the plasma. LM can also be utilized as an efficient coolant, driven by the Lorentz force created with the help of the magnetic field in fusion devices. Capillary porous systems can serve as a conduit of LM and simultaneously provide stabilization of the LM flow, protecting against spills into the plasma. Recently a combination of a fast-flowing LM cooling system with a porous plasma facing wall (CPSF) was investigated [Khodak and Maingi (2021)]. The system takes an advantage of a magnetohydrodynamics velocity profile, as well as attractive LM properties to promote efficient heat transfer from the plasma to the LL at low pumping energy cost, relative to the incident heat flux on the PFC. In case of a disruption leading to excessive heat flux from the plasma to the LM PFCs, LL evaporation can stabilize the PFC surface temperature, due to high evaporation heat and apparent vapor shielding. The proposed CPSF was optimized analytically for the conditions of a Fusion Nuclear Science Facility [Kessel et al. (2019)]: 10T toroidal field and 10 MW/m2 peak incident heat flux. Computational fluid dynamics analysis confirmed that a CPSF system with 2.5 mm square channels can pump enough LL so that no additional coolant is needed.

High Heat Flux↗

Core design and performance of the Westinghouse lead fast reactor with UO 2 and MOX configurations

For this work, Westinghouse partnered with Argonne National Laboratory to design, model and optimize UO 2 - and MOX-fueled core designs for a medium size (950 MWt) Lead Fast Reactor that was pursued by Westinghouse. Using Argonne’s suite of reactor analysis codes together with Westinghouse fuel cost economic models, thousands of candidate cores were considered to achieve the economics-optimized cores presented in this paper. This optimization process considered detailed reactor physics, fuel performance, transient performance, and fuel economics models. The reactor performance of the resulting optimized UO 2 - and MOX-fueled core designs are described and compared in this paper. Both cores show fuel performance and transient behavior that is considered acceptable for the optimization presented herein, while further testing campaigns on material performance in high-temperature liquid lead will be required to confirm acceptability at the operating conditions chosen. A multi-batch strategy was selected for the UO 2 core for best fuel utilization with minimum fuel inventory costs. A single-batch fuel management was instead selected for the MOX core to maximize cycle length and minimize the impact of the longer refueling outage resulting from the higher decay heat of the discharged MOX fuel relative to the discharged UO 2 fuel, requiring a longer cooling time before dry-lift of discharged fuel could take place.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High throughput screening of ultra-thin electrocaloric materials enabled by additive manufacturing

Current HVAC systems can constitute as much as half of a building’s total energy consumption, depending on its use. More specifically cooling, particularly in hotter climates or for energy intensive applications, like data centers, can comprise between 10-30% of the total energy use. These cooling systems are largely comprised of compressor-based direct expansion systems and chilled water systems that use refrigerants or water, respectively, to reject heat. . Electrocaloric (EC) cycles present an eco-friendly alternative to these conventional processes.

36 MATERIALS SCIENCE↗

Tethered balloon-borne profile measurements of atmospheric properties in the cloudy atmospheric boundary layer over the Arctic sea ice during MOSAiC: Overview and first results

The tethered balloon-borne measurement system BELUGA (Balloon-bornE moduLar Utility for profilinG the lower Atmosphere) was deployed over the Arctic sea ice for 4 weeks in summer 2020 as part of the Multidisciplinary drifting Observatory for the Study of Arctic Climate expedition. Using BELUGA, vertical profiles of dynamic, thermodynamic, aerosol particle, cloud, radiation, and turbulence properties were measured from the ground up to a height of 1,500 m. BELUGA was operated during an anomalously warm period with frequent liquid water clouds and variable sea ice conditions. Three case studies of liquid water phase, single-layer clouds observed on 3 days (July 13, 23, and 24, 2020) are discussed to show the potential of the collected data set to comprehensively investigate cloud properties determining cloud evolution in the inner Arctic over sea ice. Simulated back-trajectories show that the observed clouds have evolved within 3 different air masses (“aged Arctic,” “advected over sea ice,” and “advected over open ocean”), which left distinct fingerprints in the cloud properties. Strong cloud top radiative cooling rates agree with simulated results of previous studies. The weak warming at cloud base is mostly driven by the vertical temperature profile between the surface and cloud base. In-cloud turbulence induced by the cloud top cooling was similar in strength compared to former studies. From the extent of the mixing layer, it is speculated that the overall cloud cooling is stronger and thus faster in the warm oceanic air mass. Larger aerosol particle number concentrations and larger sizes were observed in the air mass advected over the sea ice and in the air mass advected over the open ocean.

Arctic↗

Externally Heated Diamond ANvil Cell Experimentation (EH-DANCE) for studying materials and processes under extreme conditions

Externally heated diamond anvil cells provide a stable and uniform thermal environment, making them a versatile device to simultaneously generate high-pressure and high-temperature conditions in various fields of research, such as condensed matter physics, materials science, chemistry, and geosciences. The present study features the Externally Heated Diamond ANvil Cell Experimentation (EH-DANCE) system, a versatile configuration consisting of a diamond anvil cell with a customized microheater for stable resistive heating, bidirectional pressure control facilitated by compression and decompression membranes, and a water-cooled enclosure suitable for vacuum and controlled atmospheres. This integrated system excels with its precise control of both pressure and temperature for mineral and materials science research under extreme conditions. Here, we showcase the capabilities of the system through its successful application in the investigation of the melting temperature and thermal equation of state of high-pressure ice-VII at temperatures up to 1400 K. The system was also used to measure the elastic properties of solid ice-VII and liquid H 2 O using Brillouin scattering and Raman spectra of carbonates using Raman spectroscopy, highlighting the potential of the EH-DANCE system in high-pressure research.

Instruments & Instrumentation↗

GRIDCERF - Geospatial Raster Input Data for Capacity Expansion Regional Feasibility

The Geospatial Raster Input Data for Capacity Expansion Regional Feasibility (GRIDCERF) data package is a high-resolution product to evaluate siting suitability for renewable and non-renewable power plants in the conterminous United States. GRIDCERF offers hundreds of individual suitability layers for use with both renewable and non-renewable power plant technology configurations in a harmonized format that can be easily ingested by geospatially-enabled modeling software. It also provides pre-compiled technology-specific suitability layers and allows for user customization to robustly address science objectives when evaluating varying future conditions. GRIDCERF data can be directly used with the CERF (Capacity Expansion Regional Feasibility) model to site power plants at a 1km resolution. GRIDCERF includes composite technology siting suitability raster layers for the following utility scale technology configurations. Note that, in addition to technology sub-types shown below, various cooling types are also included (recirculating, pond, once-through, recirculating-seawater, dry-hybrid, or dry) for various technologies. Biomass Conventional (with or without CCS) IGCC (with or without CCS) Coal Conventional (with or without CCS) IGCC (with or without CCS) Natural Gas Combined-cycle (CC) (with or without CCS) Turbine Geothermal Enhanced Geothermal Systems (EGS) - Class 1 through Class 5 resource potential Nuclear Gen 2 Light Water Reactor (LWR) Gen 3 Small Modular Reactor (SMR) Gen 3 AP1000 Refined Liquids Combined-cycle (CC) (with or without CCS) Turbine Solar Photovoltaic (PV) - for capacity factors in the range of 6-18% Utility-scale Concentrating Solar Power (CSP) - for capacity factors in the range of 24-46% Tower Wind (Onshore) - for capacity factors in the range of 5-50% 80m hub height 100m hub height 120m hub height 140m hub height Wind (Offshore) - for capacity factors in the range of 25-60% 100m hub height 140m hub height 160m hub height

capacity expansion↗

GRIDCERF - Geospatial Raster Input Data for Capacity Expansion Regional Feasibility

The Geospatial Raster Input Data for Capacity Expansion Regional Feasibility (GRIDCERF) data package is a high-resolution product to evaluate siting suitability for renewable and non-renewable power plants in the conterminous United States. GRIDCERF offers hundreds of individual suitability layers for use with both renewable and non-renewable power plant technology configurations in a harmonized format that can be easily ingested by geospatially-enabled modeling software. It also provides pre-compiled technology-specific suitability layers and allows for user customization to robustly address science objectives when evaluating varying future conditions. GRIDCERF data can be directly used with the CERF (Capacity Expansion Regional Feasibility) model to site power plants at a 1km resolution. GRIDCERF includes composite technology siting suitability raster layers for the following utility scale technology configurations. Note that, in addition to technology sub-types shown below, various cooling types are also included (recirculating, pond, once-through, recirculating-seawater, dry-hybrid, or dry) for various technologies. Biomass Conventional (with or without CCS) IGCC (with or without CCS) Coal Conventional (with or without CCS) IGCC (with or without CCS) Natural Gas Combined-cycle (CC) (with or without CCS) Turbine Geothermal Enhanced Geothermal Systems (EGS) - Class 1 through Class 5 resource potential Nuclear Gen 2 Light Water Reactor (LWR) Gen 3 Small Modular Reactor (SMR) Gen 3 AP1000 Refined Liquids Combined-cycle (CC) (with or without CCS) Turbine Solar Photovoltaic (PV) - for capacity factors in the range of 6-18% Utility-scale Concentrating Solar Power (CSP) - for capacity factors in the range of 24-46% Tower Wind (Onshore) - for capacity factors in the range of 5-50% 80m hub height 100m hub height 120m hub height 140m hub height Wind (Offshore) - for capacity factors in the range of 25-60% 100m hub height 140m hub height 160m hub height

capacity expansion↗