Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “limits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

3d N=8 Lorentzian Bagger-Lambert-Gustavsson theory as a scaling limit of 3d superconformal N=6 Aharony-Bergman-Jafferis-Maldacena theory

We elaborate on the suggestion made in arXiv:0806.3498 that the 3d N=8 superconformal SU(N) Chern-Simons-matter theory of 'Lorentzian' Bagger-Lambert-Gustavson type (L-BLG) can be obtained by a scaling limit (involving sending the level k to infinity and redefining the fields) from the N=6 superconformal U(N)xU(N) Chern-Simons-matter theory of Aharony, Bergman, Jafferis, and Maldacena (ABJM). We show that to implement such limit in a consistent way one is to extend the ABJM theory by an Abelian 'ghost' multiplet. The corresponding limit at the 3-algebra level also requires extending the nonantisymmetric Bagger-Lambert 3-algebra underlying the ABJM theory by a negative-norm generator. We draw analogy with similar scaling limits discussed previously for bosonic Chern-Simons theory and comment on some implications of this relation between the ABJM and L-BLG theories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low mass neutralino dark matter in the minimal supersymmetric standard model with constraints from B{sub s{yields}{mu}}{sup +{mu}-} and Higgs boson search limits

An analysis of spin independent neutralino-proton cross sections {sigma}{sub SI}({chi}p) that includes this low mass region is given. The analysis is done in minimal supersymmetric standard model (MSSM) with radiative electroweak symmetry breaking (REWSB). It is found that cross sections as large as 10{sup -40} cm{sup 2} can be accommodated in MSSM within the REWSB framework. However, inclusion of sparticle mass limits from current experiments, as well as lower limits on the Higgs searches from the Tevatron, and the current experimental upper limit on B{sub s{yields}{mu}}{sup +{mu}-} significantly limit the allowed parameter space reducing {sigma}{sub SI}({chi}p) to lie below {approx}10{sup -41} cm{sup 2} or even lower for neutralino masses around 10 GeV. These cross sections are an order of magnitude lower than the cross sections needed to explain the reported data in the recent dark matter experiments in the low neutralino mass region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Upper limits on a possible gluon mass

We analyze upper limits on a possible gluon mass, m{sub g}. We first discuss various ways to modify quantum chromodynamics to include m{sub g{ne}}0, including a bare mass, a Higgs mechanism, and dynamical breaking of color SU(3){sub c}. From an examination of experimental data, we infer an upper limit m{sub g}<O(1) MeV. As part of our analysis, we show that a claim, hitherto unrefuted in the literature, of a much stronger upper limit on m{sub g}, is invalid. We discuss subtleties in interpreting gluon mass limits in view of the fact that at scales below {Lambda}{sub QCD}, quantum chromodynamics is strongly coupled, perturbation theory is not reliable, and the physics is not accurately described in terms of the Lagrangian degrees of freedom, including gluons. We also point out a fundamental difference in the behavior of quantum chromodynamics with a nonzero gluon mass and a weakly coupled gauge theory with a gauge boson mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exclusion limits from data of directional dark matter detectors

Directional detection is a promising search strategy to discover Galactic dark matter. Taking advantage on the rotation of the Solar System around the Galactic center through the dark matter halo, it allows us to show a direction dependence of weakly interacting massive particle (WIMP) events. Even though the goal of directional search is to identify a WIMP positive detection, exclusion limits are still needed for very low exposure with a rather large background contamination, such as the one obtained with prototype experiments. Data of directional detectors are composed of energy and a 3D track for all recoiling nuclei. However, to set robust exclusion limits, we focus on the angular part of the event distribution, arguing that the energy part of the background distribution is unknown. As the angular distributions of both background and WIMP events are known, a Bayesian approach to set exclusion limits is possible. In this paper, a new statistical method based on an extended likelihood is proposed, compared to existing ones, and is shown to be optimal. Eventually, a comprehensive study of the effect of a detector configuration on exclusion limits is presented. It includes the effect of having or not sense recognition, a finite angular resolution, taking into account energy threshold as well as some astrophysical uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Asymptotic spectrum of Kerr black holes in the small angular momentum limit

We study analytically the highly damped quasinormal modes of Kerr black holes in the small angular momentum limit. To check the previous analytic calculations in the literature, which use a combination of radial and tortoise coordinates, we reproduce all the results using the radial coordinate only. According to the earlier calculations, the real part of the highly damped quasinormal mode frequency of Kerr black holes approaches zero in the limit where the angular momentum goes to zero. This result is not consistent with the Schwarzschild limit where the real part of the highly damped quasinormal mode frequency is equal to c{sup 3}ln(3)/(8{pi}GM). In this paper, our calculations suggest that the highly damped quasinormal modes of Kerr black holes in the zero angular momentum limit make a continuous transition from the Kerr value to the Schwarzschild value. We explore the nature of this transition using a combination of analytical and numerical techniques. Finally, we calculate the highly damped quasinormal modes of the extremal case in which the topology of Stokes/anti-Stokes lines takes a different form.

79 ASTRONOMY AND ASTROPHYSICS↗

Limits on Nonstandard Forces in the Submicrometer Range

We report the search for a nonstandard force by measuring the Casimir forces in the 0.48-6.5 {mu}m range. By comparing the data and the theory of the Casimir force, we have obtained constraints for the parameter {alpha} of the Yukawa-type deviations from Newtonian gravity. The obtained limits are more stringent than previous limits in the 1.0-2.9 {mu}m range. Furthermore, we have obtained lower limits for the fundamental scale M{sub *} for gauged baryon number in the bulk. In particular, for six extra dimensions, the limits on M{sub *} are stringent in the range 6.5x10{sup -6}<{rho}<2.5x10{sup -4}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Surpassing the Energy Resolution Limit with Ferromagnetic Torque Sensors

We discuss the fundamental noise limitations of a ferromagnetic torque sensor based on a levitated magnet in the tipping regime. We evaluate the optimal magnetic field resolution taking into account the thermomechanical noise and the mechanical detection noise at the standard quantum limit. We find that the energy resolution limit, pointed out in recent literature as a relevant benchmark for most classes of magnetometers, can be surpassed by many orders of magnitude. Moreover, similarly to the case of a ferromagnetic gyroscope, it is also possible to surpass the standard quantum limit for magnetometry with independent spins, arising from spin-projection noise. Our finding indicates that magnetomechanical systems optimized for magnetometry can achieve a magnetic field resolution per unit volume several orders of magnitude better than any conventional magnetometer. Here, we discuss possible implications, focusing on fundamental physics problems such as the search for exotic interactions beyond the standard model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Classifying and assembling two-dimensional X-ray laser diffraction patterns of a single particle to reconstruct the three-dimensional diffraction intensity function: resolution limit due to the quantum noise

A new algorithm is developed for reconstructing the high-resolution three-dimensional diffraction intensity function of a globular biological macromolecule from many quantum-noise-limited two-dimensional X-ray laser diffraction patterns, each for an unknown orientation. The structural resolution is expressed as a function of the incident X-ray intensity and quantities characterizing the target molecule. A new two-step algorithm is developed for reconstructing the three-dimensional diffraction intensity of a globular biological macromolecule from many experimentally measured quantum-noise-limited two-dimensional X-ray laser diffraction patterns, each for an unknown orientation. The first step is classification of the two-dimensional patterns into groups according to the similarity of direction of the incident X-rays with respect to the molecule and an averaging within each group to reduce the noise. The second step is detection of common intersecting circles between the signal-enhanced two-dimensional patterns to identify their mutual location in the three-dimensional wavenumber space. The newly developed algorithm enables one to detect a signal for classification in noisy experimental photon-count data with as low as ∼0.1 photons per effective pixel. The wavenumber of such a limiting pixel determines the attainable structural resolution. From this fact, the resolution limit due to the quantum noise attainable by this new method of analysis as well as two important experimental parameters, the number of two-dimensional patterns to be measured (the load for the detector) and the number of pairs of two-dimensional patterns to be analysed (the load for the computer), are derived as a function of the incident X-ray intensity and quantities characterizing the target molecule.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Application of normal-mode refinement to X-ray crystal structures at the lower resolution limit

The application of a new normal-mode-based X-ray crystallographic refinement method to a total of eight structures of moderate resolution is illustrated. The structural refinement of large complexes at the lower resolution limit is often difficult and inefficient owing to the limited number of reflections and the frequently high-level structural flexibility. A new normal-mode-based X-ray crystallographic refinement method has recently been developed that enables anisotropic B-factor refinement using a drastically smaller number of thermal parameters than even isotropic refinement. Here, the method has been systematically tested on a total of eight systems in the resolution range 3.0–3.9 Å. This series of tests established the most applicable scenarios for the method, the detailed procedures for its application and the degree of structural improvement. The results demonstrated substantial model improvement at the lower resolution limit, especially in cases in which other methods such as the translation–libration–screw (TLS) model were not applicable owing to the poorly converged isotropic B-factor distribution. It is expected that this normal-mode-based method will be a useful tool for structural refinement, in particular at the lower resolution limit, in the field of X-ray crystallography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal Modeling and Limitations for Power Electronics Embedded in Medium-Voltage Cables

As next-generation energy technologies gain traction and power demand increases, the existing electrical infrastructure faces significant stress, prompting innovative solutions to enhance the grid's capacity and lifespan. This work explores the possibility of embedding medium-voltage (MV) power electronics directly inline with the cable, and the resulting thermal challenges. Since the majority of power distribution cables installed in the U.S. are passively cooled, the work focuses primarily on passive cooling, with an emphasis on the limitations of axial heat spreading within the cable. To date, literature on axial spreading of high incident heat loads on cables and cable environments is limited, typically reporting cases with <10 W of incident heat load. This work will explore the considerations, limits, and tradeoffs of cable-embedded heat loads significantly larger than the cable losses. Both external and internal effects are modeled analytically in nondimensional terms via a Biot number analysis, allowing fundamental limits and tradeoffs to be derived. The work culminates in the design and experimental validation of a cable-embedded thermal system capable of passively dissipating 300 W of heat from a coaxial SiC mosfet switch module over a length of 20 cm, thus validating the possibility of MV cable-embedded power electronics from a thermal standpoint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Criteria for Grid-Forming Inverters Transitioning Between Current Limiting Mode and Normal Operation

Here, this letter focuses on the fault recovery analysis of inverters using multi-loop droop based grid-forming control, taking into account different current limiting strategies. A criterion is proposed to determine when the inverter can exit the current limiting mode after fault clearance. The theoretical findings are verified through electromagnetic transient simulations using the direct (d)-axis priority-based current limiting method, circular current limiting method, and virtual impedance method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Latitudinal patterns of terrestrial phosphorus limitation over the globe

Abstract Phosphorus limitation on terrestrial plant growth is being incorporated into Earth system models. The global pattern of terrestrial phosphorus limitation, however, remains unstudied. Here, we examined the global‐scale latitudinal pattern of terrestrial phosphorus limitation by analysing a total of 1068 observations of aboveground plant production response to phosphorus additions at 351 forest, grassland or tundra sites that are distributed globally. The observed phosphorus‐addition effect varied greatly (either positive or negative), depending significantly upon fertilisation regime and production measure, but did not change significantly with latitude. In contrast, phosphorus‐addition effect standardised by fertilisation regime and production measure was consistently positive and decreased significantly with latitude. Latitudinal gradient in the standardised phosphorus‐addition effect was explained by several mechanisms involving substrate age, climate, vegetation type, edaphic properties and biochemical machinery. This study suggests that latitudinal pattern of terrestrial phosphorus limitation is jointly shaped by macro‐scale driving forces and the fundamental structure of life.

Hou, Enqing↗

Retrospective analysis of biochemical limitations to photosynthesis in 49 species: C 4 crops appear still adapted to pre‐industrial atmospheric [ CO 2 ]

Abstract Leaf CO 2 uptake ( A ) in C 4 photosynthesis is limited by the maximum apparent rate of PEPc carboxylation ( V pmax ) at low intercellular [CO 2 ] ( c i ) with a sharp transition to a c i ‐saturated rate ( V max ) due to co‐limitation by ribulose‐1:5‐bisphosphate carboxylase/oxygenase (Rubisco) and regeneration of PEP. The response of A to c i has been widely used to determine these two parameters. V max and V pmax depend on different enzymes but draw on a shared pool of leaf resources, such that resource distribution is optimized, and A maximized, when V max and V pmax are co‐limiting. We collected published A / c i curves in 49 C 4 species and assessed variation in photosynthetic traits between phylogenetic groups, and as a function of atmospheric [CO 2 ]. The balance of V max ‐ V pmax varied among evolutionary lineages and C 4 subtypes. Operating A was strongly V max ‐limited, such that re‐allocation of resources from V pmax towards V max was predicted to improve A by 12% in C 4 crops. This would not require additional inputs but rather altered partitioning of existing leaf nutrients, resulting in increased water and nutrient‐use efficiency. Optimal partitioning was achieved only in plants grown at pre‐industrial atmospheric [CO 2 ], suggesting C 4 crops have not adjusted to the rapid increase in atmospheric [CO 2 ] of the past few decades.

Pignon, Charles P.↗

Reactor scale simulations of ALD and ALE: Ideal and non-ideal self-limited processes in a cylindrical and a 300 mm wafer cross-flow reactor

Here, we have developed a simulation tool to model self-limited processes such as atomic layer deposition (ALD) and atomic layer etching inside reactors of arbitrary geometry as well the output of in situ quartz crystal microbalance and mass spectrometry. We have applied this model to two standard types of cross-flow reactors: a cylindrical tube reactor and a model 300 mm wafer reactor, and explored both ideal and nonideal self-limited kinetics. The model results are in agreement with experimental results and analytic expressions obtained using a simple plug-flow model for the cylindrical tube reactor. We also extended the simulations to consider two nonideal self-limited processes: soft-saturating processes characterized by a slow reaction pathway and processes where surface by-products can compete with the precursor for the same pool of adsorption sites. Our results show that it is possible to have a self-limited process with saturated yet inhomogeneous growth profiles due to the competition of reactor by-products. This is in agreement with experimental observations for titanium dioxide ALD from titanium tetraisopropoxide and titanium tetrachloride precursors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fundamental x-ray interaction limits in diagnostic imaging detectors: Spatial resolution

The practice of diagnostic x-ray imaging has been transformed with the emergence of digital detector technology. Although digital systems offer many practical advantages over conventional film-based systems, their spatial resolution performance can be a limitation. The authors present a Monte Carlo study to determine fundamental resolution limits caused by x-ray interactions in four converter materials: Amorphous silicon (a-Si), amorphous selenium, cesium iodide, and lead iodide. The ''x-ray interaction'' modulation transfer function (MTF) was determined for each material and compared in terms of the 50% MTF spatial frequency and Wagner's effective aperture for incident photon energies between 10 and 150 keV and various converter thicknesses. Several conclusions can be drawn from their Monte Carlo study. (i) In low-Z (a-Si) converters, reabsorption of Compton scatter x rays limits spatial resolution with a sharp MTF drop at very low spatial frequencies (<0.3 cycles/mm), especially above 60 keV; while in high-Z materials, reabsorption of characteristic x rays plays a dominant role, resulting in a mid-frequency (1-5 cycles/mm) MTF drop. (ii) Coherent scatter plays a minor role in the x-ray interaction MTF. (iii) The spread of energy due to secondary electron (e.g., photoelectrons) transport is significant only at very high spatial frequencies. (iv) Unlike the spread of optical light in phosphors, the spread of absorbed energy from x-ray interactions does not significantly degrade spatial resolution as converter thickness is increased. (v) The effective aperture results reported here represent fundamental spatial resolution limits of the materials tested and serve as target benchmarks for the design and development of future digital x-ray detectors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generation of a suite of 3D computer-generated breast phantoms from a limited set of human subject data

Purpose: The authors previously reported on a three-dimensional computer-generated breast phantom, based on empirical human image data, including a realistic finite-element based compression model that was capable of simulating multimodality imaging data. The computerized breast phantoms are a hybrid of two phantom generation techniques, combining empirical breast CT (bCT) data with flexible computer graphics techniques. However, to date, these phantoms have been based on single human subjects. In this paper, the authors report on a new method to generate multiple phantoms, simulating additional subjects from the limited set of original dedicated breast CT data. The authors developed an image morphing technique to construct new phantoms by gradually transitioning between two human subject datasets, with the potential to generate hundreds of additional pseudoindependent phantoms from the limited bCT cases. The authors conducted a preliminary subjective assessment with a limited number of observers (n= 4) to illustrate how realistic the simulated images generated with the pseudoindependent phantoms appeared. Methods: Several mesh-based geometric transformations were developed to generate distorted breast datasets from the original human subject data. Segmented bCT data from two different human subjects were used as the 'base' and 'target' for morphing. Several combinations of transformations were applied to morph between the 'base' and 'target' datasets such as changing the breast shape, rotating the glandular data, and changing the distribution of the glandular tissue. Following the morphing, regions of skin and fat were assigned to the morphed dataset in order to appropriately assign mechanical properties during the compression simulation. The resulting morphed breast was compressed using a finite element algorithm and simulated mammograms were generated using techniques described previously. Sixty-two simulated mammograms, generated from morphing three human subject datasets, were used in a preliminary observer evaluation where four board certified breast radiologists with varying amounts of experience ranked the level of realism (from 1 ='fake' to 10 ='real') of the simulated images. Results: The morphing technique was able to successfully generate new and unique morphed datasets from the original human subject data. The radiologists evaluated the realism of simulated mammograms generated from the morphed and unmorphed human subject datasets and scored the realism with an average ranking of 5.87 {+-} 1.99, confirming that overall the phantom image datasets appeared more 'real' than 'fake.' Moreover, there was not a significant difference (p > 0.1) between the realism of the unmorphed datasets (6.0 {+-} 1.95) compared to the morphed datasets (5.86 {+-} 1.99). Three of the four observers had overall average rankings of 6.89 {+-} 0.89, 6.9 {+-} 1.24, 6.76 {+-} 1.22, whereas the fourth observer ranked them noticeably lower at 2.94 {+-} 0.7. Conclusions: This work presents a technique that can be used to generate a suite of realistic computerized breast phantoms from a limited number of human subjects. This suite of flexible breast phantoms can be used for multimodality imaging research to provide a known truth while concurrently producing realistic simulated imaging data.

60 APPLIED LIFE SCIENCES↗

SU-E-J-155: Utilizing Varian TrueBeam Developer Mode for the Quantification of Mechanical Limits and the Simulation of 4D Respiratory Motion

Purpose: Use Varian TrueBeam Developer mode to quantify the mechanical limits of the couch and to simulate 4D respiratory motion. Methods: An in-house MATLAB based GUI was created to make the BEAM XML files. The couch was moved in a triangular wave in the S/I direction with varying amplitudes (1mm, 5mm, 10mm, and 50mm) and periods (3s, 6s, and 9s). The periods were determined by specifying the speed. The theoretical positions were compared to the values recorded by the machine at 50 Hz. HD videos were taken for certain tests as external validation. 4D Respiratory motion was simulated by an A/P MV beam being delivered while the couch moved in an elliptical manner. The ellipse had a major axis of 2 cm (S/I) and a minor axis of 1 cm (A/P). Results: The path planned by the TrueBeam deviated from the theoretical triangular form as the speed increased. Deviations were noticed starting at a speed of 3.33 cm/s (50mm amplitude, 6s period). The greatest deviation occurred in the 50mm- 3s sequence with a correlation value of −0.13 and a 27% time increase; the plan essentially became out of phase. Excluding these two, the plans had correlation values of 0.99. The elliptical sequence effectively simulated a respiratory pattern with a period of 6s. The period could be controlled by changing the speeds or the dose rate. Conclusion: The work first shows the quantification of the mechanical limits of the couch and the speeds at which the proposed plans begin to deviate. These limits must be kept in mind when programming other couch sequences. The methodology can be used to quantify the limits of other axes. Furthermore, the work shows the possibility of creating 4D respiratory simulations without using specialized phantoms or motion-platforms. This can be further developed to program patient-specific breathing patterns.

61 RADIATION PROTECTION AND DOSIMETRY↗

Limited-angle effect compensation for respiratory binned cardiac SPECT

Purpose: In cardiac single photon emission computed tomography (SPECT), respiratory-binned study is used to combat the motion blur associated with respiratory motion. However, owing to the variability in respiratory patterns during data acquisition, the acquired data counts can vary significantly both among respiratory bins and among projection angles within individual bins. If not properly accounted for, such variation could lead to artifacts similar to limited-angle effect in image reconstruction. In this work, the authors aim to investigate several reconstruction strategies for compensating the limited-angle effect in respiratory binned data for the purpose of reducing the image artifacts. Methods: The authors first consider a model based correction approach, in which the variation in acquisition time is directly incorporated into the imaging model, such that the data statistics are accurately described among both the projection angles and respiratory bins. Afterward, the authors consider an approximation approach, in which the acquired data are rescaled to accommodate the variation in acquisition time among different projection angles while the imaging model is kept unchanged. In addition, the authors also consider the use of a smoothing prior in reconstruction for suppressing the artifacts associated with limited-angle effect. In our evaluation study, the authors first used Monte Carlo simulated imaging with 4D NCAT phantom wherein the ground truth is known for quantitative comparison. The authors evaluated the accuracy of the reconstructed myocardium using a number of metrics, including regional and overall accuracy of the myocardium, uniformity and spatial resolution of the left ventricle (LV) wall, and detectability of perfusion defect using a channelized Hotelling observer. As a preliminary demonstration, the authors also tested the different approaches on five sets of clinical acquisitions. Results: The quantitative evaluation results show that the three compensation methods could all, but to different extents, reduce the reconstruction artifacts over no compensation. In particular, the model based approach reduced the mean-squared-error of the reconstructed myocardium by as much as 40%. Compared to the approach of data rescaling, the model based approach further improved both the overall and regional accuracy of the myocardium; it also further improved the lesion detectability and the uniformity of the LV wall. When ML reconstruction was used, the model based approach was notably more effective for improving the LV wall; when MAP reconstruction was used, the smoothing prior could reduce the noise level and artifacts with little or no increase in bias, but at the cost of a slight resolution loss of the LV wall. The improvements in image quality by the different compensation methods were also observed in the clinical acquisitions. Conclusions: Compensating for the uneven distribution of acquisition time among both projection angles and respiratory bins can effectively reduce the limited-angle artifacts in respiratory-binned cardiac SPECT reconstruction. Direct incorporation of the time variation into the imaging model together with a smoothing prior in reconstruction can lead to the most improvement in the accuracy of the reconstructed myocardium.

60 APPLIED LIFE SCIENCES↗