Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Expanding the color palette of bicolor-emitting nanocrystals

Owing to their bright and tunable luminescence spectra, nanocrystals appear as a unique playground for light source design. Displays and lighting require white light sources that combine several narrow lines. As Kasha's rule prevents the emission of hot carriers, blends of multiple nanocrystal populations are currently the obvious strategy for broad-band source design. However, a few reports suggest that bicolor emission can also be obtained from a single particle even under weak excitation if a careful design of the exciton scattering mechanism sufficiently slows down its relaxation pathways. A key challenge remains to maintain quantum confinement for color tunability in the same structure, while simultaneously achieving a large size to leverage the critical, slower exciton diffusion or relaxation down to the ground state. In this work, we demonstrate that 2D nanoplatelets offer an original opportunity for the design of confined and large heterostructures. We demonstrate that bicolor emission is not limited to green–red pair and show that blue–yellow and purple–green emissions can be obtained from CdSe/CdTe/CdSe core/crown/crown and CdSe/CdS core/crown heterostructures, respectively.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

In-situ synchrotron x-ray characterization of K 2 CsSb photocathode grown by ternary co-evaporation

K2CsSb is a promising photocathode candidate to serve as an electron source in next-generation light sources such as Free Electron Lasers (FEL) and Energy Recovery Linacs (ERL). As the traditional recipe for creation of K2CsSb photocathodes typically results in a rough surface that deteriorates electron beam quality, significant effort has been made to explore novel growth methods for K2CsSb photocathodes. In this paper, a method of ternary co-evaporation of K, Cs, and Sb is described. By using in-situ synchrotron X-ray techniques, the quality of the photocathode is characterized during and after the growth. K2CsSb photocathodes grown by this method on Si (100) and MgO (001) substrates show strong (222) texture, and the two photocathodes exhibit 1.7% and 3.4% quantum efficiencies at a wavelength of 530 nm, with a rms surface roughness of about 2-4 nm. This represents an order of magnitude reduction in roughness compared to typical sequential deposition and should result in a significant improvement in the brightness of the generated electron beam.

Ding, Z.↗

Synchrotron Based Microstructural Characterization Method Development for Pu Oxides

Identification of new plutonium oxide signatures is a high priority focus area of the technical nuclear forensics and nonproliferation communities. Comprehensive materials science studies of plutonium oxide are needed to advance the understanding of the microcrystalline properties and their relationship to macro-scale morphologies and signatures. Plutonium oxide particle growth is depenedent on the microcrystalline strucutures, grain size, and orientation. Microcrystalline structures have been found to vary for plutonium oxide based on the oxidation state of plutonium, concentration of reactants, and the physiochemical conditions of precipitation. Empirical observation confirms the relationship between processing conditions and particle morphology. High sensitivity, non destructive analysis of individual microcrystalline grains requires the use of bright sources of X-rays produced by synchrotron radiation, such as those at the Advanced Photon Source. The light source can reveal higher resolution crystallographic mapping, more sensitive chemical analysis, and higher fidelity morphological information than any current methods at SRNL.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Synchrotron Based Microstructural Characterization Method Development for Pu Oxides

Identification of new plutonium oxide signatures is a high priority focus area of the technical nuclear forensics and nonproliferation communities. Comprehensive materials science studies of plutonium oxide are needed to advance the understanding of the microcrystalline properties and their relationship to macro-scale morphologies and signatures. Plutonium oxide particle growth is depenedent on the microcrystalline strucutures, grain size, and orientation. Microcrystalline structures have been found to vary for plutonium oxide based on the oxidation state of plutonium, concentration of reactants, and the physiochemical conditions of precipitation. Empirical observation confirms the relationship between processing conditions and particle morphology. High sensitivity, non destructive analysis of individual microcrystalline grains requires the use of bright sources of X-rays produced by synchrotron radiation, such as those at the Advanced Photon Source. The light source can reveal higher resolution crystallographic mapping, more sensitive chemical analysis, and higher fidelity morphological information than any current methods at SRNL Progress of FY19 was the analysis of the synchrotron data. Areas of focus included XANES oxidation state and EXAFS to measure bond distances with modeling. Most measurements for XANES indicated that the plutonium was in the +4 oxidation state, however, some indicated that there could also be a +5 oxidation state. The EXAFS measurements showed typical Pu – O bonding distance of 2.33 and Pu – Pu bonding distances of 3.81 A; however, some samples also showed that there could be shorter Pu – O distances of approximately 1.81 A, indicative of plutonium in the +5 oxidation state.

36 MATERIALS SCIENCE↗

OLED Lighting in the Offices of DeJoy, Knauf & Blood, LLP (Final Report)

The new offices of DeJoy, Knauf, & Blood, LLP in Rochester NY feature all solid state lighting, with eight different types of organic light-emitting diode luminaires. This was a chance to see and document the performance of an architectural space using OLEDs, in terms of efficacy, color, flicker, light levels, visual comfort, energy use, dimming, and appearance. Although the efficacy ranges of the luminaires are still well below the performance of LEDs, the installation demonstrates a solid state light source that is planar rather than a point source of light. Reported user acceptance was very high. Four luminaires were photometered by an independent laboratory so that future performance could be tracked.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optical memory

Optical memory comprising: a semiconductor wire, a first electrode, a second electrode, a light source, a means for producing a first voltage at the first electrode, a means for producing a second voltage at the second electrode, and a means for determining the presence of an electrical voltage across the first electrode and the second electrode exceeding a predefined voltage. The first voltage, preferably less than 0 volts, different from said second voltage. The semiconductor wire is optically transparent and has a bandgap less than the energy produced by the light source. The light source is optically connected to the semiconductor wire. The first electrode and the second electrode are electrically insulated from each other and said semiconductor wire.

30 DIRECT ENERGY CONVERSION↗

HPE ultralit project (ARPA-E open program 2018) final report 15

The goal of the program was to build a fully integrated optical transceiver with >1 Tb/s and <1.5 pJ/bit operating at 50 ◦ C. Optical transceivers are critical components in high-performance-computers (HPC) and data centers, and the details of their implementation has a big impact on the total power consumption (energy efficiency) of an HPC system. Our proposed transceiver used three key enabling technologies. Firstly, SiGe avalanche photodetectors have record-low sensitivities, meaning that they can reach low bit error rates with very little light input. As a result, we can drive our lasers at a lower drive current, thus saving electrical power. Secondly, we use MOS-based capacitive tuning in our deinterleaver, modulator, and demultiplexer. Capacitive tuning allows for the tuning of photonic elements with zero static power consumption. Thirdly, we use quantum dots as the gain material in our light source. This allows us to efficiently use our light source at temperatures that are typically encountered in an HPCsystem. Our proposed optical transceiver consisted of a quantum dot comb laser as a light source, a booster SOA, MOS-based deinterleavers, MOS based ring modulators, MOS-based ring demultiplexers, and SiGe APDs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A short working distance multiple crystal x-ray spectrometer

For x-ray spot sizes of a few tens of microns or smaller, a millimeter-sized flat analyzer crystal placed {approx}1 cm from the sample will exhibit high energy resolution while subtending a collection solid angle comparable to that of a typical spherically bent crystal analyzer (SBCA) at much larger working distances. Based on this observation and a nonfocusing geometry for the analyzer optic, we have constructed and tested a short working distance (SWD) multicrystal x-ray spectrometer. This prototype instrument has a maximum effective collection solid angle of 0.14 sr, comparable to that of 17 SBCA at 1 m working distance. We find good agreement with prior work for measurements of the Mn K{beta} x-ray emission and resonant inelastic x-ray scattering for MnO, and also for measurements of the x-ray absorption near-edge structure for Dy metal using L{alpha}{sub 2} partial-fluorescence yield detection. We discuss future applications at third- and fourth-generation light sources. For concentrated samples, the extremely large collection angle of SWD spectrometers will permit collection of high-resolution x-ray emission spectra with a single pulse of the Linac Coherent Light Source. The range of applications of SWD spectrometers and traditional multi-SBCA instruments has some overlap, but also is significantly complementary.

36 MATERIALS SCIENCE↗

Advanced X-ray Optics Metrology for Nanofocusing and Coherence Preservation

What is the point of developing new high-brightness light sources if beamline optics won't be available to realize the goals of nano-focusing and coherence preservation? That was one of the central questions raised during a workshop at the 2007 Advanced Light Source Users Meeting. Titled, 'Advanced X-Ray Optics Metrology for Nano-focusing and Coherence Preservation', the workshop was organized by Kenneth Goldberg and Valeriy Yashchuk (both of Lawrence Berkeley National Laboratory, LBNL), and it brought together industry representatives and researchers from Japan, Europe, and the US to discuss the state of the art and to outline the optics requirements of new light sources. Many of the presentations are viewable on the workshop website http://goldberg.lbl.gov/MetrologyWorkshop07/. Many speakers shared the same view of one of the most significant challenges facing the development of new high-brightness third and fourth generation x-ray, soft x-ray, and EUV light sources: these sources place extremely high demands on the surface quality of beamline optics. In many cases, the 1-2-nm surface error specs that define the outer bounds of 'diffraction-limited' quality are beyond the reach of leading facilities and optics vendors. To focus light to 50-nm focal spots, or smaller, from reflective optics and to preserve the high coherent flux that new sources make possible, the optical surface quality and alignment tolerances must be measured in nano-meters and nano-radians. Without a significant, well-supported research effort, including the development of new metrology techniques for use both on and off the beamline, these goals will likely not be met. The scant attention this issue has garnered is evident in the stretched budgets and limited manpower currently dedicated to metrology. With many of the world's leading groups represented at the workshop, it became clear that Japan and Europe are several steps ahead of the US in this critical area. But the situation isn't all dire: several leading groups are blazing a trail forward, and the recognition of this issue is increasing. The workshop featured eleven invited talks whose presenters came from Japan, Europe, and the US.

36 MATERIALS SCIENCE↗

Optical sedimentation recorder

A robotic optical sedimentation recorder is described for the recordation of carbon flux in the oceans wherein both POC and PIC particles are captured at the open end of a submersible sampling platform, the captured particles allowed to drift down onto a collection plate where they can be imaged over time. The particles are imaged using three separate light sources, activated in sequence, one source being a back light, a second source being a side light to provide dark field illumination, and a third source comprising a cross polarized light source to illuminate birefringent particles. The recorder in one embodiment is attached to a buoyancy unit which is capable upon command for bringing the sedimentation recorder to a programmed depth below the ocean surface during recordation mode, and on command returning the unit to the ocean surface for transmission of recorded data and receipt of new instructions. The combined unit is provided with its own power source and is designed to operate autonomously in the ocean for extended periods of time.

47 OTHER INSTRUMENTATION↗

Phosphors for near UV-Emitting LED's for Efficacious Generation of White Light

1) We studied phosphors for near-UV (nUV) LED application as an alternative to blue LEDs currently being used in SSL systems. We have shown that nUV light sources could be very efficient at high current and will have significantly less binning at both the chip and phosphor levels. We identified phosphor blends that could yield 4100K lamps with a CRI of approximately 80 and LPWnUV,opt equal to 179 for the best performing phosphor blend. Considering the fact that the lamps were not optimized for light coupling, the results are quite impressive. The main bottleneck is an optimum blue phosphor with a peak near 440 nm with a full width half maximum of about 25 nm and a quantum efficiency of >95%. Unfortunately, that may be a very difficult task when we want to excite a phosphor at ~400 nm with a very small margin for Stokes shift. Another way is to have all the phosphors in the blend having the excitation peak at 400 nm or slightly shorter wavelength. This could lead to a white light source with no body color and optimum efficacy due to no self-absorption effects by phosphors in the blend. This is even harder than finding an ideal blue phosphor, but not necessarily impossible. 2) With the phosphor blends identified, light sources using nUV LEDs at high current could be designed with comparable efficacy to those using blue LEDs. It will allow us to design light sources with multiple wattages using the same chips and phosphor blends simply by varying the input current. In the case of blue LEDs, this is not currently possible because varying the current will lower the efficacy at high current and alter the color point. With improvement of phosphor blends, control over CRI could improve. Less binning at the chip level and also at the phosphor blend level could reduce the cost of SSL light sources. 3) This study provided a deeper understanding of phosphor characteristics needed for LEDs in general and nUV LEDs in particular. Two students received Ph.D. degrees and three undergraduates participated in this work. Two of the undergraduate students are now in graduate school. The results were widely disseminated – 20 archival journal publications (published, accepted or in preparation) and three conference proceedings resulted. The students presented their work at 11 different national/international conferences (32 oral or poster presentations) and the PI’s delivered 12 invited, keynote or plenary lectures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Time-resolved spectroscopy using a chopper wheel as a fast shutter

Widely available, small form-factor, fiber-coupled spectrometers typically have a minimum exposure time measured in milliseconds, and thus cannot be used directly for time-resolved measurements at the microsecond level. Spectroscopy at these faster time scales is typically done with an intensified charge coupled device (CCD) system where the image intensifier acts as a “fast” electronic shutter for the slower CCD array. In this paper, we describe simple modifications to a commercially available chopper wheel system to allow it to be used as a “fast” mechanical shutter for gating a fiber-coupled spectrometer to achieve microsecond-scale time-resolved optical measurements of a periodically pulsed light source. With the chopper wheel synchronized to the pulsing of the light source, the time resolution can be set to a small fraction of the pulse period by using a chopper wheel with narrow slots separated by wide spokes. Different methods of synchronizing the chopper wheel and pulsing of the light sources are explored. The capability of the chopper wheel system is illustrated with time-resolved measurements of pulsed plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LED lamp incorporating remote phosphor with heat dissipation features

An LED lamp or bulb is disclosed that comprises a light source, a heat sink structure and a remote planar phosphor carrier having at least one conversion material. The phosphor carrier can be remote to the light sources and mounted to the heat sink so that heat from the phosphor carrier spreads into the heat sink. The phosphor carrier can comprise a thermally conductive transparent material and a phosphor layer, with an LED based light source mounted to the heat sink such that light from the light source passes through the phosphor carrier. At least some of the LED light is converted by the phosphor carrier, with some lamp embodiments emitting a white light combination of LED and phosphor light. The phosphor arranged according to the present invention can operate at lower temperature to thereby operate at greater phosphor conversion efficiency and with reduced heat related damage to the phosphor.

36 MATERIALS SCIENCE↗

Synchrotron Light Options at Super-B

Super-B is a planned asymmetric high luminosity e{sup +}e{sup -} collider at the {Upsilon}(4S) resonance as PEP-II and KEKB, to be built in Italy. The Super-B High (HER, 7 GeV) and Low (LER, 4 GeV) Energy beams characteristics are comparable to NSLS-II and other state of the art synchrotron light sources. This suggests the use of this facility, either parasitically or in dedicated runs, as light source. In this paper we compare the characteristics of the synchrotron light generated at Super-B with existing, in construction and proposed facilities. We investigate different schemes to incorporate the generation of synchrotron radiation in the collider lattice design and look at different beam line layouts for users. In the past high energy particle colliders were designed to collide as many particle as possible. This was done by maximizing the beam current, using relative large emittances and squeezing the beam at the interaction point. During the operation of PEP II the limits of both raising the beam currents and squeezing the beam were experienced. Therefore the optics was modified to lower emittance. The successful test of the 'large Piwinski angle' and crab waist scheme, with extremely low design emittances, at the DAPHNE collider at Frascati made it the design choice for Super-B. Both HER and LER have been designed to meet these requirements and the design parameters relevant to our study, are shown in Table 1. As comparison the design parameters from NSLS II and other state of the art synchrotron light sources have been added to this table. From these parameters it is obvious that synchrotron radiation generated from both HER and LER is comparable to this last generation sources.

43 PARTICLE ACCELERATORS↗

Studies and optimization of Pohang Light Source-II superconducting radio frequency system at stable top-up operation with beam current of 400 mA

After three years of upgrading work, the Pohang Light Source-II (PLS-II) is now successfully operating. The final quantitative goal of PLS-II is a top-up user-service operation with beam current of 400 mA to be completed by the end of 2014. During the beam store test up to 400 mA in the storage ring (SR), it was observed that the vacuum pressure around the radio frequency (RF) window of the superconducting cavity rapidly increases over the interlock level limiting the availability of the maximum beam current storing. Although available beam current is enhanced by setting a higher RF accelerating voltage, it is better to keep the RF accelerating voltage as low as possible in the long time top-up operation. We investigated the cause of the window vacuum pressure increment by studying the changes in the electric field distribution at the superconducting cavity and waveguide according to the beam current. In our simulation, an equivalent physical modeling was developed using a finite-difference time-domain code. The simulation revealed that the electric field amplitude at the RF window is exponentially increased as the beam current increases, thus this high electric field amplitude causes a RF breakdown at the RF window, which comes with the rapid increase of window vacuum pressure. The RF accelerating voltage of PLS-II RF system was set to 4.95 MV, which was estimated using the maximum available beam current that works as a function of RF voltage, and the top-up operation test with the beam current of 400 mA was successfully carried out.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent activities of National Synchrotron Light Source-II Insertion Device Group

Insertion Device (ID) Group at the National Synchrotron Light Source-II (NSLS-II) has been involved in the following activities: Installation and maintenance of the HEX-Superconducting Wiggler (SCW), Laboratory Directed Research and Development (LDRD) for SC adaptive gap undulator (AGU), NSLS-II Experimental Tools II & III (NEXT-II & III) project IDs. Improvement of in-vacuum flip coil bench, development of in-vacuum pulsed wire bench and upgrade of a regular flip coil bench. Development of rotating coil bench for the lattice magnets for future upgrade. This paper describes the specifics of each activity.

47 OTHER INSTRUMENTATION↗

Compact imaging system using a co-linear, high-intensity LED illumination unit to minimize window reflections for background-oriented schlieren, shadowgraph, photogrammetry and machine vision measurements

One aspect of the present disclosure is an imaging system including an optical sensor defining an optical axis. The system further includes a light source. The system may include an optical beam splitter, and may also include an optional diffusing lens that may be configured to diffuse and/or collimate light from the light source and direct light exiting the diffusing lens to the optical beam splitter. The optical beam splitter is configured to direct light from the light source along the optical axis of the optical sensor.

Bathel, Brett F.↗

Synchrotron X-Ray Microprobe and Microspectroscopy Research in Low Temperature Geochemistry

The project focuses on low temperature geochemistry applications of X-ray fluorescence microprobes primarily at the National Synchrotron Light Source (NSLS-I) but also at National Synchrotron Light Source II (NSLS-II), Brookhaven National Laboratory (BNL), Upton, NY. The microprobes can be used to determine the composition, structure, oxidation state, and bonding characteristics of earth materials with trace element sensitivity and micrometer spatial resolution. Investigators on this project are members of the Center for Advanced Radiation Sources (CARS) at the University of Chicago, a team that developed and managed the highly-successful microprobe beamline X26A at the National Synchrotron Light Source I (NSLS-I) at BNL from the 1980s until the closing of NSLS-I in September 2014. The closing of NSLS-I coincided with the start-up of the newly-constructed, 3 rd -generation synchrotron NSLS-II, also at BNL. During the course of this project, a subaward was let to the University of Kentucky to partially support the efforts of a technician at the beamlines.

36 MATERIALS SCIENCE↗