Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light modulated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Fiber-optic photoelastic pressure sensor with fiber-loss compensation

A new fiber-optic pressure sensor is described that has high immunity to the effects of fiber-loss variations. This device uses the photoelastic effect to modulate the proportion of the light from each of two input fibers that is coupled into each of two output fibers. This four-fiber link permits two detectors to be used to measure the sensor's responses to the light from each of two independently controlled sources. These four detector outputs are processed to yield a loss-compensated signal that is a stable and sensitive pressure indicator.

Beheim, G.↗

Loss-compensation of intensity-modulating fiber-optic sensors

This report describes a new type of intensity-modulating fiber-optic sensor which as high immunity to the effects of variations in the losses of the fiber-link. A variable-splitting-ratio transducer is used to differentially modulate the intensities of the light which it transmits and reflects. Using a four-fiber optical link, light is impinged onto the transducer from either direction, and, in each case, the transmitted and reflected signals are measured. These four signals are then processed to remove the effects of the fiber and connector losses. Loss-compensated sensors of angular position and displacement are described, and their outputs are shown to be highly stable despite considerable variations in the transmissivities of the fiber-link components.

Beheim, Glenn↗

Integrated Optoelectronic Interface

Proposed optoelectronic integrated-circuit device serves as "universal" or standard interface for transmission and reception of digital and analog signals in communication, data-processing, and control systems. Eliminates need for custom design of interface circuitry in sense that it embodies "master-chip" design easily adaptable to use with specific equipment. Includes directly modulated semiconductor laser to generate light signals for transmission along optical fiber; positive/intrinsic/negative, avalanche, or other photodiode to detect light signals received along another optical fiber;and driving, synchronizing, preamplifying, and signal-regenerating circuitry. Muliplexes electronic signals before transmission and/or demultiplexes electronic signals after reception.

Katz, Joseph↗

IUE and optical data during the low state of H0538 + 608 (BY Camelopardalis)

IUE short- and long-wavelength spectra, CCD differential BR photometry, and a portion of a J light curve were obtained during January-March 1989 when H0538 + 608 (BY Cam) was in a low state about 3 magnitudes below its normal high-state V magnitude. The IUE short-wavelength spectrum showed that all the strong emission lines apparent at the high state had disappeared while the continuum flux had decreased by about a factor of 3. The B and R data show large (0.8 and 1.5 mag) spikelike increases in light near phase 0.75, while the B light curve shows a slow modulation with peak intensity near phase 0.3. The implications are that both poles are still producing some emission, although the accretion onto the main pole is much reduced from the high-state value. In comparison to the low state of AM Her, the UV and IR fluxes would be consistent with viewing a hot white dwarf and a late-main-sequence secondary at a distance of several hundred pc.

Szkody, Paula↗

Hyperspectral Imaging and Spectroscopy of Fluorescently Coupled Acyl-CoA: Cholesterol Acyltransferase in Insect Cells

A high-performance hyperspectral imaging module with high throughput of light suitable for low-intensity fluorescence microscopic imaging and subsequent analysis, including single-pixel-defined emission spectroscopy, was tested on Sf21 insect cells expressing green fluorescence associated with recombinant green fluorescent protein linked or not with the membrane protein acyl-CoA:cholesterol acyltransferase. The imager utilized the phenomenon of optical activity as a new technique providing information over a spectral range of 220-1400 nm, and was inserted between the microscope and an 8-bit CCD video-rate camera. The resulting fluorescence image did not introduce observable image aberrations. The images provided parallel acquisition of well resolved concurrent spatial and spectral information such that fluorescence associated with green fluorescent protein alone was demonstrated to be diffuse within the Sf21 insect cell, and that green fluorescence associated with the membrane protein was shown to be specifically concentrated within regions of the cell cytoplasm. Emission spectra analyzed from different regions of the fluorescence image showed blue shift specific for the regions of concentration associated with the membrane protein.

Malak, H.↗

1393 Ring Bus at JPL: Description and Status

Completed Ring Bus IC V&V Phase - Ring Bus Test Plan Completed for SIM Project - Applicable to Other Projects Implemented a Avionics Bus Based upon the IEEE 1393 Standard - Excellent Starting Point for a General Purpose High-Speed Spacecraft Bus - Designed to Meet SIM Requirements for - Real-time deterministic, distributed systems. - Control system requirements - Fault detection and recovery Other JPL Projects Considering Implementation F'light Software Ring Bus Driver Module Began in 2006, Continues Participating in Standard Revision. Search for Earth-like planets orbiting nearby stars and measure the masses and orbits of the planets it finds. Survey 2000 nearby stars for planetary systems to learn whether our Solar System is unusual, or typical. Make a new catalog of star position 100 times more accurate than current measurements. Learn how our galaxy formed and will evolve by studying the dynamics of its stars. Critically test models of exactly how stars shine, including exotic objects like black holes, neutron stars and white dwarfs.

time synchronization↗

Improving Quantitative Laboratory Analysis of Phycobiliproteins to Provide High Quality Validation Data for Ocean Color Remote Sensing Algorithm

Identification and characterization of phytoplankton communities and their physiology is a primary aim of NASA's PACE satellite mission. The concentration and composition of phytoplankton pigments modulate the spectral distribution of light emanating from the ocean, which is measured by ocean color satellites, and thus provide critical information on phytoplankton community composition and physiological parameters. One diagnostic class of pigments not routinely well-characterized is the phycobiliproteins (PBPs), and NASA has a requirement to collect and distribute high quality in situ data in support of data product validation activities for ocean color missions. Phycobiliproteins are light-harvesting proteins that are the predominant photosynthetic pigments in some classes of phytoplankton including cyanobacteria, such as Synechococcus, Trichodesmium, and Microcystis. With the advance of hyperspectral ocean color sensors such as on PACE (expected to launch in late 2022), it is essential that we implement routine analysis of PBPs that satisfies several considerations: reproducible, high extraction efficiency for a variety of environments, and Suitable for large scale analysis. Published techniques for PBP analysis vary in recommendations for: collection, extraction, disruption mode, and analysis; evidence suggests the variation in results may depend at least in part on the species and even strain(s) of interest. Experiments that tested variations in these parameters have drawn very different conclusions regarding extraction efficiency and reproducibility. Cyanobacteria are more difficult to extract than other PBP-containing algae such as cryptophytes, but can be important primary producers. We used a cryptophyte (Rhodomonas salina) and cyanobacterium (Synechococcus sp.) to compare extraction efficiencies of water samples concentrated via centrifugation to filtered samples using two different extraction buffers (phosphate and asolectin-CHAPS). Samples were analyzed on a fluorometer configured for PC and PE detection. The results have important implications for collection and storage of samples for routine analysis; some previous studies (although not all) have suggested that filtered samples have a much lower extraction efficiency than whole water samples.

Kenemer, Christopher↗

A Vacuum-Compatible, Spectrally Tunable, Flat Panel Uniform Source for Testing Large Aperture Earth Observation Systems

Labsphere, Inc. in conjunction with NASA GSFC and Genesis Engineering Solutions Inc., has developed an innovative, vacuum compatible, calibration spectro-radiometric illumination source with a highly uniform large-area rectangular flat panel active area. This device features a uniquely shaped diffuse integration geometry to achieve high uniformity over a large active output area while maintaining a smaller and more robust overall form-factor when compared to previous designs or integrating spheres. A new liquid-cooled hybrid quartz-tungsten (QT) and light emitting diode (LED) source module has been engineered to provide direct-in-vacuum reference illumination over the full dynamic range and spectrum of the VIIRS instrument’s optical bands during pre-launch testing. The first unit has been demonstrated to meet its requirements using ambient technology and a fully-vacuum-compatible second unit is planned to allow testing in thermal vacuum (TVAC) campaigns. This technology is flexible and capable of meeting the needs of many other instruments/missions requiring this type of test/calibration capability.

Jeffrey Holt↗

Module/array interface study

Several aspects of module design are evaluated, including glass superstrate and metal substrate module configurations, the potential for hail damage, light absorption in glass superstrates, the economics of glass selection, and electrical design. Also, three alternate glass superstrate module configurations are evaluated by means of finite element computer analyses. Two panel sizes, 1.2 by 2.4 m (4 by 8 ft) and 2.4 by 4.8 m are used to support three module sizes, 0.6 by 1.2 m, 1.2 by 1.2 m, and 1.2 by 2.4 m, for design loadings of + or - 1.7 kPa, + or - 2.4 kPa, and + or - 3.6 kPa. Designs and cost estimates are presented for twenty panel types and nine array configurations at each of the three design loadings. Structural cost sensitivities of combined array configurations and panel cases are presented.

Source record↗

Long-length Scintillating Fibers for Nuclear Waste Repositories (Conference Record)

This paper describes the fabrication, testing, and characterization of long-length, up to 50 m, scintillating fibers for the purpose of radiation monitoring in inaccessible radiological and nuclear waste repositories. The fabrication aspect was focused on ruggedizing the 1-mm diameter fiber and limiting external light interference for fibers. Testing and characterization were performed in a laboratory setting with radiation sources, a photosensor module and a multi-channel analyzer. Light attenuation was studied as a function of distance by analyzing both the spectrum and count rate. Additionally, the scintillating fibers were coupled to optical communication fibers (100 m) to extend the reach of the system. This paper also includes the optical spectrometry results from the sensitivity and response of the signal attenuation. Lastly, the paper covers the field testing of the scintillating fibers in a relevant environment.

47 - OTHER INSTRUMENTATION↗

Diverse Long-Term Variability of Five Candidate High-Mass X-Ray Binaries from Swift Burst Alert Telescope Observations

We present an investigation of long-term modulation in the X-ray light curves of five little-studied candidate high-mass X-ray binaries using the Swift Burst Alert Telescope (SWIFT-BAT). IGR J14488-5942 and AX J1700.2-4220 show strong modulation at periods of 49.6 and 44 days, respectively, which are interpreted as orbital periods of Be star systems. For IGR J14488-5942, observations with the Swift X-ray Telescope show a hint of pulsations at 33.4 seconds. For AX J1700.2-4220, 54 second-pulsations were previously found with XMM-Newton. Swift J1816.7-1613 exhibits complicated behavior. The strongest peak in the power spectrum is at a period near 150 days, but this conflicts with a determination of a period of 118.5 days by La Parola et al. AX J1820.5-1434 has been proposed to exhibit modulation near 54 days, but the extended BAT observations suggest modulation at slightly longer than double this at approximately 111 days. There appears to be a long-term change in the shape of the modulation near 111 days, which may explain the apparent discrepancy. The X-ray pulsar XTE J1906+090,which was previously proposed to be a Be star system with an orbital period of approximately 30 days from pulse timing, shows peaks in the power spectrum at 81 and 173 days. The origins of these periods are unclear, although theymight be the orbital period and a superorbital period respectively. For all five sources, the long-term variability, together with the combination of orbital and proposed pulse periods, suggests that the sources contain Be starmass donors.

Corbet, Robin H. D.↗

Interference effects in the formation of the light bullet spectrum under axicon focusing

Specific features of the anti-Stokes band of the light bullet supercontinuum spectrum under filamentation of 1900-nm femtosecond pulses, focused by an axicon in fused silica and calcium fluoride, have been experimentally, numerically, and analytically investigated. It is found that the formation of two or more light bullets in a filament leads to modulation of spectral components’ intensity. The oscillation period of spectral components, defined as the wavelength interval between adjacent intensity minima, decreases with decreasing their wavelength. On a logarithmic scale, the relative change in the oscillation period in the spectrum is proportional to the spectral component wavelength and is independent of the pulse energy and the position of the light bullet formation region in the filament. It is established that the modulation in the spectrum is due to the interference of the broadband supercontinuum emitted by light bullets, and its period decreases with increasing interval between them. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced Solid State Lighting for AES Deep Space Hab Project

The advanced Solid State Lighting (SSL) assemblies augmented 2nd generation modules under development for the Advanced Exploration Systems Deep Space Habitat in using color therapy to synchronize crew circadian rhythms. Current RGB LED technology does not produce sufficient brightness to adequately address general lighting in addition to color therapy. The intent is to address both through a mix of white and RGB LEDs designing for fully addressable alertness/relaxation levels as well as more dramatic circadian shifts.

Technology Portfolio System↗

RRab variables with identical light-curve shapes at different pulsation periods

In this paper, we report on the detection of RRab stars with quasi-identical-shape light curves but period differences as large as 0.05–0.21 d using the Galactic bulge data of the OGLE-IV survey. We have examined stars with shorter periods than the Oosterhoff I ridge of the bulge. These stars generally have smaller amplitudes and larger Fourier phase-differences than the typical bulge RRab stars have at the same period. Many of these ‘anomalous’ stars have good-quality light curves without any sign of the Blazhko modulation. Examining their Fourier parameters revealed that several of these stars show very similar light curve to the typical bulge RR Lyrae. We found hundreds of quasi-identical-shape light-curve pairs with different periods between the ‘anomalous’- and the ‘normal’-position RRab stars based on the OGLE I-band data. The OGLE V-band, and the archive VVV and MACHO surveys K s -, b- and r -band data of these stars were also checked for light-curve-shape similarity. Finally, 149 pairs with identical-shape light curves in each available photometric band were identified. Calculating the physical properties of the variables using empirical formulae, on average, −0.5 dex, −0.13 mag, 0.67, and 165 K differences between the [Fe/H], M V , R/R ⊙ , and T eff values of the members of the pairs are derived, being the short-period stars less metal-poor, fainter, smaller, and hotter than the long-period variables. To explain the existence of variables with different physical properties and pulsation periods but with identical-shape light curves is a challenging task for modelling.

79 ASTRONOMY AND ASTROPHYSICS↗

LETID in Legacy and Modern PV Modules: Accelerated Testing and Field Deployment

The kinetics of light- and elevated temperature-induced degradation (LETID) in silicon solar cells depend on the precise operating excess carrier density (?n) of the device. This dependency causes differences in the way LETID manifests in modern, higher-efficiency devices compared to lower-efficiency, legacy devices that might have been deployed in the field in previous years. In this work we model how different vintages of devices are expected to behave in both accelerated laboratory testing, as well as field deployment. The differing excess carrier densities encountered in various module vintages has implications both for interpreting accelerated test data, as well as identifying, diagnosing, and potentially treating LETID in the field.

excess carrier density↗

Modulating metal-centered dimerization of a lanthanide chaperone protein for separation of light lanthanides

Elucidating details of biology’s selective uptake and trafficking of rare earth elements, particularly the lanthanides, has the potential to inspire sustainable biomolecular separations of these essential metals for myriad modern technologies. Here, we biochemically and structurally characterize Methylobacterium (Methylorubrum) extorquens LanD, a periplasmic protein from a bacterial gene cluster for lanthanide uptake. This protein provides only four ligands at its surface-exposed lanthanide-binding site, allowing for metal-centered protein dimerization that favors the largest lanthanide, La III . However, the monomer prefers Nd III and Sm III , which are disfavored lanthanides for cellular utilization. Structure-guided mutagenesis of a metal-ligand and an outer-sphere residue weakens metal binding to the LanD monomer and enhances dimerization for Pr III and Nd III by 100-fold. Selective dimerization enriches high-value Pr III and Nd III relative to low-value La III and Ce III in an all-aqueous process, achieving higher separation factors than lanmodulins and comparable or better separation factors than common industrial extractants. Finally, we show that LanD interacts with lanmodulin (LanM), a previously characterized periplasmic protein that shares LanD’s preference for Nd III and Sm III . Our results suggest that LanD’s unusual metal-binding site transfers less-desirable lanthanides to LanM to siphon them away from the pathway for cytosolic import. The properties of LanD show how relatively weak chelators can achieve high selectivity, and they form the basis for the design of protein dimers for separation of adjacent lanthanide pairs and other metal ions.

lanthanide biochemistry↗

Dark matter detection capabilities of a large multipurpose Liquid Argon Time Projection Chamber

Liquid Argon Time Projection Chambers are planned to comprise a central role in the future of the U.S. High Energy Physics neutrino program. In particular, this detector technology will form the basis for the 40 kton Deep Underground Neutrino Experiment (DUNE) . Here in this paper we take as a starting point the dual phase far detector design proposed by the DUNE experiment and ask what changes are necessary to allow one of the four 10 kt modules to be sensitive to heavy Weakly Interacting Massive Particle (WIMP) dark matter. We show that with control over backgrounds and the use of low radioactivity argon, which may be commercially available on that timescale, along with a significant increase in light detection, one DUNE-like module gives a competitive WIMP detection sensitivity, particularly above a dark matter mass of 100 GeV.

47 OTHER INSTRUMENTATION↗

Indoor and Outdoor Test Results for 'DUSST', a Low-Cost, Low-Maintenance PV Soiling Sensor

Soiling can cause significant losses to photovoltaic systems, and therefore it is often measured for the purposes of predicting long-term energy forecasts or for monitoring real time performance and triggering maintenance events as needed. Currently, the most common soiling monitoring technologies are soiling stations that use the electrical outputs of a regularly cleaned PV device and of a naturally soiled PV device to quantify soiling. As part of a new class of low-cost and low-maintenance soiling stations NREL has previously presented 'DUSST'. DUSST projects a collimated monochromatic light source through a glass surface (exposed similarly to the PV modules that need to be monitored) and on to a light detector to measure the intensity of the transmitted light. As the glass surface naturally soils, the losses are quantified by comparing this soiled reading with a calibrated reading under baseline clean condition. This work presents the ongoing improvement of DUSST and the ongoing indoor and outdoor validation of this new soiling sensor.

14 SOLAR ENERGY↗