Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laboratories”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Leveraging national laboratories to increase Black representation in STEM: recommendations within the Department of Energy

Increasing diversity in STEM disciplines has been a goal at scientific institutions for many decades. Black representation in STEM, however, has remained critically low at all levels (high school, undergraduate, graduate, and professional) for over 40 years, highlighting the need for innovative strategies that promote and retain Black students and professionals in STEM. We refocus efforts on increasing Black representation in STEM by promoting early exposure and continued engagement while leveraging national laboratories—an underutilized resource with immense potential to centralize diversity and inclusion efforts nationally.

99 GENERAL AND MISCELLANEOUS↗

Progress on Pu-238 production at Idaho National Laboratory from February 2022 to July 2023

Idaho National Laboratory (INL) has continued to qualify irradiation positions in the Advanced Test Reactor (ATR) for Pu-238 production to support NASA deep space missions. Over the past year, INL qualified Np-237 targets for ATR’s North East Flux Trap (NEFT), Inner-A and H positions. Work has begun to requalify the South Flux Trap (SFT) and to qualify the East Flux Trap (EFT) for the ATR GEN I target and is midway through the qualification process. This paper gives an overview of operational and technical activities from February 2022 to July 2023.

07 ISOTOPE AND RADIATION SOURCES↗

Data Projection of the High Temperature Electrolysis System in the Dynamic Energy Transport and Integration Laboratory using Dynamic System Scaling

For nuclear power to be flexible in a functioning Integrated Energy System (IES), excess produced heat must be stored or utilized during times of low power demand to ensure a load factor of 1 while load balancing. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is one facility that is under development to emulate IES conditions on the engineering-scale, planned to conduct virtual real time operations with industry-scale facilities, and is currently testing thermal storage and high temperature electrolysis. As part of the study to develop a method to preprocess input signals or postprocess output signals between systems of different scales via Dynamical System Scaling (DSS), the current research is one of the continued efforts branching from the data projection activity conducted for the Thermal Energy Distribution System and currently engages the High Temperature Electrolysis (HTE) System in DETAIL. The HTE SOEC electrical, fluid, and thermal dynamics Figure of Merits (FOM) were identified, governing equations and closure relations were successfully scaled, and relations between FOM scaling ratios were determined. Setting the scaling objectives to reform existing data to project a data set that doubly accelerated the electrolysis process while preserving the produced amount of hydrogen was generated for the full transient. The calculated boundary conditions were inlet temperature, stack current, and inlet steam mass flow rate at 1470 K, 121.1 A, and 1.886 g/s, respectively. The research outcomes demonstrated an output signal postprocessing case accelerating the hydrogen production without changing geometry, number of cells, and partial pressures.

08 HYDROGEN↗

Evaluation of Oak Ridge National Laboratory Health Physics Research Reactor Operation Data for Critical Benchmark Creation

The Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR) was a research reactor designed and built at ORNL in 1961. The critical assembly used a highly enriched uranium and molybdenum alloy as the fuel and could be operated in steady-state or burst modes. The HPRR has recently been the object of an investigation to create a criticality benchmark. Such benchmarks are very important, as they are used primarily to show the accuracy of newly developed modeling codes and to help experimental validation and reactor licensing. The evaluated experiments considered in this paper were carried out between 1974 and 1986 from various HPRR activities such as steady-state subcritical, steady-state critical, and burst prompt super-critical operations of the reactor for dosimetry, irradiation, or training purposes. By using the HPRR experimental logbook information and the as-built drawings of the critical assembly, a highly detailed model of the HPRR was created with SCALE 6.2.4/KENO-VI, and a first version of a critical benchmark of the HPRR was developed following the International Criticality Safety Benchmark Evaluation Project (ICSBEP) guidelines for thorough description and uncertainty/sensitivity quantification. Unfortunately, in most of the evaluated experiments, the obtained difference between calculated and experimental k eff is around 1,000 pcm, corresponding to a relative error of approximately 1%, beyond the quality standards of the ICSBEP recommending a relative error below 0.1%. Moreover, the derived experimental uncertainty is high, around 4% relative, mainly due to the U-Mo fuel density uncertainty, but also from numerous other factors. For these reasons, the creation of a valuable critical benchmark from HPRR operation data is thus far compromised. In this paper, the different steps of the experiments’ evaluation are summarized, and the reasons for the experimental/calculation discrepancies and potential ways to solve them are explored. This paper also aims to remind us always to exercise considerable care when performing experimental work, and to record all the data possible for potential future uses.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Current Progress of the Final Design of a Subcritical Assembly at the Oak Ridge National Laboratory

During the past decade, the US Department of Energy (DOE)/National Nuclear Security Administration (NNSA) Nuclear Criticality Safety Program (NCSP) has been coordinating nuclear criticality safety (NCS) courses to provide training and qualification to new staff, supervisors, managers, regulators, and other professionals involved with NCS. To address the growing need for more NCS training possibilities, a subcritical assembly was designed at Oak Ridge National Laboratory (ORNL). The Oak Ridge Subcritical Assembly (ORSA), operated at ORNL, could be used in a new course for fissile material handlers/operators or as a backup training facility for currently existing NCSP hands-on NCS training. This paper describes some of the design steps necessary for obtaining a final ORSA design, beginning with a successful feasibility study performed in 2020. Numerous parameters within each main element of the assembly were considered, such as the reflector used, the type of fuel coating or plating used, and the number of fuel plates used. The design choices related to each parametric study described in this paper are detailed and justified at the end of each subsection. An overview of the current final design characteristics of ORSA and the experiments’ possibilities is also provided. ORSA will be built with fuel plates from legacy Aerojet General Nucleonics (AGN)-201M research reactors currently stored at the Y-12 National Security Complex (Y-12). The cylindrical fuel plates comprise UO 2 particles embedded in polyethylene and have a nominal enrichment of 19.5 ± 0.5 wt % 235 U. The basis for the final design was the feasibility study from 2020. In the feasibility study, ORSA achieved k eff = 0.95, corresponding to a multiplication factor of 20, with approximately 620 g of 235 U (four 4 cm plates, three 2 cm plates, and two 1 cm plates) and an 8.5 cm thick graphite reflector radially and on top of the assembly. The bottom of the assembly has a graphite thickness of 5 cm, and the chosen graphite density was 2.3 g/cm 3 . All design calculations were performed using SCALE 6.2.4 KENO-VI and with the ENDF/B VII.1 Continuous Energy cross-section library.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Overview and Current Status of Neutron Imaging at Oak Ridge National Laboratory

Neutron imaging is a non-destructive technique used to study the internal structure and composition of a wide range of materials. At Oak Ridge National Laboratory (ORNL), there are two neutron imaging beamlines that provide complementary capabilities that serve a diverse community, from materials science and engineering to biomedical and plant sciences. This report provides an overview of the current ORNL imaging capabilities that support materials research for a broad user community.

Torres, James [ORNL] (ORCID:0000000289407610)↗

Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?

Variation in the electrical conductivity (EC) of water can reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. Broader application of open source (OS) EC sensors could provide an inexpensive method to measure water quality. While studies show that other water quality parameters can be robustly measured with sensors, a similar effort is needed to evaluate the performance of OS EC sensors. To address this need, we evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. We found a significant difference between OS sensor mean accuracy (3.08%) and all other sensors combined (9.23%). Our study also found that EC sensor precision decreased across all sensor configurations with increasing calibration standard EC. There was also a significant difference between OS sensor mean precision (2.85 μS/cm) and the mean precision of all other sensors combined (9.12 μS/cm). Cable length did not affect OS sensor precision. Furthermore, our results suggest that future research should include evaluating how performance is impacted by combining OS sensors with commercial data loggers as this study found significantly decreased performance in OS/commercial-hybrid sensor configurations. To increase confidence in the reliability of OS sensor data, more studies such as ours are needed to further quantify OS sensor performance in terms of accuracy and precision across different settings and OS sensor and data collection platform configurations.

54 ENVIRONMENTAL SCIENCES↗

Differential laboratory passaging of SARS-CoV-2 viral stocks impacts the in vitro assessment of neutralizing antibodies

Viral populations in natural infections can have a high degree of sequence diversity, which can directly impact immune escape. However, antibody potency is often tested in vitro with a relatively clonal viral populations, such as laboratory virus or pseudotyped virus stocks, which may not accurately represent the genetic diversity of circulating viral genotypes. This can affect the validity of viral phenotype assays, such as antibody neutralization assays. To address this issue, we tested whether recombinant virus carrying SARS-CoV-2 spike (VSV-SARS-CoV-2-S) stocks could be made more genetically diverse by passage, and if a stock passaged under selective pressure was more capable of escaping monoclonal antibody (mAb) neutralization than unpassaged stock or than viral stock passaged without selective pressures. We passaged VSV-SARS-CoV-2-S four times concurrently in three cell lines and then six times with or without polyclonal antiserum selection pressure. All three of the monoclonal antibodies tested neutralized the viral population present in the unpassaged stock. The viral inoculum derived from serial passage without antiserum selection pressure was neutralized by two of the three mAbs. However, the viral inoculum derived from serial passage under antiserum selection pressure escaped neutralization by all three mAbs. Deep sequencing revealed the rapid acquisition of multiple mutations associated with antibody escape in the VSV-SARS-CoV-2-S that had been passaged in the presence of antiserum, including key mutations present in currently circulating Omicron subvariants. These data indicate that viral stock that was generated under polyclonal antiserum selection pressure better reflects the natural environment of the circulating virus and may yield more biologically relevant outcomes in phenotypic assays. Thus, mAb assessment assays that utilize a more genetically diverse, biologically relevant, virus stock may yield data that are relevant for prediction of mAb efficacy and for enhancing biosurveillance.

60 APPLIED LIFE SCIENCES↗

Laboratory Drilling Test Data of PDC bits with Sierra White Granite Rock

This file contains unprocessed drilling data tests on Sierra White Granite (SWG) using two new PDC bits. The tests were conducted at Sandia National Laboratories (SNL) in the Hard Rock Drilling Facility (HRDF). The collected data includes ROP data at rotational speeds of 80, 120, and 160 RPMs, with incremental weight on bit (WOB) up to 5100 lbs. The diameter of the 4-bladed and 5-bladed PDC bits was 3 3/4" and supplied by National Oilwell Varco (NOV). Five tests modes were conducted for both bits, which are as follow: (1) Rigid configuration, with no vibration compliance (2) Flywheel configuration (3) Torsional compliance configuration (4) Axial Compliance configuration (5) Combined Axial and Torsional compliance configuration Note: the WOB and torque in the drilling data should be calibrated by zeroing the WOB and torque when the drill bit tags the rock sample.

15 GEOTHERMAL ENERGY↗

Utah FORGE Friction-Permeability-Seismicity Laboratory Experiments with Non-Linear Acoustics

Laboratory experimental data on saw-cut interface of Westerly Granite and Utah Forge granitoid rocks. Experiments include velocity-stepping and fluid pressure stepping experiments. Mechanical data from 3 ISCO pumps connected to a Temco pressure vessel measure axial, confining and fault: fluid pressure (kPa), fluid flow rate (mL/min) and volume remaining in pump (mL). Non-linear acoustic data acquired via Verasonics systems connected to PZTs inside the pressure vessel give the timeshift, amplitude and RMS amplitude of the passing P-wave.

15 GEOTHERMAL ENERGY↗

Laboratory Experiments Examining the Effect of Thermal and Mechanical Processes on Hydraulic Transmissivity Evolution

Using laboratory slide-hold-slide experiments, at temperatures from 22 to 200 degrees C, to examine effects of fracture reactivation and quasi-static loading on the evolution of fluid transport properties of simulated fractures in Westerly granite. At all temperatures, the in-plane hydraulic transmissivity consistently decays during hold periods resulting in an overall reduction in transmissivity. During the first three to fifteen hours of an experiment, transmissivity decreases rapidly due to the generation of wear products, development of a sliding surface, and compaction of the resulting gouge. Once the sliding surface has developed, the long-term transmissivity decay rate at 22 and 100 degrees C is significantly lower than the transmissivity decay rate during the initial 3-15 hours of the experiment. However, at 200 degrees C, the decay of hydraulic transmissivity remains high throughout the experiment. The long-term decay of hydraulic transmissivity can be fitted with a power law model with more rapid reduction of hydraulic transmissivity at higher temperature. Periods of sliding on the fracture surface result in transient increases in the transmissivity, due to shear dilation, as is expected for Coulomb materials. These transients are superimposed on the long-term decay. When sliding ceases and a new hold period commences, there is a rapid reduction in transmissivity and return to the long-term rate of transmissivity decay. The rate of decay of the transmissivity transients is inversely correlated with temperature, in contrast to the long-term decay and the expected behavior for processes like subcritical crack growth and indentation creep. The higher decay rates that are observed during the initial 3-15 hours of the tests and following sliding, are associated with times that the porosity of the gouge is expected to be high. The difference in decay rates suggests that when the gouge is driven far from equilibrium by active shearing, densification may be dominated by a different mechanism from long-term compaction.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Fault Reactivation Through Fluid Injection Induced Seismicity Laboratory Experiments

Included are results from shear reactivation experiments on laboratory faults pre-loaded close to failure and reactivated by the injection of fluid into the fault. The sample comprises a single-inclined-fracture (SIF) transecting a cylindrical sample of Westerly granite. All experiments are conducted at ambient temperature and follow a similar protocol: (i) application of confining stresses (3MPa) on the fault fully saturated with DI water, (ii) shear-mobilization through the increase of axial loading at a constant displacement rate until a post-peak steady-state condition is reached, (iii) reduction of axial loading and related shear stress to a prescribed fraction of the peak steady-state frictional strength (typically 60% to 90%, representing intermediate to high magnitudes) and (iv), fault reactivation triggered by a stepwise increase of pore pressure on the fault in 0.1 MPa increments held constant for 1-5 minutes. Mechanical data from three ISCO pumps connected to a Temco pressure vessel measure axial, confining, and fault-related parameters, including fluid pressure (kPa), fluid flow rate (mL/min), and axial displacement (mm). See included code for initial data analysis and visualization for select experiments. Resource names represent experiment numbers found in the "Read Me" file, which describes each experimental setup and parameters.

15 GEOTHERMAL ENERGY↗

HERO WEC V1 Upgrade - 2023 Laboratory Testing (Raw Data)

This submission contains the original, unprocessed data from the 2023 Large Amplitude Motion Platform (LAMP) testing of NREL's Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC). This data serves as a companion to MHKDR #520. Data was collected using NREL's Modular Ocean Data AcQuisition (MODAQ) system in TDMS format. Specifications of TDMS files can be found on the NI website. The TDMS files have been separated into zip files corresponding to either Drivetrain, Hydraulic, or Electric configuration runs representing the respective test cases that were run. The drivetrain runs were used to characterize the drivetrain only (no pump or generator). The Hydraulic runs represent the configuration when the seawater pump is installed, and the Electric runs represents the configuration when the generator is installed. The following sub-categories of data are included for each type: - DW - Deep water (monochromatic sine wave) profile (not run in drivetrain configuration) - Heave - Heave only (monochromatic sine wave) profile - Heave_NoRO (hydraulic configuration only) - Heave_ACC (hydraulic configuration only) - IR - Surge and heave irregular wave profile (not run in drivetrain configuration) - RW - Heave only profile created from real world encoder data (not run in drivetrain configuration) Reference documents: - "HERO WEC Lamp Test Run Log.xlsx": contains specifications for each test run - "Lamp Data Description.docx": provides detailed information about data types and processing methods For those interested in the processed data the authors have created a separate submission, MHKDR #520, linked below. This data set has been developed by the National Renewable Energy Laboratory, operated by Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

High-Mileage Courier Fleet Vehicle Laboratory Battery Pack Testing

For one of each of the AVTA's plug-in hybrid electric vehicles, battery electric vehicles, and some hybrid electric vehicles tested in high-mileage courier fleets, the high-voltage traction battery packs were removed from the vehicle and tested at the beginning and end of fleet testing. For some vehicles, batteries also were tested at periodic intervals during fleet testing. Standard reference performance tests were conducted to characterize battery degradation over time. This dataset contains results from two or more rounds of battery tests for 21 distinct year/make/model vehicles (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Each round of battery testing included the "Static Capacity Test" and the "Hybrid Pulse Power Characterization (HPPC) Test", conducted according to test procedures published in the United States Advanced Battery Consortium ["Battery Test Manual For Power-Assist Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=57), ["Battery Test Manual For Plug-In Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=168), and ["Electric Vehicle Battery Test Procedures Manual"](https://www.uscar.org/commands/files_download.php?files_id=5) prior to the time of testing. These tests were performed by Intertek Testing Services, North America. (This dataset will be shared by API; a small sample of the vehicle battery and test data has been extracted and is available for download while the API is being developed.)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surface soil temperature and water content from warming experiment located at the Rocky Mountain Biological Laboratory, Colorado, 2015 to 2019

This data package consists of soil temperature and soil water content sensor data from the warming experiment near the Rocky Mountain Biological Laboratory. Data range is from summer 2015 to summer 2019, when the warming manipulation was terminated. The location of the warming experiment is in the upper montane life zone and consists of meadow vegetation with a mixture of sagebrush (Artemisia tridentata), forb species (Erigeron speciosus, Helianthella quinquenervis, Lathyrus lanszwertii), and graminoid species (Festuca thurberi, Carex spps). Early studies showed that the heating treatment led to earlier snowmelt as well as warmer and drier surface soils, and changes in the functional composition of aboveground biomass favoring sagebrush over forb species (Harte and Shaw, 1995). These changes were mainly observed in the upper, naturally drier zone for the experimental plots. More recent observations of aboveground biomass, soil carbon, and microbial composition require concurrent information about the abiotic environment for interpretation and extrapolation to process-based models. This data package provides the plot- and zone-level abiotic context for the final years of the experiment and consists of csv files with hourly soil temperature (WM_ST.csv) and soil water content (WM_SWC.csv).

54 ENVIRONMENTAL SCIENCES↗

CROCUS Air Quality Data at Argonne National Laboratory Prairie Site

The AQT (Vaisala AQT530) instrument provides observations on meteorological conditions, including particulate matter (PM2.5, PM10), gas species concentrations (NO, NO2, O3, CO), and environment temperature and moisture. These measurements are critical for understanding air quality. These measurements are useful for understanding changes in aerosol properties, air quality research, and comparing to model experiments especially in urban environments. These measurements are collected at the Argonne Testbed for Multiscale Observational Science (ATMOS), a prairie field site at Argonne National Laboratory in Lemont, Illinois. Data is available in the netCDF data format, we encourage data users review documentation through Project Pythia to understand how to work with netCDF data https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html. Each file contains one day's worth of data (24 hours, starting at 0000 UTC). The data is aggregated into daily frequency to make it easier to process multiple days, and compress the higher-resolution fields. File naming convention includes the project (CROCUS), location (atmos), data level (raw, a1), date (year, month, day), and hour (0000).

54 ENVIRONMENTAL SCIENCES↗

CROCUS Weather Data at Argonne National Laboratory Prairie Site

Vaisala WXT sensor is an all-in-one weather instrument that provides 6 of the most important weather parameters: barometric pressure, temperature, relative humidity, rainfall, wind speed and direction. Temperature, pressure, relative humidity, and rainfall are sampled at 1 second frequency, while wind speed/direction is measured at ten per second (10Hz) frequency. These measurements are useful for looking at characterizing local weather, identifying unique weather events, and studying local turbulence, especially given the high temporal resolution of the wind measurements. These measurements are collected at the Argonne Testbed for Multiscale Observational Science (ATMOS), a prairie field site at Argonne National Laboratory in Lemont, Illinois. Data is available in the netCDF data format, we encourage data users review documentation through Project Pythia to understand how to work with netCDF data https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html. The data is aggregated into daily frequency to make it easier to process multiple days, and compress the higher-resolution fields. Each file contains one day's worth of data (24 hours, starting at 0000 UTC). File naming convention includes the project (CROCUS), location (atmos), data level (raw, a1), date (year, month, day), and hour (0000).

54 ENVIRONMENTAL SCIENCES↗

AmeriFlux US-Fo1 Flux Observations of Carbon from an Airborne Laboratory (FOCAL) Campaign Site 1

This is the AmeriFlux version of the carbon flux data for the site US-Fo1 Flux Observations of Carbon from an Airborne Laboratory (FOCAL) Campaign Site 1. Site Description - This tower is locate south of Prudhoe Bay off the Dalton Highway along the Sagavanirktok (Sag) River. Landcover at the site is wetsedge (based on NSSI land cover map). During the first campaign (2013-2014), the tower location was 70.085450N; -148.570160W. It was moved to the current location (70.085050N, 148.567090W) during 2022 to 2024.

Krishnan, Praveena [NOAA/ARL/ATDD]↗