Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Acoustic, performance, and wake survey measurements of a lobed velocity-decayer nozzle installed on a quieted TF-34 turbofan engine

Results for three velocity decayer nozzle configurations are compared with those obtained with a separate flow coannular nozzle tested on the same quieted turbofan engine. Peak sideline noise, which occurred 110 degrees from the inlet, was 2 to 4 db louder than with the coannular nozzle at the same ideal effective exhaust velocity and 8 to 11 db louder at the same thrust level. The decayer nozzles produced an increase in loss equivalent to about 4 percent of the engine thrust and also increased the effective exhaust velocity of the engine. The exhaust decayed to 0.35 of its peak velocity, compared with no decay for the coannular nozzle, within 3 equivalent nozzle diameters of the exit. The peak exhaust gas temperature was 400 K lower for the decayer configuration at the same location. The increase in perceived noise level for the decayer nozzles as compared with the coannular nozzle was attributed to the increase in exhaust velocity and the shift in peak spectrum frequency produced by these nozzles.

Samanich, N. E.↗

Thermocouple installation

A thermocouple assembly which includes a plug having a pair of small diameter holes near one end thereof which are spaced a small distance apart to leave a thin quantity of plug material between the holes is presented. There are a pair of thermocouple wires extending through the different holes and with the outer ends of the wires joined to the thin quantity of plug material which lies between the holes to form a thermocouple junction.

Powell, W. B.↗

Investigation of effect of propulsion system installation and operation on aerodynamics of an airbreathing hypersonic airplane at Mach 0.3 to 1.2

Results from an investigation of the effects of the operation of a combined turbojet/scramjet propulsion system on the longitudinal aerodynamic characteristics of a 1/60-scale hypersonic airbreathing launch vehicle configuration are presented. Decomposition products of hydrogen peroxide were used for simulation of the propulsion system exhaust.

Cubbage, J. M.↗

Risk management of liquefied natural gas installations

In connection with the construction of four major liquefied natural gas (LNG) facilities in New York City, the New York City Fire Commissioner has asked NASA for assistance. It was decided that the Kennedy Space Center should develop a risk management system (RMS) for the use of the New York Fire Department (NYFD). The RMS provides for a published set of safety regulations by the NYFD. A description of the RMS is presented as an example of an application of aerospace technology to a civilian sector, namely LNG facilities.

Fedor, O. H.↗

Acoustic performance of inlet multiple-pure-tone suppressors installed on NASA Quiet Engine 'C'

The purpose of the experimental program reported herein was to define the length of multiple pure tone (MPT) treatment required to reasonably suppress the MPT's produced by a supersonic tip speed fan and also determine what other suppression, broadband, and blade passing frequency (BPF), might be accomplished. The experimental results are presented in terms of both far-field and duct acoustic data. Front quadrant sound power level reduction in the far field is shown to agree with duct measurements over the range of treatment lengths. Detailed one-third octave and narrow band spectra at the maximum forward noise angle are presented. Some detailed analyses of one-third-octave band amplitudes are shown as a function of far-field angle. An approximate spinning mode duct propagation analysis is then introduced which predicts the acoustic suppression by the treatment on the multiple pure tones.

Bloomer, H. E.↗

Installing fiber insulation in tight spaces

Two techniques using organic resin binders or thin clear-burning plastic film have been successfully used to simplify, and facilitate handling of aluminum/zirconia fiber batting as insulation material for high temperature seals.

Patel, B. C.↗

Easily installed insulation for steamfittings

Insulating blanket trimmed by hook-and-loop fasteners adds safety and prevents heat loss. For maintenance or adjustments, borders are quickly unfastened and fabric slipped off.

Owens, G.↗

Installation package for concentrating solar collector panels

The concentrating solar collector panels comprise a complete package array consisting of collector panels using modified Fresnel prismatic lenses for a 10 to 1 concentrating ratio, supporting framework, fluid manifolding and tracking drive system, and unassembled components for field erection.

Source record↗

Installation package for Sunpak solar collectors

A subsystem (air/liquid vacuum collector) was developed for use with solar combined heating and cooling subsystems. The collector is modular in design, is approximately twelve-feet-three-inches wide and is eight-feet-seven-inches high. The module contains 72 collector tube elements and weighs approximately 300 pounds.

Source record↗

A passive thermosyphon heat exchanger for residential solar installations

The paper details the development of a thermosyphon water-to-air heat exchanger for residential solar applications. Modeling techniques used in the analysis of thermosyphon performance are included, as well as test results from laboratory-scale experiments. In addition, a description of the initial full-scale prototype is presented, along with experimental test results. Present areas of development are discussed, with an economic comparison of thermosyphon and forced convection heating systems also being included.

Franklin, J. L.↗

Fastener for easy installation and removal of tiles

Mating strips, one with metal hooks and one with metal loops, allow convenient mounting and removal on many kinds of modules. Principle is adaptable to applications where shear-resistant, compliants, removable fastening is needed in hard-to-reach places, especially when attached part is lightly loaded or fragile.

Maletz, L. H.↗

Solar heating, cooling, and hot water systems installed at Richland, Washington

The project described is part of the U. S. Department of Energy's solar demonstration program, and became operational in April 1978. The solar system uses 6,000 square feet of flat-plate liquid collectors in a closed loop to deliver solar energy through a liquid-liquid heat exchanger to the building heat-pump duct work or 9,000-gallon thermal energy storage tank. A 25-ton Arkla solar-driven absorption chiller provides the cooling, in conjunction with a 2,000 gallon chilled water storage tank and reflective ponds on three sides of the building surplus heat. A near-by building is essentially identical except for having conventional heat-pump heating and cooling, and can serve as an experimental control. An on-going public relations program was provided from the beginning of the program, and resulted in numerous visitors and tour groups.

Source record↗

Design fabrication and installation of a yaw measuring device

The results of work performed in the development and testing of a yaw measuring device are summarized. A review of the yaw measurement method; and the techniques and hardware needed for its implementation are presented. A description and summary of the tests performed at the U.S. Bureau of Mines Bruceton facility are included. Conclusions are summarized and recommendations for a unit capable of operation in a mine environment are presented.

Source record↗

Motel solar hot-water installation--Atlanta, Georgia

Analysis of hardness of local water, average insolation for site, and daily hot water requirements insures suitability of solar-energy system design. Report describes two units which are designed to supply 81 percent of motel's annual hot water demand based on hypothetical 85 percent occupancy. Report includes drawings, operating and maintenance instructions, and test results for 1 day of operation.

Source record↗

Solar energy system installed at the North Georgia APDC office building

A hydronic, automatic drain-down solar heating and cooling system is described. The system provides solar heat exchange from a 2,001 square foot effective collector area and supplies 65-70 percent of the building's cooling demand, 90-95 percent of the heating demand, and domestic hot water. The acceptance test plan and results, system operation and maintenance, and predicted system performance are presented.

Source record↗