Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installation tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Achieving Leak Tightness in New Savannah River Site Saltstone Disposal Units - 17454

Saltstone Disposal Unit (SDU) 6 is a new disposal unit at the Department of Energy's Savannah River Site Saltstone Disposal Facility. The Saltstone Facility is part of the site's overarching waste management and disposal system. It receives the low-level waste stream and will immobilize in grout more than 90 percent of the liquid volume generated during treatment of the site's liquid high level waste. SDU-6 is the first in a series of large disposal units to be constructed on site. Its internal diameter and height are 114 m (375 ft) and 13.1 m (43 ft), respectively. It uses a cylindrical wire-wrapped concrete water tank design (AWWA D110, Type I), and at 121 ML (32 Mgal), it is one of the largest structures of its kind in the country. Because of its size, SDU-6's base slab was placed in ten sections. Earlier placed sections restrained newer adjacent sections, resulting in shrinkage cracking. Visible cracks were repaired with epoxy. However, the SDU basemat leaked at less than an estimated 4 L/min rate during its first full-height hydrostatic test (2015). The project baseline was to install a coating system to chemically protect the concrete from the high-pH, high-sulfate Saltstone solutions. The coating was not installed during the first hydrostatic test, and subsequently, an adhered elastomeric liner system was chosen to provide higher assurance of bridging floor cracks and preventing leakage. A robust process was used to select and install a liner that will not only provide chemical protection but also achieve leak tightness, which was successfully demonstrated in a second hydrostatic test late in 2016. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Program overview: 1991 flight test objectives

The topics are presented in viewgraph form and include the following: the Joint NASA/FAA Airborne Wind Shear Detection and Avoidance Program; the windshear problem; NASA/FAA Wind Shear Program objectives; program elements; Wind Shear Program roadmap; airborne wind shear sensors; 1991 wind shear flight experiments; operative wind shear detection systems; research aircraft sensor installations; and 1991 test results.

Bowles, Roland L.↗

Pyrolysis Oil Stabilization: Hot-Gas Filtration (CRADA Final Report)

The hypothesis that was tested in this task was that separation of char, with its associated mineral matter from pyrolysis vapors before condensation, will lead to improved oil quality and stability with respect to storage and transportation. The metric used to evaluate stability in this case was a 10-fold reduction in the rate of increase of viscosity as determined by ASTM D445 (the accelerated aging test). The primary unit operation that was investigated for this purpose was hot-gas filtration. A custom-built heated candle filter system was fabricated by the Pall Corporation and furnished to NREL for this test campaign. This system consisted of a candle filter element in a containment vessel surrounded by heating elements on the external surface of the vessel. The filter element and housing were interfaced to NREL’s existing 0.5 MTD pyrolysis Process Development Unit (PDU). For these tests the pyrolysis reactor of the PDU was operated in the entrained-flow mode. The HGF test stand was installed on a slipstream from the PDU so that both hot-gas filtered oil and bio-oil that was not hot-gas filtered could be collected for purposes of comparison. Two filter elements from Pall were tested: 1) porous stainless steel (PSS) sintered metal powder; 2) sintered ceramic powder. An extremely sophisticated bio-oil condensation and collection system was designed and fabricated at NREL and interfaced to the filter unit.

09 BIOMASS FUELS↗

ROLM computers in the flight testing of the Fokker F29 aircraft

The design, development, installation, and operation of the test equipment (MRVS) is discussed. The main feature of the MRVS is continuous recording on an instrumentation recorder data of up to 1500 parameters with a total sample rate of up to 10,000 samples per second. In order to compress the evaluation and calibration time period, the following additional requirements were set for two test systems: (1) recording of selected parameters, time tagged on computer compatible tape (CCT); (2) recording of selected high bandwidth signals and ad hoc parameters on analog tape; (3) onboard presentation of calibrated parameter data, in engineering units, in numerical as well as graphical form for: system checkout during pre-, in- and post-flight, and quick look analysis during in-flight; (4) real time presentation on the ground by telemetry for: flight monitoring, takeoff and landing measurements, and noise measurements; and (5) data processing on the ground on the Fokker-NLR computer network.

Manders, P. J.↗

Measurements of flow phenomena induced by suction through perforated and partially plugged surfaces

Efforts were directed towards completing construction of the windtunnel test section, assembling instrumentation, programming the data acquisition and reduction system, adjusting the streamwise pressure gradient of the test section, calibrating the hot-wire anemometer probe, and constructing and testing a smoke generator. The test section was installed in the wind tunnel and is completely operational. The streamwise pressure gradient was adjusted to be nominally zero at a free-stream velocity of 3.05 m/s (10 ft/s). This was accomplished by adjusting the upper wall of the test section to be slightly divergent. The change in static pressure between any two streamwise locations in the test section was less than one percent of the free-stream dynamic pressure. A suitable means was found for accurately calibrating the hot-wire probe which is used to measure boundary-layer velocity profiles and fluctuating velocities.

Wilkinson, S. P.↗

Solar Tower Experiments for Radiometric Calibration and Validation of Infrared Imaging Assets and Analysis Tools for Entry Aero-Heating Measurements

The NASA Engineering and Safety Center sponsored Hypersonic Thermodynamic Infrared Measurements assessment team has a task to perform radiometric calibration and validation of land-based and airborne infrared imaging assets and tools for remote thermographic imaging. The IR assets and tools will be used for thermographic imaging of the Space Shuttle Orbiter during entry aero-heating to provide flight boundary layer transition thermography data that could be utilized for calibration and validation of empirical and theoretical aero-heating tools. A series of tests at the Sandia National Laboratories National Solar Thermal Test Facility were designed for this task where reflected solar radiation from a field of heliostats was used to heat a 4 foot by 4 foot test panel consisting of LI 900 ceramic tiles located on top of the 200 foot tall Solar Tower. The test panel provided an Orbiter-like entry temperature for the purposes of radiometric calibration and validation. The Solar Tower provided an ideal test bed for this series of radiometric calibration and validation tests because it had the potential to rapidly heat the large test panel to spatially uniform and non-uniform elevated temperatures. Also, the unsheltered-open-air environment of the Solar Tower was conducive to obtaining unobstructed radiometric data by land-based and airborne IR imaging assets. Various thermocouples installed on the test panel and an infrared imager located in close proximity to the test panel were used to obtain surface temperature measurements for evaluation and calibration of the radiometric data from the infrared imaging assets. The overall test environment, test article, test approach, and typical test results are discussed.

Splinter, Scott C.↗

Out-of-Pile Testing of Radiation Hard Optical Fibers

The work detailed in this report was supported under the In-Pile Instrumentation program for FY19. The work was conducted by researchers at Boise State University (BSU) and Idaho National Laboratory (INL). This report describes the out-of-pile testing that has been conducted to help guide sensor design and data interpretation by providing a robust understanding of out-of-pile fiber optic performance under different environmental factors. Highlighted in this report are two test configurations, transmission testing of optical fibers over a range of temperatures, and tensile testing of optical fibers identified through prior research as having potential for in-core use. The transmission temperature testing is conducted with high spectral resolution to study the influence of elevated temperatures on transmission. This testing has been conducted from room temperature up to 800ºC. The transmission testing was conducted by BSU at the Fiber Laser and Integrated photonics Research (FLaIR) laboratory. This testing will allow separation of radiation and temperature effects during in-core testing and allow for a more thorough understanding of radiation effects on fiber sensors. The tensile testing of optical fibers was conducted to provide a baseline for the strength of fiber optics. The fragile nature of glass fibers is a limitation in the deployment of fiber optics. Furthermore, intrinsic fiber optic sensors such as Fiber Bragg Gratings (FBG) add defects or damaged areas to the fiber which reduce its strength and can lead to broken sensors if not handled with care. The thermo-mechanical test facility enables the ability to quantitatively measure the strength of fibers with and without FBG’s over a temperature range. This information will be used to determine which types of FBG’s, and other sensors, are likely to survive the installation process. These tests will also be used to characterize the potential measurement range of fiber based strain sensors. The tensile testing was completed at INL in the HTTL Fiber Optics and Ultrasonic Technologies (FOUT) laboratory. Pure silica core (PSC) optical fibers have been shown to perform well in harsh environments. Transmission testing and tensile testing showed little change in fiber dynamic strength and transmission with elevated temperatures. There was no significant weakening of the fiber for temperatures up to 200ºC. Transmission at 1550 nm (a common wavelength used for optical sensors) showed minimal changes up to 800ºC with some improvement after 12 hours of annealing at 800ºC. This indicates that PSC optical fiber is a good candidate for in-pile testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field testing of thermoplastic encapsulants in high‐temperature installations

Abstract Recently there has been increased interest in using thermoplastic encapsulant materials in photovoltaic modules, but concerns have been raised about whether these would be mechanically stable at high temperatures in the field. Recently, this has become a significant topic of discussion in the development of IEC 61730 and IEC 61215. We constructed eight pairs of crystalline‐silicon modules and eight pairs of glass/encapsulation/glass thin‐film mock modules using different encapsulant materials, of which only two were formulated to chemically crosslink. One module set was exposed outdoors with thermal insulation on the back side in Mesa, Arizona, in the summer (hot‐dry), and an identical module set was exposed in environmental chambers. High‐precision creep measurements (±20 μ m) and electrical performance measurements indicate that despite many of these polymeric materials operating in the melt or rubbery state during outdoor deployment, no significant creep was seen because of their high viscosity, lower operating temperature at the edges, and/or the formation of chemical crosslinks in many of the encapsulants with age despite the absence of a crosslinking agent. Only an ethylene‐vinyl acetate ( EVA ) encapsulant formulated without a peroxide crosslinking agent crept significantly. In the case of the crystalline‐silicon modules, the physical restraint of the backsheet reduced creep further and was not detectable even for the EVA without peroxide. Because of the propensity of some polymeric materials to crosslink as they age, typical thermoplastic encapsulants would be unlikely to result in creep in the vast majority of installations.

14 SOLAR ENERGY↗

NASA Electric Aircraft Test Bed (NEAT) Development Plan - Design, Fabrication, Installation

As large airline companies compete to reduce emissions, fuel, noise, and maintenance costs, it is expected that more of their aircraft systems will shift from using turbofan propulsion, pneumatic bleed power, and hydraulic actuation, to instead using electrical motor propulsion, generator power, and electrical actuation. This requires new flight-weight and flight-efficient powertrain components, fault tolerant power management, and electromagnetic interference mitigation technologies. Moreover, initial studies indicate some combination of ambient and cryogenic thermal management and relatively high bus voltages when compared to state of practice will be required to achieve a net system benefit. Developing all these powertrain technologies within a realistic aircraft architectural geometry and under realistic operational conditions requires a unique electric aircraft testbed. This report will summarize existing testbed capabilities located in the U.S. and details the development of a unique complementary testbed that industry and government can utilize to further mature electric aircraft technologies.

Hybrid Electric↗

Electric Six Degree of Freedom Installation Timelapse (Six Degree of Freedom Dynamic Test System)

The Six-degree-of-freedom Dynamic Test System (SDTS) is a short-range real-time motion based testing platform. Its primary use at NASA/JSC has been for development and qualification testing of docking systems, robotic assisted berthing mechanisms, and dynamic attachment systems. The SDTS is a closed-loop force feedback system that can simulate on-orbit contact dynamics between two vehicles utilizing the actual mechanical interfaces for testing. The facility is controlled by interconnected computers running real-time simulation software that takes measured contact forces, integrates the equations of motion in real time, and provide those states back into the motion table. This infrastructure can also be used for non-mating applications such as relative position sensor testing/evaluations. The SDTS facility provides a superstructure for mounting test articles, multiple test sensors, an intercom network for voice communications, and a synchronized timing system for data acquisition that includes HD video. This time-lapse video shows the buildup and testing of a modern electric actuation system created by Mikrolar, Inc. at the Johnson Space Center. This motion base will replace the current hydraulic actuator system, which is been in use since the 1970s, for all-future NASA testing. Once the system goes through customization to provide JSC’s unique closed-loop environment, the facility will help certify docking system and attach mechanisms on the ground before we send the first woman and the next man to the lunar surface

hexapod↗

Time Constants for Optical Fiber Temperature Sensing using a Thermal Resistance Approach

Optical fibers are immune to electromagnetic interference, have no moving parts, no applied voltages, no special environmental conditions, and they are extremely small (100's of microns in diameter). The U.S. Department of Energy is interested in extending this technology to extremely high temperature radiation environments for the purposes of developing in-pile instrumentation for the restart of TREAT (Transient Reactor Test Facility). TREAT is an air-cooled, thermal, heterogeneous test reactor facility that was designed to evaluate reactor fuels and structural materials under conditions that simulate various types of transient overpower and under-cooling conditions that may be postulated to occur in a nuclear reactor. Spatially distributed temperature measurements can be made using an Optical Backscatter Reflectometer (such as, model 4600, manufactured by Luna Innovations, Inc.), coupled to single-mode optical fiber that is placed in an in-pile nuclear reactor testing facility. In-pile temperature sensing for the TREAT reactor will need to have a fast response to temperature changes, since the reactor pulse will be on the order of 100 msec. The sensors must also be robust enough to be installed in the testing facility; this requires the fibers to be in a protective capillary tubing that is made of a tough material, such as stainless steel. The temperature response of the fiber will be delayed by the capillary tubing. This paper discusses the characterization and modeling of the thermal time constants of the sensors. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Absorption at San Antonio with 3-Wavelength Photo Acoustic Soot Spectrometer, Tricolor Absorption Photometer (ASAPT) Field Campaign Report

Fine particulate matter (PM2.5; particulate matter with an aerodynamic diameter of 2.5μm and smaller) samples were collected at the University of Texas, San Antonio (UTSA) campus (29.57901, -98.62889) from May 15-30. An additional measurement at the UTSA site included aerosol absorption coefficient of PM1 (particulate matter with an aerodynamic diameter of 1.0μm and smaller) using a tricolor absorption photometer (TAP) (Brechtel Mfg. Inc., Hayward, California). The sampling site is approximately 15 miles northwest of downtown San Antonio and in close proximity to major highway 10 and is just south of a forested area. The setup of the sampler and TAP and collection of PM2.5 samples were completed by Baylor University’s graduate student, Subin Yoon. Three three-wavelength photoacoustic soot spectrometers (PASS-3s) were shipped to San Antonio for testing and possible data collection. R. Subramanian went to San Antonio to lead this effort with assistance from Yoon. Each instrument had a critical flaw that inhibited its use for this campaign. Two instruments had low laser power for each wavelength; in addition, there were power and overheating issues with the one instrument that was installed on a test basis. The third instrument had computer issues that impeded any testing. In short, these three instruments would require a major overhaul in terms of lasers and computer systems to be brought back to field capability. As a result, the filter-based optical measurements were added to the campaign as an alternate measurement that would provide mass absorption efficiency at a single wavelength, but no scattering measurement. The TAP instrument was successfully installed and collected data for San Antonio, but full use of the data would have required a co-located scattering measurement. This campaign was co-located with a Texas Commission on Environmental Quality (TCEQ) ozone field study. That TCEQ field study was a collaboration of the University of Houston (PI James Flynn), Rice University (Co-PI Robert Griffen), and Baylor University (Co-PIs Rebecca Sheesley and Sascha Usenko).

aerosols, tricolor absorption photometer, three-wa↗

Development and Testing of a Friction-Based Post-Installable Fiber-Optic Monitoring System for Subsea Applications

This paper presents the design and development of a friction-based coupling device for a fiber-optic monitoring system capable of measuring pressure, strain, and temperature that can be deployed on existing subsea structures. A summary is provided of the design concept, prototype development, prototype performance testing, and subsequent design refinements of the device. The results of laboratory testing of the first prototype performed at the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) are also included. Limitations of the initial concept were identified during testing and future design improvements were proposed and later implemented. These new features enhance the coupling of the sensor device and improve the monitoring system measurement capabilities. A major challenge of a post-installed instrumentation monitoring system is to ensure adequate coupling between the instruments and the structure of interest for reliable measurements. Friction-based devices have the potential to overcome coupling limitations caused by marine growth and soil contamination on flowlines, risers, and other subsea structures. The work described in this paper investigates the design and test of a friction-based coupling device (herein referred to as a friction clamp) which is suitable for pipelines and structures that are suspended in the water column as well as for those that are resting on the seabed. The monitoring elements consist of fiberoptic sensors that are bonded to a stainless steel clamshell assembly with a high-friction surface coating. The friction clamp incorporates a single hinge design to facilitate installation of the clamp and dual rows of opposing fasteners to distribute the clamping force along the structure. The friction clamp can be modified to be installed by commercial divers in shallow depths or by remotely operated vehicles in deep-water applications. NASA-JSC was involved in the selection and testing of the friction coating, and in the design and testing of the prototype clamp device. Four-inch diameter and eight-inch diameter sub-scale friction clamp prototypes were built and tested to evaluate the strain measuring capabilities of the design under different loading scenarios. The testing revealed some limitations of the initial design concept, and subsequent refinements were explored to improve the measurement performance of the system. This study was part of a collaboration between NASA-JSC and Astro Technology Inc. within a study called Clear Gulf. The primary objective of the Clear Gulf study is to develop advanced instrumentation technologies that will improve operational safety and reduce the risk of hydrocarbon spillage. NASA provided unique insights, expansive test facilities, and technical expertise to advance technologies that will benefit the environment, the public, and commercial industries.

Bentley, Nicole L.↗

Development and Testing of a Friction-Based Post-Installable Sensor for Subsea Fiber-Optic Monitoring Systems

This paper presents the design and development of a friction-based coupling device for a fiber-optic monitoring system that can be deployed on existing subsea structures. This paper provides a summary of the design concept, prototype development, prototype performance testing, and design refinements of the device. The results of the laboratory testing of the first prototype performed at the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) are included in this paper. Limitations of the initial design were identified and future design improvements were proposed. These new features will enhance the coupling of the device and improve the monitoring system measurement capabilities. A major challenge of a post-installed instrumentation monitoring system is to ensure adequate coupling between the instruments and the structure of interest for reliable measurements. Friction-based coupling devices have the potential to overcome coupling limitations caused by marine growth and soil contamination on subsea structures, flowlines or risers. The work described in this paper investigates the design of a friction-based coupling device (friction clamp), which is applicable for pipelines and structures that are suspended in the water column and those that are resting on the seabed. The monitoring elements consist of fiber-optic sensors that are bonded to a metal clamshell with a high-friction coating. The friction clamp has a single hinge design to facilitate the operation of the clamp and dual rows of opposing fasteners to distribute the clamping force on the structure. The friction clamp can be installed by divers in shallow depths or by remotely operated vehicles in deep-water applications. NASA-JSC was involved in the selection and testing of the friction coating, and in the design and testing of the prototype clamp device. Four-inch diameter and eight-inch diameter sub-scale friction clamp prototypes were built and tested to evaluate the strain measuring capabilities of the design under different loading scenarios. The testing revealed some limitations of the initial design concept, and subsequent refinements were explored to improve the measurement performance of the system. This study was part of a collaboration between NASA-JSC and Astro Technology, Inc. within a study called Clear Gulf. The primary objective of the Clear Gulf study is to develop advanced instrumentation technologies that will improve operational safety and reduce the risk of hydrocarbon spillage. NASA provided unique insights, expansive test facilities, and technical expertise to advance these technologies that would benefit the environment, the public, and commercial industries.

Bentley, Nicole↗

Development and Testing of a Friction-Based Post-Installable Sensor for Subsea Fiber-Optic Monitoring System

This paper presents the design and development of a friction-based coupling device for a fiber-optic monitoring system that can be deployed on existing subsea structures. This paper provides a summary of the design concept, prototype development, prototype performance testing, and design refinements of the device. The results of the laboratory testing of the first prototype performed at the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) are included in this paper. Limitations of the initial design were identified and future design improvements were proposed. These new features will enhance the coupling of the device and improve the monitoring system measurement capabilities. A major challenge of a post-installed instrumentation monitoring system is to ensure adequate coupling between the instruments and the structure of interest for reliable measurements. Friction-based coupling devices have the potential to overcome coupling limitations caused by marine growth and soil contamination on subsea structures, flowlines or risers. The work described in this paper investigates the design of a friction-based coupling device (friction clamp), which is applicable for pipelines and structures that are suspended in the water column and those that are resting on the seabed. The monitoring elements consist of fiber-optic sensors that are bonded to a metal clamshell with a high-friction coating. The friction clamp has a single hinge design to facilitate the operation of the clamp and dual rows of opposing fasteners to distribute the clamping force on the structure. The friction clamp can be installed by divers in shallow depths or by remotely operated vehicles in deep-water applications. NASA-JSC was involved in the selection and testing of the friction coating, and in the design and testing of the prototype clamp device. Four-inch diameter and eight-inch diameter sub-scale friction clamp prototypes were built and tested to evaluate the strain measuring capabilities of the design under different loading scenarios. The testing revealed some limitations of the initial design concept, and subsequent refinements were explored to improve the measurement performance of the system. This study was part of a collaboration between NASA-JSC and Astro Technology, Inc. within a study called Clear Gulf. The primary objective of the Clear Gulf study is to develop advanced instrumentation technologies that will improve operational safety and reduce the risk of hydrocarbon spillage. NASA provided unique insights, expansive test facilities, and technical expertise to advance these technologies that would benefit the environment, the public, and commercial industries.

Bentley, Nicole L.↗

Humidity effects on calibrations of radiation therapy electrometers

Purpose: To eliminate variation in electrometer calibration results caused by high humidity and suboptimal connectors on the standard capacitors and to implement hardware that prevents overloading of the input stage of electrometers during calibration. Methods: A humidity-controlled cabinet was installed to provide a low-humidity environment for the standard capacitors. All of the coaxial BNC connections were replaced with Triax (TRB) connectors with the exception of the output from the voltage source. A three-stage RC filter with cascaded RC low-pass sections was designed and tested. Results: The installation of the humidity cabinet resulted in a major improvement in the stability and reproducibility of the electrometer calibration system. For the three years since this upgrade, the Ionizing Radiation Standards (IRS) electrometer calibration results have been consistent regardless of the ambient relative humidity in the lab. The connector replacements improved grounding in the calibration circuit. The three-stage filter allows the voltage at the output to rise in an S-shaped waveform, resulting in a smooth rise of the current through the isolation resistor from zero and back again, with no abrupt transition. For the filter design chosen, 99.99% of the charge is delivered within 6 s. Conclusions: A three-way improvement to the calibration measurement system was successful in eliminating the observed variations, resulting in an electrometer calibration measurement system that is unaffected by humidity and allowing reliable year-round calibrations of any electrometer encountered since the implementation of these changes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Performance of an Air Cooled Condenser (ACC) Using SPX Wind Guide Technology at Coal-Based Thermoelectric Power Plants

This project added a new airflow enhancement technology to an existing ACC cooling process at a selected coal power plant. Airflow parameters and efficiency improvement for the main plant cooling process using the applied technology were determined and compared with the capabilities of existing systems. The project required significant planning and pre-test execution in order to reach the required Air Cooled Condenser system configuration for evaluation. A host Power Plant ACC system had to be identified, agreement finalized, and addition of the SPX ACC Wind Guide Technology completed on that site. Design of the modification, along with procurement, fabrication, instrumentation, and installation of the new airflow enhancement technology were executed. Baseline and post-modification cooling system data was collected and evaluated. The improvement of ACC thermal performance after SPX wind guide installation was clear. Testing of the improvement indicates there is a 5% improvement in heat transfer coefficient in high wind conditions and 1% improvement at low wind speed. The benefit increased with increasing wind speed. This project was completed on schedule and within budget.

01 COAL, LIGNITE, AND PEAT↗

Rapid Chill and Fill of a Liquid Hydrogen Tank Demonstrated

The NASA Lewis Research Center, in conjunction with Boeing North American, has been supporting the High Energy Upper Stage (HEUS) program by performing feasibility studies at Lewis Supplemental Multilayer Insulation Research Facility (SMIRF). These tests were performed to demonstrate the feasibility of chilling and filling a tank with liquid hydrogen in under 5 minutes. The goal of the HEUS program is to release a satellite from the shuttle cargo bay and then use a cryogenic (high-energy) upper stage to allow the satellite to achieve final orbit. Because of safety considerations, the propellant tanks for the upper stage will be launched warm and dry. They will be filled from the shuttle's external tank during the mission phase after the solid rocket boosters have jettisoned and prior to jettison of the external tank. Data from previous shuttle missions have been analyzed to ensure that sufficient propellant would be available in the external tank to fill the propellant tank of the proposed vehicle upper stage. Because of mission time-line considerations, the propellant tanks for the upper stage will have to be chilled down and filled in approximately 5 minutes. An existing uninsulated flight weight test tank was installed inside the vacuum chamber at SMIRF, and the chamber was evacuated to the 10(exp -5) torr range to simulate space vacuum conditions in the cargo bay with the doors open. During prerun operations, the facility liquid hydrogen (LH2) supply piping was prechilled with the vent gas bypassing the test article. The liquid hydrogen supply dewar was saturated at local ambient pressure and then pressurized with ambient temperature gaseous helium to the test pressure. A control system was used to ensure that the liquid hydrogen supply pressure was maintained at the test pressure.

Kudlac, Maureen T.↗