Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “information technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers

There is a concern that environmental-contamination caused corrosion may negatively affect Information Technology (IT) equipment reliability. Nineteen data centers in the United States and two in India were evaluated using Corrosion Classification Coupons (CCC) to assess environmental air quality as it may relate IT equipment reliability. The data centers were of two basic types: closed and outside-air cooled. A closed data center provides cool air to the IT equipment using air conditioning in which only a small percent age of the recirculation air is make-up air continuously supplied from outside to meet human health requirements. An outside-air cooled data center uses outside air directly as the primary source for IT equipment cooling. Corrosion measuring coupons containing copper and silver metal strips were placed in both closed and outside-air cooled data centers. The coupons were placed at each data center (closed and outside-air cooled types) with the location categorized into three groups: (1) Outside - coupons sheltered, located near or at the supply air inlet, but located before any filtering, (2) Supply - starting just after initial air filtering continuing inside the plenums and ducts feeding the data center rooms, and (3) Inside located inside the data center rooms near the IT equipment. Each coupon was exposed for thirty days and then sent to a laboratory for a corrosion rate measurement analysis. The goal of this research was to investigate whether gaseous contamination is a concern for U.S. data center operators as it relates to the reliability of IT equipment. More specifically, should there be an increased concern if outside air for IT equipment cooling is used To begin to answer this question limited exploratory measurements of corrosion rates in operating data centers in various locations were undertaken. This study sought to answer the following questions: (1) What is the precision of the measurements (2) What are the approximate statistical distributions of copper and silver corrosion rates in the sampled data centers(3) To what extent are copper and silver corrosion measurements related (4) What is the relationship of corrosion rate measurements between outside-air cooled data centers compared to closed data centers (5) How do corrosivity measurements relate to IT equipment failure rates The data from our limited sample size suggests that most United States data center operators should not be concerned with environmental gaseous contamination causing high IT equipment failure rates even when using outside-air cooling. The research team recommends additional basic research on how environmental conditions, specifically gaseous contamination, affect electronic equipment reliability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar Thermal Demonstration Project

HVAC Retrofit and Energy Efficiency Upgrades at Clark High School, Las Vegas, Nevada. The overall objectives of this project are to increase usage of alternative/renewable fuels, create a better and more reliable learning environment for the students, and reduce energy costs. Utilizing the grant resources and local bond revenues, the District proposes to reduce electricity consumption by installing within the existing limited space, one principal energy efficient 100 ton adsorption chiller working in concert with two 500 ton electric chillers. The main heating source will be primarily from low nitrogen oxide (NOX), high efficiency natural gas fired boilers. With the use of this type of chiller, the electric power and cost requirements will be greatly reduced. To provide cooling to the information technology centers and equipment rooms of the school during off-peak hours, the District will install water source heat pumps. In another measure to reduce the cooling requirements at Clark High School, the District will replace single pane glass and metal panels with Kalwall building panels. An added feature of the Kalwall system is that it will allow for natural day lighting in the student center. This system will significantly reduce thermal heat/cooling loss and control solar heat gain, thus delivering significant savings in heating ventilation and air conditioning (HVAC) costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Construction of Blaze at the University of Illinois at Chicago: A Shared, High-Performance, Visual Computer for Next-Generation Cyberinfrastructure-Accelerated Scientific, Engineering, Medical and Public Policy Research

The Blaze high-performance visual computing system serves the high-performance computing research and education needs of University of Illinois at Chicago (UIC). Blaze consists of a state-of-the-art, networked, computer cluster and ultra-high-resolution visualization system called CAVE2(TM) that is currently not available anywhere in Illinois. This system is connected via a high-speed 100-Gigabit network to the State of Illinois' I-WIRE optical network, as well as to national and international high speed networks, such as the Internet2, and the Global Lambda Integrated Facility. This enables Blaze to serve as an on-ramp to national cyberinfrastructure, such as the National Science Foundation’s Blue Waters petascale computer at the National Center for Supercomputing Applications at the University of Illinois at Chicago and the Department of Energy’s Argonne Leadership Computing Facility (ALCF) at Argonne National Laboratory. DOE award # DE-SC005067, leveraged with NSF award #CNS-0959053 for “Development of the Next-Generation CAVE Virtual Environment (NG-CAVE),” enabled us to create a first-of-its-kind high-performance visual computing system. The UIC Electronic Visualization Laboratory (EVL) worked with two U.S. companies to advance their commercial products and maintain U.S. leadership in the global information technology economy. New applications are being enabled with the CAVE2/Blaze visual computing system that is advancing scientific research and education in the U.S. and globally, and help train the next-generation workforce.

47 OTHER INSTRUMENTATION↗

Towards the Understanding of Induced Seismicity in Enhanced Geothermal Systems

This DOE funded project was a collaborative effort between Array Information Technology (AIT), the University of California at Berkeley (UCB), the Helmholtz Centre Potsdam - German Research Center for Geosciences (GFZ) and the Lawrence Berkeley National Laboratory (LBNL). It was also part of the European research project “GEISER”, an international collaboration with 11 European partners from six countries including universities, research centers and industry, with the goal to address and mitigate the problems associated with induced seismicity in Enhanced Geothermal Systems (EGS). The goal of the current project was to develop a combination of techniques, which evaluate the relationship between enhanced geothermal operations and the induced stress changes and associated earthquakes throughout the reservoir and the surrounding country rock. The project addressed the following questions: how enhanced geothermal activity changes the local and regional stress field; whether these activities can induce medium sized seismicity M > 3; (if so) how these events are correlated to geothermal activity in space and time; what is the largest possible event and strongest ground motion, and hence the potential hazard associated with these activities. The development of appropriate technology to thoroughly investigate and address these questions required a number of datasets to provide the different physical measurements distributed in space and time. Because such a dataset did not yet exist for an EGS system in the United State, we used current and past data from The Geysers geothermal field in northern California, which has been in operation since the 1960s. The research addressed the need to understand the causal mechanisms of induced seismicity, and demonstrated the advantage of imaging the physical properties and temporal changes of the reservoir. The work helped to model the relationship between injection and production and medium sized magnitude events that have jeopardized, and in some cases suspended, the generation of energy from EGS systems worldwide.

15 GEOTHERMAL ENERGY↗

Field data collection of miscellaneous electrical loads in Northern California: Initial results

This report describes efforts to measure energy use of miscellaneous electrical loads (MELs) in 880 San Francisco Bay Area homes during the summer of 2012. Ten regions were selected for metering: Antioch, Berkeley, Fremont, Livermore, Marin County (San Rafael, Novato, Fairfax, and Mill Valley), Oakland/Emeryville, Pleasanton, Richmond, San Leandro, and Union City. The project focused on three major categories of devices: entertainment (game consoles, set-top boxes, televisions and video players), home office (computers, monitors and network equipment), and kitchen plug-loads (coffee/espresso makers, microwave ovens/toaster ovens/toasters, rice/slow cookers and wine chillers). These categories were important to meter because they either dominated the estimated overall energy use of MELs, are rapidly changing, or there are very little energy consumption data published. A total of 1,176 energy meters and 143 other sensors were deployed, and 90% of these meters and sensors were retrieved. After data cleaning, we obtained 711 valid device energy use measurements, which were used to estimate, for a number of device subcategories, the average time spent in high power, low power and “off” modes, the average energy use in each mode, and the average overall energy use. Consistent with observations made in previous studies, we find on average that information technology (IT) devices (home entertainment and home office equipment) consume more energy (15.0 and 13.0 W, respectively) than non-IT devices (kitchen plug-loads; 4.9 W). Opportunities for energy savings were identified in almost every device category, based on the time spent in various modes and/or the power levels consumed in those modes. Future reports will analyze the collected data in detail by device category and compare results to those obtained from prior studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Brahman

The Adversary & Interdiction Methods (AIM) program provides training and capability assessment services to government agencies around the country. Interdisciplinary teams equipped with gear and radioactive sources are repeatedly fielded to offsite events to collaborate with law enforcement agencies at all levels of government. AIM has grown rapidly over the past three years. A knowledge management system as evolved along with the program but it has failed to keep pace. A new system is needed. The new system must comply with cybersecurity and information technology solutions already in place at an institutional level. The offsite nature of AIM activities must also be accommodated. Cost and schedule preclude the commissioning of new software and the procurement of expensive hardware. The new system must exploit in-house capabilities and be established quickly. A novel system is proposed. This solution centers on a recently introduced institutional file sharing capability called Syncplicity. AIM-authored software will be combined with a dedicated institutional account to vastly extend the capability of this resource. The new knowledge management system will reduce error and increase efficiency through automation and be accessible offsite via mobile devices.

42 ENGINEERING↗

Model of the Product Development Lifecycle.

While the increased use of Commercial Off-The-Shelf information technology equipment has presented opportunities for improved cost effectiveness and flexibility, the corresponding loss of control over the product's development creates unique vulnerabilities and security concerns. Of particular interest is the possibility of a supply chain attack. A comprehensive model for the lifecycle of hardware and software products is proposed based on a survey of existing literature from academic, government, and industry sources. Seven major lifecycle stages are identified and defined: (1) Requirements, (2) Design, (3) Manufacturing for hardware and Development for software, (4) Testing, (5) Distribution, (6) Use and Maintenance, and (7) Disposal. The model is then applied to examine the risk of attacks at various stages of the lifecycle.

He, Sunny L.↗

The AskIT Service Desk: A Model for Improving Productivity and Reducing Costs

This was prepared for the business process improvement presentation to the Department of Energy. Los Alamos National Laboratory provides a single point of contact, the AskIT Service Desk, to address issues that impact customer productivity. At the most basic level, what customers want is for their calls to be received, to get a response from a knowledgeable analyst, and to have their issues resolved and their requests fulfilled. Providing a centralized, single point of contact service desk makes initiating technical or business support simple for the customer and improves the odds of immediately resolving the issue or correctly escalating the request to the next support level when necessary. Fulfilling customer requests through automated workflow also improves customer productivity and reduces costs. Finally, customers should be provided the option to solve their own problems through easy access to self-help resources such as frequently asked questions (FAQs) and how-to guides. To accomplish this, everyone who provides and supports services must understand how these processes and functions work together. Service providers and those who support services must “speak the same language” and share common objectives. The Associate Directorate for Business Innovation (ADBI) began the journey to improve services by selecting a known service delivery framework (Information Technology Infrastructure Library, or ITIL). From this framework, components that contribute significant business value were selected.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Functional Requirements for an Electronic Work Package System

This document provides a set of high level functional requirements for a generic electronic work package (eWP) system. The requirements have been identified by the U.S. nuclear industry as a part of the Nuclear Electronic Work Packages - Enterprise Requirements (NEWPER) initiative. The functional requirements are mainly applied to eWP system supporting Basic and Moderate types of smart documents, i.e., documents that have fields for recording input such as text, dates, numbers, and equipment status, and documents which incorporate additional functionalities such as form field data “type“ validation (e.g. date, text, number, and signature) of data entered and/or self-populate basic document information (usually from existing host application meta data) on the form when the user first opens it. All the requirements are categorized by the roles; Planner, Supervisor, Craft, Work Package Approval Reviewer, Operations, Scheduling/Work Control, and Supporting Functions. The categories Statistics, Records, Information Technology are also included used to group the requirements. All requirements are presented in Section 2 through Section 11. Examples of more detailed requirements are provided for the majority of high level requirements. These examples are meant as an inspiration to be used as each utility goes through the process of identifying their specific requirements. The report’s table of contents provides a summary of the high level requirements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Residential Indoor Temperature Study

In this study, we are adding to the body of knowledge around answering the question: What are good assumptions for HVAC set points in U.S. homes? We collected and analyzed indoor temperature data from US homes using funding from the U.S. Department of Energy's Building America (BA) program, due to the program's reliance on accurate energy simulation of homes. Simulations are used to set Building America goals, predict the impact of new building techniques and technologies, inform research objectives, evaluate home performance, optimize efficiency packages to meet savings goals, customize savings approaches to specific climate zones, and myriad other uses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Evaluation of Energy Storage Options for Nuclear Power

Energy supply, distribution, and demand are continuing to evolve as new generation sources come online and new appliances are installed. A larger percentage of the United States (U.S.) energy mix is provided by variable energy sources such as wind and solar each year, and distributed generation is becoming more common. In parallel, an evolution in consumer products such as electrical vehicles, information technology devices for residential and industrial applications, and appliances is changing how energy is consumed. As a result of these trends, nuclear power plants (NPPs) are being called upon to operate more flexibly than ever before. Furthermore, advanced nuclear power plants (A-NPPs) might operate as part of an electricity system that looks very different than when the current NPP fleet was constructed. A-NPPs face the possibility that they will need to operate in an environment where flexibility (e.g., fast ramping) is more highly valued than stability (e.g., baseload generation for conventional demand curves). The current fleet of NPPs is struggling to remain economical in competitive markets in an era of historically low natural gas prices and renewable sources with very low marginal costs. These factors, overlaid with an ambiguous national policy related to nuclear energy and a decision-making context that struggles with multi-decade capital investments, raise key questions and present significant challenges to the economics of nuclear power in the evolving grid. Multiple factors could improve the economics of A-NPPs, including: (1) minimizing the need for active safety systems, (2) minimizing adoption of one-off reactor designs, (3) establishing policies that credit low carbon emitting technologies, and (4) integrating energy storage technologies that increase revenue and reduce costs through a combination of ancillary services, market hedging, and reduced costs via stable operation. This report focuses on Item (4), containing an overview, synthesis, and examination of energy storage options that could be integrated with nuclear generation. Figure 1 provides an overview of the 2015 energy mix by sector, which shows that NPPs are currently used exclusively for electricity generation that is ultimately consumed in the residential, commercial, and industrial sectors. Some areas for NPP energy growth in the future include power generation for electrified transportation and thermal generation for storage and industrial applications. Currently, most industrial thermal energy users combust fossil resources (i.e., coal or natural gas) to meet the energy needs of the processes, but heat from nuclear operations could also be used in certain specific applications.

25 ENERGY STORAGE↗

Loads as a Resource: Frequency Responsive Demand

Current power grid operation predominantly relies on scheduling and regulating generation resources to supply loads and balance load changes. Due to the inherent intermittency of renewable energy, more flexible and fast ramping capacity is required to compensate for the uncertainty and variability introduced by renewable energy resources. With the advancement of information technologies, power system end-use loads are becoming more agile and can participate in provision of balancing energy and other grid services. The use of demand response can greatly reduce the required generation reserve in a clean and environmentally friendly way. In this report, a new frequency responsive load (FRL) controller was proposed based on the GFA controller, which can respond to both over and under-frequency events. A supervisory control was introduced to coordinate the autonomous response from FRLs in order to overcome the issues of excessive system response due to high penetration of FRLs. The effectiveness of the proposed FRL controller was demonstrated by large-scale simulation studies on the WECC system. Specifically, the FRLs were deployed in the WECC system at different penetration levels to analyze the performance of the proposed strategy both with and without supervisory level control. While both methods have their own advantages, the case without supervisory control could lead to system-wide instability depending on the size of the contingency and the number of FRLs deployed in the system. In addition, the voltage impacts of this controller on distribution system were also carefully investigated. Finally, a preliminary measurement and verification approach was also developed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FY2017 Final Report: Power of the People: A technical ethical and experimental examination of the use of crowdsourcing to support international nuclear safeguards verification.

Recent advances in information technology have led to an expansion of crowdsourcing activities that utilize the “power of the people” harnessed via online games, communities of interest, and other platforms to collect, analyze, verify, and provide technological solutions for challenges from a multitude of domains. To related this surge in popularity, the research team developed a taxonomy of crowdsourcing activities as they relate to international nuclear safeguards, evaluated the potential legal and ethical issues surrounding the use of crowdsourcing to support safeguards, and proposed experimental designs to test the capabilities and prospect for the use of crowdsourcing to support nuclear safeguards verification.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Interoperability Strategic Vision

The Interoperability Strategic Vision whitepaper aims to promote a common understanding of the meaning and characteristics of interoperability and to provide a strategy to advance the state of interoperability as applied to integration challenges facing grid modernization. This includes addressing the quality of integrating devices and systems and the discipline to improve the process of successfully integrating these components as business models and information technology improve over time. The strategic vision for interoperability described in this document applies throughout the electric energy generation, delivery, and end-use supply chain. Its scope includes interactive technologies and business processes from bulk energy levels to lower voltage level equipment and the millions of appliances that are becoming equipped with processing power and communication interfaces. A transformational aspect of a vision for interoperability in the future electric system is the coordinated operation of intelligent devices and systems at the edges of grid infrastructure. This challenge offers an example for addressing interoperability concerns throughout the electric system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Evaluation of Energy Storage Options for Nuclear Power

Energy supply, distribution, and demand are continuing to evolve as new generation sources come online and new appliances are installed. A larger percentage of the United States (U.S.) energy mix is provided by variable energy sources such as wind and solar each year, and distributed generation is becoming more common. In parallel, an evolution in consumer products such as electrical vehicles, information technology devices for residential and industrial applications, and appliances is changing how energy is consumed. As a result of these trends, nuclear power plants (NPPs) are being called upon to operate more flexibly than ever before. Furthermore, advanced nuclear power plants (A-NPPs) might operate as part of an electricity system that looks very different than when the current NPP fleet was constructed. A-NPPs face the possibility that they will need to operate in an environment where flexibility (e.g., fast ramping) is more highly valued than stability (e.g., baseload generation for conventional demand curves). The current fleet of NPPs is struggling to remain economical in competitive markets in an era of historically low natural gas prices and renewable sources with very low marginal costs. These factors, overlaid with an ambiguous national policy related to nuclear energy and a decision-making context that struggles with multi-decade capital investments, raise key questions and present significant challenges to the economics of nuclear power in the evolving grid. Multiple factors could improve the economics of A-NPPs, including: (1) minimizing the need for active safety systems, (2) minimizing adoption of one-off reactor designs, (3) establishing policies that credit low carbon emitting technologies, and (4) integrating energy storage technologies that increase revenue and reduce costs through a combination of ancillary services, market hedging, and reduced costs via stable operation. This report focuses on Item (4), containing an overview, synthesis, and examination of energy storage options that could be integrated with nuclear generation. Figure 1 provides an overview of the 2015 energy mix by sector, which shows that NPPs are currently used exclusively for electricity generation that is ultimately consumed in the residential, commercial, and industrial sectors. Some areas for NPP energy growth in the future include power generation for electrified transportation and thermal generation for storage and industrial applications. Currently, most industrial thermal energy users combust fossil resources (i.e., coal or natural gas) to meet the energy needs of the processes, but heat from nuclear operations could also be used in certain specific applications.

25 ENERGY STORAGE↗

Phase I Microgrid Cost Study: Data Collection and Analysis of Microgrid Costs in the United States

The U.S. Department of Energy (DOE) Office of Electricity Microgrid Cost Study project is looking at identifying the costs of components, integration and installation of U.S. microgrids and project cost improvements and technical accelerators over the next 5 years and beyond. This information could then be used by the DOE among others, to develop R&D agendas for the development of the next generation microgrids that provide cost effective, reliable and clean energy solutions. Microgrids are gaining in popularity because of their adaptability and flexible expandability, the need for increased electricity reliability, the increased affordability of distributed energy resources (DERs) and grid intelligence devices, goals to reduce greenhouse gas emissions, and other factors. The U.S. Department of Energy commissioned the National Renewable Energy Laboratory to complete a microgrid cost study and develop a microgrid cost model. The goal is to elucidate the variables that have the highest impact on costs as well as potential areas for cost reduction. This study consists of two phases. Phase I comprises the collection and analysis of data from microgrid projects built in the United States and is the subject of this report. In Phase II, NREL will assess current barriers facing the industry and identify potential solutions with help from industry representatives. Microgrid components are classified as follows in the form used to collect cost data from industry representatives for NREL's microgrid cost database: DERs: diesel, natural gas, combined heat and power (CHP), biofuel, solar photovoltaic (PV), wind, and fuel cell and energy storage; microgrid controller: primary, secondary, or tertiary; additional infrastructure: distribution system infrastructure, information technology communications upgrades, metering, etc.; soft costs: engineering, construction, commissioning, and regulatory. The purposes of Phase I are to better determine the contribution of individual components to total project size and to identify cost differences in projects within the same market segment. Phase II will use the results of Phase I to have an initial indication of the costs that might be driving the cost of development the most.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Seismic Analysis of Spatio-Temporal Fracture Generation During EGS Resource Development

This DOE GTO funded project was a collaborative effort between Array Information Technology and the University of California at Berkeley. The project goal is to improve technology to assess in-situ stress magnitude and orientation, kinematic fracture parameters, rupture size, rupture orientation as well as temporal changes and volumetric distribution of the injected fluid during Enhanced Geothermal System (EGS) resource development. The project leveraged high-frequency seismic data recorded by the LBNL 34-station permanent geophone network and seismic broadband data recorded by a temporary 33-station seismometer network that operated in The Geysers during the injection phase of the DOE GTO funded EGS demonstration project at the well Prati-32. The operation of the broadband network with high station density and good azimuthal coverage to monitor the injection phase produced an unprecedented dataset that is typically unavailable for EGS operations. The two datasets offer the advantages of studying the parameters under investigation over a broader frequency band and the higher sensitivity of the broadband seismometers resulted in a richer dataset with a lower magnitude of completeness. Moment tensor (MT) inversion have been employed to develop a catalog of earthquake source solutions including moment tensor and finite source rupture area. This resulted in a 168-event waveform-based seismic moment tensor catalog for events 0.7≤Mw≤3.9 based on a semi-automated moment tensor analysis technique. The MT solutions were used for in-situ stress estimation during the EGS injection phases. We found an approximate 15-degree counterclockwise rotation of the least compressive stress sigma-3, and a rotation of the maximum compressive stress sigma-1 toward the vertical as the injected volume of water increased. We developed a rupture-area magnitude scaling relationship of The Geysers earthquakes obtained from finite-source inversion for fault slip that reveals a very high correlation to published results. Based on the rupture area-magnitude relationship we mapped Mw from the LBNL earthquake catalog to estimate the activated fracture area, its location and orientation within the injection volume of Prati-32. The double-difference Wadati (DDW) technique was applied to high-accuracy P- and S-wave differential travel times derived from waveform cross correlation to image fluid saturation in the subsurface based on Vp/Vs-ratio. The recently developed technique has been applied to estimate temporal changes of fluid distribution in fault zones and in volcanic regions but not yet in engineered geo-reservoirs. The improvement of the technology includes high-resolution waveform cross correlation applied to the high-quality datasets with lower magnitude of completeness resulting in a higher number of recorded events. The improvement allowed to estimate both, the spatial and temporal distribution of injected fluids and the state of the injected fluid during reservoir stimulation. Results of the DDW analysis revealed the development of an injection-derived steam plume during the early injection phase, particularly in the northern part of the Prati-32 study area.

15 GEOTHERMAL ENERGY↗

Vehicle Cybersecurity Threats and Mitigation Approaches

Federal fleet managers and the information technology teams working with them need to understand the threats associated with modern vehicles. As vehicles become safer overall, the dangers change from distracted drivers to privacy intrusion and compromised operation. While fleet managers cannot necessarily change the configurations of manufacturer settings in mass market vehicles, they can influence what protective measures are taken in supplemental equipment or pilot-project vehicles. This report identifies security concerns, mitigation techniques, and procurement language that may be applicable in certain cases.

33 ADVANCED PROPULSION SYSTEMS↗