Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

ARCHER{sub RT} – A GPU-based and photon-electron coupled Monte Carlo dose computing engine for radiation therapy: Software development and application to helical tomotherapy

Purpose: Using the graphical processing units (GPU) hardware technology, an extremely fast Monte Carlo (MC) code ARCHER{sub RT} is developed for radiation dose calculations in radiation therapy. This paper describes the detailed software development and testing for three clinical TomoTherapy® cases: the prostate, lung, and head and neck. Methods: To obtain clinically relevant dose distributions, phase space files (PSFs) created from optimized radiation therapy treatment plan fluence maps were used as the input to ARCHER{sub RT}. Patient-specific phantoms were constructed from patient CT images. Batch simulations were employed to facilitate the time-consuming task of loading large PSFs, and to improve the estimation of statistical uncertainty. Furthermore, two different Woodcock tracking algorithms were implemented and their relative performance was compared. The dose curves of an Elekta accelerator PSF incident on a homogeneous water phantom were benchmarked against DOSXYZnrc. For each of the treatment cases, dose volume histograms and isodose maps were produced from ARCHER{sub RT} and the general-purpose code, GEANT4. The gamma index analysis was performed to evaluate the similarity of voxel doses obtained from these two codes. The hardware accelerators used in this study are one NVIDIA K20 GPU, one NVIDIA K40 GPU, and six NVIDIA M2090 GPUs. In addition, to make a fairer comparison of the CPU and GPU performance, a multithreaded CPU code was developed using OpenMP and tested on an Intel E5-2620 CPU. Results: For the water phantom, the depth dose curve and dose profiles from ARCHER{sub RT} agree well with DOSXYZnrc. For clinical cases, results from ARCHER{sub RT} are compared with those from GEANT4 and good agreement is observed. Gamma index test is performed for voxels whose dose is greater than 10% of maximum dose. For 2%/2mm criteria, the passing rates for the prostate, lung case, and head and neck cases are 99.7%, 98.5%, and 97.2%, respectively. Due to specific architecture of GPU, modified Woodcock tracking algorithm performed inferior to the original one. ARCHER{sub RT} achieves a fast speed for PSF-based dose calculations. With a single M2090 card, the simulations cost about 60, 50, 80 s for three cases, respectively, with the 1% statistical error in the PTV. Using the latest K40 card, the simulations are 1.7–1.8 times faster. More impressively, six M2090 cards could finish the simulations in 8.9–13.4 s. For comparison, the same simulations on Intel E5-2620 (12 hyperthreading) cost about 500–800 s. Conclusions: ARCHER{sub RT} was developed successfully to perform fast and accurate MC dose calculation for radiotherapy using PSFs and patient CT phantoms.

60 APPLIED LIFE SCIENCES↗

MO-H-19A-03: Patient Specific Bolus with 3D Printing Technology for Electron Radiotherapy

Purpose: Bolus is widely used in electron radiotherapy to achieve desired dose distribution. 3D printing technologies provide clinicians with easy access to fabricate patient specific bolus accommodating patient body surface irregularities and tissue inhomogeneity. This study presents the design and the clinical workflow of 3D printed bolus for patient electron therapy in our clinic. Methods: Patient simulation CT images free of bolus were exported from treatment planning system (TPS) to an in-house developed software package. Bolus with known material properties was designed in the software package and then exported back to the TPS as a structure. Dose calculation was carried out to examine the coverage of the target. After satisfying dose distribution was achieved, the bolus structure was transferred in Standard Tessellation Language (STL) file format for the 3D printer to generate the machine codes for printing. Upon receiving printed bolus, a quick quality assurance was performed with patient resimulated with bolus in place to verify the bolus dosimetric property before treatment started. Results: A patient specific bolus for electron radiotherapy was designed and fabricated in Form 1 3D printer with methacrylate photopolymer resin. Satisfying dose distribution was achieved in patient with bolus setup. Treatment was successfully finished for one patient with the 3D printed bolus. Conclusion: The electron bolus fabrication with 3D printing technology was successfully implemented in clinic practice.

60 APPLIED LIFE SCIENCES↗

WE-D-BRF-05: Quantitative Dual-Energy CT Imaging for Proton Stopping Power Computation

Purpose: To extend the two-parameter separable basis-vector model (BVM) to estimation of proton stopping power from dual-energy CT (DECT) imaging. Methods: BVM assumes that the photon cross sections of any unknown material can be represented as a linear combination of the corresponding quantities for two bracketing basis materials. We show that both the electron density (ρe) and mean excitation energy (Iex) can be modeled by BVM, enabling stopping power to be estimated from the Bethe-Bloch equation. We have implemented an idealized post-processing dual energy imaging (pDECT) simulation consisting of monogenetic 45 keV and 80 keV scanning beams with polystyrene-water and water-CaCl2 solution basis pairs for soft tissues and bony tissues, respectively. The coefficients of 24 standard ICRU tissue compositions were estimated by pDECT. The corresponding ρe, Iex, and stopping power tables were evaluated via BVM and compared to tabulated ICRU 44 reference values. Results: BVM-based pDECT was found to estimate ρe and Iex with average and maximum errors of 0.5% and 2%, respectively, for the 24 tissues. Proton stopping power values at 175 MeV, show average/maximum errors of 0.8%/1.4%. For adipose, muscle and bone, these errors result range prediction accuracies less than 1%. Conclusion: A new two-parameter separable DECT model (BVM) for estimating proton stopping power was developed. Compared to competing parametric fit DECT models, BVM has the comparable prediction accuracy without necessitating iterative solution of nonlinear equations or a sample-dependent empirical relationship between effective atomic number and Iex. Based on the proton BVM, an efficient iterative statistical DECT reconstruction model is under development.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-26: A Dosimetric Comparison of Two Treatment Setups for Lung Stereotactic Body Radiation Therapy (SBRT) Patients

Purpose: To assess the feasibility of treating lung SBRT patients with the ipsilateral arm adducted beside the body instead of elevated above the head. Methods: Patients receiving lung SBRT at our institution are typically treated with both arms raised above their head. However, several patients had difficulty maintaining their arms in an elevated position. In this study, lung SBRT patients who underwent PET-CT imaging with an adducted ipsilateral arm were selected to investigate the dosimetric effects of this treatment setup. PET-CT datasets were fused with treatment planning CT images to simulate the adducted arm position. One VMAT treatment plan was created per patient using the Pinnacle treatment planning system. Plans were optimized to achieve minimal dose to the ipsilateral arm while keeping the target coverage and critical structure doses within clinical limits. The target dose coverage, conformity index (CI) for the target, and DVHs of critical structures for the adducted arm plan were calculated. These parameters were compared with the clinical plan and reported along with the mean and maximum doses of the ipsilateral arm. Results: The target coverage, CI and DVHs for the adducted arm plans of two patients (one with peripheral lesion and one with central lesion) were comparable with the clinical plans. Dose constraints for the chest wall limited further reduction of ipsilateral arm doses for the peripheral lesion plan. The mean ipsilateral arm doses for the central and peripheral lesions were 0.33 Gy and 2.4 Gy, respectively. The maximum ipsilateral arm doses for the central and peripheral lesions were 1.0 Gy and 6.2 Gy, respectively. Conclusion: The results suggested patients with central lung SBRT tumors were more suitable for treatment with the adducted arm position. More patients with various lung tumor locations will be studied to find optimal tumor locations for treatment with this arm position.

60 APPLIED LIFE SCIENCES↗

SU-E-T-293: Dosimetric Analysis of Microscopic Disease in SBRT for Lung Cancers

Purpose: To evaluate the dosimetry of microscopic disease (MD) region of lung cancer in stereotactic body radiation therapy (SBRT). Methods: For simplicity, we assume organ moves along one dimension. The probability distribution function of tumor position was calculated according to the breathing cycle. The dose to the MD region was obtained through accumulating the treatment planning system calculated doses at different positions in a breathing cycle. A phantom experiment was then conducted to validate the calculated results using a motion phantom (The CIRS ‘Dynamic’ Thorax Phantom). The simulated breathing pattern used a cos4(x) curve with an amplitude of 10mm. A 3-D conformal 7-field plan with 6X energy was created and the dose was calculated in the average intensity projection (AIP) simulation CT images. Both films (EBT2) and optically stimulated luminescence (OSL) detectors were inserted in the target of the phantom to measure the dose during radiation delivery (Varian Truebeam) and results were compared to planning dose parameters. Results: The Gamma analysis (3%/3mm) between measured dose using EBT2 film and calculated dose using AIP was 80.5%, indicating substantial dosimetric differences. While the Gamma analysis (3%/3mm) between measured dose using EBT2 and accumulated dose using 4D-CT was 98.9%, indicating the necessity of dose accumulation using 4D-CT. The measured doses using OSL and theoretically calculated doses using probability distribution function at the corresponding position were comparable. Conclusion: Use of static dose calculation in the treatment planning system could substantially underestimate the actually delivered dose in the MD region for a moving target. Funding Supported by NSFC, No.81372436.

60 APPLIED LIFE SCIENCES↗

Three-dimensional modeling using x-ray shape-from-silhouette

We present the application of the shape-from-silhouette technique to reconstruct the three-dimensional profile of ancient handworks from their x-ray absorption images. The acquisition technique is similar to tomography, since the images are taken all around the object while it is rotated. Some reference points are placed on a small and light structure corotating with the object, and are acquired on the images for calibration and registration. The reconstruction algorithm gives finally the three-dimensional appearance of the handwork. We present the analysis of a bronze pendant of VI-VII century B.C. (Venetic area, Italy) completely hidden by corrosion products. The three-dimensional reconstruction shows that the pendant is a very elaborated piece, with two embraced figures that were completely invisible at the excavation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

JAXtronomy: A JAX port of lenstronomy

Gravitational lensing is a phenomenon where light bends around massive objects, resulting in distorted images seen by an observer. Studying gravitationally lensed systems provides insights into cosmology and astrophysics, including constraints of the expansion rate of the Universe and the distribution of dark matter. Thus, we introduce JAXtronomy, a re-implementation of the gravitational lensing software package lenstronomy (Birrer, 2021; Birrer & Amara, 2018) using JAX (Bradbury et al., 2018). JAX is a Python library that uses an accelerated linear algebra (XLA) compiler to improve the performance of computing software. Our core design principle of JAXtronomy is to maintain an identical API to that of lenstronomy. The main JAX features utilized in JAXtronomy are just-in-time compilation, which can lead to significant reductions in execution time, and automatic differentiation, which allows for the implementation of gradient-based algorithms that were previously impossible. Additionally, JAX allows code to be run on GPUs or parallelized across CPU cores, further boosting the performance of JAXtronomy.

astronomy↗

Constraints on the progenitor of SN 2016gKg from its shock-cooling light curve

SN 2016gkg is a nearby SN IIb discovered shortly after explosion. Like several other Type IIb events with early-time data, SN 2016gkg displays a double-peaked light curve, with the first peak associated with the cooling of a low-mass extended progenitor envelope. We present unprecedented intranight-cadence multi-band photometric coverage of the first light curve peak of SN 2016gkg obtained from the Las Cumbres Observatory Global Telescope network, the Asteroid Terrestrial-impact Last Alert System, the Swift satellite, and various amateur-operated telescopes. Fitting these data to analytical shock-cooling models gives a progenitor radius of ∼40–150 R{sub ⊙} with ∼2–40 × 10{sup −2} M{sub ⊙} of material in the extended envelope (depending on the model and the assumed host-galaxy extinction). Our radius estimates are broadly consistent with values derived independently (in other works) from HST imaging of the progenitor star. However, the shock-cooling model radii are on the lower end of the values indicated by pre-explosion imaging. Hydrodynamical simulations could refine the progenitor parameters deduced from the shock-cooling emission and test the analytical models.

79 ASTRONOMY AND ASTROPHYSICS↗

Methods for determining absorbed dose information

The disclosure discusses methods for determining absorbed dose information. A tomography imaging device generates an anatomy image relating to anatomy of a particular patient. A tomography imaging device also generates multiple radioactivity images regarding radioactivity distribution of an internally administered pharmaceutical over time in the particular patient. The radioactivity images related to the radioactivity distribution over time are registered. Each radioactivity image is combined with each anatomy image to create activity images. A Monte Carlo simulation for each activity image is run to obtain absorbed dose-rate images of the pharmaceutical at multiple times. The absorbed dose-rate images are integrated over time to obtain a total absorbed dose image. The absorbed dose-rate images and the total absorbed dose image are used to obtain a biologically effective dose (BED) image. The BED image is used to obtain an equivalent uniform does (EUD) of BED values for a chosen anatomical region.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Machine Learning for DUNE Supernova Trigger

One of the major scientific goals of the Deep Underground Neutrino Experiment (DUNE) is to detect and measure the neutrino flux originating from galactic core-collapse supernovae. These neutrinos provide an opportunity to study the end of life evolution of massive stars, and reveal information about the structure of core-collapse that is not visible in observations of the electromagnetic spectrum. Because of the rarity of these events, it is crucial that DUNE is able to detect supernova neutrino interactions when they occur. However, this will require sifting through a large quantity of data, motivating the development of a trigger algorithm to identify significant events and discard irrelevant data. Machine learning provides a potential approach to building this trigger. This project generates ADC and ground truth images of simulated neutrino interactions in a LArTPC detector to be used for machine learning, and uses them to train a sparse Convolutional Neural Network (C NN). The performance of this model when applied to the task of pixel classification based on interaction type is examined. This project found that the sparse CNN approach has the potential to have high accuracy in pixel classification, meaning it may be highly relevant to the development of a supernova neutrino trigger for the DUNE far detector.

Damish, S.↗

Accurate Dark Energy Constraints via the Precise Characterization of Galaxy Intrinsic Alignment Coupled with Shear and Redshift Interference

One of the most fundamental mysteries we face in physics is understanding what the nature of the dark energy component of our Universe is that causes the accelerated expansion of space. A powerful way to study dark energy is via weak gravitational lensing due to large-scale structure in the Universe, which we observe as tiny distortions in the shapes of very distant galaxies due to the bending of light by foreground mass. The Dark Energy Survey (DES) and Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) were designed to enable unprecedented measurements of these distortions in the shapes of galaxies to study dark energy. The intrinsic shapes of galaxies before they are distorted by weak gravitational lensing can cancel out some of the effects of lensing to obscure or bias what we infer about the nature of dark energy. This research program has led to improved image-level simulations of the Rubin Observatory LSST data. These simulations have made it possible to characterize for the first time the cosmic impact of these intrinsic shapes on biasing weak gravitational lensing calibration. This work will inform crucial improvements in methodology for studying dark energy with weak gravitational lensing at the precision promised by the the Rubin Observatory LSST over the next decade to ensure we are able to infer unbiased information about the nature of dark energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation of dose reduction in tomosynthesis

Purpose: Methods for simulating dose reduction are valuable tools in the work of optimizing radiographic examinations. Using such methods, clinical images can be simulated to have been collected at other, lower, dose levels without the need of additional patient exposure. A recent technology introduced to healthcare that needs optimization is tomosynthesis, where a number of low-dose projection images collected at different angles is used to reconstruct section images of an imaged object. The aim of the present work was to develop a method of simulating dose reduction for digital radiographic systems, suitable for tomosynthesis. Methods: The developed method uses information about the noise power spectrum (NPS) at the original dose level and the simulated dose level to create a noise image that is added to the original image to produce an image that has the same noise properties as an image actually collected at the simulated dose level. As the detective quantum efficiency (DQE) of digital detectors operating at the low dose levels used for tomosynthesis may show a strong dependency on the dose level, it is important that a method for simulating dose reduction for tomosynthesis takes this dependency into account. By applying an experimentally determined relationship between pixel mean and pixel variance, variations in both dose and DQE in relevant dose ranges are taken into account. Results: The developed method was tested on a chest tomosynthesis system and was shown to produce NPS of simulated dose-reduced projection images that agreed well with the NPS of images actually collected at the simulated dose level. The simulated dose reduction method was also applied to tomosynthesis examinations of an anthropomorphic chest phantom, and the obtained noise in the reconstructed section images was very similar to that of an examination actually performed at the simulated dose level. Conclusions: In conclusion, the present article describes a method for simulating dose reduction suitable for tomosynthesis. However, the method applies equally well to any digital radiographic system, although the benefits of correcting for DQE variations may be smaller.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-J-178: A Computer Simulation Model Observer for Task-Based Image Quality Assessment in Radiation Therapy

Purpose: Traditionally, image quality in radiation therapy is assessed subjectively or by utilizing physically-based metrics. Some model observers exist for task-based medical image quality assessment, but almost exclusively for diagnostic imaging tasks. As opposed to disease diagnosis, the task for image observers in radiation therapy is to utilize the available images to design and deliver a radiation dose which maximizes patient disease control while minimizing normal tissue damage. The purpose of this study was to design and implement a new computer simulation model observer to enable task-based image quality assessment in radiation therapy. Methods: A modular computer simulation framework was developed to resemble the radiotherapy observer by simulating an end-to-end radiation therapy treatment. Given images and the ground-truth organ boundaries from a numerical phantom as inputs, the framework simulates an external beam radiation therapy treatment and quantifies patient treatment outcomes using the previously defined therapeutic operating characteristic (TOC) curve. As a preliminary demonstration, TOC curves were calculated for various CT acquisition and reconstruction parameters, with the goal of assessing and optimizing simulation CT image quality for radiation therapy. Sources of randomness and bias within the system were analyzed. Results: The relationship between CT imaging dose and patient treatment outcome was objectively quantified in terms of a singular value, the area under the TOC (AUTOC) curve. The AUTOC decreases more rapidly for low-dose imaging protocols. AUTOC variation introduced by the dose optimization algorithm was approximately 0.02%, at the 95% confidence interval. Conclusion: A model observer has been developed and implemented to assess image quality based on radiation therapy treatment efficacy. It enables objective determination of appropriate imaging parameter values (e.g. imaging dose). Framework flexibility allows for incorporation of additional modules to include any aspect of the treatment process, and therefore has great potential for both assessment and optimization within radiation therapy.

60 APPLIED LIFE SCIENCES↗