Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high throughput”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Rapid Bayesian High Entropy Alloy Designs Fabricated via Wire Arc Additive Manufacturing

Purpose: This project seeks to demonstrate a new high-throughput (rapid) alloy design technique applied to creating new high entropy alloys (HEAs) for extreme environments. High entropy alloys shift the design paradigm from being focused on a single principal element (e.g. nickel-based alloys) to target alloys that include high atomic fractions (X >10%) of multiple elements. These HEA materials can exhibit sluggish diffusion and enhanced corrosion resistance, ideal for potential applications in advanced ultra supercritical (A-USC) steam cycles for power generation. Scope: The addition of multiple elements in high atomic fractions creates an enormous design space that cannot easily be investigated by traditional material design strategies such as designed of experiments (DOE). This project utilizes a Bayesian machine learning algorithm that has been modified to work with calculation of phase diagrams (CALPHAD) software. This Bayesian algorithm reduces manual inputs and increase the likelihood of achieving an optimal solution. Compositional inputs to this algorithm will be assessed using existing material property models for high temperature strength and corrosion resistance. The target for alloy performance will be a 15% (~100 ⁰C) increase in allowable service temperature beyond heat-resistant stainless steels while maintaining or improving alloy cost and corrosion resistance. Haynes 230 was selected as a baseline, which is 57 wt% Ni with 22 wt% Cr 14 wt% W, and 2 wt% Mo as solid solution strengtheners. In addition to rapid design via Bayesian machine learning, the alloys were rapidly fabricated using a multi-wire arc additive manufacturing (mWAAM) technique which allows for precise control of alloy composition and assessing of alloy design “windows” to study composition effects. Build speeds for wire-arc additive processes are among the highest for additive technologies enabling rapid and reliable sample fabrication when compared to conventional methods such as arc button melting. The mWAAM samples will be rapidly characterized via instrumented indentation for room temperature modulus and strength and for elevated temperature strength via hot hardness tests. After being screened with hardness testing, potential alloys will be further evaluated with conventional microscopy techniques including scanning electron microscopy (SEM) and transmission electron microscopy (TEM) to assess agreement with modeling results. The most promising compositions will also be evaluated by printing full sized tensile specimens for mechanical behavior tests at elevated temperatures. Results: Bayesian machine learning of a single performance function was initially used to optimize five performance metrics: 1) single phase stability, 2) yield strength, 3) creep resistance (low diffusion coefficient), 4) freezing range (weldability), and 5) material cost. The single performance function was suboptimal as assumptions had to be made about the results while formulating the optimization. A goal-oriented Bayesian optimization strategy (Hanaoka, 2021) was implemented with CALPHAD for use with the five metrics above. This multi-objective Bayesian optimization (MOBO) enabled the design of NiCrCoFe alloys with V and W additions. A base composition of NiCoCr was selected as Ni provides a stable FCC matrix, Cr aids corrosion/oxidation resistance, and Co is a solid-solutions strengthener that also improves creep by increasing the activation energy. Fe helps reduce diffusion coefficients and cost. Finally, V and W were selected for their reasonable solubility and high atomic misfit to aid in solid solution strengthening. Cracking of the mWAAM specimens was an early issue, and the Easton solidification cracking model (Easton et al., 2014a) was selected for addition to the MOBO function. High performing alloys fabricated by mWAAM included Ni 28 Cr 25 Co 26 Fe 15 V 8 and Ni 62 Cr 18 Co 1 Fe 3 W 15 . It was observed that even after adapting the mWAAM process for W, the W did not fully dissolve. To fully evaluate the Ni 62 Cr 18 Co 1 Fe 3 W 15 composition, a cored wire (80-20 NiCr sheath/powder core) was manufactured and printed via WAAM, and HIP’ing was utilized to homogenize and densify the printed alloy. The V and W alloys produced met metrics 1 (solid solution), 4 (solidification cracking), and 5 (cost). However, an unmodeled mechanism of thermal stress cracking was identified in the WAAM produced materials, perhaps exacerbated by the lack of grain boundary strengthening elements (B, C). Conclusions & Recommendations: A high-throughput (rapid) alloy design technique was applied to designing and manufacturing new high entropy alloys (HEAs) for extreme environments utilizing MOBO and mWAAM. The developed process was rapid and effective in addressing the mechanisms included in the model. The lack of grain boundary strengthening element additions (e.g., B, C) was a simplification that likely produced thermal stress cracking that turned into a large part of the investigation. Additions on the order of 0.005 wt% B and 0.05 wt% C likely would have minimized thermal stress grain boundary cracking. Overall, the high throughput design strategy is promising for rapid design of metrics-driven alloys for advanced ultra supercritical (A-USC) steam cycles for power generation. The MOBO and mWAAM process could be commercialized to accelerate metrics-driven alloy design. In addition, the cored-wire process utilized for scale-up is a promising high-volume process for WAAM alloy development and scale-up.

36 MATERIALS SCIENCE↗

Multiorder etalon sounder (MOES) development and test for balloon experiment

The Fabry-Perot interferometer (FPI), with its high throughput and high spectral resolution has been used in the remote-sensing measurements of the earth's atmospheric composition, winds, and temperatures. The most recent satellite instruments include the Fabry-Perot interferometer flown on the Dynamics Explorer-2 (DE-2), the High Resolution Doppler Imager (HRDI), and the Cryogenic Limb Array Etalon Spectrometer (CLAES) flown on the Upper Atmosphere Research Satellite (UARS). These instruments measure the Doppler line profiles of the emission and absorption of certain atmospheric species (such as atomic oxygen) in the visible and infrared spectral region. The successful space flight of DE-FPI, HRDI, and CLAES on UARS demonstrated the extremely high spectral resolution and ruggedness of the etalon system for the remote sensing of earth and planetary atmospheres. Recently, an innovative FPI focal plane detection technique called the Circle-to-Line Interferometer Optical (CLIO) system was invented at the Space Physics Research Laboratory. The CLIO simplifies the FPI focal plane detection process by converting the circular rings or fringes into a linear pattern similar to that produced by a conventional spectrometer, while retaining the throughput advantage of the etalon interferometer. The combination of FPI and CLIO allows the development of more sensitive Fabry-Perot interferometers in the infrared for the remote sensing of the lower atmospheres of Earth and possibly other planets. The Multiorder Etalon Sounder (MOES), a combination of the rugged etalon and the CLIO, compares very favorably to other space-borne optical instruments in terms of performance versus complexity. The new instrument is expected to be rugged, compact, and very suitable for an operational temperature and moisture sounder. With this technique, the contamination of radiance measurements by emissions of other gases is also minimized. At the Space Physics Research Laboratory (SPRL), the MOES concept and laboratory experiments were worked on for the past several years. Both theoretical studies and laboratory prototype experiments showed that MOES is very competitive compared with other high resolution sounders in terms of complexity and performance and has great potential as a compact and rugged high resolution atmospheric temperature and trace species sounder from the polar platform or the geostationary platform. The logical next step is to convert our laboratory prototype to a balloon instrument, so that field test of MOES can be carried out to prove the feasibility and capability of this new technology. Some of the activities related to the development of MOES for a possible balloon flight demonstration are described. Those research activities include the imaging quality study on the CLIO, the design and construction of a MOES laboratory prototype, the test and calibration of the MOES prototype, and the design of the balloon flight gondola.

Hays, Paul B.↗

"The Reflection Grating Spectrometer on Constellation-X"

The Constellation-X Reflection Grating Spectrometer (RGS) is designed to provide high-throughput, high-resolution spectra in the long wavelength band of 6 to 50 angstrom. In the nominal design an array of reflection gratings is mounted at the exit of the Spectroscopy X-ray Telescope (SXT) mirror module. The gratings intercept and disperse light to a designated array of CCD detectors. To achieve the throughput (A_eff > 1000 cm2 below 0.6 keV) and resolution (R > 300 below 0.6 keV) requirements for the instrument we are investigating two possible grating designs. The first design uses in-plane gratings in a classical configuration that is very similar to the XMM-Newton RGS. The second design uses off-plane gratings in a conical configuration. The off-plane design has the advantage of providing higher reflectivity and potentially, a higher spectral resolution than the in-plane configuration. In our presentation we will describe the performance requirements and the current status of the technology development.

Cottam, J.↗

Remote sounding of tropospheric minor constituents

The etalon interferometer, or Fabry-Perot interferometer (FPI), with its high throughput and high spectral resolution was widely used in the remote-sensing measurements of the earth's atmospheric composition, winds, and temperatures. The most recent satellite instruments include the Fabry-Perot interferometer flown on the Dynamics Explorer-2 (DE-2) and the High Resolution Doppler Imager (HRDI) to be flown on the Upper Atmosphere Research Satellite (UARS). These instruments measure the Doppler line profiles of the emission and absorption of certain atmospheric species (such as atomic oxygen) in the visible spectral region. The successful space flight of DE-FPI and the test and delivery of UARS-HRDI demonstrated the extremely high spectral resolution and ruggedness of the etalon system for the remote sensing of earth and planetary atmospheres. Recently, an innovative FPI focal plane detection technique called the Circle-to-Line Interferometer Optical (CLIO) system was invented at the Space Physics Research Laboratory (SPRL). The CLIO simplifies the FPI focal plane detection process by converting the circular rings or fringes into a linear pattern similar to that produced by a conventional spectrometer, while retaining the throughput advantage of the etalon interferometer. CLIO makes the use of linear array detectors more practical and efficient with FPI, the combination of FPI and CLIO represents a very promising new technique for the remote sensing of the lower atmospheres of Earth, Mars, Venus, Neptune, and other planets. The Multiorder Etalon Spectrometer (MOES), as a combination of the rugged etalon and the CLIO, compares very favorably to other spaceborne optical instruments in terms of performance versus complexity. The feasibility of an advanced etalon spectrometer for the remote sensing of tropospheric trace species, particularly carbon monoxide (CO), nitrous oxide (N2O), and methane (CH4) was discussed. The etalon atmospheric spectroscopy techniques are described, instrument design and related technical issues are discussed. The primary objective is to establish the concept of atmospheric spectroscopy with the CLIO and etalon system and its applications for the measurements of tropospheric trace species analyze system requirements and performance, determine the feasibility of components and subsystem implementation with available technology, and develop inversion algorithm for retrieval simulation and data analysis.

Drayson, S. Roland↗

A Coincident CdTe Detector Array for Enhanced Nuclear Process Monitoring

Nuclear fuel cycle aqueous separation processes desire improved real-time material characterization and process monitoring techniques; gamma coincidence spectroscopy has the potential to meet this need in these high throughput and high radiation environments based on its ability to reduce background noise, thereby enhancing detection limits and improving isotopic identification accuracy. A detector array composed of three CdTe detectors was designed to surround a chemical processing pipe in a reprocessing facility and evaluate the feasibility of passively assaying the nuclear materials flowing though this measurement point. This array uses commercial off the shelf components that are radiation hard and highly efficiency at low energies relevant to actinide photon signatures. Detector efficiency characterizations, coincidence detection, and potential configuration improvements are presented here.

Good, Erin C.↗

Evaluating Retention Index Score Assumptions to Refine GC–MS Metabolite Identification

As metabolomics grows into a high-throughput and high demand research field, current metrics for the identification of small molecules in gas chromatography–mass spectrometry (GC–MS) still require manual verification. Though steps have been taken to improve scoring metrics by combining spectral similarity (SS) and retention index (RI), the problem persists. A large body of literature has analyzed and refined SS scores, but few studies have explicitly studied improvements to RI scores. Here, in this study, we examined whether uninvestigated assumptions of the RI score are valid and propose ways to improve them. Query RIs were matched to library RI with a generous window of ±35 to avoid unintentional removal of valid compound identifications. Each match was manually verified as a true positive (TP), true negative, or unknown. Metabolites with at least 30 TP identifications were included in downstream analyses, resulting in a total of 87 metabolites from samples of varying complexity and type (e.g., amino acid mixtures, human urine, fungal species, and so on.). Our results showed that the RI score assumptions of normality, consistent variance across metabolites, and a mean error centered at 0 are often violated. We demonstrated through a cross-validation analysis that modifying these underlying assumptions according to empirical metabolite-specific distributions improved the TP and negative rankings. Further, we statistically determined the minimum number of samples required to estimate distributional parameters for scoring metrics. Overall, this work proposes a robust statistical pipeline to reduce the time bottleneck of metabolite identification by improving RI scores and thus minimize the effort to complete manual verification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data-Driven Discovery of Linear Molecular Probes with Optimal Selective Affinity for PFAS in Water

Approaches to tackle the wide and growing variety of highly persistent per- and polyfluoroalkyl substances (PFAS) are of pressing global need because of their detrimental human health effects, such as cancer, birth defects, and hormone imbalance. Sensitive, selective, and easy-to-use real-time sensors to monitor and detect PFAS and sorbents to extract them are critical to meeting government-mandated environmental concentrations. In this work, we combine all-atom molecular dynamics simulations, enhanced sampling, deep representational learning, and Bayesian optimization to perform high-throughput virtual screening for highly sensitive and selective molecular probes. Our molecular design space consists of 3850 linear hydrocarbon chains with varying degrees of halogenation with and without amine- and phosphine-based headgroups. By employing a data-driven search process, we efficiently explore the molecular design space to optimize the sensitivity to perfluorooctanesulfonic acid (PFOS) as a prototypical PFAS analyte and selectivity relative to a sodium dodecyl sulfate (SDS) interferent. We calculate 504 Gibbs free energies of probe-analyte and probe-interferent interactions and identify probes with PFOS association free energies of up to (-ΔG PFOS ) = 9.8 ± 0.2 kJ/mol and selectivities relative to SDS of (-ΔΔG PFOS–SDS ) = 3.1 ± 1.5 kJ/mol. A C 11 Br 23 P(CH 3 ) 2 probe containing 11 backbone brominated carbons and a tertiary phosphine headgroup possesses the most sensitive binding constant to PFOS within the defined search space of K b PFOS = 177.4 ± 12.7, and a semibrominated probe C 5 H 11 C 7 Br 14 N(CH 3 ) 2 containing 12 backbone carbons and a tertiary amine headgroup possesses the highest selectivity relative to SDS of K b PFOS /K b SDS = 4.6 ± 1.7. A retrospective analysis of our data to extract interpretable design rules reveals that the sensitivity of linear hydrogenated probes increases by approximately 1 kJ/mol per C–C bond. The addition or removal of halogen atoms and amine or phosphine headgroups produces nonmonotonic changes in both sensitivity and selectivity with changes to the sensitivity of up to 2.5 kJ/mol. Finally, this work places empirical limitations on the performance of a wide range of linear probes for PFOS detection and offers a generic strategy for high-throughput computational screening to promote selective and sensitive binding.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low cost and massively parallel force spectroscopy with fluid loading on a chip

Current approaches for single molecule force spectroscopy are typically constrained by low throughput and high instrumentation cost. Herein, a low-cost, high throughput technique is demonstrated using microfluidics for multiplexed mechanical manipulation of up to ~4000 individual molecules via molecular fluid loading on-a-chip (FLO-Chip). The FLO-Chip consists of serially connected microchannels with varying width, allowing for simultaneous testing at multiple loading rates. Molecular force measurements are demonstrated by dissociating Biotin-Streptavidin and Digoxigenin-AntiDigoxigenin interactions along with unzipping of double stranded DNA of varying sequence under different dynamic loading rates and solution conditions. Rupture force results under varying loading rates and solution conditions are in good agreement with prior studies, verifying a versatile approach for single molecule biophysics and molecular mechanobiology. FLO-Chip enables straightforward, rapid, low-cost, and portable mechanical testing of single molecules that can be implemented on a wide range of microscopes to broaden access and may enable new applications of molecular force spectroscopy.

42 ENGINEERING↗

Intrinsically stretchable electrode array enabled in vivo electrophysiological mapping of atrial fibrillation at cellular resolution

Electrophysiological mapping of chronic atrial fibrillation (AF) at high throughput and high resolution is critical for understanding its underlying mechanism and guiding definitive treatment such as cardiac ablation, but current electrophysiological tools are limited by either low spatial resolution or electromechanical uncoupling of the beating heart. To overcome this limitation, here we introduce a scalable method for fabricating a tissue-like, high-density, fully elastic electrode (elastrode) array capable of achieving real-time, stable, cellular level-resolution electrophysiological mapping in vivo. Testing with acute rabbit and porcine models, the device is proven to have robust and intimate tissue coupling while maintaining its chemical, mechanical, and electrical properties during the cardiac cycle. The elastrode array records epicardial atrial signals with comparable efficacy to currently available endocardial-mapping techniques but with 2 times higher atrial-to-ventricular signal ratio and >100 times higher spatial resolution and can reliably identify electrical local heterogeneity within an area of simultaneously identified rotor-like electrical patterns in a porcine model of chronic AF.

60 APPLIED LIFE SCIENCES↗

Enabling Low-Overhead HT-HPC Workflows at Extreme Scale using GNU Parallel

GNU Parallel is a versatile and powerful tool for process parallelization widely used in scientific computing. This paper demonstrates its effective application in high-performance computing (HPC) environments, particularly focusing on its scalability and efficiency in executing large-scale high-throughput high-performance computing (HT-HPC) workflows. Through real-world examples, we highlight GNU Parallel’s performance across various HPC workloads, including GPU computing, container-based workloads, and node-local NVMe storage. Our results on two leading supercomputers, OLCF’s Frontier and NERSC’s Perlmutter, showcase GNU Parallel’s rapid process dispatching ability and its capacity to maintain low overhead even at extreme scales. We explore GNU Parallel’s application in massive parallel file transfers using a scheduled Data Transfer Node (DTN) cluster, emphasizing its broad utility in diverse scientific workflows. Beyond its direct application as a viable workflow manager, GNU Parallel can be employed in conjunction with other workflow systems as a "last-mile" parallelizing driver and as a quick prototyping tool to design and extract parallel profiles from application executions. We then argue that the potential for GNU Parallel to transform workflow management at extreme scales is substantial, paving the way for more efficient and effective scientific discoveries.

Maheshwari, Ketan↗

NACHOS, a CubeSat-based high-resolution UV-Visible hyperspectral imager for remote sensing of trace gases: system overview and science objectives

Here, the Nano-satellite Atmospheric Chemistry Hyperspectral Observation System (NACHOS) is a high-throughput (f/2.9), high spectral resolution (~1.3 nm optical resolution, 0.6 nm sampling) Offner-design hyperspectral imager operating in the 300-500 nm spectral region. The 1.5U instrument payload (1U optical system, 0.5U electronics module) is hosted by a 1.5U LANL-designed CubeSat bus to comprise a 3U complete satellite. Spectroscopically similar to NASA’s Ozone Monitoring Instrument (OMI), which provides wide-field global mapping of ozone and other gases at coarse spatial resolution, NACHOS fills the complementary niche of targeted measurements at much higher spatial resolution. With 350 across-track spatial pixels and a 15-degree across-track field of view, NACHOS will provide spectral imaging at roughly 0.4 km per pixel from 500 km altitude. NACHOS incorporates highly streamlined gas-retrieval algorithms for rapid onboard processing, alleviating the need to routinely downlink massive hyperspectral data cubes. We will discuss the instrument design, challenges in achieving mechanical robustness to launch vibration in such a compact instrument, the onboard calibration system, and gas-retrieval data downlink strategy. We will also discuss potential science missions, including monitoring of NO 2 as an easily detected proxy for anthropogenic fossil-fuel greenhouse gases, monitoring lowlevel SO 2 degassing at pre-eruptive volcanoes, H 2 CO from wildfires, and characterization of aerosols. The long-term vision is for a many-satellite constellation that could provide both high spatial resolution and frequent revisits for selected targets of interest. As an initial technology demonstration of this vision, the NACHOS project is currently slated to launch two CubeSats in early 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid solution centrifugation for safe, scalable, and efficient isotope separation

A general method of separating isotopes by centrifuging dissolved chemical compounds in a liquid is introduced. This technique can be applied to almost all elements and leads to large separation factors. The method has been demonstrated in several isotopic systems including Ca, Mo, O, and Li with single-stage selectivities of 1.046 to 1.067 per neutron mass difference (e.g., 1.43 in 40 Ca/ 48 Ca), which are beyond the capabilities of various conventional methods. Equations are derived to model the process, and the results agree with those of the experiments. The scalability of the technique has been demonstrated by a three-stage enrichment of 48 Ca with a total 40 Ca/ 48 Ca selectivity of 2.43, and the scalability is more broadly supported through analogies to gas centrifuge, whereby countercurrent centrifugation can further multiply the separation factor by 5 to 10 times per stage in a continuous process. Optimal centrifuge conditions and solutions can achieve both high-throughput and highly efficient isotope separation.

07 ISOTOPE AND RADIATION SOURCES↗

DIVA/DeviceEditor v6.1.2

DIVA is an end-to-end DNA design and construction management platform that streamlines how researchers design, build, and receive sequence-verified DNA constructs. Through a web-based BioCAD interface (DeviceEditor), researchers independently design DNA constructs and submit them to a centralized queue with a single action. Designs progress transparently through standardized states which allow researchers to track status and access finished constructs via a central DNA repository. Submitted designs are reviewed by dedicated staff for feasibility and optimization, reducing costly failures and improving downstream execution. Automated DNA assembly software optimizes construction strategies by reusing existing parts where possible and sourcing synthetic DNA only when needed. Standardized, sequence-agnostic assembly methods enable many independent constructs to be built in parallel using lab automation, dramatically increasing throughput. High-throughput next-generation sequencing is used to verify construct accuracy, with flexible platforms selected based on task requirements. Throughout the process, detailed success and failure data are captured and analyzed, enabling continuous improvement of assembly protocols. Compared to traditional, manual DNA construction workflows, DIVA offers higher scalability, transparency, reproducibility, and data-driven optimization.

Plahar, Hector [Lawrence Berkeley National Laborat↗

Scintillators

As concerns about the illicit movement of radioactive materials across international borders increase, so too has the need for increased protection of those borders both foreign and domestic. The challenge is not only to detect hidden radioactive materials, but also to distinguish them from legitimate radionuclides such as radio-pharmaceuticals that are often transported across borders and shipped throughout a country. With more than 600 U.S. border sites to protect, screening imported radioactive material requires a careful balance of high throughput and high search efficiency. However, these requirements are difficult to meet as rapid screening operations leave less time for radiation detectors to efficiently evaluate materials. In support of border security, Sandia developed organic glass scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New High-Entropy Perovskite Oxides with Increased Reducibility and Stability for Thermochemical Hydrogen Generation

This project aims to design, synthesize, and test a transformative class of High-Entropy Perovskite Oxides (HEPOs) as redox oxides to enable thermochemical hydrogen generation with improved stability, kinetics, and efficiency. These developed HEPOs are expected to demonstrate improved kinetics with oxygen surface exchange coefficient ( k > 7.5×10 -4 cm/s) in Budget Period (BP) 1, retain its structural stability in a broad range of oxygen non-stoichiometry (Δδ > 0.15) at a low operating reduction temperature of T red < 1400°C in BP 2, and deliver a H 2 yield of over 400 µmol per gram of oxide and high stability with less than 20% degradation after at least 50 cycles in BP 3. This project is feasible due to the unique thermodynamic properties (simultaneously increased reducibility and phase stability) and kinetic characters (stability against particle coarsening and potentially enhanced oxygen transport and surface reaction kinetics) of such HEPOs, and it is enabled by a unique active learning computational design approach. Computational studies have been conducted to investigate the oxygen vacancy formation in complex perovskite systems. * Accurate prediction of V O .. concentration with disordered A-site cations in Fe-based high-entropy perovskite oxides * Combined MC/DFT computation elucidates the mechanism of Co preference on the redox due to the strain introduced by local distortion. In this project, we explored a large number (~150) of perovskite compositions, which are listed in Tables 2 – 4). * All perovskite specimens have been synthesized through a high-throughput high-energy ball milling process, followed by the conventional sintering process. * XRD, SEM/EDS and TGA were performed to confirm the crystal structure, phase homogeneity and oxygen non-stoichiometry for compositionally complex perovskite oxides (CCPOs). * 110 compositions show single-phase from XRD * Unusual aliovalent doping effects in medium-entropy perovskite compositions. * V-shape relation between Δδ vs. x (La 1-x Sr x )(Mn 1/3 Fe 1/3 Ti 1/3 )O 3 * The highest reported hydrogen production for the CCPOs made in this project ( T re = 1350 ºC 30 min, T Ox = 1100 ºC 30 min) * B-site mixing (La 0.8 Sr 0.2 )(Mn 0.2 Fe 0.2 Co 0.4 Al 0.2 )O 3 : 89.97 ± 2.73 mmol H2 /mol oxide (395 ± 10 μmol/g oxide ) (i) No phase transformation during reactions when Co molar ratio is less than 61% (ii) Balance between intrinsic kinetics (oxygen surface exchange) and thermodynamics (oxygen non-stoichiometry) (iii) Preference of Co identified by in-situ XPS * A-site mixing (La 1/6 Pr 1/6 Nd 1/6 Gd 1/6 Ba 1/6 Sr1/6)MnO 3 : 98.48 mmol H2 /mol oxid e (~415 μmol/g oxide )

08 HYDROGEN↗

Sheet silicon cell/module technology

The cost involved in the performance of the standard operations for the manufacture of silicon wafers is insignificant in the case of space photovoltaics applications. It is, however, a decisive factor with respect to terrestrial applications of silicon photovoltaic devices. In 1975, a program was, therefore, begun to develop low cost silicon solar arrays for terrestrial applications. The goal was silicon-based photovoltaic (PV) modules ready for installation at a selling price of $0.50/watt (1975 dollars). Sheet and ribbon silicon growth held out the promise of reduced cost through continuous operation, high material throughput, high material utilization efficiency, and a product whose shape lent itself to the assembly of high packing density modules. Attention is given to ribbon growth technologies, sheet technology generic problems, and ribbon cell and module technology status. It is concluded that the potential for crystalline ribbon silicon appears to be better today than ever before.

Morrison, A. D.↗

Status of GaAs solar cell production

Recent experience in producing GaAs solar cells, to meet the full requirements of space-array manufacturers is reviewed. The main problems have been in extending MOCVD technology to provide high throughput of high quality epitaxial layers, and to integrate the other important factors needed to meet the full range of user requirements. Some discussion of evolutionary changes is also given.

Yeh, Milton↗

A new Fabry-Perot spectrometer for observations of diffuse near-infrared line emission

We describe a new Fabry-Perot spectrometer that is optimized for the detection of extended, low-surface-brightness line emission from 1.4 to 2.4 microns. The instrument combines high throughput and high sensitivity, yet limits the background radiation falling on the detector. The instrument has a single 20 sec - 200 sec beam and a resolving power lambda/delta(lambda) approximately 2500. The system is background shot-noise limited in the K window and limited by a combination of read noise, dark-current shot noise, and fluctuations in the OH airglow lines in the H window. We present sample data of some of the lowest-surface-brightness H2 line emission in the near infrared obtained to date.

Luhman, M. L.↗