Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat transfer coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Updated Thermofluid Performance of the Simplified Flat Variant of the HEMJ

Our group has recently developed and studied “finger”-type divertors that are a simplified version of the helium-cooled modular divertor with multiple jets (HEMJ) using coupled computational fluid dynamics and thermal stress simulations. Such a simplified geometry could reduce complexity and cost given the large number of fingers required to cover the total divertor target area. Previous experimental studies for this simplified flat design reported lower heat transfer coefficients and higher pressure drops than the HEMJ, contrary to numerical predictions. Subsequent measurements determined that the original test section had significant dimensional variations in the jet exit holes. A new test section was therefore manufactured and tested in the Georgia Tech (GT) helium loop. The experimental results presented here for this test section at maximum heat flux of 7.1 MW/m 2 are in good agreement with numerical predictions. Correlations developed from these experimental data are extrapolated to predict the maximum heat flux that can be accommodated by the flat design and the coolant pumping power requirements under prototypical conditions. Lastly, numerical simulations are used to estimate the sensitivity of the flat design to geometric variations typical of manufacturing tolerances and variations in the gap width.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System Design of a 2.0 MWth Sodium/Molten Salt Pilot System

Nitrate molten salt concentrating solar power (CSP) systems are currently deployed globally and are considered state-of the art heat transfer fluids (HTFs) for present day high-temperature operation. Although slightly higher limits may be possible with molten salt, to fully realize SunShot efficiency goals of $15/kWhth HTFs and an LCOE of 6¢/kWh, HTF technologies working at higher temperatures (e.g., 650 °C to 750 °C) will require an alternative to molten salts, such as with alkali metal systems. This investigation explores the development of a 2.0 MWth sodium receiver system that employs a sodium receiver as the HTF, as well as with a ternary chloride (20%NaCl/40%MgCl/40%KCl by mol wt.%) salt as a thermal energy storage (TES) medium to facilitate a 6-hr. storage duration. A sodium-to-salt heat exchanger model as well as a salt-to-sCO2 primary heat exchanger model are employed and evaluated in this investigation. A thermodynamic system design model was developed using Engineering Equation Solver (EES) where state properties were calculated at inlets and outlets along both hot and cold legs of the pilot-scale plant. This investigation assesses receiver performance as well as system efficiency studies for the pump and system operational ranges. Results found that high efficiency sodium receivers were found to have higher heat transfer coefficients and required far less spreading of incident flux. The system performance model results suggest that for a pump speed of 2400 RPM, respective hot and cold pump TDH values were determined to be 260.1–307 ft. and 260.1–307 ft for pump flow rates of 90–120 GPM.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Dynamic condensation model of rolling droplets for high-performance heat transfer

Condensation is a critical process during vapor-liquid phase change in relation to heat transfer. To achieve a high heat transfer coefficient, the classical model for dropwise condensation requires a low contact angle and low contact angle hysteresis, failing to align with experimental observations on a hydrophobic and slippery quasi-liquid surface (QLS). Here, we report a dynamic condensation model that incorporates high-frequency condensate removal by emphasizing the role of timescale during droplet growth and shedding. Our model agrees well with the experimental result that a surface with high contact angle and low contact angle hysteresis promotes condensation, particularly during rolling-propelled condensate removal. Particle image velocimetry reveals that rolling droplets on a hydrophobic QLS exhibit 4-fold higher shedding speeds than the sliding droplets on a hydrophilic QLS, leading to significant heat transfer enhancement. This work deepens our theoretical understanding of condensation heat transfer and provides advanced physics-informed design rationales for water and energy systems.

42 ENGINEERING↗

Predicting Thermal Excursions During in situ Oxidative Regeneration of Packed Bed Catalytic Fast Pyrolysis Catalyst

Ex situ catalytic fast pyrolysis (CFP) uses a secondary reactor to upgrade biomass pyrolysis vapors to stabilized CFP oils with reduced oxygen content. In one configuration, the secondary reactor is operated as a packed-bed swing reactor system which allows coke-deactivated beds to be decarbonized in situ while other beds remain online for vapor upgrading. In situ decarbonization must be done carefully to avoid irreversible deactivation and/or physical degradation of catalyst pellets. Given that packed bed reactors are well known to have poor heat transfer characteristics, this is a critical issue impacting scaleability and commercial viability of the technology. To predict thermal excursions during regeneration, finite element computational models have been built to assist in scaling up oxidative decarbonization of a Pt/TiO2 CFP catalyst (0.5 mm spheres) from a bench scale packed bed with 100 g of catalyst to a pilot scale packed bed with 2 kg of catalyst and internal cooling tubes. Based on transient measurements of outlet temperature and effluent CO2 concentration, and using an assumed coke profile and activation energy, this paper demonstrates that specific combinations of effective thermal conductivity and wall heat transfer coefficient can fit bench scale oxidative regeneration data equally well. For the upscaled 2 kg bed, four bench-scale “best fit” parameter pairs give different predictions for location and magnitude of thermal excursions, with the maximum computed bed temperature gradients ranging from 30 °C cm-1 to as high as 3000 °C cm-1. The larger the fraction of heat removal by conduction through the cooling tubes, the greater the differences between the parameter pairs. The modelling results presented in this paper cast doubt on the industrial viability of the proposed combination of catalyst, bed and regeneration process, and point to the need for alternate reactor designs. However, there is considerable uncertainly in some of the key model parameters. The reliability of model predictions can be increased by adding more temperature measurements at key bed locations, testing additional variations in process conditions, performing careful bed dissections to determine the true coke profile, and perhaps most importantly, directly measuring the effective thermal conductivity of the catalyst pellets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic Behavior of Oval-Twisted Helical Tube Heat Exchanger: Numerical Study with RELAP5-3D

Convective heat transfer characteristics and theoretical thermal stress behaviors are numerically calculated using RELAP5-3D for the helical-coiled once-through steam generator (H-OTSG) and the novel heat exchanger design known as the oval-twisted helically coiled heat exchanger (OTHCHX) under (1) fluctuating wall temperature conditions, (2) square-wave pulsating flow conditions, and (3) the combined effects of fluctuating wall temperature and square-wave pulsating flow conditions. Heat transfer coefficient models for the H-OTSG and OTHCHX were developed based on existing data and implemented into RELAP5-3D, successfully capturing the N⁢uavg behavior within 8% to 10% of the reported data. Under fluctuating wall temperature conditions, the OTHCHX displayed higher N⁢u avg behavior than the H-OTSG. As 𝑓 increased, the $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ decreased. The $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ was higher for the OTHCHX than for the H-OTSG under fluctuating wall temperature conditions. Under pulsating flow conditions, the H-OTSG and OTHCHX displayed much higher 𝑁⁢𝑢 𝑎𝑣𝑔 than under constant flow conditions. The H-OTSG displayed a higher $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ over the OTHCHX. Under combined fluctuating wall temperature and pulsating flow conditions, the augmented heat transfer behavior from the pulsating flow was counteracted by the wall temperature fluctuations, producing slightly higher 𝑁⁢𝑢 𝑎𝑣𝑔 over constant wall temperature, constant flow conditions, but much lower than only constant pulsating flow under constant wall temperature conditions. The effects of simultaneous wall temperature fluctuations and square-wave pulsating flow caused higher $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ than that of only wall temperature fluctuations or pulsating flow. As the Reynolds number (Re) increased, $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ increased. However, when 𝑓=𝑓$_{\dot{m}}$, the $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ showed decreasing values as Re increased. In conclusion, the results indicate that thermal-fluid resonance can help mitigate thermal stresses.

Thermal stress↗

Heat transfer and pseudo phase transition for low-Reynolds, mixed-convection channel flow in the supercritical thermodynamic regime

Fluids at supercritical thermodynamic conditions are inherently complex due to the large variations in thermodynamic and transport properties. Multiple recent numerical and experimental investigations indicate ongoing interest for these fluids, especially supercritical CO and supercritical water, for a variety of applications. The potential heat transfer benefits in this regime are directly influenced by the extreme variations in thermodynamic and transport properties, which occur at, and above, the critical point. Limited studies have been conducted for low-Reynolds/intermediate-Rayleigh numbers mixed-convection channel flow of supercritical water, which is the focus of this study. To investigate the thermally driven hydrodynamic instabilities in this regime, we use a high-order fully-implicit numerical method. As expected, in this channel configuration and flow regime, a competition arises between the forced and the natural convection. Buoyancy, driven by the thermal gradient at the wall, pushes the fluid upwards in the channel, while inertial forces drive the fluid from inlet to outlet. We observe significant differences in the heat transfer coefficient between the top and bottom walls of the channel flow, due to natural convection, and unstable plumes. We further quantify the buoyancy forces along the channel flow through evaluation of the Richardson number. Simulations show that with a higher negative Richardson number, there are more unstable structures along the channel, resulting in enhanced mixing. Furthermore, we demonstrate the existence of gas-like, liquid-like, and the possibility of pseudo-two-phase regimes in the supercritical fluid. The pseudo-two-phase regime occurs when the range of fluid temperatures is crossing the pseudo-critical line, also known as the Widom line. The density of the fluid varies significantly near the Widom line, and further influences the natural convection and heat transfer in the flow.

42 ENGINEERING↗

Patterned Quasi-Liquid Surfaces for Condensation of Low Surface Tension Fluids

Extensive research concerns dropwise condensation of low surface tension fluids to promote energy efficiency and decarbonization in thermal energy systems. However, it is challenging as these fluids typically result in filmwise condensation. Drawing inspiration from the Namib desert beetle that enhances condensation through patterned wettability, conventional beetle-inspired surfaces excel in water condensation but flood when condensing low surface tension fluids. In this work, a patterned quasi-liquid surface is reported that achieves exceptional dropwise condensation of low surface tension fluids. The surface consists of alternating stripes with low surface energy, that is, a perfluoropolyether (PFPE) and fluorinated quasi-liquid surface (FQLS), that shows ultralow contact angle hysteresis for ethanol and hexane. Further, the PFPE stripes are slightly more slippery, acting as slippery bridges that accelerate droplet coalescence and removal. It is experimentally demonstrated that the striped PFPE-FQLS pattern exhibits a heat transfer coefficient 85%, 330%, and 550% higher than that of PFPE, fluorinated silane, and filmwise condensation, respectively. This study reveals that a high contact angle is desired to sustain dropwise condensation, irrespective of contact angle hysteresis. These findings provide a new paradigm for promoting the dropwise condensation of low surface tension fluids and offer valuable insights into surface design for energy sustainability.

36 MATERIALS SCIENCE↗

Electric Field Effect on Bubble Detachment in Variable Gravity Environment

The subject of the present study, the process of bubble detachment from an orifice in a plane surface, shows some resemblance to bubble departure in boiling. Because of the high heat transfer coefficients associated with phase change processes, boiling is utilized in many industrial operations and is an attractive solution to cooling problems in aerospace engineering. In terrestrial conditions, buoyancy is responsible for bubble removal from the surface. In space, the gravity level being orders of magnitude smaller than on earth, bubbles formed during boiling remain attached at the surface. As a result, the amount of heat removed from the heated surface can decrease considerably. The use of electric fields is proposed to control bubble behavior and help bubble removal from the surface on which they form. The objective of the study is to investigate the behavior of individual air bubbles injected through an orifice into an electrically insulating liquid under the influence of a static electric field. Bubble cycle life were visualized in terrestrial conditions and for several reduced gravity levels. Bubble volume, dimensions and contact angle at detachment were measured and analyzed for different parameters as gravity level and electric field magnitude. Situations were considered with uniform or non-uni form electric field. Results show that these parameters significantly affect bubble behavior, shape, volume and dimensions.

Iacona, Estelle↗

Experimental study of external fuel vaporization

The fuel properties used in the design of a flash vaporization system for aircraft gas turbine engines were evaluated in experiments using a flowing system to determine critical temperature and pressure, boiling points, dew points, heat transfer coefficients, deposit formation rates, and deposit removal. Three fuels were included in the experiments: Jet-A, an experimental referree broad specification fuel, and a premium No. 2 diesel fuel. Engine conditions representing a NASA Energy Efficient Engine at sea-level take-off, cruise, and idle were simulated in the vaporization system and it was found that single phase flow was maintained in the heat exchanger and downstream of the throttle. Deposits encountered in the heat exchanger represented a thermal resistance as high as 1300 sq M K/watt and a deposit formation rate over 1000 gC/sq cm hr.

Szetela, E. J.↗

Heat transfer measurements from a smooth NACA 0012 airfoil

Local convective heat transfer coefficients were measured from a smooth NACA 0012 airfoil having a chord length of 0.533 m. Flight data were taken for the smooth airfoil at Reynolds numbers based on chord in the range 1.24 to 2.50 million and at various angles of attack up to 4 deg. During these flight tests, the freestream velocity turbulence intensity was found to be very low. Wind tunnel data were acquired in the Reynolds number range 1.20 to 4.52 million and at angles of attack from -4 to +8 deg. The turbulence intensity in the IRT was 0.5-0.7 percent with the cloud-generating sprays off. A direct comparison between the results obtained in flight and in the IRT showed that the higher level of turbulence intensity in the IRT had little effect on the heat transfer for the lower Reynolds numbers but caused a moderate increase in heat transfer at the higher Reynolds numbers. Turning on the cloud-generating spray nozzle atomizing air in the IRT did not alter the heat transfer. The present data were compared with leading-edge cylinder and flat plate heat transfer correlations that are often used to estimate airfoil heat transfer in computer codes.

Poinsatte, Philip E.↗

Comparative Analysis of Direct and Indirect Cooling of Wide-Bandgap Power Modules and Performance Enhancement of Jet Impingement-Based Direct Substrate Cooling

With the development of high-power and high-torque machines, requirements for high-power density electronics are increasing. Thermal management of such systems requires high heat extraction. Conventional air cooling based heat sinks and cold plate based liquid cooling have their own benefits for various applications but has limitations for high power density applications. The current study explores a jet impingement based direct substrate cooling system that was implemented for a SiC based direct bonded Cu substrate for various power losses. Numerical comparison between jet impingement cooling and conventional horizontal/indirect cooling (pin fin heat sink and genetic algorithm-optimized heat sink) showed that the area weighted average of the heat transfer coefficient (HTC) is high for both horizontal cooling designs, and the local HTC is higher for jet impingement. Design iterations were undertaken to resolve the bottleneck of this cooling system. Increasing the number of nozzles helped to cover more area at the direct bonded Cu bottom plate, which drops the chip temperature considerably. With a constant flow rate, increasing the number of nozzles would decrease local jet velocity, which reduces the heat extraction by jet impingement. This issue can be addressed by reducing the diameter of nozzle but doing so results in a high pressure drop where the design constraint is 2 psi. A flared nozzle design is proposed, which has a higher spreading angle of the jet that increases the flow coverage and reduces the pressure drop of the coolant loop.

Barua, Himel↗

Heat and mass transfer in hygroscopic hydrogels

Sorption and desorption with hygroscopic hydrogels hold significant promise for thermal management, passive cooling, thermal energy storage, and atmospheric water harvesting. However, a comprehensive understanding of the energy and mass transport mechanisms in hygroscopic hydrogels remains missing, impeding accurate modeling and optimization. In this paper, we develop a model for the simultaneous vapor, water, and heat transfer in hygroscopic hydrogels during sorption and desorption processes. We show that by considering vapor diffusion in the hydrogel micropores, water diffusion in the polymer mesh, and heat transfer in the porous hydrogel, we can accurately capture experimentally observed thermally-driven desorption rates in these hydrogels. Furthermore, we consider three typical operating configurations of hydrogels and elucidate the differences in the transport mechanisms depending on the configuration. Finally, for each of these configurations, we identify key design parameters, including hydrogel thickness, hydrogel shear modulus, heat transfer coefficient, and thermal conductivity, and we parametrically show that by varying these parameters, a hygroscopic hydrogel can desorb up to 128.5%, 14.9%, 69.7%, and 9.6% more water, respectively, relative to the initial water content. This work provides a generic framework to model sorption and desorption processes in hygroscopic hydrogels which can guide the design and optimization in applications of thermal management, passive cooling, thermal energy storage, and atmospheric water harvesting with hydrogels.

36 MATERIALS SCIENCE↗

Vehicle Modeling During the Burning of Thermally Thick Samples in the Saffire V Experiments

In order to design a safer spacecraft in terms of fire prevention, detection and cleanup, the transport of combustion products and heat must be predicted. Large-scale fire data was provided by the Saffire payload within Northrup Grumman’s Cygnus vehicle after a resupply mission to the ISS. Solid materials, including thick thermoplastic samples were ignited to study flame spread and the effect a fire has on a vehicle. Sensors that measured species and temperature were placed within Cygnus. A model using Pyrosim was developed to predict the thick fuel burn events from Saffire V by using sensor data from Cygnus. The heat transfer coefficient between the cabin air and cargo was previously calibrated using the cotton fuel burn event, and provided a good prediction of the temperature response within the vehicle during the two thick fuel experiments. The difference between the Saffire inlet CO 2 sensor, and the forward port standoff CO 2 sensor, which is the closest to the Saffire outlet, was used as an input into the model. This method provided an excellent prediction of the CO 2 response in the other parts of the Cygnus.

fire safety↗

Shock interference peak heating measurements using phase change coatings

The phase change coating technique is used to obtain peak heating measurements in shock interference flow regions with high surface shear and heating. This technique provides heat transfer coefficients which are determined by measuring the time for a point on the surface to reach the phase change temperature of the thin fusible coating. Measurements were conducted on a 5.08-cm diameter hemisphere-cylinder made of silica based epoxy at Mach 6 for free stream Reynolds numbers of 3.3 to 25.6 million per meter. A sketch of the shock interference pattern produced by a flat plate shock generator is included. Heating data obtained on a 5.08-cm diameter stainless steel hemispherical model instrumented with thermocouples is presented for the purpose of comparing the phase change technique with the thermocouple-calorimeter technique.

Keyes, J. W.↗

CFD Simulations of Molten Salts Within Plasma-Facing Components with Twisted Tape Inserts Under One-Sided–Heated Conditions

For liquid immersion blankets (LIBs), the heat removal within different plasma-facing components (PFCs) requires substantial heat removal capabilities that could benefit from the usage of heat transfer enhancements. Of consideration are twisted tape insert heat transfer enhancements that are ribbon-like metal pieces inserted within cooling channels that increase fluid mixing, resulting in higher heat transfer and pressure drop. Unlike traditional applications, PFCs such as divertor coolant tubes experience a significantly higher heat flux on one side versus the other or entirely one-sided heating. These conditions are not well studied for molten salts where the higher Prandtl numbers characteristic of the fluids are significantly higher than water, gases, and liquid metals. As an effort to study this knowledge gap, large eddy simulations were done with Prandtl numbers representative of FLiBe at proposed operating conditions. In this study, the effects of applying a surface heat flux to one side of a tube versus the entire tube with a twisted tape insert were investigated for the heat transfer coefficient and effects on the temperature profile. The findings of the study suggest that for Prandtl number fluids above unity, the Nusselt number was largely unaffected by the change in boundary condition. Both boundary conditions showed good agreement with the Manglik and Bergles Nusselt number correlation for tight-fitting twisted tapes. Finally, the outcomes of this study will be useful for future design studies of LIBs to provide fundamental guidance implementing twisted tape inserts and their performance in one-sided–heated conditions.

molten salts↗

Heat Transfer in a Complex Trailing Edge Passage for a High Pressure Turbine Blade - Part 1: Experimental Measurements: Experimental Measurements - Part 1

A combined experimental and computational study has been performed to investigate the detailed heat transfer coefficient distributions within a complex blade trailing edge passage. The experimental measurements are made using a steady liquid crystal thermography technique applied to one major side of the passage. The geometry of the trailing edge passage is that of a two-pass serpentine circuit with a sharp 180-degree turning region at the tip. The upflow channel is split by interrupted ribs into two major subchannels, one of which is turbulated. This channel has an average aspect ratio of roughly 14:1. The spanwise extent of the channel geometry includes both area convergence from root to tip, as well as taper towards the trailing edge apex. The average section Reynolds numbers tested in this upflow channel range from 55,000 to 98,000. The tip section contains a turning vane near the extreme comer. The downflow channel has an aspect ratio of about 5:1, and also includes convergence and taper. Turbulators of varying sizes are included in this channel also. Both detailed heat transfer and pressure distribution measurements are presented. The pressure measurements are incorporated into a flow network model illustrating the major loss contributors.

Bunker, Ronald S.↗

Augmentation of Stagnation Region Heat Transfer Due to Turbulence From a DLN Can Combustor

Heat transfer measurements have been made in the stagnation region of a flat plate with a circular leading edge. Electrically heated aluminum strips placed symmetrically about the leading edge stagnation region were used to measure spanwise averaged heat transfer coefficients. The maximum Reynolds number obtained, based on leading edge diameter, was about 100,000. The model was immersed in the flow field downstream of an approximately half scale model of a can-type combustor from a low NO(x), ground based power-generating turbine. The tests were conducted with room temperature air; no fuel was added. Room air flowed into the combustor through six vane type fuel/air swirlers. The combustor can contained no dilution holes. The fuel/air swirlers all swirled the incoming airflow in a counter clockwise direction (facing downstream). A 5-hole probe flow field survey in the plane of the model stagnation point showed the flow was one big vortex with flow angles up to 36' at the outer edges of the rectangular test section. Hot wire measurements showed test section flow had very high levels of turbulence, around 28.5 percent, and had a relatively large axial-length scale-to-leading edge diameter ratio of 0.5. X-wire measurements showed the turbulence to be nearly isotropic. Stagnation heat transfer augmentation over laminar levels was around 77 percent and was about 14 percent higher than predicted by a previously developed correlation for isotropic grid generated turbulence.

VanFossen, G. James↗

Augmentation of Stagnation Region Heat Transfer Due to Turbulence from a DLN Can Combustor

Heat transfer measurements have been made in the stagnation region of a flat plate with a circular leading edge. Electrically heated aluminum strips placed symmetrically about the leading edge stagnation region were used to measure spanwise-averaged heat transfer coefficients. The maximum Reynolds number obtained, based on leading edge diameter, was about 100,000. The model was immersed in the flow field downstream of an approximately half-scale model of a can-type combustor from a low NO(x), ground-based power-generating turbine. The tests were conducted with room temperature air; no fuel was added. Room air flowed into the combustor through six vane-type fuel/air swirlers. The combustor can contained no dilution holes. The fuel/air swirlers all swirled the incoming airflow in a counterclockwise direction (facing downstream). A five-hole probe flow field survey in the plane of the model stagnation point showed the flow was one big vortex with flow angles up to 36 deg at the outer edges of the rectangular test section. Hot-wire measurements showed test section flow had very high levels of turbulence, around 28.5%, and had a relatively large axial-length scale-to-leading edge diameter ratio of 0.5. X-wire measurements showed the turbulence to be nearly isotropic. Stagnation heat transfer augmentation over laminar levels was around 77% and was about 14% higher than predicted by a previously developed correlation for isotropic grid-generated turbulence.

VanFossen, G. James↗