Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas compression”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

A finite element solver for 3-D compressible viscous flows

Computation of the flow field inside a space shuttle main engine (SSME) requires the application of state of the art computational fluid dynamic (CFD) technology. Several computer codes are under development to solve 3-D flow through the hot gas manifold. Some algorithms were designed to solve the unsteady compressible Navier-Stokes equations, either by implicit or explicit factorization methods, using several hundred or thousands of time steps to reach a steady state solution. A new iterative algorithm is being developed for the solution of the implicit finite element equations without assembling global matrices. It is an efficient iteration scheme based on a modified nonlinear Gauss-Seidel iteration with symmetric sweeps. The algorithm is analyzed for a model equation and is shown to be unconditionally stable. Results from a series of test problems are presented. The finite element code was tested for couette flow, which is flow under a pressure gradient between two parallel plates in relative motion. Another problem that was solved is viscous laminar flow over a flat plate. The general 3-D finite element code was used to compute the flow in an axisymmetric turnaround duct at low Mach numbers.

Reddy, K. C.↗

An Experimental and CFD Study of a Supersonic Coaxial Jet

A supersonic coaxial jet facility is designed and experimental data are acquired suitable for the validation of CFD codes employed in the analysis of high-speed air-breathing engines. The center jet is of a light gas, the coflow jet is of air, and the mixing layer between them is compressible. The jet flow field is characterized using schlieren imaging, surveys with pitot, total temperature and gas sampling probes, and RELIEF velocimetry. VULCAN, a structured grid CFD code, is used to solve for the nozzle and jet flow, and the results are compared to the experiment for several variations of the kappa - omega turbulence model

Cutler, A. D.↗

Fundamental Mixing and Combustion Experiments for Propelled Hypersonic Flight

Two experiments have been conducted to acquire data for the validation of computational fluid dynamics (CFD) codes used in the design of supersonic combustors. The first experiment is a study of a supersonic coaxial jet into stagnant air in which the center jet is of a light gas, the coflow jet is of air, and the mixing layer between them is compressible. The jet flow field is characterized using schlieren imaging, surveys with Pitot, total temperature and gas sampling probes, and RELIEF velocimetry. VULCAN, a structured grid CFD code, is used to solve for the nozzle and jet flow. The second experiment is a study of a supersonic combustor consisting of a diverging duct with single downstream-angled wall injector. Entrance Mach number is 2 and enthalpy is nominally that of Mach 7 flight. Coherent anti-Stokes Raman spectroscopy (CARS) has been used to obtain nitrogen temperature in planes of the flow, and surface pressures and temperatures have also been acquired. Modern-design-of-experiment techniques have been used to maximize the quality of the data set.

Cutler, A. D.↗

Static and aerothermal tests of a superalloy honeycomb prepackaged thermal protection system

A reusable metallic thermal protection system has been developed for vehicles with maximum surface temperatures of up to 2000 F. An array of two 12- by 12-in. panels was subjected to radiant heating tests that simulated Space Shuttle entry temperature and pressure histories. Results indicate that this thermal protection system, with a mass of 2.201 lbm/ft(exp 2), can successfully prevent typical aluminum primary structure of an entry vehicle like the Space Shuttle from exceeding temperatures greater than 350 F at a location on the vehicle where the maximum surface temperature is 1900 F. A flat array of 20 panels was exposed to aerothermal flow conditions, at a Mach number of 6.75. The panels were installed in a worst-case orientation with the gaps between panels parallel to the flow. Results from the aerothermal tests indicated that convective heating occurred from hot gas flow in the gaps between the panels. Proposed design changes to prevent gap heating occurred from hot gas flow in the gaps between the panels. Proposed design changes to prevent gap heating include orienting panels so that gaps are not parallel to the flow and using a packaged, compressible gap-filler material between panels to block hot gas flow in the gaps.

Gorton, Mark P.↗

Long-term strength retrogression of silica-enriched oil well cement: A comprehensive multi-approach analysis

The strength retrogression of a Class G cement enriched by adding 60–80% silica cured under the condition of 200 °C and 50 MPa were investigated by multiple different analysis methods. Short-term strength analysis suggests sonic strength testing is a poor indicator of real mechanical strength at such curing condition. Long-term testing up to 142 d shows all designed systems experiences dramatic deterioration in physical and mechanical properties, such as compressive strength, Young's modulus, water permeability and gas permeability. Further testing was conducted using X-ray diffraction, thermal gravimetric analysis, mercury intrusion and scanning electron microscope. The study reveals that the set cement experiences significant microstructure coarsening with increasing curing time, especially after 30 d curing. The strength retrogression and microstructure coarsening seem to be accompanied with the continued consumption of silica, and are likely caused by the gradual conversion of semi-crystalline C-S-H into crystalline tobermorite and xonolite over the long-term curing.

36 MATERIALS SCIENCE↗

Modeling Studies of PVT Growth of ZnSe: Current Status and Future Course

Bulk growth of wide band gap II-VI semiconductors by physical vapor transport (PVT) has been developed and refined over the past several years at NASA Marshall Space Flight Center. Results from a modeling study of PVT crystal growth of ZnSe are reported in this paper. The PVT process is numerically investigated using a two-dimensional formulation of the governing equations and associated boundary conditions. Both the incompressible Boussinesq approximation and a compressible model are tested to determine the influence of gravity on the process and to discern the differences between the two approaches. The influence of a residual gas is included in the models. The results show that both the incompressible and compressible approximations provide comparable results and the presence of a residual gas tends to measurably reduce the mass flux in the system. Detailed flow, thermal and concentration profiles are provided. The simulations show that the Stefan flux dominates the system flow field and the subtle gravitational effects can be gauged by subtracting this flux from the calculated profiles. Shear flows, due to solutal buoyancy, of the order of 50 microns/s for the liorizont,-d growth orientation and 10 microns/s for the vertical orientation are predicted. Whether these flows can fully account for the observed gravity related growth morphological effects and inhomogeneous solute and dopant distributions is a matter of conjecture. A template for future modeling efforts in this area is suggested which incorporates a mathematical approach to the tracking of the growth front based on energy of formation concepts.

Ramachandran, N.↗

Numerical Modeling of Crystal of ZnSe by Physical Vapor Transport - Towards a more Comprehensive Formulations

Crystal growth from the vapor phase has various advantages over melt growth. The main advantage is from a lower processing temperature which makes the process more amenable in instances where the melting temperature of the crystal is high. Other benefits stem from the inherent purification mechanism in the process due to differences in the vapor pressures of the native elements and impurities, and the enhanced interfacial morphological stability during the growth process. Further, the implementation of PVT growth in closed ampoules affords experimental simplicity with minimal needs for complex process control which makes it an ideal candidate for space investigations in systems where gravity tends to have undesirable effects on the growth process. Bulk growth of wide band gap II-VI semiconductors by physical vapor transport has been developed and refined over the past several years at NASA MSFC. Results from a modeling study of PVT crystal growth of ZnSe are reported in this paper. The PVT process is numerically investigated using both two-dimensional and fully three-dimensional formulation of the governing equations and associated boundary conditions. Both the incompressible Boussinesq approximation and the compressible model are tested to determine the influence of gravity on the process and to discern the differences between the two approaches. The influence of a residual gas is included in the models. The results show that both the incompressible and compressible approximations provide comparable results and the presence of a residual gas tends to measurably reduce the mass flux in the system. Detailed flow, thermal and concentration profiles will be provided in the final manuscript along with computed heat and mass transfer rates. Comparisons with the 1-D model will also be provided. The effect of gravity on the process from numerical computations shows subtle effects although experimental evidence from vertically and horizontally grown samples show dramatic evidence of gravitational effects. The shortcomings of the problem formulation will be discussed and a framework will be provided leading up towards a more comprehensive model of PVT systems.

Ramachandran, N.↗

A computational parametric study of ducted fuel injection implementation in a heavy-duty diesel engine

Experiments have shown that ducted fuel injection (DFI) effectively reduces soot emissions from direct-injection diesel engines. Although many computational studies have evaluated DFI’s spray development and soot reduction mechanisms in constant volume chambers, only limited computational work on internal combustion engines exists. The DFI duct assembly changes the engine’s in-cylinder flow, spray, and combustion development. Therefore, current production engine designs might not be optimal for achieving the best engine performance with DFI. Here, this work conducted an extensive numerical study to evaluate how parameter changes affect DFI performance. The parameters include swirl ratio, piston geometry, compression ratio (CR), number of injector orifices, split injection strategy, and exhaust gas recirculation (EGR) in a heavy-duty diesel engine utilizing DFI. The combustion and soot emission data from the Sandia compression ignition optical research engine were used for model validation. Simulations showed that an increased swirl ratio resulted in more intense jet flame-piston interaction, slowing down the combustion heat release during the late combustion stage and leading to lower indicated thermal efficiency (ITE) due to higher exhaust losses. A piston-bowl design with a reentrant inner piston edge yielded the highest thermal efficiency, due to the reduced cylinder head heat transfer loss. Additional injector orifices led to higher efficiency owing to a more advanced combustion phasing. Nevertheless, the maximum pressure rise rate (MPRR) and oxides of nitrogen (NO x ) emissions also increased with the number of injector orifices due to more rapid heat release and higher combustion temperature. Implementation of a split injection strategy combined with a higher EGR rate effectively inhibited the excessive MPRR and NO x formation. In general, the study concluded that DFI is not sensitive to most parameter changes but will benefit from future parameter optimization.

33 ADVANCED PROPULSION SYSTEMS↗

Numerical Study of Liquid Piston Compression Using Large-Eddy Simulation and Volume-of-Fluid Approach

Efforts to increase the efficiency of residential and commercial air conditioners and heat pumps have demonstrated that the compressor accounts for most of the system’s electrical energy usage. Therefore, the efficiency of this component should be improved to reduce its energy usage. The US Department of Energy’s Oak Ridge National Laboratory developed a near-isothermal liquid piston compressor (LPC) that uses propylene glycol (PG) to compress CO2. This report presents numerical studies of the LPC in which the compression chamber fills with injected PG from the bottom inlet. Numerical simulations were performed using the large-eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) subgrid-scale model coupled with the multiphase volume-of-fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfer within the compression chamber. In this effort, effects of boundary conditions applied to the LES-VOF calculations (e.g., no wall, an adiabatic wall, and a wall with a heat flux subscribed) to the overall pressure and temperature of CO2 gas as well as the transient evolution of flow and heat transfer evolution within the compression chamber are investigated and discussed. It was found that the LES calculation with no wall have shown no dynamical flow patterns and the volume-averaged temperature of CO2 increased from 305 to 392.7 K, while LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO2 temperatures. Results of LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO2 gas layers and circulation flow patterns within the chamber that contribute to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor.

Nguyen, Thien D.↗

Detonation duct gas generator demonstration program

The feasibility of the generation of detonation waves moving periodically across high speed channel flow is experimentally demonstrated. Such waves are essential to the concept of compressing requirements and increasing the engine pressure compressor with the objective of reducing conventional compressor requirements and increasing the engine thermodynamic efficiency through isochoric energy addition. By generating transient transverse waves, rather than standing waves, shock wave losses are reduced by an order of magnitude. The ultimate objective is to use such detonation ducts downstream of a low pressure gas turbine compressor to produce a high overall pressure ratio thermodynamic cycle. A 4 foot long, 1 inch x 12 inch cross-section, detonation duct was operated in a blow-down mode using compressed air reservoirs. Liquid or vapor propane was injected through injectors or solenoid valves located in the plenum or the duct itself. Detonation waves were generated when the mixture was ignited by a row of spark plugs in the duct wall. Problems with fuel injection and mixing limited the air speeds to about Mach 0.5, frequencies to below 10 Hz, and measured pressure ratios of about 5 to 6. The feasibility of the gas dynamic compression was demonstrated and the critical problem areas were identified.

Wortman, Andrew↗

Controlling Mass Transport in Direct Carbon Dioxide Zero-Gap Electrolyzers via Cell Compression

The development of high-performance CO 2 electrolyzers is crucial for accelerating the sustainable production of fuels and chemicals integrated with renewable energy sources. Here, we introduce a methodology to actively control mass transport inside a realistic zero-gap membrane electrode assembly of a CO 2 electrolyzer by varying the gasket thickness, which consequently changes the cell compression. This allows control over the thickness and porosity of the gas diffusion electrodes, influencing the overall electrolyzer performance, as demonstrated using Ag-deposited electrodes. At low operating voltages (<2.9 V), both high- and low-compression electrolyzers exhibit similar faradaic efficiencies and partial current densities for CO formation. However, at high voltages, the low-compression electrolyzer with high electrode porosity demonstrates superior CO selectivity and activity with suppressed H 2 formation. These experimental results are validated by the computational membrane electrode assembly (MEA) model developed by using the measured in situ electrode thicknesses and electrode porosities. Additionally, liquid electrolyte saturation at the catalyst layer is found to play a dominant role in determining the mass transport, resulting in a decreased electrolyzer performance with low electrode porosity. Finally, the systematic investigation in this study improves the understanding of the transport dynamics in MEA-based devices and provides insights into optimizing device design parameters for industry-relevant CO 2 electrolysis.

30 DIRECT ENERGY CONVERSION↗

Heating Augmentation Due to Compression Pad Cavities on the Project Orion CEV Heat Shield

An experimental study has been conducted to assess the effects of compression pad cavities on the aeroheating environment of the Project Orion CEV heat-shield. Testing was conducted in Mach 6 and Mach 10 perfect-gas wind tunnels to obtain heating measurements in and around the compression pads cavities using global phosphor thermography. Data were obtained over a wide range of Reynolds numbers that produced laminar, transitional, and turbulent flow within and downstream of the cavities. The effects of cavity dimensions on boundary-layer transition and heating augmentation levels were studied. Correlations were developed for transition onset and for the average cavity-heating augmentation.

Hollis, Brian R.↗

Compression Pad Cavity Heating Augmentation on Orion Heat Shield

An experimental study has been conducted to assess the effects of compression pad cavities on the aeroheating environment of the Project Orion Crew Exploration Vehicle heat shield. Testing was conducted in Mach 6 and 10 perfect-gas wind tunnels to obtain heating measurements in and around the compression pads cavities using global phosphor thermography. Data were obtained over a wide range of Reynolds numbers that produced laminar, transitional, and turbulent flow within and downstream of the cavities. The effects of cavity dimensions on boundary-layer transition and heating augmentation levels were studied. Correlations were developed for transition onset and for the average cavity-heating augmentation.

Hollis, Brian R.↗

Effect of nitric oxide and exhaust gases on gasoline surrogate autoignition: iso-octane experiments and modeling

Exhaust gas recirculation (EGR) is widely used in advanced internal combustion engines to reduce engine emissions as well as control combustion phasing. Among various species present in EGR gases, CO 2 and H 2 O are two major components that can thermally and chemically affect fuel autoignition. It is of fundamental interest to isolate the thermal and chemical effects of CO 2 and H 2 O on fuel autoignition, especially as such an effort has not been reported in the literature. Moreover, nitric oxide (NO) is known to exhibit strong chemical effects on fuel autoignition, which in turn affects engine combustion phasing. The effects of ultra-low NO addition (< 100 ppm) on fuel autoignition at low temperatures are also not well understood. Recognizing these problems, autoignition experiments of iso-octane (a major gasoline surrogate component) in air are performed in this study using a rapid compression machine at varying compressed pressures, equivalence ratios, dilution levels with an EGR gas analogue (consisting of CO 2 , H 2 O, O 2 , and N 2 ) and N 2 only, and varying amounts of NO addition. Furthermore, the thermal and chemical effects of the EGR gas analogue are isolated and evaluated by comparing the ignition delay time datasets of EGR and N2-only diluted cases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laboratory evaluation of cyclic underground hydrogen storage in the Temblor sandstone of the San Joaquin Basin, California

Underground Hydrogen Storage (UHS) in depleted oil and gas reservoirs could provide a cost-effective solution to balance seasonal fluctuations in renewable energy generation. However, data and knowledge on UHS at subsurface conditions are limited so it is difficult to estimate how effective this type of storage could be. In this study, we perform high pressure experiment to measure the effectiveness of cyclic hydrogen (H 2 ) storage in a specimen of Temblor sandstone retrieved from the San Joaquin Basin of California. Our experiment mimics reservoir pressure conditions to measure H 2 -brine relative permeability and fluid-rock interactions over the course of ten charging and discharging cycles. Initial gas breakthrough occurred at 15 % to 25 % H2 saturation in the specimen with 3 % NaCl brine as the resident fluid. Continuing injecting to 4 pore volumes (PV) of H 2 yielded an asymptotic H 2 saturation of 38 % to 41 %, a level often referred to as the irreducible gas saturation based on two-phase flow. The boundary condition in this study mimics the near wellbore region, which experiences bi-directional H 2 flow. This bi-directional flow led to evaporative drying of the specimen resulting in 94 % H 2 saturation at the end of 10th cycle. This indicates that cyclic flow and evaporative drying can lead to more efficient reservoir storage where a larger fraction of the reservoir porosity is usable to store H 2 . The produced gas stream consisted of H 2 mixed with 8 % to 22 % H 2 O, indicating formation dry-out by evaporation. Meanwhile, produced water chemistry indicated calcite and silicate dissolution, with calcite sourced from fossil fragments. This led to a loss of cementation and weakened the rock sample. Combined, our results indicate dry-out, compaction, increased H 2 saturation, rock weakening, and permeability loss during cyclic UHS. Overall, we anticipate that the combined effects should lead to higher than anticipated UHS storage efficiency per volume of sandstone reservoir rock.

08 HYDROGEN↗

Dynamic compression of TiO 2 to 221 GPa

The high-pressure dynamic response of titanium dioxide (TiO 2 ) is not only of interest because of its numerous industrial applications but also because of its structural similarities to silica (SiO 2 ). We performed plate impact experiments in a two-stage light gas gun, at peak stresses from 64 to 221 GPa to determine the TiO 2 response along the Hugoniot. The lower stress experiment at 64 GPa shows an elastic behavior followed by an elastic–plastic transition, whereas the high stress experiments above 64 GPa show a single wave structure. Previous shock studies have shown the presence of high-pressure phases (HPP) I (26 GPa) and HPP II (100 GPa); however, our data suggest that the HPP I phase is stable up to 150 GPa. Using a combination of data from our current study and our previous Z-data, we determine that TiO 2 likely melts on the Hugoniot at 157 GPa. Furthermore, our data confirm that TiO 2 is not highly incompressible as shown by a previous study.

36 MATERIALS SCIENCE↗

Space Flight Orthostatic Intolerance Protection

This paper summarizes investigations conducted on different orthostatic intolerance protection garments. This paper emphasizes on the engineering and operational aspects of the project. The current Shuttle pneumatic Anti-G Suit or AGS at 25 mmHg (0.5 psi) and customized medical mechanical compressive garments (20-30 mmHg) were tested on human subjects. The test process is presented. The preliminary results conclude that mechanical compressive garments can ameliorate orthostatic hypotension in hypovolemic subjects. A mechanical compressive garment is light, small and works without external pressure gas source; however the current garment design does not provide an adjustment to compensate for the loss of mass and size in the lower torso during long term space missions. It is also difficult to don. Compression garments that do not include an abdominal component are less effective countermeasures than garments which do. An early investigation conducted by the Human Adaptation and Countermeasures Division at Johnson Space Center (JSC) has shown there is no significant difference between the protection function of the AGS (at 77 mmHg or 1.5 psi) and the Russian anti-g suit, Kentavr (at 25 mmHg or 0.5 psi). Although both garments successfully countered hypovolemia-induced orthostatic intolerance, the Kentavr provided protection by using lower levels of compression pressure. This more recent study with a lower AGS pressure shows that pressures at 20-30 mmHg is acceptable but protection function is not as effective as higher pressure. In addition, a questionnaire survey with flight crewmembers who used both AGS and Kentavr during different missions was also performed.

Luty, Wei↗