The recovery of polarized apparent temperature distributions of flat scenes from antenna temperature measurements

The reception theory for quasi-monochromatic partially polarized emissions is employed to describe the antenna temperature when observing a flat scene from within or above an absorbing/emitting atmosphere. When the polarization aspects of the antenna and scene are carefully observed, the resulting integral expression for the antenna temperature differs significantly from that reported for polarization invariant temperature distributions. It is observed that the antenna couples to both emitted surface polarizations, and the phase character of the antenna introduces a term involving the product of the polarized and cross-polarized antenna patterns. A matrix approximation of the integral expression is suggested and developed as a means for inverting polarized antenna temperature observations for the underlying partially polarized apparent temperature distributions.

Claassen, J. P.↗

Testing of a flat conductor cable baseboard system for residential and commercial wiring

The results of extensive testing (mechanical, electrical, chemical, environmental, thermal, and analytical) are reported for a flat conductor cable baseboard system for residential and commercial wiring. In all of the tests, Underwriters Laboratories (UL) Standards, UL Tentative Test Programs, or Accepted Engineering Practices were followed during test selection, test setup, and test accomplishment.

Hankins, J. D.↗

Application of wave mechanics theory to fluid dynamics problems: Flat plate flow

The characteristics of the flow in the laminar boundary layer along an infinitely long flat plate are discussed. The flow may be disturbed or not, depending on the situation. The physical, natural aspects of the flow, either a laminar flow free from disturbances or a flow which originally is a laminar one with disturbances superimposed upon it. Oscillograms of turbulence in wind tunnel tests and in the wake of a cylinder are presented.

Krzywoblocki, M. Z. V.↗

Analysis of noise produced by jet impingement near the trailing edge of a flat and a curved plate

The sound fields produced by the interaction of a subsonic cold gas jet with the trailing edge of a large flat plate and a curved plate were analyzed. The analyses were performed to obtain a better understanding of the dominant noise source and the mechanism governing the peak sound-pressure-level frequencies of the broadband spectra. An analytical expression incorporating an available theory and experimental data predicts sound field data over an arc of approximately 105 deg measured from the upstream jet axis for the two independent sets of data. The dominant noise as detected on the impingement side of either plate results from the jet impact (eighth power of the velocity dependence) rather than a trailing-edge disturbance (fifth or sixth power of the velocity dependence). Also, the frequency of the peak SPL may be governed by a phenomenon which produces periodic formation and shedding of ring vortices from the nozzle lip.

Mckinzie, D. J., Jr.↗

Development of flat-plate solar collectors for the heating and cooling of buildings

The relevant design parameters in the fabrication of a solar collector for heating liquids were examined. The objective was to design, fabricate, and test a low-cost, flat-plate solar collector with high collection efficiency, high durability, and requiring little maintenance. Computer-aided math models of the heat transfer processes in the collector assisted in the design. The preferred physical design parameters were determined from a heat transfer standpoint and the absorber panel configuration, the surface treatment of the absorber panel, the type and thickness of insulation, and the number, spacing and material of the covers were defined. Variations of this configuration were identified, prototypes built, and performance tests performed using a solar simulator. Simulated operation of the baseline collector configuration was combined with insolation data for a number of locations and compared with a predicted load to determine the degree of solar utilization.

Ramsey, J. W.↗

Flat plate electrohydrodynamic heat pipe experiments

Performance capabilities of electrohydrodynamic (EHD) flat heat pipes were investigated using Freon 113 and Freon 11 as working fluids. All of the pipes employed straight rod electrodes to form axial liquid flow channels and tranverse grooves for capillary surface wetting. Results show: (1) the EHD pipe will prime under load, (2) voltage controlled conductance can be achieved by varying the active area of the evaporator, and (3) the average evaporator conductances measured in these experiments were consistent with those obtained in other experiments with heat pipes of similar surface geometry using the same or similar working fluids.

Loehrke, R. I.↗

Results of convective heating tests of a longitudinal gap on the Rockwell flat plate model (15-0, insert 7) in the NASA/Ames Research Center

Results are presented which were obtained from tests in a hypersonic wind tunnel to determine aerodynamic heating rates in a gap running parallel or slightly askew to the flow direction. The model used was a flat plate instrumented in thin-skin sections with chromelconstantan thermocouples. Heating rate profiles lengthwise along and down into the gap were obtained, and additional data were obtained from a total temperature probe and rake fabricated during the test to investigate an apparent aerodynamic cooling trend in the gap. Model variables were width, depth, length, and orientation of the gap relative to the flow direction. The tests were conducted at Mach 5.1 and Reynolds numbers per foot of 500,000, 1,000,000, and 2,000,000.

Quan, M.↗

An eddy-viscosity treatment of the unsteady turbulent boundary layer on a flat plate in an expansion tube

An analysis is presented for the relaxation of a turbulent boundary layer on a semiinfinite flat plate after passage of a shock wave and a trailing driver gas-driven gas interface. The problem has special application to expansion tube flows. The flow-governing equations have been transformed into the Lamcrocco variables. The numerical results indicate that a fully turbulent boundary layer relaxes faster to the final steady-state values of heat transfer and skin-friction than a fully laminar boundary layer.

Gupta, R. N.↗

Impact response of graphite-epoxy flat laminates using projectiles that simulate aircraft engine encounters

An investigation of the response of a graphite-epoxy material to foreign object impact was made by impacting spherical projectiles of gelatin, ice, and steel normally on flat panels. The observed damage was classified as transverse (stress wave delamination and cracking), penetrative, or structural (gross failure): the minimum, or threshold, velocity to cause each class of damage was established as a function of projectile characteristics. Steel projectiles had the lowest transverse damage threshold, followed by gelatin and ice. Making use of the threshold velocities and assuming that the normal component of velocity produces the damage in nonnormal impacts, a set of impact angles and velocities was established for each projectile material which would result in damage to composite fan blades. Analysis of the operating parameters of a typical turbine fan blade shows that small steel projectiles are most likely to cause delamination and penetration damage to unprotected graphite-epoxy composite fan blades.

Preston, J. L., Jr.↗

Flat-plate /vapor-chamber/ heat pipes

This paper discusses the design, fabrication and testing of heat pipes constructed in the form of flat-plate panels. The test panels were constructed of copper with methyl alcohol as the working fluid. Capillary grooves etched on the internal surfaces provided evaporation and condensation heat-transfer coefficients on the order of 1600 Btu/hr-sq ft-deg F. Two panels were launched on board a sounding rocket; the payload reached an altitude of 140 miles, and zero gravity was achieved for almost six minutes. The panel with working fluid inside demonstrated a heat input flux of 2.5 watts/sq cm, with only a 3 to 5 C temperature difference throughout the entire panel.

Fleischman, G. L.↗

Testing flat-conductor cable

Report describes characteristics of type of FCC which consists of three AWG No. 12 flat copper conductors laminated between two films of polyethylene terephthalate (Mylar) insulation with self-extinguishing polyester adhesive.

Loggins, R. W.↗

Effect of slot width on transition and noise attenuation of a flat sound shield in a Mach 6 wind tunnel

An experimental and theoretical study of a sound shield concept to attenuate the noise radiated into the test section from the turbulent boundary layer on the walls of wind tunnels was conducted. The model investigated was planar with a sharp flat plate leading edge faired into an array of rods aligned nearly parallel to the local flow. For a ratio of gap diameter to rod diameter of 0.16, the flow was laminar over the entire model at a maximum local length Reynolds number of 14 million. A 45% reduction in the tunnel free stream root mean square pressure level was measured within the shielded region for this gap width when the boundary layers on the rods were laminar. Smaller ratios of gap diameter to rod diameter resulted in substantial reductions in the transition Reynolds number, and in a 40% pressure reduction.

Stainback, P. C.↗

Standard performance tests of collectors of solar thermal energy: A selectively coated, flat-plate copper collector with one transparent cover and a tube-to-tube spacing of 3-7/8 inches

Basic test results are given of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes, and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.

Source record↗

Standardized performance tests of collectors of solar thermal energy: A selectively coated, flat-plate copper collector with one transparent cover and a tube-to-tube spacing of 5 5/8 inches

This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.

Source record↗