Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “element”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Finite deformation cohesive polygonal finite elements for modeling pervasive fracture

In this work, we introduce a framework for modeling dynamic fracture problems using cohesive polygonal finite elements. Random polygonal meshes provide a robust, efficient method for generating an unbiased network of fracture surfaces. Further, these meshes have more facets per element than standard triangle or quadrilateral meshes, providing more possible facets per element to insert cohesive surfaces. This property of polygonal meshes is advantageous for the modeling of pervasive fracture. We use both Wachspress and maximum entropy shape functions to form a finite element basis over the polygons. Fracture surfaces are captured through dynamically inserted cohesive zone elements at facets between the polygons in the mesh. Contact is enforced through a penalty method that is applied to both closed cohesive surfaces and general interpenetration of two polygonal elements. Finally, several numerical examples are presented that illustrate the capabilities of the method and demonstrate convergence of solutions.

97 MATHEMATICS AND COMPUTING↗

Rapid in situ nutrient element distribution in plants and soils using laser-induced breakdown spectroscopy ($\mathrm{LIBS}$)

The aim of this study is to develop and test the applicability of a rapid in situ plant chemistry profiling technique to determine elemental composition of small-volume plant and soil samples obtained from a woody bioenergy crop species, Populus trichocarpa. Expanding the research tools available to characterize the nutrient element correlations among plant tissue types and soil depths is a critical need in the path of understanding productivity and adaptation of plants to variations in external abiotic and biotic factors and developing sustainable perennial bioenergy crops that are co-optimized for biomass valorization aboveground and carbon sequestration belowground. Several plant root, stem, and soil samples were tested using laser-induced breakdown spectroscopy (LIBS) to evaluate the presence and distribution of nutrient elements. Samples were tested as collected and after being dried and cross sectioned to evaluate the effectiveness of using LIBS for in situ analysis on plant samples. The collected LIBS spectra show the elemental peaks were the same in both the as collected and prepared samples for roots and stems. Qualitative amounts of elements such as H, C, N, O, Li, Na, Mg, K, Ca, Fe, Al, and Si were able to be identified rapidly in raw samples. Here in this report we demonstrate suitability of LIBS in obtaining rapid, in situ, elemental distribution in plant and soil samples, utilizing only small sample volumes and minimal sample preparation. This demonstration opens up a new rapid phenotyping avenue necessary to fill the asymmetrical knowledge gaps in belowground performance of plant systems.

59 BASIC BIOLOGICAL SCIENCES↗

Oxygen Effects and Selective Oxidation of Group IV Alloying Additions in Group V-Based Refractory Multi-principal Element Alloys

Refractory multi-principal element alloys (RMPEAs) hold significant potential for advancing ultra-high-temperature technologies due to their remarkable strength retention under these conditions. However, the beneficial effects of alloying on microstructural evolution and mechanical properties are often obscured by the presence of interstitial alloying elements. The intricate interactions between substitutional alloying elements of Groups IV, V, and VI and interstitial content, whether intentional or incidental, remain poorly understood. In this study, we investigate the impact of dissolved oxygen on the microstructural evolution and stability of RMPEAs primarily composed of Group V elements, Nb and V, along with Group IV elements Ti, Zr, and Hf. We show that the strong affinity of oxygen for Group IV elements Zr and Hf leads to the internal precipitation of oxides during heat treatment, which competes with the homogenization of the as-cast dendritic microstructure. Here, we demonstrate that careful control and design of oxygen content and Group IV alloying additions are essential to minimize micro-segregation and prevent the detrimental precipitation of internal oxides. To address these challenges, we propose employing non-equilibrium solidification calculations to predict and optimize as-cast solidification structures, thereby reducing the reliance on homogenization processes.

Alloy design↗

A Review of Methodology Development for Controlling Loss of Alloying Elements During the Electroslag Remelting Process

Electroslag remelting (ESR) is an advanced secondary refining technology for the production of clean, fully dense, and homogeneous castings of steels and alloys by removal of undesirable elements and nonmetallic inclusions. However, because of some potential reactions between reactive elements, i.e., Al and Ti, in liquid metal and oxygen as well as weak oxides, such as FeO and SiO{sub 2}, in slag during the ESR process, it is impossible to hold those oxidative elements within specification or to maintain them uniformly from the bottom to top of the resultant ingot. According to a literature survey, recent fundamental research on the oxidation behaviors of Al and Ti in nickel-based alloy by ESR-type slag is scarce. Therefore, summarizing previous knowledge on the controlling loss reactive elements during ESR of Fe- and Ni-based alloys in view of thermodynamics and kinetics is in order to increase the basic understanding of the reaction mechanism between those elements and oxygen and weak oxides in the slag, which can guide the development of a new remelting technique that retards the oxidation of Al and Ti in Inconel 718 alloys during the ESR process. The presence of impurity elements, such as oxygen and sulfur, can also deteriorate the mechanical properties of metal products. Therefore, the inter-related literature about desulfurization during the ESR process is also reviewed in this article.

36 MATERIALS SCIENCE↗

Sectoral and growth rate control on elemental uptake by individual calcite crystals

Heterogeneous distribution of trace elements (impurities) within individual calcite crystals is a phenomenon commonly observed in natural and laboratory systems. Changes in thermodynamic intensive parameters (mostly chemical potential and temperature) cannot always explain the inhomogeneous impurity patterns in calcite crystals and it has been suggested that growth rate and crystallographic orientation may exert strong effects on elemental incorporation into calcite. In addition, there are a number of experimental studies on micro-scale element (E) distribution between non-equivalent pairs of calcite vicinal faces (known as sectoral zoning); however, the variability of partition coefficients (e.g., K E = (E/Ca) calcite /(E/Ca) fluid ) within individual crystals remains undetermined. In this study, we have extended the work on elemental distribution between crystal sectors to evaluation of partition coefficients of trace and minor elements (Li, B, Mg, and Sr) in calcite crystal faces (10–14) and (01-12), whose growth rates were assessed. Growth entrapment model (GEM) and lattice strain theory were applied to explain K E heterogeneity by varying near-surface diffusivity of Mg and Sr and by varying surface enrichment factor for Li, B, Mg, and Sr. Decoupling of sectoral and growth rate effects reveals that sectoral zoning plays a key role in elemental distribution. More specifically, K Li and K B vary by more than one order of magnitude and K Mg varies by a factor of two within individual crystal faces. Strontium sectoral distribution is different from those of Li, B, and Mg and K Sr varies by up to a factor of two. Finally, these behaviors likely reflect different mechanisms of incorporation of Li, B, Mg, and Sr into calcite.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Galerkin formulations of isogeometric shell analysis: Alleviating locking with Greville quadratures and higher-order elements

Here we propose new quadrature schemes that asymptotically require only four in-plane points for Reissner–Mindlin shell elements and nine in-plane points for Kirchhoff–Love shell elements in B-spline and NURBS-based isogeometric shell analysis, independent of the polynomial degree p of the elements. The quadrature points are Greville abscissae associated with pth-order B-spline basis functions whose continuities depend on the specific Galerkin formulations, and the quadrature weights are calculated by solving a linear moment fitting problem in each parametric direction. The proposed shell element formulations are shown through numerical studies to be rank sufficient and to be free of spurious modes. The studies reveal comparable accuracy, in terms of both displacement and stress, compared with fully integrated spline-based shell elements, while at the same time reducing storage and computational cost associated with forming element stiffness and mass matrices and force vectors. The high accuracy with low computational cost makes the proposed quadratures along with higher-order spline bases, in particular polynomial orders, p = 5 and 6, good choices for alleviating membrane and shear locking in shells.

42 ENGINEERING↗

Distribution of chemical elements in soils and stream sediments in the area of abandoned Sb–As–Tl Allchar mine, Republic of Macedonia

The aim of this study was to investigate the distribution of some toxic elements in topsoil and subsoil, focusing on the identification of natural and anthropogenic element sources in the small region of rare As–Sb–Tl mineralization outcrop and abandoned mine Allchar known for the highest natural concentration of Tl in soil worldwide. The samples of soil and sediments after total digestion were analyzed by inductively coupled plasma–mass spectrometry (ICP–MS) and inductively coupled plasma–atomic emission spectrometry (ICP–AES). Factor analysis (FA) was used to identify and characterize element associations. Six associations of elements were determined by the method of multivariate statistics: Rb–Ta–K–Nb–Ga–Sn–Ba–Bi–Li–Be–(La–Eu)–Hf–Zr–Zn–In–Pd–Ag–Pt–Mg; Tl–As–Sb–Hg; Te–S–Ag–Pt–Al–Sc–(Gd–Lu)–Y; Fe–Cu–V–Ge–Co–In; Pd–Zr–Hf–W–Be and Ni–Mn–Co–Cr–Mg. The purpose of the assessment was to determine the nature and extent of potential contamination as well as to broadly assess possible impacts to human health and the environment. The results from the analysis of the collected samples in the vicinity of the mine revealed that As and Tl elements have the highest median values. Higher median values for Sb are obviously as a result of the past mining activities and as a result of area surface phenomena in the past. - Highlights: • Soil and river sediments were analyzed from Sb–As–Tl Allchar locality. • An increased content of certain toxic elements for environment was determined. • Highest As and Tl contents are obtained in the close vicinity of Allchar mine. • River sediments portray 160 times higher content of Sb than EU values. • The results classify Allchar as probably the highest natural Tl-deposit worldwide.

54 ENVIRONMENTAL SCIENCES↗

Relationship between domestic smoking and metals and rare earth elements concentration in indoor PM2.5

Highlights: • Tobacco smoke releases heavy metals (HM) and REE in indoor dwellings. • Elemental content in indoor PM{sub 2.5} was measured in smoking and non smoking dwellings. • Extracted and mineralized fractions of elements were evaluated by ICP-MS. • Indoor smoke was associated with increase of specific elemental fractions in PM{sub 2.5}. • Increased levels of HM and REE are associated with respiratory symptoms in children. Cigarette smoke is the main source of indoor chemical and toxic elements. Cadmium (Cd), Thallium (Tl), Lead (Pb) and Antimony (Sb) are important contributors to smoke-related health risks. Data on the association between Rare Earth Elements (REE) Cerium (Ce) and Lanthanum (La) and domestic smoking are scanty. To evaluate the relationship between cigarette smoke, indoor levels of PM{sub 2.5} and heavy metals, 73 children were investigated by parental questionnaire and skin prick tests. The houses of residence of 41 “cases” and 32 “controls” (children with and without respiratory symptoms, respectively) were evaluated by 48-h PM{sub 2.5} indoor/outdoor monitoring. PM{sub 2.5} mass concentration was determined by gravimetry; the extracted and mineralized fractions of elements (As, Cd, Ce, La, Mn, Pb, Sb, Sr, Tl) were evaluated by ICP-MS. PM{sub 2.5} and Ce, La, Cd, and Tl indoor concentrations were higher in smoker dwellings. When corrected for confounding factors, PM{sub 2.5}, Ce, La, Cd, and Tl were associated with more likely presence of respiratory symptoms in adolescents. We found that: i) indoor smoking is associated with increased levels of PM{sub 2.5}, Ce, La, Cd, and Tl and ii) the latter with increased presence of respiratory symptoms in children.

54 ENVIRONMENTAL SCIENCES↗

Investigation of breakaway corrosion observed during oxide growth in pure and low alloying element content Zr exposed in water at 360°C

The addition of small concentrations of alloying elements to pure zirconium can prevent nuclear fuel cladding material from undergoing unstable oxide growth in aqueous environments at light water reactor operating temperatures. The role of alloying elements in stabilizing the oxide growth is examined in this paper, to better understand the oxide growth stabilization mechanism. To this end, a set of initial, short-duration corrosion experiments were performed, followed by oxide layer characterization. Specifically, ten model Zr alloys were selected to test the effect of small alloying additions on the alloy corrosion rate and corrosion breakaway. Additionally, these alloys were corrosion tested in pure water in an autoclave at 360°C for up to 70 days. The alloys included crystal bar Zr, sponge Zr, and model alloys with small concentrations of Sn, Fe, and Cr. After testing, the alloys were characterized using scanning electron microscopy (SEM) and synchrotron µ-X-ray fluorescence (µXRF) to study how the structure of the oxide and alloying element distribution related to unstable oxide growth. Initial results in the 360°C water environment showed breakaway oxidation may be caused by unstable oxide growth due to heterogeneous distribution of the alloying elements. Heterogeneous distribution of alloying elements was correlated to the occurrence of unstable oxide growth (either nodule-like, grain boundary penetration, or differential grain-to-grain growth). It is possible that this heterogeneity, made possible by low alloying element content, can cause breakaway corrosion, but further study is warranted.

36 MATERIALS SCIENCE↗

Element-resolved Kikuchi pattern measurements of non-centrosymmetric materials

Angle-resolved electron Rutherford backscattering (ERBS) measurements using an electrostatic electron energy analyser can provide unique access to element-resolved crystallographic information. We present Kikuchi pattern measurements of the non-centrosymmetric crystal GaP, separately resolving the contributions of electrons backscattered from Ga and P. In comparison to element-integrated measurements like in the method of electron backscatter diffraction (EBSD), the effect of the absence of a proper 4-fold rotation axis in the point group of GaP can be sensed with a much higher visibility via the element-resolved Ga to P intensity ratio. These element-resolved measurements make it possible to experimentally attribute the previously observed point-group dependent effect in element-integrated EBSD measurements to the larger contribution of electrons scattered from Ga compared to P. - Highlights: •Element specific Kikuchi patterns are presented for GaP. •Absence of a proper four-fold rotation axis is demonstrated. •Ga and P intensity variations after 90 degree rotation have opposite phase. •The asymmetry in the total intensity distribution resembles that of Ga.

36 MATERIALS SCIENCE↗

Simulation of crack induced nonlinear elasticity using the combined finite-discrete element method

Numerical simulation of nonlinear elastic wave propagation in solids with cracks is indispensable for decoding the complicated mechanisms associated with the nonlinear ultrasonic techniques in NonDestructive Testing (NDT). Here, we introduce a two-dimensional implementation of the combined finitediscrete element method (FDEM), which merges the finite element method (FEM) and the discrete element method (DEM), to explicitly simulate the crack induced nonlinear elasticity in solids with both horizontal and inclined cracks. In the FDEM model, the solid is discretized into finite elements to capture the wave propagation in the bulk material, and the finite elements along the two sides of the crack also behave as discrete elements to track the normal and tangential interactions between crack surfaces. The simulation results show that for cracked models, nonlinear elasticity is generated only when the excitation amplitude is large enough to trigger the contact between crack surfaces, and the nonlinear behavior is very sensitive to the crack surface contact. The simulations reveal the influence of normal and tangential contact on the nonlinear elasticity generation. Moreover, the results demonstrate the capabilities of FDEM for decoding the causality of nonlinear elasticity in cracked solid and its potential to assist in Non-Destructive Testing (NDT).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The width of the lateral element of the synaptonemal complex is determined by a multilayered organization of its components

The synaptonemal complex (SC) is a proteinaceous structure that holds the homologous chromosomes in close proximity while they exchange genetic material in a process known as meiotic recombination. This meiotic recombination leads to genetic variability in sexually reproducing organisms. The ultrastructure of the SC is studied by electron microscopy and it is observed as a tripartite structure. Two lateral elements (LE) separated by a central region (CR) confer its classical tripartite organization. The LEs are the anchoring platform for the replicated homologous chromosomes to properly exchange genetic material with one another. An accurate assembly of the LE is indispensable for the proper completion of meiosis. Ultrastructural studies suggested that the LE is organized as a multilayered unit. However, no validation of this model has been previously provided. In this ultrastructural study, by using mice with different genetic backgrounds that affect the LE width, we provide further evidence that support a multilayered organization of the LE. Additionally, we provide data suggesting additional roles of the different cohesin complex components in the structure of the LEs of the SC. - Highlights: • The lateral element of the synaptonemal complex is a multilayered structure. • The width of the lateral element in synaptonemal complex-null mice is different. • Two cohesin complex cores plus one axial element form a wild-type lateral element. • The layers of the lateral element can be analyzed in different null mice models.

60 APPLIED LIFE SCIENCES↗

Solar abundance ratios of the iron-peak elements in the Perseus cluster

The metal abundance of the hot plasma that permeates galaxy clusters represents the accumulation of heavy elements produced by billions of supernovae1. Therefore, X-ray spectroscopy of the intracluster medium provides an opportunity to investigate the nature of supernova explosions integrated over cosmic time. In particular, the abundance of the iron-peak elements (chromium, manganese, iron and nickel) is key to understanding how the progenitors of typical type Ia supernovae evolve and explode2–6. Recent X-ray studies of the intracluster medium found that the abundance ratios of these elements differ substantially from those seen in the Sun, suggesting differences between the nature of type Ia supernovae in the clusters and in the Milky Way. However, because the K-shell transition lines of chromium and manganese are weak and those of iron and nickel are very close in photon energy, highresolution spectroscopy is required for an accurate determination of the abundances of these elements. Here in this paper we report observations of the Perseus cluster, with statistically significant detections of the resonance emission from chromium, manganese and nickel. Our measurements, combined with the latest atomic models, reveal that these elements have near-solar abundance ratios with respect to iron, in contrast to previous claims. Comparison between our results and modern nucleosynthesis calculations disfavours the hypothesis that type Ia supernova progenitors are exclusively white dwarfs with masses well below the Chandrasekhar limit (about 1.4 times the mass of the Sun). The observed abundance pattern of the iron-peak elements can be explained by taking into account a combination of near- and sub-Chandrasekhar-mass type Ia supernova systems, adding to the mounting evidence that both progenitor types make a substantial contribution to cosmic chemical enrichment.

79 ASTRONOMY AND ASTROPHYSICS↗

Additive roles of antiferromagnetically coupled elements in the magnetic proximity effect in the GdFeCo/Pt system

Abstract Interfacial magnetic interactions between different elements are the origin of various spin-transport phenomena in multi-elemental magnetic systems. We investigate the coupling between the magnetic moments of the rare-earth, transition-metal, and heavy-metal elements across the interface in a GdFeCo/Pt thin film, an archetype system to investigate ferrimagnetic spintronics. The Pt magnetic moments induced by the antiferromagnetically aligned FeCo and Gd moments are measured using element-resolved x-ray measurements. It is revealed that the proximity-induced Pt magnetic moments are always aligned parallel to the FeCo magnetic moments, even below the ferrimagnetic compensation temperature where FeCo has a smaller moment than Gd. This is understood by a theoretical model showing distinct effects of the rare-earth Gd 4 f and transition-metal FeCo 3 d magnetic moments on the Pt electronic states. In particular, the Gd and FeCo work in-phase to align the Pt moment in the same direction, despite their antiferromagnetic configuration. The unexpected additive roles of the two antiferromagnetically coupled elements exemplify the importance of detailed interactions among the constituent elements in understanding magnetic and spintronic properties of thin film systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superior spatial resolution in confocal X-ray techniques using collimating channel array optics: elemental mapping and speciation in archaeological human bone

Confocal X-ray fluorescence imaging (CXFI) and confocal X-ray absorption spectroscopy (CXAS) respectively enable the study of three dimensionally resolved localization and speciation of elements. Applied to a thick sample, essentially any volume element of interest within the X-ray fluorescence escape depth can be examined without the need for physical thin sectioning. To date, X-ray confocal detection generally has employed a polycapillary optic in front of the detector to collect fluorescence from the probe volume formed at the intersection of its focus with the incident microfocus beam. This work demonstrates the capability of a novel Collimating Channel Array (CCA) optic in providing an improved and essentially energy independent depth resolution approaching 2 μm. By presenting a comparison of elemental maps of archaeological bone collected without confocal detection, and with polycapillary- and CCA-based confocal detection, this study highlights the strengths and limitations of each mode. Unlike the polycapillary, the CCA shows similar spatial resolution in maps for both low (Ca) and high (Pb and Sr) energy X-ray fluorescence, thus illustrating the energy independent nature of the CCA optic resolution. While superior spatial resolution is demonstrated for all of these elements, the most significant improvement is observed for Ca, demonstrating the advantage of employing the CCA optic in examining light elements. In addition to CXFI, this configuration also enables the collection of Pb L3 CXAS data from micro-volumes with dimensions comparable to bone microstructures of interest. Our CXAS result, which represents the first CCA-based biological CXAS, demonstrates the ability of CCA optics to collect site specific spectroscopic information. The demonstrated combination of site-specific elemental localization and speciation data will be useful in diverse fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring the working range of automated standard dilution analysis of nutrient elements in foods by inductively coupled plasma optical emission spectrometry

Inductively coupled plasma optical emission spectrometry (ICP-OES) is an important tool for measuring nutrient elements in food. ICP-OES methods typically determine analytical concentrations using external standard calibration but can be susceptible to matrix effects. The method of standard additions does not suffer from matrix effects but is time consuming and labor intensive. Automated standard dilution analysis (SDA) allows for online matrix matched calibration without preparing individual standard additions for each sample matrix. This approach may solve both time and matrix issues and has been described in the literature as an attractive alternative to standard additions. The working range of the method for nutrient elements, however, is an understudied feature of SDA that may be a potential drawback to routine analysis of foods. We evaluated automated SDA performance through the analysis of 10 reference materials and four fortified (i.e., spiked) foods spanning the AOAC food triangle. We evaluated the working range, accuracy, and precision for analyses of nutrient elements in foods. Accepted accuracy (80–120% recovery) was achieved for 10 nutrient elements, Ca, Cu, Fe, K, Mg, Mn, Na, P, S, and Zn, when the analytical solution concentration to standard concentration ratio was less than 10. This equates to a working range for each element spanning at least two orders of magnitude. Removing outliers, Z scores (n = 95) ranged from –1.8 to 0.88, and the average recovery (n = 85) from fortification experiments was 97 ± 12% (2σ). Therefore, automated SDA applied to ICP-OES may be used for nutrient elemental analyses in samples with difficult matrices such as foods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Portable rare-earth element analyzer using pyroelectric crystal

We report a portable rare-earth element analyzer with a palm-top size chamber including the electron source of a pyroelectric crystal and the sample stage utilizing cathodoluminescence (CL) phenomenon. The portable rare-earth element analyzer utilizing CL phenomenon is the smallest reported so far. The portable rare-earth element analyzer detected the rare-earth elements Dy, Tb, Er, and Sm of ppm order in zircon, which were not detected by scanning electron microscopy-energy dispersive X-ray spectroscopy analysis. We also performed an elemental mapping of rare-earth elements by capturing a CL image using CCD camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Concentration of trace elements on branded cigarette in Malaysia

Tobacco is a plant that is used as a recreational drug since the beginning of its use by the Native Americans. Now with the development of the tobacco industry, smoking has become a norm for the public in Malaysia. Trace elements in plants are mostly due to the uptake processes from the soils into the roots of the plants. The concentration of the elements may also be influenced by the elements contained in the water and also fertilizers. This paper aim to analyze the concentration of the trace elements contained in the branded cigarettes sold in Malaysia by utilizing the neutron activation analysis. The tobaccos were taken out from the cigarettes. The collected samples were air dried and passed through 2 mm sieve. Instrumental Neutron Activation Analysis (NAA) has been used for the determination of trace elements. Samples were activated in the Nuclear Malaysia Triga Mark II reactor with a neutron flux of 2.0 x 10{sup 12} n cm{sup -2} s{sup -1}. The samples then were analyzed using ORTEC Gamma Spectrometer a co-axial n-type HPGe detector with resolution of 2.0 keV at 1332 keV and relative efficiency of 20%. The data obtained could help in assessing the concentration of the trace elements that complying with the standard limitation dose proposed by World Health Organization (WHO)

07 ISOTOPE AND RADIATION SOURCES↗