Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

BSM Studies Using Long-baseline Neutrino Experiment

The standard model of particle physics cannot account for the various physical phenomena present in nature. For instance, the visible matter constitutes only about 5$\%$ of the whole universe, and the remaining content is believed to be dark matter and dark energy. Unfortunately, the standard model does not provide us with a good candidate for dark matter. The leading dark matter candidate is weakly interacting massive particles (WIMPs) having a mass of less than 1 GeV. We will require a broad, fixed target neutrino experiment to probe the vast parameter space for the light-dark matter particle. NOvA is a high luminosity long-baseline fixed-target accelerator neutrino experiment at Fermilab. It can provide a potentially exciting probe in searching for signatures of DM scattering with electrons in its near detectors. We aim to search for the MeV-scale dark matter particles that might be generated within the NuMI beam and produce detectable electron scattering signals in the NOvA Near Detector. Not only in the dark matter sector, the standard model cannot explain the neutrino mass and mixings. The neutrino propagation in matter can be affected by non-standard interactions (NSI), which is beyond the standard model phenomena. The constraints coming from the NSI sectors can affect the standard oscillation parameters like atmospheric mixing angle $\theta_{23}$ and CP-phase $\delta_{CP}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for inelastic boosted dark matter with the ICARUS detector at the Gran Sasso Underground National Laboratory

We present the result of a search for inelastic boosted dark matter using the data corresponding to an exposure of 0.13 kton · year , collected by the ICARUS T-600 detector during its 2012–2013 operational period at the INFN Gran Sasso Underground National Laboratory. The benchmark boosted dark matter model features a multiparticle dark sector with a U ( 1 ) ′ gauge boson, the dark photon. The kinetic mixing of the dark photon with the Standard Model photon allows for a portal between the dark sector and the visible sector. The inelastic boosted dark matter interaction occurs when a dark matter particle inelastically scatters with an electron in the ICARUS detector, producing an outgoing, heavier dark sector state which subsequently decays back down to the dark matter particle, emitting a dark photon. The dark photon subsequently couples to a Standard Model photon through kinetic mixing. The Standard Model photon then converts to an electron-positron pair in the detector. This interaction process provides a distinct experimental signature that consists of a recoil electron from the primary interaction and an associated electron-positron pair from the secondary vertex. After analyzing 4,134 triggered events, the search results in zero observed events. Exclusion limits are set in the dark photon mass and coupling ( m X , ε ) parameter space for several selected optimal boosted dark matter mass sets and cover previously unexplored parameter space. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Testing of a Line Driver With Configurable Pre-Emphasis on Lossy Transmission Lines

Rare-event physics experiments such as the Deep Underground Neutrino Experiment (DUNE) or the next Enriched Xenon Observatory (nEXO) experiment search for rare, low-energy events, detected by sensitive detectors immersed in a cryogenic noble liquid (e.g., liquid argon or xenon). Readout electronics used within such detectors must consume minimal power while operating reliably in cryogenic environments. Furthermore, in the case of nEXO, maximizing the radiopurity of the environment is vital to minimize background noise, thus placing strict limits on the volume of dielectric materials, leading to high-loss data cables spanning distances up to 12 m. Such cables cause high attenuation and intersymbol interference (ISI), resulting in a high bit-error rate (BER). These issues were addressed by developing an integrated line driver with configurable pre-emphasis in a 65-nm CMOS process. The pre-emphasis parameters can be programmed to minimize BER for specific cables and data rates under power constraints. Here, the driver was tested at both room and cryogenic temperatures. In both cases, the output BER was found to be strongly correlated with the pre-emphasis settings. Furthermore, analysis and simulation showed that adapting the pre-emphasis settings based on the incoming bit sequence can further improve performance with minimal changes to the current solution.

47 OTHER INSTRUMENTATION↗

Proceedings of the Third Infrared Detector Technology Workshop

This volume consists of 37 papers which summarize results presented at the Third Infrared Detector Technology Workshop, held February 7-9, 1989, at Ames Research Center. The workshop focused on infrared (IR) detector, detector array, and cryogenic electronic technologies relevant to low-background space astronomy. Papers on discrete IR detectors, cryogenic readouts, extrinsic and intrinsic IR arrays, and recent results from ground-based observations with integrated arrays were given. Recent developments in the second-generation Hubble Space Telescope (HST) infrared spectrometer and in detectors and arrays for the European Space Agency's Infrared Space Observatory (ISO) are also included, as are status reports on the Space Infrared Telescope Facility (SIRTF) and the Stratospheric Observatory for Infrared Astronomy (SOFIA) projects.

Mccreight, Craig R.↗

Precise test of lepton flavour universality in W -boson decays into muons and electrons in pp collisions at $\sqrt{s}$ =13 TeV with the ATLAS detector

The ratio of branching ratios of the $W$ boson to muons and electrons, $R^{μ/e}_{W}$ = $\mathcal{B}$($W$ → $μν$)/$\mathcal{B}$($W$ → $eν$), has been measured using 140 fb -1 of pp collision data at $\sqrt{s}$ = 13 TeV collected with the ATLAS detector at the LHC, probing the universality of lepton couplings. The ratio is obtained from measurements of the $t\overline{t}$ production cross section in the $ee$, $eμ$ and $μμ$ dilepton final states. To reduce systematic uncertainties, it is normalised by the square root of the corresponding ratio $R^{μμ/ee}_{Z}$ for the Z boson measured in inclusive $Z$ → $ee$ and $Z$ → $μμ$ events. By using the precise value of $R^{μμ/ee}_{Z}$ determined from $e^+$ $e^-$ colliders, the ratio $R^{μ/e}_{W}$ is determined to be $R^{μ/e}_{W}$ = 0.9995 ± 0.0022 (stat) ± 0.0036 (syst) ± 0.0014 (ext). The three uncertainties correspond to data statistics, experimental systematics and the external measurement of $R^{μμ/ee}_{Z}$, giving a total uncertainty of 0.0045, and confirming the Standard Model assumption of lepton flavour universality in $W$ boson decays at the 0.5% level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)↗

Signal formation and sharing in AC-LGADs using the ALTIROC 0 front-end chip

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. However, finding a technology capable of fulfilling such aspiration proved to be an arduous task. Among other silicon-based candidates, the Low-Gain Avalanche Diode (LGAD) has already shown excellent timing performances but proved to be unsuitable for fine pixelization. Therefore, the AC-coupled LGAD (AC-LGAD) approach was introduced to provide high resolution in both time and space, making it a promising candidate for future 4D detectors. However, appropriate readout electronics must be developed to match the sensor's fast-time and fine-pitch capabilities. This is currently a major technological challenge. Here, we test AC-LGAD prototypes read out by the fast-time ASIC ALTIROC 0, originally developed for the readout of DC-coupled LGADs for the ATLAS experiment at the High Luminosity-LHC. Signal generated by either betas from a 90 Sr source or a focused infra-red laser were analyzed. This paper details the first successful readout of an AC-LGAD sensor using a readout chip. This result will pave the way for the design and construction of a new generation of AC-LGAD-based 4D detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MPGD Trackers in the ePIC Detector at the EIC

The future Electron-Ion Collider (EIC) at Brookhaven National Laboratory will collide polarized electrons with polarized proton/ions. The electron ? Proton / Ion Collider (ePIC) Experiment is the EIC general-purpose detector aiming at delivering the full physics program of the EIC. This unique environment imposes stringent requirements on the tracking system needed for the measurement of the scattered electron and charged particles produced in the collisions at the EIC. The central tracker of the ePIC detector has silicon layers for tracking and vertexing based on MAPS technology, which are complemented by large Micro-Pattern Gaseous Detector (MPGD) trackers in the barrel and in both the electron and hadron end cap regions. The MPGD layers provide fast timing (10-20 ns) and additional hit points (150 µm) for pattern recognition during track finding. Two MPGD technologies are used in ePIC central trackers: cylindrical Micromegas for the barrel inner tracker and planar thin-gap GEM-µRWELL hybrid detector for the barrel outer tracker and the end cap disks. In this talk, we will introduce these two technologies in the context of ePIC and we will discuss the ongoing R&D efforts to address the requirements. Finally, we will discuss the plans and timeline for the production and testing and commissioning of the MPGD trackers for the installation in the ePIC detector.

Gnanvo, Kondo↗

Revealing Phase Heterogeneity in Vertically Aligned Nanocomposites via Plan-View Electron Energy Loss Spectroscopy

Hydrogen utilization in clean energy technologies is challenged by limited storage and transport within materials, owing to the complex hydrogen kinetics at interfaces [1]. Understanding these interfacial mechanisms at the nanoscale is crucial for developing improved materials for hydrogen applications, particularly proton-conducting fuel cells (PCFCs). Vertically aligned nanocomposites (VANs) grown by pulsed laser deposition (PLD) offer a unique platform for investigating the interfacial effects on hydrogen transport due to their well-defined interfaces parallel to the direction of charge transport [2-4]. To investigate hydrogen transport, the two phases within the VANs were chosen as BaZr 0.9 Y 0.1 O 3-x (BZY), a known proton conductor, and Pr 0.1 Ce 0.9 O 2-x (PCO), a mixed ionic-electronic conductor [5]. This PCO-BZY VANs architecture allows the investigation of how the interface between a proton conductor and a mixed conductor influences hydrogen transport. However, because of the small size of hydrogen, it is difficult to discern the nature of its interactions with interfaces from bulk measurements at the macroscale, thus necessitating nanoscale measurements [6]. Electron energy loss spectroscopy (EELS) allows for nanometer-resolution probing of the local atomic structure and chemistry at the BZY/PCO interface. In this study, plan-view analysis of PCO-BZY VANs films was employed to characterize the structure and phase distribution of the VANs and investigate the interface between the nanostructures. The films were imaged using scanning electron microscopy (SEM) in the Hitachi S-4800 SEM, collecting secondary electron images using mixed upper and lower detectors. Then, plan-view transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) EELS were employed using a JEOL ARM300 microscope operated at 300kV with a Gatan K3 GIF Continuum detector to study the distribution of the BZY and PCO phases through the film. As a result, spectrum images were acquired at a dispersion of 0.18eV per channel and denoised afterward by principal component analysis (PCA) method.

Griffin, Elizabeth [Northwestern University, Evans↗

Light Dark Matter Analysis Using NO$\nu$A Near Detector

Dark matter (DM) is believed to account for 85$\%$ of the matter content of the Universe. The leading dark matter candidate is the WIMP (weakly interacting massive particles). Light dark matter (LDM) refers to WIMP candidates with a mass of less than 1 GeV. The concept of LDM has been developed in order to explain the 511 keV $\gamma$-rays from the galactic bulge, as observed by the INTEGRAL satellite. There are a lot of candidates for light DM, and these candidates span a wide range of potential masses and couplings to the visible sector. Probing the vast parameter space of light-dark matter requires a correspondingly broad experimental program that can include neutrino fixed target experiments. NOvA is a high luminosity long-baseline fixed-target accelerator neutrino experiment at Fermilab that can provide a potentially interesting probe in searching for signatures of DM scattering with electrons in its near detectors. We aim to search for the MeV-scale dark matter particles that might be generated within the NuMI beam and produce detectable electron scattering signals in NOvA Near Detector. In this talk, we present our analysis of the single electron events using a simulated sample and show the sensitivity of the NOvA experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of deeply virtual Compton scattering at the future electron-ion collider

This study presents the impact of future measurements of deeply virtual Compton scattering (DVCS) with the ePIC detector at the electron-ion collider (EIC), currently under construction at Brookhaven National Laboratory. The considered process is sensitive to generalized parton distributions (GPDs), the understanding of which is a cornerstone of the EIC physics program. Our study marks a milestone in the preparation of DVCS measurements at EIC and provides a reference point for future analyses. In addition to presenting distributions of basic kinematic variables obtained with the latest ePIC design and simulation software, we examine the impact of future measurements on the understanding of nucleon tomography and DVCS Compton form factors, which are directly linked to GPDs. We also assess the impact of radiative corrections and background contribution arising from exclusive π 0 production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quiet-time increases of low-energy electrons - The Jovian origin

With a detector on board the OGO-5 satellite, the flux and energy spectrum of electrons in the 10-200-MeV range has been continuously measured from 1968 to 1971. Sudden increases in intensity by factors of up to 300% have been observed during solar quiet times. It is shown that these increases are nearly independent of energy up to about 25 MeV and disappear rapidly above that energy. The frequency of the increases peaks every 13 months at a time following the crossing by earth of the interplanetary magnetic-field line which passes the vicinity of the planet Jupiter. Most of the increases occur in a period of 3 to 5 months following this crossing and often appear to be 27 days apart. A Jovian origin for these electrons and their mode of transport to the inner solar system are discussed.

Lheureux, J.↗

Earth's magnetic field as a radiator to detect cosmic ray electrons of energy greater than 10 to the 12th eV

Synchrotron emission by a high-energy electron in the geomagnetic field and its dependence upon different arrival directions over Palestine, Texas, where major balloon-borne experiments are being conducted, is studied. The dependence of detector response on the arrival direction of electron, the different criteria which are adopted to identify an electron event, the area of the detector, and the energy of the electron are discussed. An omnidirectional circular detector is used to examine whether it is possible to determine the energy of an electron without knowing its arrival direction. The collecting power of a detector is estimated as a function of the energy of electrons for different detector areas with different selection criteria, and this information is used to calculate the event rates expected by folding in the energy spectrum of cosmic ray electrons to show the viability of detecting cosmic ray electrons at energies greater than a few TeV.

Balasubrahmanyan, V. K.↗

Preliminary design report, Large Space Telescope OTA/SI Phase B study: High speed area photometer

A photometer is examined which combines several features from separate instruments into a single package. The design presented has both point and area photometry capability with provision for inserting filters to provide spectral discrimination. The electronics provide for photon counting mode for the point detectors and both photon counting and analog modes for the area detector. The area detector also serves as a target locating device for the point detectors. Topics discussed include: (1) electronic equipment requirements, (2) optical properties, (3) structural housing for the instrument, (4) motors and other mechanical components, (5) ground support equipment, and (6) environment control for the instrument. Engineering drawings and block diagrams are shown.

Source record↗

Optimization of the light detection system of the ICARUS detector

The Short Baseline Neutrino (SBN) Program at Fermilab is designed to investigate short-baseline neutrino oscillations and test the hypothesis of sterile neutrinos, motivated by several experimental anomalies observed over the past decades. Within this program, the ICARUS experiment plays a key role. It employs the world’s largest Liquid Argon Time Projection Chamber (LArTPC) and serves as the farthest and most sensitive SBN detector for studying muon and electron neutrino oscillations. A crucial subsystem of the ICARUS detector is the Light Detection System (LDS), which captures the prompt scintillation light produced by neutrino interactions in the 600-ton active liquid Argon volume. This system provides precise timing information that is essential for event reconstruction, the trigger system, and cosmic background rejection. The LDS is composed of 360 Hamamatsu R5912-MOD 8-inch photomultiplier tubes (PMTs), operating under cryogenic conditions ($\sim 87 \ K$) inside the detector’s cryostats. During the detector’s operation at FNAL, a degradation in PMT gain has been observed, attributed to aging under low-temperature conditions. In collaboration with ICARUS teams from INFN Pavia and Catania, I developed an experimental setup to study the temperature-dependent behavior of the PMTs, performing gain measurements both at room temperature and down to $-70°C$ using a climatic chamber at INFN Catania. The results indicate that while the PMTs maintain stable gain at room temperature, a significant and permanent gain reduction occurs at low temperatures. Although $-70°C$ is still warmer than liquid Argon temperatures, the findings clearly demonstrate a gain-dependent performance degradation. The thesis also discusses mitigation strategies implemented in the ICARUS detector to address this issue and presents a simplified model to describe and simulate the observed behavior.

Saia, Clara [Catania U.] (ORCID:0009000464102417)↗

Electron and photon reconstruction and identification with the CMS experiment at the CERN LHC

The performance is presented of the reconstruction and identification algorithms for electrons and photons with the CMS experiment at the LHC. The reported results are based on proton-proton collision data collected at a center-of-mass energy of 13 TeV and recorded in 2016–2018, corresponding to an integrated luminosity of 136 fb^-1. Results obtained from lead-lead collision data collected at √(sNN)=5.02 TeV are also presented. Innovative techniques are used to reconstruct the electron and photon signals in the detector and to optimize the energy resolution. Events with electrons and photons in the final state are used to measure the energy resolution and energy scale uncertainty in the recorded events. The measured energy resolution for electrons produced in Z boson decays in proton-proton collision data ranges from 2 to 5%, depending on electron pseudorapidity and energy loss through bremsstrahlung in the detector material. The energy scale in the same range of energies is measured with an uncertainty smaller than 0.1 (0.3)% in the barrel (endcap) region in proton-proton collisions and better than 1 (3)% in the barrel (endcap) region in heavy ion collisions. The timing resolution for electrons from Z boson decays with the full 2016–2018 proton-proton collision data set is measured to be 200 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Timepix4 analog front-end design: Lessons learnt on fundamental limits to noise and time resolution in highly segmented hybrid pixel detectors

This manuscript describes the optimization of the front-end readout electronics for high granularity hybrid pixel detectors. The theoretical study aims at minimizing the noise and jitter. The model presented here is validated with both circuit post layout simulations and measurements on the Timepix4 Application Specific Integrated Circuit (ASIC). The analog front-end circuit and the procedure to optimize the dimensions of the main transistors are described with detail. The Timepix4 is the most recent ASIC designed in the framework of the Medipix4 Collaboration. It was manufactured in 65nm CMOS process, and consists of a four side buttable matrix of 448 × 512 pixels with 55µm pitch. The analog front-end has a gain of ~36mV/ke - when configured in High Gain Mode, and ~20mV/ke - when configured in Low Gain Mode. The Equivalent Noise Charge (ENC) is ~68e - rms and ~80e - rms in High Gain Mode and in Low Gain Mode respectively. In event driven mode the incoming hits can be time stamped within a ~ 200ps time bin and the chip can deal with a maximum flux of ~ 3.6MHzmm –2 s –1 . In photon counting mode, the chip can deal with up to ~ 5GHzmm –2 s –1 . The routine designed to optimize the Timepix4 front-end is then used to analyze the performance limits in terms of jitter and noise for Charge Sensitive Amplifiers in pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Suppression of Penning discharges between the KATRIN spectrometers

Abstract The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)-neutrino mass with a sensitivity of 0.2eV/c $$^2$$ 2 by precisely measuring the endpoint region of the tritium $$\beta $$ β -decay spectrum. It uses a tandem of electrostatic spectrometers working as magnetic adiabatic collimation combined with an electrostatic (MAC-E) filters. In the space between the pre-spectrometer and the main spectrometer, creating a Penning trap is unavoidable when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create additional background electrons and endanger the spectrometer and detector section downstream. To counteract this problem, “electron catchers” were installed in the beamline inside the magnet bore between the two spectrometers. These catchers can be moved across the magnetic-flux tube and intercept on a sub-ms time scale the stored electrons along their magnetron motion paths. In this paper, we report on the design and the successful commissioning of the electron catchers and present results on their efficiency in reducing the experimental background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗