Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Instrument development continues in Oak Ridge

Peer review panels composed of 80 external scientists recently visited Oak Ridge National Laboratory (ORNL) to review almost 700 proposals for experiments on 23 instruments at the Spallation Neutron Source (SNS) and High Flux Isotope Reactor (HFIR). These were proposed for the time period from January-June 2012. About 40% of the proposals were approved for beam time and 20% were placed on an alternate list if time becomes available. The Hybrid Spectrometer HYSPEC at SNS began its commissioning in September 2011. HYSPEC is otpimized for studying low energy dynamics in single-crystal samples using a broad variety of sample environments, and is equipped with a polarization analysis capability. It is expected to be available for users on a limited basis in the second half of 2012. The detector tank of CORELLI has been installed on beamline 9 at SNS. Now that the tank is in place, banks of neutron detectors and boron carbide shielding will be installed around the interior. CORELLI is optimized to probe complex disorder in crystalline materials through diffuse scattering from single-crystal samples. It will begin commissioning in 2014. CORELLI is one of four instruments being developed under the SING II (SNS Instruments Next Generation II) project. The others are the Macromolecular Neutron Diffractometer (MANDI), the Vibrational Spectrometer (VISION, scheduled to begin commissioning in 2012), and the Time of Flight Ultra Small Angle Neutron Scattering Instrument (TOF-USANS). The single crystal neutron diffractometer IMAGINE, was deliverd to HFIR in October 2011. Preliminary testing has been carried out. IMAGINE will provide atomic resolution information on chemical, organic, metallo-organic and protein single crystals that will enable their chemical, physical and biological structure and function to be understood. This instrument will benefit scientists with interests in pharmaceuticals, minerals and other inorganic crystals, small molecules, molecular organo-metallic crystals and metal-organic frameworks (MOFs) molecular crystal structures. The quasi-Laue geometry, combined with a large solid angle detector, will enable rapid data collection from crystals with volume < 1mm{sup 1} and unit cell < 100 {angstrom}. Construction and installation of the optical system is in progress. Commissioning is expected to start in April 2012.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PySAGES: flexible, advanced sampling methods accelerated with GPUs

Abstract Molecular simulations are an important tool for research in physics, chemistry, and biology. The capabilities of simulations can be greatly expanded by providing access to advanced sampling methods and techniques that permit calculation of the relevant underlying free energy landscapes. In this sense, software that can be seamlessly adapted to a broad range of complex systems is essential. Building on past efforts to provide open-source community-supported software for advanced sampling, we introduce PySAGES, a Python implementation of the Software Suite for Advanced General Ensemble Simulations (SSAGES) that provides full GPU support for massively parallel applications of enhanced sampling methods such as adaptive biasing forces, harmonic bias, or forward flux sampling in the context of molecular dynamics simulations. By providing an intuitive interface that facilitates the management of a system’s configuration, the inclusion of new collective variables, and the implementation of sophisticated free energy-based sampling methods, the PySAGES library serves as a general platform for the development and implementation of emerging simulation techniques. The capabilities, core features, and computational performance of this tool are demonstrated with clear and concise examples pertaining to different classes of molecular systems. We anticipate that PySAGES will provide the scientific community with a robust and easily accessible platform to accelerate simulations, improve sampling, and enable facile estimation of free energies for a wide range of materials and processes.

Chemistry↗

Two-color interferometry and shadowgraphy characterization of an orthogonal double-pulse laser ablation

Orthogonal double pulse laser ablation on aluminum target at atmospheric pressure was studied by time-resolved optical emission spectroscopy, shadowgraphy and two-color interferometry. Studies were realized as a function of the distance from the first pulse plasma induced in air to the sample surface. The evolution of the electron and neutral particles densities were determined by two-color interferometry. Line intensification mechanisms are discussed based on the interferometry results and the plumes interaction dynamics. It was found that the sample heating by the preablation pulse could contribute to the observed emission enhancement.

36 MATERIALS SCIENCE↗

Molecular Aspects of Transport in Thin Films of Controlled Architecture

Our laboratory focuses on developing spatially localized chemistries which can produce structures of controlled architecture on the supermolecular length scale -- structures which allow us to control the motion of molecular species with high spatial resolution, ultimately on nanometer length scales. Specifically, nanocapillary array membranes (NCAMs) contain an array of nanometer diameter pores connecting vertically separated microfluidic channels. NCAMs can manipulate samples with sub-femtoliter characteristic volumes and attomole sample amounts and are opening the field of chemical analysis of mass-limited samples, because they are capable of digital control of fluid switching down to sub-attoliter volumes; extension of analytical “unit operations” down to sub-femtomole sample sizes; and exerting spatiotemporal control over fluid mixing to enable studies of reaction dynamics. Digital flow switching mediated by nanocapillary array membranes can be controlled by bias, ionic strength, or pore diameter and is being studied by observing the temporal characteristics of transport across a single nanopore in thin PMMA membranes. The control of flow via nanopore surface characteristics, charge density and functional group presentation, is being studied by coupled conductivity and laser-induced fluorescence (LIF) measurements. Reactive mixing experiments previously established low millisecond mixing times for NCAM-mediated fluid transfer, and this has been exploited to demonstrate capture of mass-limited target species by Au colloids. Voltage and thermally-activated polymer switches have been developed for active control of transport in NCAMs. Thermally-switchable and size-selective transport was achieved by grafting poly(N-isopropylacrylamide) brushes onto the exterior surface of a Au-coated polycarbonate track-etched membrane, while the voltage-gated properties of poly(hydroxyethylmethacrylate) were characterized dynamically. Electrophoretic separations have been coupled to analyte sampling both by LIF and mass spectrometry. Detection of electrophoresis separation products by electrospray mass spectrometry was achieved through direct interfacing to an electrospray mass spectrometer. Pb(II) interactions with the DNAzyme have been realized in an NCAM-coupled integrated microfluidic structure allowing cation separations to be coupled to molecular beacon detection motifs for the determination of Pb(II) in an electroplating sludge reference material. By changing the DNAzyme to select for other compounds of interest, it is possible to incorporate multiple sensing systems within a single device, thereby achieving great flexibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prior data assisted compressed sensing: A novel MR imaging strategy for real time tracking of lung tumors

Purpose: Hybrid radiotherapy-MRI devices promise real time tracking of moving tumors to focus the radiation portals to the tumor during irradiation. This approach will benefit from the increased temporal resolution of MRI's data acquisition and reconstruction. In this work, the authors propose a novel spatial-temporal compressed sensing (CS) imaging strategy for the real time MRI–-prior data assisted compressed sensing (PDACS), which aims to improve the image quality of the conventional CS without significantly increasing reconstruction times. Methods: Conventional 2D CS requires a random sampling of partial k-space data, as well as an iterative reconstruction that simultaneously enforces the image's sparsity in a transform domain as well as maintains the fidelity to the acquired k-space. PDACS method requires the additional acquisition of the prior data, and for reconstruction, it additionally enforces fidelity to the prior k-space domain similar to viewsharing. In this work, the authors evaluated the proposed PDACS method by comparing its results to those obtained from the 2D CS and viewsharing methods when performed individually. All three methods are used to reconstruct images from lung cancer patients whose tumors move and who are likely to benefit from lung tumor tracking. The patients are scanned, using a 3T MRI, under free breathing using the fully sampled k-space with 2D dynamic bSSFP sequence in a sagittal plane containing lung tumor. These images form a reference set for the evaluation of the partial k-space methods. To create partial k-space, the fully sampled k-space is retrospectively undersampled to obtain a range of acquisition acceleration factors, and reconstructed with 2D-CS, PDACS, and viewshare methods. For evaluation, metrics assessing global image artifacts as well as tumor contour shape fidelity are determined from the reconstructed images. These analyses are performed both for the original 3T images and those at a simulated 0.5T equivalent noise level. Results: In the 3.0T images, the PDACS strategy is shown to give superior results compared to viewshare and conventional 2D CS using all metrics. The 2D-CS tends to perform better than viewshare at the low acceleration factors, while the opposite is true at the high acceleration factors. At simulated 0.5T images, PDACS method performs only marginally better than the viewsharing method, both of which are superior compared to 2D CS. The PDACS image reconstruction time (0.3 s/image) is similar to that of the conventional 2D CS. Conclusions: The PDACS method can potentially improve the real time tracking of moving tumors by significantly increasing MRI's data acquisition speeds. In 3T images, the PDACS method does provide a benefit over the other two methods in terms of both the overall image quality and the ability to accurately and automatically contour the tumor shape. MRI's data acquisition may be accelerated using the simpler viewsharing strategy at the lower, 0.5T magnetic field, as the marginal benefit of the PDACS method may not justify its additional reconstruction times.

60 APPLIED LIFE SCIENCES↗

An algorithm to correct saturated mass spectrometry ion abundances for enhanced quantitation and mass accuracy in omic studies

The mass accuracy and peak intensity of ions detected by mass spectrometry (MS) measurements are essential to facilitate compound identification and quantitation. However, high concentration species can easily cause problems if their ion intensities reach beyond the limits of the detection system, leading to distorted and non-ideal detector response (e.g. saturation), and largely precluding the calculation of accurate m/z and intensity values. Here we present an open source computational method to correct peaks above a defined intensity (saturated) threshold determined by the MS instrumentation such as the analog-to-digital converters or time-to-digital converters used in conjunction with time-of-flight MS. In this method, the isotopic envelope for each observed ion above the saturation threshold is compared to its expected theoretical isotopic distribution. The most intense isotopic peak for which saturation does not occur is then utilized to re-calculate the precursor m/z and correct the intensity, resulting in both higher mass accuracy and greater dynamic range. The benefits of this approach were evaluated with proteomic and lipidomic datasets of varying complexities. After correcting the high concentration species, reduced mass errors and enhanced dynamic range were observed for both simple and complex omic samples. Specifically, the mass error dropped by more than 50% in most cases with highly saturated species and dynamic range increased by 1-2 orders of magnitude for peptides in a blood serum sample.

Environmental Molecular Sciences Laboratory↗

An instrument for in situ time-resolved X-ray imaging and diffraction of laser powder bed fusion additive manufacturing processes

In situ X-ray-based measurements of the laser powder bed fusion (LPBF) additive manufacturing process produce unique data for model validation and improved process understanding. Synchrotron X-ray imaging and diffraction provide high resolution, bulk sensitive information with sufficient sampling rates to probe melt pool dynamics as well as phase and microstructure evolution. Here, we describe a laboratory-scale LPBF test bed designed to accommodate diffraction and imaging experiments at a synchrotron X-ray source during LPBF operation. We also present experimental results using Ti-6Al-4V, a widely used aerospace alloy, as a model system. Both imaging and diffraction experiments were carried out at the Stanford Synchrotron Radiation Lightsource. Melt pool dynamics were imaged at frame rates up to 4 kHz with a ~1.1 μm effective pixel size and revealed the formation of keyhole pores along the melt track due to vapor recoil forces. Diffraction experiments at sampling rates of 1 kHz captured phase evolution and lattice contraction during the rapid cooling present in LPBF within a ~50 × 100 μm area. In conclusion, we also discuss the utility of these measurements for model validation and process improvement.

36 MATERIALS SCIENCE↗

Microstructural evolution during dynamic deformation of cubic metals: copper

Shockwave shape can influence dynamic damage evolution. Features such as rise time, pulse duration, peak shock pressure, pull back, and release rate are influenced as wave shape changes. However, their individual influence on dynamic damage evolution is not well understood. Specifically, changing from a square to triangular or Taylor wave loading profile can alter the release kinetics from peak shock pressure and the volume of material sampled during release. This creates a spatial influence. In high purity metals, because damage is often linked to boundaries within the microstructure (grain or twin), changing the volume of material sampled during release, can have a drastic influence on dynamic damage evolution as the number of boundaries or defects sampled is altered. In this study, model-driven dynamic experiments have been conducted on eu with four different grain sizes to examine, for a given shockwave shape, how the spatial effect of boundary distribution influences dynamic damage evolution. Both two and three dimensional damage characterization techniques have been utilized. This study shows the critical influence of spatial effects, in this case boundary density, on dynamic damage evolution. As the boundary density decreases, the damage evolution transitions from nucleation controlled to growth controlled. It also shows that specific boundaries, those with high Schmid factor orientations on either side, maybe a necessary condition for void formation.

36 MATERIALS SCIENCE↗

Effect of cation distribution on the magnetic and hyperfine behaviour of nanocrystalline Co doped Ni–Zn ferrite (Ni{sub 0.4}Zn{sub 0.4}Co{sub 0.2}Fe{sub 2}O{sub 4})

Highlights: • Cation distribution in tetrahedral and octahedral sites of spinel Ni{sub 0.4}Zn{sub 0.4}Co{sub 0.2}Fe{sub 2}O{sub 4}. • Structural analysis of observed X-ray diffraction pattern using Rietveld method. • Study of hyperfine behaviour using Mössbauer spectroscopy. • Static and dynamic magnetic measurements. • Correlation of cation distributions obtained from Rietveld analysis with the results of magnetic and Mössbauer effect measurements. - Abstract: Nanoparticles of Ni{sub 0.4}Zn{sub 0.4}Co{sub 0.2}Fe{sub 2}O{sub 4} are prepared by a simple co-precipitation method. The as dried sample is heat treated at 400, 500, 600, 700 and 800 °C to obtain different sizes of nanoparticles. The crystallographic phase of the samples is confirmed analyzing observed X-ray diffraction (XRD) by Rietveld method. Hyperfine parameters of the samples are derived from room temperature (RT) Mössbauer spectra of the samples. Magnetic properties of the samples are investigated by static and dynamic hysteresis loops. Different magneto-crystalline parameters are calculated from the variation of magnetization with temperature (M–T curve) under zero field cooled (ZFC) and field cooled (FC) conditions of the as dried sample. The cation distribution estimated from Rietveld analysis are correlated with the results of magnetic and Mössbauer effect measurements. The observed high value of saturation magnetization (72.7 emu/g at RT) of the sample annealed at 800 °C would be interesting for applications in different electromagnetic devices.

36 MATERIALS SCIENCE↗

Supervised learning and the finite-temperature string method for computing committor functions and reaction rates

A central object in the computational studies of rare events is the committor function. Though costly to compute, the committor function encodes complete mechanistic information of the processes involving rare events, including reaction rates and transition-state ensembles. Under the framework of transition path theory, Rotskoff et al. [Proceedings of the 2nd Mathematical and Scientific Machine Learning Conference, Proceedings of Machine Learning Research (PLMR, 2022), Vol. 145, pp. 757–780] proposes an algorithm where a feedback loop couples a neural network that models the committor function with importance sampling, mainly umbrella sampling, which collects data needed for adaptive training. Here, in this work, we show additional modifications are needed to improve the accuracy of the algorithm. The first modification adds elements of supervised learning, which allows the neural network to improve its prediction by fitting to sample-mean estimates of committor values obtained from short molecular dynamics trajectories. The second modification replaces the committor-based umbrella sampling with the finite-temperature string (FTS) method, which enables homogeneous sampling in regions where transition pathways are located. We test our modifications on low-dimensional systems with non-convex potential energy where reference solutions can be found via analytical or finite element methods, and show how combining supervised learning and the FTS method yields accurate computation of committor functions and reaction rates. We also provide an error analysis for algorithms that use the FTS method, using which reaction rates can be accurately estimated during training with a small number of samples. The methods are then applied to a molecular system in which no reference solution is known, where accurate computations of committor functions and reaction rates can still be obtained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ Chemical Monitoring and Imaging of Contents within Microfluidic Devices Having a Porous Membrane Wall Using Liquid Microjunction Surface Sampling Probe Mass Spectrometry

The ability to observe dynamic chemical processes (e.g., signaling, transport, etc.) in vivo or in situ using nondestructive chemical imaging opens a new door to understanding the complex dynamics of developing biological systems. With the advent of “biology-on-a-chip” devices has come the ability to monitor dynamic chemical processes in a controlled environment, using these engineered habitats to capture key features of natural systems while allowing visual observation of system development. Having the capability to spatially and temporally map the chemical signals within these devices may yield new insights into the forces that drive biosystem development. Here, a porous membrane sealed microfluidic device was designed to allow normal microfluidic operation while enabling continuous, location specific sampling and chemical characterization by liquid microjunction surface sampling probe mass spectrometry (LMJ-SSP MS). LMJ-SSP was used to extract fluids with nL-to-μL/min flow rates directly from selected areas of the microfluidic device without negatively impacting the device function. These extracts were subsequently characterized using MS. This technique was used to acquire MS images of the entirety of several multi-input microfluidic devices having different degrees of fluid mixing. LMJ-SSP MS imaging visualized the spatial distribution of chemical components within the microfluidic channels and could visualize chemical reactions occurring in the device. These microfluidic devices with a porous membrane wall are wholly compatible with the construction of biology-on-a-chip devices. This ultimately would enable correlation of biosystem physical structure with an evolving chemical environment

47 OTHER INSTRUMENTATION↗

Pairing a Global Optimization Algorithm with EXAFS to Characterize Lanthanide Structure in Solution

Ensemble-average sampling of structures from ab initio molecular dynamics (AIMD) simulations can be used to predict theoretical extended X-ray absorption fine structure (EXAFS) signals that closely match experimental spectra. However, AIMD simulations are time-consuming and resource-intensive, particularly for solvated lanthanide ions, which often form multiple nonrigid geometries with high coordination numbers. Here, to accelerate the characterization of lanthanide structures in solution, we employed the Northwest Potential Energy Surface Search Engine (NWPEsSe), an adaptive-learning global optimization algorithm, to efficiently screen first-shell structures. As case studies, we examine two systems: Eu(NO 3 ) 3 dissolved in acetonitrile with a terpyridine ligand (terpyNO 2 ), and Nd(NO 3 ) 3 dissolved in acetonitrile. The theoretical spectra for structures identified by NWPEsSe were compared to both experimental and AIMD-derived EXAFS spectra. The NWPEsSe algorithm successfully identified the proper solvation structure for both Eu(NO 3 ) 3 (terpyNO 2 ) and Nd(NO 3 )(acetonitrile) 3 , with the calculated EXAFS signals closely matching the experimental spectra for the Eu-ligand complex and showing good similarity for the Nd salt; the better agreement with the ligand-containing structure is attributed to a less dynamic coordination environment due to the rigid ligand. The key advantage of the global optimization algorithm lies in its ability to sample the coordination environment across the potential energy surface and reduce the time required to identify structures from generally a month to within a week. Additionally, this approach is versatile and can be adapted to characterize main-group metal complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structured illumination with thermal imaging (SI-TI): A dynamically reconfigurable metrology for parallelized thermal transport characterization

The recent push for the “materials by design” paradigm requires synergistic integration of scalable computation, synthesis, and characterization. Among these, techniques for efficient measurement of thermal transport can be a bottleneck limiting the experimental database size, especially for diverse materials with a range of roughness, porosity, and anisotropy. Traditional contact thermal measurements have challenges with throughput and the lack of spatially resolvable property mapping, while non-contact pump-probe laser methods generally need mirror smooth sample surfaces and also require serial raster scanning to achieve property mapping. Here, we present structured illumination with thermal imaging (SI-TI), a new thermal characterization tool based on parallelized all-optical heating and thermometry. Experiments on representative dense and porous bulk materials as well as a 3D printed thermoelectric thick film (~50 μm) demonstrate that SI-TI (1) enables paralleled measurement of multiple regions and samples without raster scanning; (2) can dynamically adjust the heating pattern purely in software, to optimize the measurement sensitivity in different directions for anisotropic materials; and (3) can tolerate rough (~3 μm) and scratched sample surfaces. Here, this work highlights a new avenue in adaptivity and throughput for thermal characterization of diverse materials.

42 ENGINEERING↗

Improving Seasonal Forecast Using Probabilistic Deep Learning

The path toward realizing the potential of seasonal forecasting and its socioeconomic benefits relies on improving general circulation model (GCM) based dynamical forecast systems. To improve dynamical seasonal forecasts, it is crucial to set up forecast benchmarks, and clarify forecast limitations posed by model initialization errors, formulation deficiencies, and internal climate variability. With huge costs in generating large forecast ensembles, and limited observations for forecast verification, the seasonal forecast benchmarking and diagnosing task proves challenging. Here, we develop a probabilistic deep learning-based statistical forecast methodology, drawing on a wealth of climate simulations to enhance seasonal forecast capability and forecast diagnosis. By explicitly modeling the internal climate variability and GCM formulation differences, the proposed Conditional Generative Forecasting (CGF) methodology enables bypassing crucial barriers in dynamical forecast, and offers a top-down viewpoint to examine how complicated GCMs encode the seasonal predictability information. We apply the CGF methodology for global seasonal forecast of precipitation and 2 m air temperature, based on a unique data set consisting 52,201 years of climate simulation. Results show that the CGF methodology can faithfully represent the seasonal predictability information encoded in GCMs. We successfully apply this learned relationship in real-world seasonal forecast, achieving competitive performance compared to dynamical forecasts. Using this CGF as benchmark, we reveal the impact of insufficient forecast spread sampling that limits the skill of the considered dynamical forecast system. Finally, we introduce different strategies for composing ensembles using the CGF methodology, highlighting the potential for leveraging the strengths of multiple GCMs to achieve advantgeous seasonal forecast.

54 ENVIRONMENTAL SCIENCES↗

Project Dinos I: A joint lensing–dynamics constraint on the deviation from the power law in the mass profile of massive ellipticals

The mass distribution in massive elliptical galaxies encodes their evolutionary history, thus providing an avenue to constrain the baryonic astrophysics in their evolution. The power-law assumption for the radial mass profile in ellipticals has been sufficient to describe several observables to the noise level, including strong lensing and stellar dynamics. In this paper, we quantitatively constrained any deviation, or the lack thereof, from the power-law mass profile in massive ellipticals through joint lensing–dynamics analysis of a large statistical sample with 77 galaxy–galaxy lens systems. We performed an improved and uniform lens modelling of these systems from archival Hubble Space Telescope imaging using the automated lens modelling pipeline dolphin. We combined the lens model posteriors with the stellar dynamics to constrain the deviation from the power law after accounting for the line-of-sight lensing effects, a first for analyses on galaxy–galaxy lenses. We find that the Sloan Lens ACS Survey lens galaxies with a mean redshift of 0.2 are consistent with the power-law profile within 1.1σ (2.8σ) and the Strong Lensing Legacy Survey lens galaxies with a mean redshift of 0.6 are consistent within 0.8σ (2.1σ), for a spatially constant (Osipkov–Merritt) stellar anisotropy profile. We adopted the spatially constant anisotropy profile as our baseline choice based on previous dynamical observables of local ellipticals. However, spatially resolved stellar kinematics of lens galaxies are necessary to differentiate between the two anisotropy models. Future studies will use our lens models to constrain the mass distribution individually in the dark matter and baryonic components.

79 ASTRONOMY AND ASTROPHYSICS↗

Adaptive Dynamic Event Tree in RAVEN code

RAVEN is a software tool that is focused on performing statistical analysis of stochastic dynamic systems. RAVEN has been designed in a high modular and pluggable way in order to enable easy integration of different programming languages (i.e., C++, Python) and coupling with other applications (system codes). Among the several capabilities currently present in RAVEN, there are five different sampling strategies: Monte Carlo, Latin Hyper Cube, Grid, Adaptive and Dynamic Event Tree (DET) sampling methodologies. The scope of this paper is to present a new sampling approach, currently under definition and implementation: an evolution of the DET me

Dynamic Event Tree↗