Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drops”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Nucleation of Quantized Vortices from Rotating Superfluid Drops

The long-term goal of this project is to study the nucleation of quantized vortices in helium II by investigating the behavior of rotating droplets of helium II in a reduced gravity environment. The objective of this ground-based research grant was to develop new experimental techniques to aid in accomplishing that goal. The development of an electrostatic levitator for superfluid helium, described below, and the successful suspension of charged superfluid drops in modest electric fields was the primary focus of this work. Other key technologies of general low temperature use were developed and are also discussed.

Donnelly, Russell J.↗

Marangoni Effects of a Drop in an Extensional Flow: The Role of Surfactant Physical Chemistry

While the changes in stresses caused by surfactant adsorption on non-deforming interfaces have been fairly well established, prior to this work, there were few studies addressing how surfactants alter stresses on strongly deforming interfaces. We chose the model problem of a drop in a uniaxial extensional flow to study these stress conditions To model surfactant effects at fluid interfaces, a proper description of the dependence of the surface tension on surface concentration, the surface equation of state, is required. We have adopted a surface equation of state that accounts for the maximum coverage limit; that is, because surfactants have a finite cross sectional area, there is an upper bound to the amount of surfactant that can adsorb in a monolayer. The surface tension reduces strongly only when this maximum coverage is approached. Since the Marangoni stresses go as the derivative of the surface equation of state times the surface concentration gradient, the non-linear equation of state determines both the effect of surfactants in the normal stress jump, (which is balanced by the product of the mean curvature of the interface times the surface tension), and the tangential stress jump, which is balanced by Marangoni stresses. First, the effects of surface coverage and intermolecular interactions among surfactants which drive aggregation of surfactants in the interface were studied. (see Pawar and Stebe, Physics of Fluids).

Stebe, Kathleen J.↗

Study of the Variability in the Rain Drop Size Distribution Over a 2.3. km Path

In an effort to study the drop size distribution (DSD) a state-of-the-art instrument arrangement was deployed on Wallops Island, VA. The instrumentation consisted of a 2.3-km multi-frequency microwave link, three impact disdrometers, and a network of optical and tipping bucket raingauges. A dual-frequency inversion technique was implemented with the fink measurements of attenuations at 25 GHz and 38 GHz to estimate the path-average DSD. Concurrently, an X-band, dual-polarization radar, located in the vicinity, collected polarization and reflectively measurements over the link path. The evaluation of the estimates and measurements generated some preliminary results.

Rincon, Rafael F.↗

A Three-Parameter Inversion of the Drop Size Distribution Using NASA/TRMM Microwave Link Data

Attenuation measurements at 25 and 38 GHz performed with the NASA/TRMM Microwave Link provide information about the drop size distribution (DSD) along the propagation path. Additional path-average measurements along the Link path, such as a third attenuation measurement or the rain rate from well-calibrated raingauges, can provide further DSD information. This paper explores an inversion procedure for determining simultaneously three parameters of a gamma DSD by using three measurements. Also, some preliminary results obtained using Link data are presented.

Rincon, Rafael F.↗

Quasi-Uniform High Speed Foam Crush Testing Using a Guided Drop Mass Impact

A relatively simple method for measuring the dynamic crush response of foam materials at various loading rates is described. The method utilizes a drop mass impact configuration with mass and impact velocity selected such that the crush speed remains approximately uniform during the entire sample crushing event. Instrumentation, data acquisition, and data processing techniques are presented, and limitations of the test method are discussed. The objective of the test method is to produce input data for dynamic finite element modeling involving crash and energy absorption characteristics of foam materials.

Jones, Lisa E.↗

Crash Simulation of a Vertical Drop Test of a Commuter-Class Aircraft

A finite element model of an ATR42-300 commuter-class aircraft was developed and a crash simulation was executed. Analytical predictions were correlated with data obtained from a 30-ft/s (9.14-m/s) vertical drop test of the aircraft. The purpose of the test was to evaluate the structural response of the aircraft when subjected to a severe, but survivable, impact. The aircraft was configured with seats, dummies, luggage, and other ballast. The wings were filled with 8,700 lb. (3,946 kg) of water to represent the fuel. The finite element model, which consisted of 57,643 nodes and 62,979 elements, was developed from direct measurements of the airframe geometry. The seats, dummies, luggage, fuel, and other ballast were represented using concentrated masses. The model was executed in LS-DYNA, a commercial code for performing explicit transient dynamic simulations. Predictions of structural deformation and selected time-history responses were generated. The simulation was successfully validated through extensive test-analysis correlation.

Jackson, Karen E.↗

An Examination of the Impact of Drizzle Drops on Satellite-Retrieved Effective Particle Sizes

In general, cloud effective droplet radii are remotely sensed in the near-infrared using the assumption of a monomodal droplet size distribution. It has been observed in many instances, especially in relatively pristine marine environments, that cloud effective droplet radii derived from satellite data often exceed 15 m or more. Comparisons of remotely sensed and in situ retrievals indicate that the former often overestimates the latter in clouds with drizzle-size droplets. To gain a better understanding of this discrepancy, this paper performs a theoretical and empirical evaluation of the impact of drizzle drops on the derived effective radius.

Minnis, Patrick↗

Noninvasive estimation of transmitral pressure drop across the normal mitral valve in humans: importance of convective and inertial forces during left ventricular filling

OBJECTIVES: We hypothesized that color M-mode (CMM) images could be used to solve the Euler equation, yielding regional pressure gradients along the scanline, which could then be integrated to yield the unsteady Bernoulli equation and estimate noninvasively both the convective and inertial components of the transmitral pressure difference. BACKGROUND: Pulsed and continuous wave Doppler velocity measurements are routinely used clinically to assess severity of stenotic and regurgitant valves. However, only the convective component of the pressure gradient is measured, thereby neglecting the contribution of inertial forces, which may be significant, particularly for nonstenotic valves. Color M-mode provides a spatiotemporal representation of flow across the mitral valve. METHODS: In eight patients undergoing coronary artery bypass grafting, high-fidelity left atrial and ventricular pressure measurements were obtained synchronously with transmitral CMM digital recordings. The instantaneous diastolic transmitral pressure difference was computed from the M-mode spatiotemporal velocity distribution using the unsteady flow form of the Bernoulli equation and was compared to the catheter measurements. RESULTS: From 56 beats in 16 hemodynamic stages, inclusion of the inertial term ([deltapI]max = 1.78+/-1.30 mm Hg) in the noninvasive pressure difference calculation significantly increased the temporal correlation with catheter-based measurement (r = 0.35+/-0.24 vs. 0.81+/-0.15, p< 0.0001). It also allowed an accurate approximation of the peak pressure difference ([deltapc+I]max = 0.95 [delta(p)cathh]max + 0.24, r = 0.96, p<0.001, error = 0.08+/-0.54 mm Hg). CONCLUSIONS: Inertial forces are significant components of the maximal pressure drop across the normal mitral valve. These can be accurately estimated noninvasively using CMM recordings of transmitral flow, which should improve the understanding of diastolic filling and function of the heart.

Non-NASA Center↗

Investigation in Simulated Vertical Descent of the Characteristics of a Cargo-Dropping Device having Extensible Rotating Blades

The characteristics of a cargo-dropping device having extensible rotating blades as load-carrying surfaces have been studied in simulated vertical descent in the Langley 20-foot free-spinning tunnel. The investigation included tests to determine the variation in vertical sinking speed with load. A study of the blade characteristics and of the test results indicated a method of dynamically balancing the blades to permit proper functioning of the device.

Stone, Ralph W., Jr.↗