Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distribution network”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Toward a Virtual Solar Observatory: Starting Before the Petabytes Fall

NASA is currently engaged in the study phase of a modest effort to establish a Virtual Solar Observatory (VSO). The VSO would serve ground- and space-based solar physics data sets from a distributed network of archives through a small number of interfaces to the scientific community. The basis of this approach, as of all planned virtual observatories, is the translation of metadata from the various sources via source-specific dictionaries so the user will not have to distinguish among keyword usages. A single Web interface should give access to all the distributed data. We present the current status of the VSO, its initial scope, and its relation to the European EGSO effort.

Gurman, J. B.↗

Online Model-Free DER Dispatch Via Adaptive Voltage Sensitivity Estimation and Chance Constrained Programming

This paper proposes an online data-driven distributed energy resource management system (DERMS) for distribution system optimal DER dispatch as well as voltage regulation. Here, the key innovation is to leverage the Local Sensitivity Factor (LSF) for transforming the DER control into a computationally efficient linear programming (LP) problem. By taking real-time measurements, the estimation of LSF eliminates the need for an accurate distribution system model as well as full nodal load information, which is difficult to achieve in practice. A robust recursive least squares method is also developed to ensure the robust estimation of LSF, which is initialized using reasonable values from model-derived LSFs. This allows the system to adapt to changing operational conditions effectively. A scenario-based, chance-constrained framework is further employed to ensure voltage remains within acceptable limits in the presence of measurement and estimation uncertainties. Test results on a real-world, 759-node distribution network located in western Colorado, U.S., validate the effectiveness and robustness of the proposed control approach and demonstrate its superior performance as compared to alternative methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Precise Point Positioning for the Efficient and Robust Analysis of GPS Data From Large Networks

Networks of dozens to hundreds of permanently operating precision Global Positioning System (GPS) receivers are emerging at spatial scales that range from 10(exp 0) to 10(exp 3) km. To keep the computational burden associated with the analysis of such data economically feasible, one approach is to first determine precise GPS satellite positions and clock corrections from a globally distributed network of GPS receivers. Then, data from the local network are analyzed by estimating receiver specific parameters with receiver-specific data; satellite parameters are held fixed at their values determined in the global solution. This "precise point positioning" allows analysis of data from hundreds to thousands of sites every day with 40 Mflop computers, with results comparable in quality to the simultaneous analysis of all data. The reference frames for the global and network solutions can be free of distortion imposed by erroneous fiducial constraints on any sites.

Zumberge, J. F.↗

Precise Point Positioning for the Efficient and Robust Analysis of GPS Data from Large Networks

Networks of dozens to hundreds of permanently operating precision Global Positioning System (GPS) receivers are emerging at spatial scales that range from 10(exp 0) to 10(exp 3) km. To keep the computational burden associated with the analysis of such data economically feasible, one approach is to first determine precise GPS satellite positions and clock corrections from a globally distributed network of GPS receivers. Their, data from the local network are analyzed by estimating receiver- specific parameters with receiver-specific data satellite parameters are held fixed at their values determined in the global solution. This "precise point positioning" allows analysis of data from hundreds to thousands of sites every (lay with 40-Mflop computers, with results comparable in quality to the simultaneous analysis of all data. The reference frames for the global and network solutions can be free of distortion imposed by erroneous fiducial constraints on any sites.

Zumberge, J. F.↗

Real-Time Control and Operation for a Flexible Microgrid with Dynamic Boundary

To better utilize the existing electric power grid distribution network automation of smart switches, a microgrid can expand or shrink its electrical boundary according to available renewable generation. Previous literature only focused on the design of a microgrid with a dynamic boundary, but without considering real-time operation. This paper proposes a microgrid controller that enables operation of microgrid with dynamic boundary and can be integrated into the existing distribution automation system. The architecture of the control system is introduced, and the essential functions such as online topology assessment and synchronization are presented. Simulation results are given to demonstrate the feasibility of the proposed controller.

Ma, Yiwei↗

Distributed control system for parallel-connected DC boost converters

The disclosed invention is a distributed control system for operating a DC bus fed by disparate DC power sources that service a known or unknown load. The voltage sources vary in v-i characteristics and have time-varying, maximum supply capacities. Each source is connected to the bus via a boost converter, which may have different dynamic characteristics and power transfer capacities, but are controlled through PWM. The invention tracks the time-varying power sources and apportions their power contribution while maintaining the DC bus voltage within the specifications. A central digital controller solves the steady-state system for the optimal duty cycle settings that achieve a desired power supply apportionment scheme for a known or predictable DC load. A distributed networked control system is derived from the central system that utilizes communications among controllers to compute a shared estimate of the unknown time-varying load through shared bus current measurements and bus voltage measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Herbaceous Feedstock 2022 State of Technology Report

The U.S. Department of Energy promotes production of advanced liquid transportation fuels from lignocellulosic biomass by funding fundamental and applied research that advances the state of technology (SOT). As part of its involvement in this mission, Idaho National Laboratory completes an annual SOT report for nth-plant and 1st-plant herbaceous biomass feedstock logistics. The purpose of the SOT is to provide the status of feedstock supply system technology development for herbaceous biomass to biofuels relative to technical targets and cost goals from specific design cases, based on data and experimental results. Although conventional feedstock supply systems form the backbone of the emerging biofuels industry, they have limitations that restrict widespread implementation on a national scale. To meet the demands of the future industry, the feedstock supply system must shift from the conventional system to what has been termed “advanced” supply systems. In advanced designs, a distributed network of aggregation and processing centers, termed “depots,” are employed near the points of biomass production (i.e., the field or forest) to reduce feedstock variability and produce feedstocks of a uniform format, moving toward biomass commoditization. The 2022 Herbaceous SOT is part of a vision of achieving an implemented advanced feedstock supply system, which produces a stable, tradable commodity at the decentralized distributed depot. It utilizes feedstock fractionation by incorporating technologies that can separate the biomass into its anatomical fractions (leaves, husks, stems and cobs) to reduce impurities and produce fractions that satisfy downstream quality considerations. By using a series of air classification steps, this strategy can reduce the extrinsic ash in corn stover and produce enriched tissue fractions that can be blended to a conversion specification or converted individually in optimized biochemical conversion campaigns. Additionally, a majority of the leaves (which do not meet the quality specification) are separated out early and can be supplied to alternate markets. The 2022 Herbaceous SOT incorporates an advanced biomass fractionation and processing system to produce pellets enriched tissues from three-pass corn stover. The resulting enriched pellets are delivered to the biorefinery individually where they can be blended to a specification or converted in campaigns where the conditions are optimized for each tissue. Unused fractions can be sent to a a midstream market or to a different conversion process that is better suited to their properties to offset the cost of the delivered feedstock. The main benefits from the proposed system can be summarized as: (1) $6.86/dry ton (2016$) lower cost for the air classification due to elimination of the requirement to discard the high ash lights fraction; (2) $1.56/dry ton lower delivered cost by selling the unsuitable leaf fraction into the feed market as a midstream co-product (assuming a selling price that is 11% higher than their cost of production); (3) 0.98% increase in carbohydrate content (from 60.16% to 61.14%); and (4) 0.97% decrease in ash content (from 6.00% to 5.03%) compared to the 2021 Herbaceous SOT. Overall, the 2022 nth-plant Herbaceous SOT predicts a modeled delivered feedstock cost of $78.64/dry ton (2016$) if it is assumed that the enriched leaf fraction is sold at its production cost; this is a slight increase of $0.43/dry ton increase from the 2021 Herbaceous SOT nth-Supply case cost. The increased cost derived from a $0.38/dry ton increase in transportation and handling cost to procure more biomass (to replace the enriched leaf fraction that was not delivered to the biorefinery. The total preprocessing cost was $0.27/dry ton higher than the 2021 result because of updates to energy consumption, purchasing price and dry matter loss data for the rotary shear ($3.00/dry ton increase) and the pelleting mill ($4.52/dry ton increase). The data utilized were generated in pilot-scale tests in the Biomass Feedstock National User Facility (BFNUF) at INL and at Forest Concepts, including tests for rotary shear and pelleting of the air classified fractions. A greenhouse gas emissions analysis was performed by Argonne National Laboratory using the most up to date version of the Greenhouse Gases, Regulated Emissions, and Energy use in Transportation model (GREET®). The analysis showed an increase of 17.34 kg CO2e/dry ton from the 2021 SOT (67.71 kg CO2e/ton in the 2021 Herbaceous SOT to 85.05 kg CO2e/ton in the 2022 Herbaceous SOT). The net increase is primarily attributed to increased energy consumption in pelleting mill.

09 BIOMASS FUELS↗

Considerations for a Medium-Voltage DC Electrolysis Testbed

Here we present the results of a study focused on the feasibility of using Medium Voltage DC (MVDC) power distribution from wind power generation to electrolyzers for hydrogen production. This approach, using hybrid energy generation in a MVDC microgrid, offers many advantages. These include possible improvements in efficiency, reliability and installation cost compared to a more typical state-of-the-art AC distribution configuration. It also eliminates the need for transformers, which have recently been subject to price volatility and availability concerns. This study highlights the practical feasibility of MVDC distribution networks for integrating various energy sources, offering improved efficiency and reduced system complexity compared to conventional AC-based solutions. Future work will focus on enhancing fault protection strategies, scaling the system to larger renewable installations, and conducting hardware implementation at the National Renewable Energy Laboratory's (NREL) Flatirons Campus (FC). In the sections that follow we show that a DC Collection and Distribution System (DC CDS) reduces the losses associated with the electrical conversion / distribution process relative to a state-of-the-art AC approach, improving overall efficiency by 5%. On the qualitative side, reducing the number of conversion stages is likely to improve reliability, reduce capital investment cost, and enable simpler control algorithms to be used, and reduced risk of instabilities and malfunctions.

08 HYDROGEN↗

Advanced Distribution Protection for High Penetration of Distributed Energy Resources (DER)

With the large amount of distributed energy resources (DER) being added in distribution networks, protection will become a major challenge due to low fault currents and reverse power flows. Present protection schemes that are based on simple over current philosophy will not be adequate. Advanced protection schemes, which can adapt to the changing system configuration is essential. Time-domain based protection that is independent of fault current magnitudes and direction is proposed to enhance the distribution protection.

14 SOLAR ENERGY↗

Coordination of Energy Storage and Distributed Generation for Voltage Control and Peak-valley Filling

The increasing penetration of distributed energy resources (DERs) in distribution network (DN) poses challenges on voltage control. In addition, the growing integration of DERs also reshapes the traditional load profile. To comprehensively address the voltage control and peak-valley filling in DN, this paper proposes a model predictive control (MPC) based optimization framework. The proposed method can achieve coordinated voltage control and peak-valley filling by adjusting the reactive power output from distributed generations (DGs) and the charging/discharging of energy storage systems (ESS). The performance of the proposed method is demonstrated by simulations on a modified IEEE-123 bus system.

Zhang, Zhengfa [University of Tennessee, Knoxville↗

Optically controlled microwave devices and circuits: Emerging applications in space communications systems

Optical control of microwave devices and circuits by an optical fiber has the potential to simplify signal distribution networks in high frequency communications systems. The optical response of two terminal and three terminal (GaAs MESFET, HEMT, PBT) microwave devices are compared and several schemes for controlling such devices by modulated optical signals examined. Monolithic integration of optical and microwave functions on a single semiconductor substrate is considered to provide low power, low loss, and reliable digital and analog optical links for signal distribution.

Bhasin, Kul B.↗

Low-Jitter Clock Receivers for Fast Timing Applications

Precision timing is a key requirement for emerging 4D particle tracking, Positron Emission Tomography (PET), beam and fusion plasma diagnostics, and other systems. Time-to-Digital Converters (TDCs) are commonly used to provide digital estimates of the relative timing between events, but the jitter performance of a TDC can be no better than the performance of the circuits that acquire the pulses and deliver them to the TDC. Several clock receiver and distribution circuits were evaluated, and a differential amplifier with resistive loads driving a pseudo-differential clock distribution network, developed using design guidelines for radiation tolerance and cryogenic compatibility, was fabricated as part of three prototypes: an analog front-end testbed chip for high-precision timing pixel readout, a dedicated TDC evaluation chip, and a Low-Gain Avalanche Detector (LGAD) readout circuit. Based on TDC measurements of the prototypes, we infer that the jitter added by the clock receiver and distribution circuits is less than 2.25 ps-rms. This performance meets the requirements of many future precision timing systems. The clock receiver and on-chip pseudo-differential driver were fabricated in commercial 28-nm CMOS technology and occupy 2288 µm 2 .

47 OTHER INSTRUMENTATION↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices: Preprint

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

A Measurement-Based Adaptive Voltage Regulation Method Considering Topology Changes

This paper proposes an online adaptive data-driven distributed energy resource (DER) dispatch optimization method for voltage control considering topology changes. By using a local sensitivity factor (LSF)-enabled voltage control, traditional DER control can be reformulated into a linear programming (LP) problem, leading to faster computation speeds. Power injection alteration and topology changes are two common operational changes in the distribution network that can affect the LSF and voltage control performance. To address this issue, a robust estimation method is developed to adjust the sensitivity matrix at each time step for the time-varying power injection changes. When topology changes occur, only the allocated predominant LSF submatrices are updated based on measurement data, allowing for a fast adaptation to the system reconfiguration. Results obtained from a real distribution feeder in Southern California demonstrate its robustness as compared to traditional volt-var control and constant LSF matrix dispatch control methods.

DERs↗

Microgrid Cyber Security Reference Architecture (V.1.0)

This document summarizes the on-going cyber security work and resulting cyber security reference architecture for a secure microgrid control system network. The architecture pre sented here provides guidelines and security recommendations for the implementation of a secure microgrid control system at Department of Defense (DOD) installations. The mi crogrid is designed using the Energy Surety MicrogridTM (ESM) methodology developed by Sandia National Laboratories (SNL). Microgrids developed using the ESM methodology demonstrate— • increased reliability for critical mission loads resulting from the interconnection of electrical generation assets using the existing distribution network • reduced reliance on diesel-generated backup power through the use of renewable energy sources during outages • increased efficiency of diesel backup generators through careful, coordinated operation across the microgrid system • reduced operational risk through a strong focus on cyber security The design of a microgrid control system needs to be more robust than that of a traditional industrial control system (ICS) for the following reasons: • The microgrid is used in emergency situations and may be critical to continuity of operations of an installation. • The microgrid must function during active attack by a capable adversary. As such, the traditional design and implementation for an ICS may not be sufficient for implementing a robust and secure microgrid.

Veitch, Cynthia K.↗