Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

The Italian Summer Students Program at Fermilab and other US Laboratories: 40 years of education in particle physics and technology

Since 1983 the Italian groups collaborating with Fermilab (US) have been running a 2-month summer training program for Master students. While in the first year the program involved only 4 physics students, in the following years it was extended to engineering students. Many students have extended their collaboration with Fermilab with their Master Thesis and PhD. The program has involved almost 600 Italian students from more than 20 Italian universities. Each intern is supervised by a Fermilab Mentor responsible for the training program. Training programs spanned from Tevatron, CMS, Muon (g-2), Mu2e and SBN and DUNE design and data analysis, development of particle detectors, design of electronic and accelerator components, development of infrastructures and software for tera-data handling, quantum computing and research on superconductive elements and accelerating cavities. In 2015 the University of Pisa included the program within its own educational programs. Summer Students are enrolled at the University of Pisa for the duration of the internship and at the end of the internship they write summary reports on their achievements. After positive evaluation by a University of Pisa Examining Board, interns are acknowledged 6 ECTS credits for their Diploma Supplement. In the years 2020 and 2021 the program was canceled due to the sanitary emergency but in 2022 it was restarted and allowed a cohort of 21 students in 2022, and a cohort of 27 students in 2023 to be trained for nine weeks at Fermilab. We are now organizing the 2024 program.

Barzi, Emanuela↗

Picosecond Timing Resolution Measurements of Low Gain Avalanche Detectors with a 120 GeV Proton Beam for the TOPSiDE Detector Concept

This paper presents results that take a critical step toward proving 10 ps timing resolution’s feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of 35 μm and 50 μm are evaluated with a 120 GeV proton beam. The performance of the gain and timing response is assessed, including the dependence on the reverse bias voltage and operating temperature. The best timing resolution of UFSDs in a test beam to date is achieved using three combined planes of 35 μm thick LGADs at -30°C with a precision of 14.3 ± 1.5 ps.

Particle tracking detectors↗

Conceptual Design of a Scintillator-Based Fast-Ion Loss Detector for the Wendelstein 7-X Stellarator

Here, a conceptual design of a scintillator-based fast-ion loss detector (FILD) has been developed for the Wendelstein 7-X stellarator (W7-X). Simulations using the Monte Carlo codes ASCOT5 and BEAMS3D have been performed to calculate the expected flux of neutral beam injection (NBI)-generated fast hydrogen ions onto the conceptual detector probe head. These fast-ion loss fluxes have been calculated for several magnetic field configurations as well as probe insertion positions. At the maximum insertion position, both co-and counter-going losses with high incident pitch angles are observed; however, at retracted positions, only co-going fast ions reach the probe head. The FILDSIM code has been used to optimize the geometry of the detector entrance and collimating elements to achieve a wide velocity space coverage as well as a high velocity–space resolution. A synthetic FILD signal is calculated for the expected loss distribution via forward modeling using the instrument response function. The synthetic signal is found to largely retain the velocity space features of the loss distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The “standard” EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms (“neutral bremsstrahlung”, NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep Generative Models for Fast Photon Shower Simulation in ATLAS

The need for large-scale production of highly accurate simulated event samples for the extensive physics programme of the ATLAS experiment at the Large Hadron Collider motivates the development of new simulation techniques. Building on the recent success of deep learning algorithms, variational autoencoders and generative adversarial networks are investigated for modelling the response of the central region of the ATLAS electromagnetic calorimeter to photons of various energies. The properties of synthesised showers are compared with showers from a full detector simulation using GEANT4 . Both variational autoencoders and generative adversarial networks are capable of quickly simulating electromagnetic showers with correct total energies and stochasticity, though the modelling of some shower shape distributions requires more refinement. This feasibility study demonstrates the potential of using such algorithms for ATLAS fast calorimeter simulation in the future and shows a possible way to complement current simulation techniques.

97 MATHEMATICS AND COMPUTING↗

Self-powered perovskite photon-counting detectors

Metal-halide perovskites (MHPs) have been successfully exploited for converting photons to charges or vice versa in applications of solar cells, light-emitting diodes and solar fuels for which all these applications involve strong light. Here we show that self-powered polycrystalline perovskite photodetectors can rival the commercial silicon photomultipliers (SiPMs) for photon counting. The photon-counting capability of perovskite photon-counting detectors (PCDs) is mainly determined by shallow traps, despite that deep traps also limit charge-collection efficiency. Two shallow traps with energy depth of 5.8 ± 0.8 millielectronvolts (meV) and 57.2 ± 0.1 meV are identified in polycrystalline methylammonium lead triiodide, which mainly stay at grain boundaries and the surface, respectively. We show that these shallow traps can be reduced by grain-size enhancement and surface passivation using diphenyl sulfide, respectively. It greatly suppresses dark count rate (DCR) from >20,000 counts per second per square millimetre (cps mm –2 ) to 2 cps mm –2 at room temperature, enabling much better response to weak light than SiPMs. The perovskite PCDs can collect γ-ray spectra with better energy resolution than SiPMs and maintain performance at high temperatures up to 85 °C. The zero-bias operation of perovskite detectors enables no drift of noise and detection property. Finally, this study opens a new application of photon counting for perovskites that uses their unique defect properties.

47 OTHER INSTRUMENTATION↗

Theory of disordered superconductors with applications to nonlinear current response

I present a review of the theory and basic equations for charge transport in superconducting alloys starting from the Keldysh formulation of the quasiclassical transport equations developed by Eilenberger, Larkin and Ovchinnikov, and Eliashberg. This formulation is the natural extension of Landau’s theory of normal Fermi liquids to the superconducting state of strongly correlated metals. For dirty metals the transport equations reduce to equations for charge diffusion, with the current response given by the Drude conductivity at low temperatures. The extension of the diffusion equation for the charge and current response of a strongly disordered normal metal to the superconducting state yields Usadel’s equations for the nonequilibrium quasiclassical Keldysh propagator. The conditions for the applicability of the Usadel equations are discussed, the pair-breaking effect of disorder on the current response, including the nonlinear current response to an electromagnetic field in the dirty limit, τ ≪ ℏ/Δ, are reported. The same nonlinearity is shown to lead to source currents for photon generation and nonlinear Kerr rotation driven by the nonlinear response to excitation of the superconductor by a multi-mode electromagnetic field. The potential relevance of the nonlinear source currents to superconducting radio-frequency cavities as detectors of axion-like dark matter candidates is briefly discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DUAL-PARTICLE DOSEMETER BASED ON ORGANIC SCINTILLATOR

Abstract Traditionally available handheld dosemeters are generally sensitive to only one type of radiation: neutrons or photons. Some dosemeters also rely on very specific attenuation correlations between response and dose, are not scalable in size and multiple dosemeters are required to characterise mixed-particle fields. The research presented here serves as a proof-of-concept for a method to simultaneously measure dose rates from neutrons and photons using a particle discriminating organic scintillation detector without the need for spectral deconvolution. The method was compared with traditional instruments and to simulation. Isotopic photon dose rates measured with this method were within 4% of simulated truth, whereas fission spectrum neutron dose rates were measured within 21%. Measurements of dose rates from both particles agree with simulated truth better than traditional instruments. This new method allows for measurement of dose equivalent from both neutrons and photons with a single instrument and no reliance on spectral deconvolution.

Miller, C. A.↗

Scintillation light calibrations, systematic uncertainties, and triggering efficiency in the MicroBooNE detector

Scintillation light, produced alongside ionisation charge from particle interactions, plays a critical role in liquid argon time projection chamber (LArTPC) detectors. A detailed understanding of its production and detection mechanisms is essential for robust calibration, systematic uncertainty evaluation, and physics analysis. This article describes the MicroBooNE light simulation, light-based triggering schemes, photomultiplier tube gain calibration, light response stability, and light-based systematic uncertainties over the course of five years of data collection. In addition, we present a measurement of scintillation light triggering efficiency, focusing on the lowest-light regime relevant to rare-event searches and low-energy neutrino interactions. Finally, we discuss two notable observations in MicroBooNE's data, both reported here for the first time: an approximately 50% decline in MicroBooNE's light yield over time, concentrated in the first two years of running; and a higher than expected O(200 kHz) rate of single photoelectron noise. The results presented provide an important benchmark of long-term light detection performance in LArTPC neutrino detectors.

Abratenko, P. [Tufts U.]↗

Development of Temperature Compensation Tools for SPNDs Operating in High Temperature Environments

Two rhodium-based self-powered neutron detectors (Rh-SPNDs) were irradiated at the Massachusetts Institute of Technology Reactor as a follow-on experiment to the heated irradiation previously conducted at the Neutron Radiography facility at Idaho National Laboratory. The experiment was conducted over the temperature ranges of 600-850°C to further examine the effects of temperature on the Rh-SPNDs. Four tests of varying temperature and power were performed. The tests identified two types of temperature effects consistent with historical evaluations. One effect is a prompt proportionality to temperature at steady-state reactor power due to the decrease in Rh-SPND insulation resistance. The other effect is a delayed effect generated from displacement currents generated by changing the space charge within the insulator as a function of temperature. The result of this experiment demonstrates a characterizable responses to temperature that is feasible for developing a temperature compensation tool for SPND operating in high temperatures. The characteristics identified in this experiment will be integrated within the delayed-response compensation techniques for FY23 evaluation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Initial Testing of a Small Gamma Detector (GR1+) for Detection of Holdup in HEPA Filters

Measuring and assessing holdup is a key component of proper inventorying of a Material Balance Area (MBA). The Nuclear Material Control and Accountability (NMC&A) group at the Savannah River Site is responsible for ensuring that the methods used to determine holdup in the MBAs are valid for the conditions of that MBA. Holdup can be contained inside processing equipment or inside ventilation systems that that pulls air out of the glovebox through HEPA filters and stainless steel piping.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

From Detector Layout to Signal Analysis: Geometry Optimization and Neutron-Gamma Tagging in Plastic Scintillator Detectors

Neutrinos are elementary particles with many properties still unknown. Their masses so far have only upper and lower limits. Still, due to neutrino oscillations, it is clear that they are not massless, as stated by the Standard Model of Elementary Particles. Neutrinos are also present in the Universe in vast amounts, but they rarely interact with the surrounding matter. Their abundance makes them very interesting for many theories beyond the Standard Model, e.g., dark matter searches and CP symmetry violation in the leptonic sector, which could be (partially) responsible for the observed matter-antimatter asymmetry in today's Universe.\\ The Deep Underground Neutrino Experiment (DUNE) is a next-generation accelerator-based neutrino oscillation experiment that will study neutrinos with unprecedented precision and may answer many open questions. DUNE uses a powerful neutrino beam from Fermilab. It consists of a Near Detector (ND) complex to measure neutrinos before oscillat ion, and a Far Detector (FD) complex $1300\ \mathrm{km}$ away to measure them after oscillation. As part of the ND complex, measurements are also possible with different angles to the neutrino beam. This enables excellent control of systematic uncertainties of e.g., neutrino cross section measurements.\\ One detector in the near detector complex is The Muon Spectrometer (TMS), an extension of a Liquid Argon (LAr) detector that measures the charge and momentum of muons produced in neutrino interactions within the LAr. The design of this detector, which consists of alternating layers of steel and plastic scintillator bars, must be optimized for the expected muon energies.\\ In this thesis, a study of the optimal module orientation plan is presented, which is necessary for the physics performance of the near detector complex and, by extension, DUNE. As part of this study, the event reconstruction was also developed and improved. Simulated muons are then reconstructed, and the performan ce of different module orientation plans is tested.\\ As a second part, a study of neutron and gamma tagging using a Pulse Shape Discriminating (PSD) plastic scintillator is presented. The properties of this material allow particle differentiation based on the temporal distribution of emitted light. A novel approach to using the individual light signals was successfully tested using data from a small, local test setup.

Nehm, Asa [Mainz U.]↗

Analysis of SPND Material Candidates for Real-Time Neutron Spectrum Monitoring Poster

The future of the nuclear industry will be shaped by advanced reactor designs requiring innovative instrumentation for safe operation. A key area of innovation is the ability to accurately and reliably monitor the neutron energy spectrum during operations, which would also enhance the experimental capabilities of existing research reactors. To address this need, our research focuses on the potential use of Self-Powered Neutron Detectors (SPNDs) for real-time neutron spectrum monitoring. We investigated various candidate materials for SPNDs by evaluating their energy-dependent reaction rates. Promising materials were further modeled using MCNP to determine the free electron production per neutron across the neutron energy spectrum, approximating their energy-dependent signal sensitivity. Our findings identified Samarium (Sm) and Gadolinium (Gd) as top candidates for thermal neutrons, Hafnium (Hf) and Thulium (Tm) for epithermal neutrons, and Tantalum (Ta) for fast neutrons. These materials will undergo future experimental validation to confirm the modeled responses and assess their feasibility for real-time neutron spectrum measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Characterizing the initial state and dynamical evolution in XeXe and PbPb collisions using multiparticle cumulants

For the first time, correlations among mixed-order moments of two or three flow harmonics —( v n k , v m l ) and ( v n k , v m l , v p q ), with k, l, and q denoting the respective orders—are measured in xenon–xenon (XeXe) collisions and compared with lead–lead (PbPb) results, providing a novel probe of collective behavior in heavy ion collisions. These measurements compare a nearly spherical, doubly-magic 208 Pb nucleus to a triaxially deformed 129 Xe nucleus, emphasizing the sensitivity to initial-state geometry fluctuations arising from nuclear deformation. The dependence of these results (v n , n = 2 , 3 , 4 ) on the shape and size of the nuclear overlap region is studied. Comparisons between v 2 , v 3 , and v 4 demonstrate the importance of v 3 and v 4 in exploring the nonlinear hydrodynamic response of the quark-gluon plasma (QGP) to the initial spatial anisotropy. The results constrain initial-state model parameters that influence the evolution of the QGP. The CMS detector was used to collect XeXe and PbPb data at nucleon-nucleon center-of-mass energies of S N N = 5.44 and 5.36 TeV, respectively. Correlations are extracted using multiparticle mixed-harmonic cumulants (up to eight-particle cumulants) with charged particles in the pseudorapidity range |η| < 2.4 and transverse momentum range 0.5 < p T < 3 GeV/c.

CMS↗

The Italian Summer Students Program at Fermilab and other US Laboratories: 40 years of education in particle physics and technology

Since 1983 the Italian groups collaborating with Fermilab (US) have been running a 2-month summer training program for Master students. While in the first year the program involved only 4 physics students, in the following years it was extended to engineering students. Many students have extended their collaboration with Fermilab with their Master Thesis and PhD. The program has involved more than 600 Italian students from more than 20 Italian universities. Each intern is supervised by a Fermilab Mentor responsible for the training program. Training programs spanned from Tevatron, CMS, Muon (g-2), Mu2e and SBN (MicroBooNE, Icarus, and SBND) and DUNE design and data analysis, development of particle detectors, design of electronic and accelerator components, development of infrastructures and software for tera-data handling, quantum computing and research on superconductive elements and accelerating cavities. In 2015 the University of Pisa included the program within its own educational programs. Summer Students are enrolled at the University of Pisa for the duration of the internship and at the end of the internship they write summary reports on their achievements. After positive evaluation by a University of Pisa Examining Board, interns are acknowledged 6 ECTS credits for their Diploma Supplement. The program was paused in 2020 and 2021 due to the COVID-19 pandemic, but it resumed in 2022. From 2022 to 2024, a total of 60 students participated in the nine-week training at Fermilab. We are currently organizing the 2025 program. This paper provides an overview of the program, which can serve as a model for other interested laboratories.

Barzi, Emanuela [Ohio State U.]↗

MIP dQ/dx Calibration in DUNE ND-LAr Prototypes with Pixelated Charge Readout

The Deep Underground Neutrino Experiment (DUNE) will be a next-generation long baseline neutrino oscillation experiment that will employ LArTPC technology in a near detector placed at Fermilab and a far detector at the Sanford Underground Research Facility, at a baseline of 1300 km. The DUNE Liquid Argon Near Detector (ND-LAr) design takes into account the high neutrino intensity expected from the beam at the Long-Baseline Neutrino Facility (LBNF): 35 modules, each containing two optically separated time projection chambers, are instrumented with a pixel-based, true 3D charge readout alongside scintillation light traps to disentangle the O(100) interactions expected per 10us beam spill. A robust prototyping program supports ND-LAr’s design: the 2x2 Demonstrator consists of four scaled-down ND-LAr modules exposed to the NuMI beam at Fermilab, and the Full Scale Demonstrator (FSD) is a single ND-LAr module tested with cosmic rays at the University of Bern. We present here an analysis of minimum ionizing particle (MIP) tracks selected from 2x2 beam data and FSD cosmic ray data used to benchmark the pixel-based charge readout simulation and calibration in both detectors, with the ultimate goal of validating the design of DUNE ND-LAr as well as informing future calibration methods. This poster will showcase the dependence of the charge response on track inclination as well as a per-pixel dQ/dX extraction.

Mandujano, Roberto [UC, Irvine]↗