Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data conditioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Static and free-vibrational response of semi-circular graphite-epoxy frames with thin-walled open sections

Experiments were conducted to measure the three-dimensional static and free vibrational response of two graphite-epoxy, thin-walled, open section frames. The frames are semi-circular with a radius of three feet, and one specimen has an I cross section and the other has a channel cross section. The flexibility influence coefficients were measured in static tests for loads applied at midspan with the ends of the specimens clamped. Natural frequencies and modes were determined from vibrational tests for free and clamped end conditions. The experimental data is used to evaluate a new finite element which was developed specifically for the analysis of curved, thin-walled structures. The formulation of the element is based on a Vlasov-type, thin-walled, curved beam theory. The predictions from the finite element program generally correlated well with the experimental data for the symmetric I-specimen. Discrepancies in some of the data were found to be due to flexibility in the clamped end conditions. With respect to the data for the channel specimen, the correlation was less satisfactory. The finite element analysis predicted the out-of-plane response of the channel specimen reasonably well, but large discrepancies occurred between the predicted in-plane response and the experimental data. The analysis predicted a much more compliant in-plane response than was observed in the experiments.

Collins, J. Scott↗

Biases in Long-term NO2 Averages Inferred from Satellite Observations Due to Cloud Selection Criteria

Retrievals of atmospheric trace gas column densities from space are compromised by the presence of clouds, requiring most studies to exclude observations with significant cloud fractions in the instrument's field of view. Using NO2 observations at three ground stations representing urban, suburban, and rural environments, and tropospheric vertical column densities measured by the Ozone Monitoring Instrument (OMI) over each site, we show that the observations from space represent monthly averaged ground-level pollutant conditions well (R=0.86) under relatively cloud-free conditions. However, by analyzing the ground-level data and applying the OMI cloud fraction as a filter, we show there is a significant bias in long-term averaged NO2 as a result of removing the data during cloudy conditions. For the ground-based sites considered in this study, excluding observations on days when OMI-derived cloud fractions were greater than 0.2 causes 12:00-14:00 mean summer mixing ratios to be underestimated by 12%+/-6%, 20%+/-7%, and 40%+/-10% on average (+/-1 standard deviation) at the urban, suburban, and rural sites respectively. This bias was investigated in particular at the rural site, a region where pollutant transport is the main source of NO2, and where longterm observations of NOy were also available. Evidence of changing photochemical conditions and a correlation between clear skies and the transport of cleaner air masses play key roles in explaining the bias. The magnitude of a bias is expected to vary from site to site depending on meteorology and proximity to NOx sources, and decreases when longer averaging times of ground station data (e.g. 24-h) are used for the comparison.

SEASONAL-VARIATIONS↗

Data compression for the microgravity experiments

Researchers present the environment and conditions under which data compression is to be performed for the microgravity experiment. Also presented are some coding techniques that would be useful for coding in this environment. It should be emphasized that researchers are currently at the beginning of this program and the toolkit mentioned is far from complete.

Sayood, Khalid↗

Usefulness of LANDSAT data for monitoring plant development and range conditions in California's annual grassland

A network of sampling sites throughout the annual grassland region was established to correlate plant growth in stages and forage production to climatic and other environmental factors. Plant growth and range conditions were further related to geographic location and seasonal variations. A sequence of LANDSAT data was obtained covering critical periods in the growth cycle. Data were analyzed by both photointerpretation and computer aided techniques. Image characteristics and spectral reflectance data were then related to forage production, range condition, range site, and changing growth conditions.

Carneggie, D. M.↗

Earth Radiation Budget Experiment (ERBE) validation

During the past 4 years, data from the Earth Radiation Budget Experiment (ERBE) have been undergoing detailed examination. There is no direct source of groundtruth for the radiation budget. Thus, this validation effort has had to rely heavily upon intercomparisons between different types of measurements. The ERBE SCIENCE Team chose 10 measures of agreement as validation criteria. Late in August 1988, the Team agreed that the data met these conditions. As a result, the final, monthly averaged data products are being archived. These products, their validation, and some results for January 1986 are described. Information is provided on obtaining the data from the archive.

Barkstrom, Bruce R.↗

Boundary layer study on nozzle wall at hypersonic velocities

The boundary layer on the wall of the Hypervelocity Tunnel 9 was investigated with pitot pressure and total temperature measurements. Experimental results are presented for standard and supercooled Mach 14 runs. The boundary layer data at supercooled conditions are compared to numerical predictions made with a Navier-Stokes algorithm including vibrational nonequilibrium and intermolecular force effects. For standard tunnel conditions, the numerical solutions agree well with experimental data. For the supercooled cases, the numerical code predicts the total temperature but overpredicts the pitot pressure.

Jones, Kenneth M.↗

High speed computerized data acquisition of photovoltaic V-I characteristics

The voltage current (V-I) characteristics of the photovoltaic array were studied under actual environmental conditions. A method of data acquisition was devised that uses a capacitor charge technique to obtain the V-I characteristic and a computerized data system to display, record and process the data. The capacitor charge technique uses an array shorting transistor and a capacitor bank to sweep the array operating voltage and current from short circuit to open circuit in a specified time (approximately 125 ms). The computerized data system is synchronized with this transition and repetitively samples the array voltage and current during the transition and records the ambient conditions. This data is then normalized by the computer to standard conditions (100 mW/sq cm, 28 C) and is available in tabular and graphic form for both the voltage current and voltage power characteristics. The capacitor charge technique is described.

Delombard, R.↗

Similarity tests of turbine vanes, effects of ceramic thermal barrier coatings

The role of material thermal conductivity was analyzed for its effect on the thermal performance of air-cooled gas turbine components coated with a ceramic thermal barrier material when tested at reduced temperatures and pressures. It is shown that the thermal performance can be evaluated reliably at reduced gas and coolant conditions; however, thermal conductivity corrections are required for the data at reduced conditions. Corrections for a ceramic thermal barrier coated vane are significantly different than for an uncoated vane. Comparison of uncorrected test data, therefore, would show erroneously that the thermal barrier coating was ineffective. When thermal conductivity corrections are applied to the test data these data are then shown to be representative of engine data and also show that the thermal barrier coating increases the vane cooling effectiveness by 12.5 percent.

Gladden, H. J.↗

DECOVALEX-2023: Task D Final Report

Task D of DECOVALEX-2023 is focused on the simulation of the coupled thermal hydraulic-mechanical (THM) behaviour in the full-scale engineered barrier system (EBS). The Horonobe EBS experiment is the demonstration of the full-scale EBS in the underground research laboratory (URL) (performed by JAEA in the Horonobe URL in Japan). Task D consisted of the three steps, a preliminary step (Step 0), simulation of the laboratory tests (Step 1) and simulation of the in-situ full-scale EBS experiment (Step 2). Since the Horonobe EBS experiment demonstrates the vertical emplacement option of the EBS, the experiment gallery is also backfilled with the backfill material. Therefore, interaction between the EBS and the backfill material can also be demonstrated, such as deformation (change of density) of the buffer material. The underground water in the Horonobe URL is saline. This fact adds chemical processes to THM behaviour. For example, mechanical properties (such as swelling pressure of the buffer material and backfill material) and hydraulic properties (such as permeability of the buffer material and backfill material) change depending on the water chemistry. Task D was therefore a challenging Task focused on not only the relatively simple THM behaviour but also complex THM behaviour including chemical processes. Six research teams (BGR, CAS, JAEA, KAERI, SNL and Taipower) participated the Task D. BGR, CAS, JAEA, KAERI and Taipower research teams selected a THM approach, while the SNL research team selected a TH approach. Step 1 involved the simulation of laboratory test results and was important to check the numerical codes developed by the research teams. Step 1 was divided into four sub steps. The simulation results through the Step 1 identified the parameters for simulation of the Step 2. Basic parameters of the materials (buffer material, backfill material, rock mass, concrete, sand) were provided by JAEA. Special parameters which research team needed were identified by back analysis of Step 1. Most notably the mechanical behaviour of swelling and displacement depended on the applied model (elastic model or elastoplastic model). Parameters such as Young’s modulus were found to need smaller values than characterised in the fundamental laboratory test results (Step 1-1, 1-2) for the elastic model. Although laboratory experiments are usually simple, test results contained some error. For example, if the saturation level is 100 % or higher, it should be considered an error. This situation was presented in the Step 1-3. A possible reason is that the buffer material is a mixture of bentonite and silica sand. When a specimen is cut to measure volume or weight, sand grains will affect the measurement data. In Step 2, boundary conditions such as temperature on the surface of the simulated overpack, heater power of the electrical heaters installed in the simulated overpack, injection pressure and inflow rate of the test water, were applied. The outer boundary conditions can be selected using measured data (injection pressure and inflow rate of the test water that is controlled by the injection systems installed in the sand layer around the buffer material and in the boundary between backfill material and concrete support). Since such measured data has some noise, research teams developed their own simplified boundary conditions. Inner boundary conditions can be selected using measured data as heater power and temperature on the surface of the simulated overpack. These data also contain some noise, so research teams developed their own simplified developed boundary conditions. Task D validated various approaches thorough the simulation of the in-situ full scale EBS system including backfill of the gallery: variations in the coupling processes (THM or THC), analysis codes, and boundary conditions. Temperature distribution in the buffer material was simulated well by all research teams. This means thermal behaviour is not sensitive to the simulation approaches. Although the water content distribution on the outside of the buffer material was well simulated by all research teams, the simulation results differ from the measured values inside the buffer material (at the centre and inside, near the simulated overpack). The buffer material is made from tap water, but in the in-situ experiment, saline groundwater infiltrates the buffer material. Therefore, the selection of the hydraulic parameters of the buffer material greatly affects the simulation results of the re saturation behaviour of the buffer material. In the Horonobe EBS experiment, measured values suitable for validating the simulation results were not obtained near the simulated overpack. When simulating the pressure and deformation of the buffer material, the measurement data is easily affected by the installation conditions of the measurement sensors, so verifying the measurement data itself remains an issue. Mechanical simulation results differ depending on whether they are considered as elastic or elastoplastic phenomena. The accuracy of measured in-situ data can be assessed by detailed analysis comparing sampling specimen analysis and measured data. The Horonobe EBS experiment is scheduled to be dismantled in the future (FY2026 and 2027). This detailed dismantling investigation will finally confirm the measured data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of potential flow theory to evaluate subsonic inlet data from a simulator-powered nacelle at cruise conditions

Incompressible potential flow theory corrected for compressibility effects, using the Lieblein-Stockman compressibility correction, was used to predict surface and flow field static pressures for a subsonic inlet at cruise conditions. The calculated internal and external surface static pressures were in good agreement with data at most conditions. The analysis was used to determine the capture stream-tube location and static-pressure distribution. Additive drag coefficients obtained from these results were consistently higher than those obtained using one-dimensional compressible flow theory. Increasing the distance between the inlet and boattail increased the cowl drag force. The effect of the boundary layer on internal and external surface static-pressure distributions was small at the design cruise condition. The analytical results may be used as an aid to data reduction and for predicting inlet mass flow, stagnation point location, and inlet additive drag.

Bober, L. J.↗

Similarity tests of turbine vanes - Effects of ceramic thermal barrier coatings

The role of material thermal conductivity was analyzed for its effect on the thermal performance of air-cooled gas turbine components coated with a ceramic thermal barrier material when tested at reduced temperatures and pressures. This study shows that the thermal performance can be evaluated reliably at reduced gas and coolant conditions. However, thermal conductivity corrections are required for the data at reduced conditions. These corrections for a ceramic thermal barrier coated vane are significantly different than the corrections for an uncoated vane. Comparison of uncorrected test data, therefore, would show erroneously that the thermal barrier coating was ineffective. When thermal conductivity corrections are applied to the test data these data are then shown to be representative of engine data and also show that the thermal barrier coating increases the vane cooling effectiveness by 12.5 precent.

Gladden, H. J.↗

DEM, DSM, and Cleaned LiDAR Point Cloud Data from the NGEE Arctic UAS Campaigns at the Teller 27 Field Site from 2017 and 2018, Seward Peninsula, Alaska

A Digital Elevation Model (DEM) and Digital Surface Model (DSM) were derived from airborne Light Detection and Ranging (LiDAR) data collected from Los Alamos National Laboratory's (LANL) heavy-lift unoccupied aerial system (UAS) quadcopter and hexacopter platforms operated by Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic) scientists from the EES-14 group at LANL. These data were collected in August 2017 and July 2018 at the NGEE Arctic field site near mile marker 27 of the Bob Blodgett Nome-Teller Memorial Highway between Nome, Alaska and Teller, Alaska. A Vulcan Raven X8 Airframe (Mitcheldean, Gloucestershire, UK), DJI Matrice 600 Pro Airframe (Shenzhen, China), and Routescene UAV LiDARSystem (Edinburgh, Scotland, UK) were used to collect LiDAR data. Following pre-processing in Routescene LidarViewer Pro software, the LiDAR point clouds were cleaned and processed using CloudCompare software to separate ground and off-ground points. A high resolution DEM and DSM were then created using ArcGIS Pro software. This data package contains fully cleaned point clouds of ground and off-ground points (.las), a 25 cm DEM (.tif), and a 25 cm DSM (.tif) for the Teller 27 field site. Ancillary aircraft data, flight mission parameters, weather conditions, and raw lidar data and imagery can be found in the L0 datasets for these campaigns: NGA299 (2017) and NGA297 (2018). Minimally processed point clouds and auxiliary files can be found in the L1 dataset: NGA304 (2017 and 2018).The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Pressure and heat transfer investigation of a modified NASP baseline configuration at M = 6

A cooperative NASA Langley-Boeing investigation was conducted in the Langley eight-Foot High Temperature Tunnel to obtain hypersonic pressure and heat transfer data. In this investigation a large scale (1/20), modified version of the National Aero-Space Plane configuration known as the 'Government Baseline' was tested at a nominal Mach number of 6; at two Reynolds numbers (0.6 and 1.6 million per foot); and at angles of attack from about 0 to 15 deg. There were several purposes for the investigation: to provide a windward and leeward pressure and heat transfer data base for a realistic configuration for verification of computational methods, to provide these data for a large-scale model, and to provide these data for true temperature conditions because of concern about data from low temperature tunnels.

Reubush, David E.↗

Production of NO2 from Photolysis of Peroxyacetyl Nitrate

Peroxyacetyl nitrate (PAN) vapor was photolyzed at 248 nm, and the NO2 photoproduct was detected by laser-induced fluorescence. The quantum yield for the production of NO2 from PAN photolysis was determined by comparison to HNO3 photolysis data taken under identical experimental conditions. The average of data collected over a range of total pressures, precursor concentrations, and buffer gases was 0.83 +/- 0.09 for the NO2 quantum yield, where the statistical uncertainty is 2 standard deviations.

Mazely, Troy L.↗

Spray Cooling Processes for Space Applications

The present paper reports ongoing work to develop numerical and modeling tools used to design efficient and effective spray cooling processes and to determine characteristic non-dimensional parametric dependence for practical fluids and conditions. In particular, we present data that will delineate conditions towards control of the impingement dynamics of droplets upon a heated substrate germane to practical situations.

Kizito, John P.↗

Power management for wireless nodes

A system includes a rectifier having an input configured to receive a variable AC input voltage and convert the AC input voltage to a rectified output voltage. A power converter has an input coupled to receive the rectified output voltage and to provide a DC supply voltage at an output thereof. A low drop-out regulator has an input coupled to receive the supply voltage and is configured provide a regulated voltage. A sensor is coupled to receive the regulated voltage as a power source and is configured to sense a condition and provide sensor data indicative of the sensed condition.

Feng, Philip X. L.↗

Laser velocimeter measurements of the flow field generated by a forward-swept propfan during flutter

Results are presented from an investigation to measure the flow field generated by a forward-swept propfan operating in flutter at a low forward velocity. For comparison to the flutter condition, flow field data are also presented for a slightly reduced rotational speed just below flutter. The forward-swept propfan was tested as the front rotor of a counterrotating pusher propeller. A laser Doppler velocimeter (LDV) was used to measure the velocity field in planes normal to the model centerline downstream of the rotor and in planes of constant radius within the blade passages at each operating condition. A comparison of the data taken at the two different operating conditions indicated that the mean, time-averaged flow about the blades did not change drastically as the propfan rotational speed was increased from the stable operating point to the flutter condition. No regions of flow separation could be identified in the data plots of the mean intrablade flow field. The data also indicate that the relative flow about the blades remained subsonic during flutter operation. The blades were found to have a higher than expected tip loading at both operating conditions. This is thought to have been caused by the outer blade sections twisting under load to higher than expected effective blade angles. This high tip loading resulted in strong vortices and a very nonuniform flow downstream of the tips of the forward-swept blades. This high tip loading may also have caused the blade flutter.

Podboy, Gary G.↗