Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Illustrating the future prediction of performance based on computer code, physical experiments, and critical performance parameter samples

In this paper, we present a generic example to illustrate various points about making future predictions of population performance using a biased performance computer code, physical performance data, and critical performance parameter data sampled from the population at various times. We show how the actual performance data help to correct the biased computer code and the impact of uncertainty especially when the prediction is made far from where the available data are taken. We also demonstrate how a Bayesian approach allows both inferences about the unknown parameters and predictions to be made in a consistent framework.

99 GENERAL AND MISCELLANEOUS↗

Graphene SHDMC Data

The data used to produce all of the figures and tables in the manuscript titled "Highly Accurate Many-Body Theory Reaches 2D Materials" can be found here. This data set includes: -SHDMC results for graphene -selected CI with and without re-normalized second-order perturbation (rPT2) theory corrections for graphene -data demonstrating that SHDMC displays an exponential rate of convergence -data used for sCI + rPT2 complete basis set extrapolation -data used to extrapolate SHDMC energies to the infinite basis limit -data used to demonstrate compactness of SHDMC wavefunction

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Error-correction coding for hot-swapping semiconductor devices

A memory read operation is directed at a group of semiconductor devices from which a first semiconductor device has been removed. An error in data for the memory read operation is detected based on error-correction coding (ECC). The error is caused at least in part by the first semiconductor device having been removed. ECC is used to determine corrected data for the memory read operation.

42 ENGINEERING↗

Data assimilation empowered neural network parametrizations for subgrid processes in geophysical flows

In the past couple of years, there has been a proliferation in the use of machine learning approaches to represent subgrid-scale processes in geophysical flows with an aim to improve the forecasting capability and to accelerate numerical simulations of these flows. Despite its success for different types of flow, the online deployment of a data-driven closure model can cause instabilities and biases in modeling the overall effect of subgrid-scale processes, which in turn leads to inaccurate prediction. To tackle this issue, we exploit the data assimilation technique to correct the physics-based model coupled with the neural network as a surrogate for unresolved flow dynamics in multiscale systems. In particular, we use a set of neural network architectures to learn the correlation between resolved flow variables and the parametrizations of unresolved flow dynamics and formulate a data assimilation approach to correct the hybrid model during their online deployment. We illustrate our framework in a set of applications of the multiscale Lorenz 96 system for which the parametrization model for unresolved scales is exactly known, and the two-dimensional Kraichnan turbulence system for which the parametrization model for unresolved scales is not known a priori. Our analysis, therefore, comprises a predictive dynamical core empowered by (i) a data-driven closure model for subgrid-scale processes, (ii) a data assimilation approach for forecast error correction, and (iii) both data-driven closure and data assimilation procedures. We show significant improvement in the long-term prediction of the underlying chaotic dynamics with our framework compared to using only neural network parametrizations for future prediction. Moreover, we demonstrate that these data-driven parametrization models can handle the non-Gaussian statistics of subgrid-scale processes, and effectively improve the accuracy of outer data assimilation workflow loops in a modular nonintrusive way.

42 ENGINEERING↗

A Workflow for Visual Diagnostics of Binary Classifiers using Instance-Level Explanations

In this paper, we propose a visual analytics workflow to help data scientists explore, diagnose, and understand the decisions made by a binary classifier. The approach leverages “instance-level explanations”, measures of local feature relevance that explain single instances and uses them to build a set of visual representations that guide the users in their investigation. The workflow is based on three main visual representations and steps: one based on aggregate statistics to see how data distributes across correct or incorrect decisions; one based on explanations to understand which features are used to make these decisions; and one based on raw data, to derive insights on potential root causes for the observed patterns. The work is validated through a long-term collaboration with a group of healthcare professionals who used our method to make sense of machine learning models they developed. The case studies from this collaboration demonstrate that the proposed method helps experts derive useful knowledge about the model and the phenomena it describes and also generates useful hypotheses on how a model can be improved.

Krause, Josua↗

Monte Carlo sampling and correlation coefficients of critical experiments

We study the influence of calculation parameters on Monte-Carlo generated correlation coefficients of k{sub eff} values for a data set of critical experiments. The correlation coefficients can be used e.g. to reduce conservatism in bias estimations, but generally must be treated correctly if a data set includes correlations. We find that the actual value of the correlation coefficient for a given data set depends on the number of samples and the ratio of the sampling uncertainty to the Monte-Carlo uncertainty of the individual k{sub eff} calculation. We also discuss that the number of input parameters of the model to calculate the k{sub eff} values do not necessarily impact the convergence of the correlation coefficient with increasing sample number. However, we explain how varying the aforementioned parameters lead to different converged results for the correlation coefficients. The conclusion is that a correlation coefficient should not be discussed isolated but with the underlying uncertainties of both, the k{sub eff} estimation and the Monte Carlo sampling approach. The underlying modelling approach of the experimental data has to be described in detail. This should include a sensitivity analysis of the impact of input parameters on the k{sub eff} uncertainty with respect to the modelling approach.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reanalysis of the Trotter Tibia Quandary and its Continued Effect on Stature Estimation of Past‐Conflict Service Members

Abstract Forensic casework from past‐conflicts relies on the corrected historical Trotter data for stature estimation in Fordisc. For roughly 10 years’, stature estimation using this data has produced point estimates for the tibia that are on average 1.25 inches less than the other long bones. This issue was identified after applying the equations derived from Fordisc to the USS Oklahoma commingled assemblage. Reevaluation of Fordisc revealed that a correction factor of 20 mm, instead of 10 mm, was mistakenly applied to the Trotter tibia data. Historical forensic anthropology reports written at the Defense POW / MIA Accounting Agency were utilized to identify that the overcorrection is isolated to Fordisc 3 with an error rate of 5% of known antemortem statures falling outside of the prediction intervals that relied on the tibia. Further evaluation of the Oklahoma sample indicates the 10 mm correction is still producing point estimates less than the other long bones.

Lynch, Jeffrey James↗

Corrective Action Decision Document/ Closure Report for Corrective Action Unit 556: Dry Wells and Surface Release Points, Nevada Test Site, Nevada with Errata Sheet and ROTC 1

This Corrective Action Decision Document (CADD)/Closure Report (CR) has been prepared for Corrective Action Unit 556, Dry Wells and Surface Release Points, located at the Nevada Test Site, Nevada, in accordance with the Federal Facility Agreement and Consent Order (FFACO, 1996; as amended February 2008). Corrective Action Unit (CAU) 556 is comprised of four corrective action sites (CASs): • 06-20-04, National Cementers Dry Well • 06-99-09, Birdwell Test Hole • 25-60-03, E-MAD Stormwater Discharge and Piping • 25-64-01, Vehicle Washdown and Drainage Pit The purpose of this CADD/CR is to provide justification and documentation supporting the recommendation for closure of CAU 556 with no further corrective action. To achieve this, corrective action investigation (CAI) activities began on February 7 and were completed on June 19, 2008, as set forth in the Corrective Action Investigation Plan for Corrective Action Unit 556: Dry Wells and Surface Release Points, Nevada Test Site, Nevada (NNSA/NSO, 2007). The purpose of the CAI was to fulfill the following data needs as defined during the data quality objective (DQO) process: • Determine whether contaminants of concern (COCs) are present. • If COCs are present, determine their nature and extent. • Provide sufficient information and data to complete appropriate corrective actions. The CAU 556 data were evaluated based on the data quality assessment process, which demonstrated the quality and acceptability of the data for use in fulfilling the DQO data needs. Analytes detected during the CAI were evaluated against appropriate final action levels (FALs) to identify the COCs for each CAS. The results of the CAI identified COCs at one of the four CASs in CAU 556 that required the completion of a corrective action. Assessment of the data generated from investigation activities conducted at CAU 556 revealed the following: • Corrective Action Sites 06-20-04, 06-99-09, and 25-64-01 do not contain contamination at concentrations exceeding the FALs. • Polychlorinated biphenyl (PCB) contamination above the FAL was identified in the surface and/or shallow subsurface soils at the outfall and around Catch Basin 2, and in soils contained within the catch basins and the manhole at CAS 25-60-03. A corrective action of close in place with a soil removal action and use restriction (UR) was completed at CAS 25-60-03. The PCB-contaminated soils were removed from the outfall area and around Catch Basin 2, and disposed of at a Nevada Test Site landfill as part of a removal action. The catch basins and the manhole were sealed shut by filling them with grout. The end of the outfall pipe was plugged using grout, covered with soil, and the area was regraded. A UR was applied to the entire stormwater system at CAS 25-60-03, which includes the three catch basins, manhole, and associated piping. No further action is the corrective action for CASs 06-20-04, 06-99-09, and 25-64-01. The liquids in the test holes at CAS 06-99-09 were removed for disposal and the features were filled with grout as a best management practice. The drainage pipe between the vehicle washdown pad and the drainage pit at CAS 25-64-01 was sealed at each end as a best management practice. The corrective actions were evaluated on technical merit focusing on performance, reliability, feasibility, safety, and cost. They were judged to meet all requirements for the technical components evaluated. The corrective actions meet all applicable federal and state regulations for closure of the site and will reduce potential exposure pathways to the contaminated media to an acceptable level at CAU 556. Therefore, the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office provides the following recommendations: • Maintain a UR for the entire stormwater drainage system (i.e., three catch basins, one manhole, and associated piping) at CAS 25-60-03. • No further corrective action for CAU 556. • A Notice of Completion to the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office is requested from the Nevada Division of Environmental Protection for closure of CAU 556. • Corrective Action Unit 556 should be moved from Appendix III to Appendix IV of the Federal Facility Agreement and Consent Order.

54 ENVIRONMENTAL SCIENCES↗

Dose Recalculation and the Dose-Guided Radiation Therapy (DGRT) Process Using Megavoltage Cone-Beam CT

Purpose: At University of California San Francisco, daily or weekly three-dimensional images of patients in treatment position are acquired for image-guided radiation therapy. These images can be used for calculating the actual dose delivered to the patient during treatment. In this article, we present the process of performing dose recalculation on megavoltage cone-beam computed tomography images and discuss possible strategies for dose-guided radiation therapy (DGRT). Materials and Methods: A dedicated workstation has been developed to incorporate the necessary elements of DGRT. Patient image correction (cupping, missing data artifacts), calibration, completion, recontouring, and dose recalculation are all implemented in the workstation. Tools for dose comparison are also included. Examples of image correction and dose analysis using 6 head-and-neck and 2 prostate patient datasets are presented to show possible tracking of interfraction dosimetric endpoint variation over the course of treatment. Results: Analysis of the head-and-neck datasets shows that interfraction treatment doses vary compared with the planning dose for the organs at risk, with the mean parotid dose and spinal cord D{sub 1} increasing by as much as 52% and 10%, respectively. Variation of the coverage to the target volumes was small, with an average D{sub 5} dose difference of 1%. The prostate patient datasets revealed accurate dose coverage to the targeted prostate and varying interfraction dose distributions to the organs at risk. Conclusions: An effective workflow for the clinical implementation of DGRT has been established. With these techniques in place, future clinical developments in adaptive radiation therapy through daily or weekly dosimetric measurements of treatment day images are possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Jet energy calibration at the LHC

In this study, jets are one of the most prominent physics signatures of high energy proton–proton (p–p) collisions at the Large Hadron Collider (LHC). They are key physics objects for precision measurements and searches for new phenomena. This review provides an overview of the reconstruction and calibration of jets at the LHC during its first Run. ATLAS and CMS developed different approaches for the reconstruction of jets, but use similar methods for the energy calibration. ATLAS reconstructs jets utilizing input signals from their calorimeters and use charged particle tracks to refine their energy measurement and suppress the effects of multiple p–p interactions ( pileup ). CMS, instead, combines calorimeter and tracking information to build jets from particle flow objects. Jets are calibrated using Monte Carlo (MC) simulations and a residual in situ calibration derived from collision data is applied to correct for the differences in jet response between data and Monte Carlo.

43 PARTICLE ACCELERATORS↗

On the predictability of turbulent fluxes from land: PLUMBER2 MIP experimental description and preliminary results

Accurate representation of the turbulent exchange of carbon, water, and heat between the land surface and the atmosphere is critical for modelling global energy, water, and carbon cycles in both future climate projections and weather forecasts. Evaluation of models' ability to do this is performed in a wide range of simulation environments, often without explicit consideration of the degree of observational constraint or uncertainty and typically without quantification of benchmark performance expectations. We describe a Model Intercomparison Project (MIP) that attempts to resolve these shortcomings, comparing the surface turbulent heat flux predictions of around 20 different land models provided with in situ meteorological forcing evaluated with measured surface fluxes using quality-controlled data from 170 eddy-covariance-based flux tower sites. Predictions from seven out-of-sample empirical models are used to quantify the information available to land models in their forcing data and so the potential for land model performance improvement. Sites with unusual behaviour, complicated processes, poor data quality, or uncommon flux magnitude are more difficult to predict for both mechanistic and empirical models, providing a means of fairer assessment of land model performance. When examining observational uncertainty, model performance does not appear to improve in low-turbulence periods or with energy-balance-corrected flux tower data, and indeed some results raise questions about whether the energy balance correction process itself is appropriate. In all cases the results are broadly consistent, with simple out-of-sample empirical models, including linear regression, comfortably outperforming mechanistic land models. In all but two cases, latent heat flux and net ecosystem exchange of CO 2 are better predicted by land models than sensible heat flux, despite it seeming to have fewer physical controlling processes. Land models that are implemented in Earth system models also appear to perform notably better than stand-alone ecosystem (including demographic) models, at least in terms of the fluxes examined here. The approach we outline enables isolation of the locations and conditions under which model developers can know that a land model can improve, allowing information pathways and discrete parameterisations in models to be identified and targeted for future model development.

54 ENVIRONMENTAL SCIENCES↗

Testing Different Methods for Estimating Uncertainties on Rietveld Refined Parameters Using SrRietveld

The advent of fast computing allows more computationally expensive, though possibly more accurate, approaches for estimating uncertainties on Rietveld refined parameters. Here we compare three such methods, using two different refinement programs, FullProf and GSAS. This is facilitated by the use of a new Rietveld refinement package, SrRietveld, that provides Python wrappers for FullProf and GSAS. The refined values on the parameters from two different refinement engines match each other very well. The uncertainty estimates determined using the different methods are also consistent, though FullProf and GSAS estimate the parameter uncertainties slightly differently from each other, which is discussed. More importantly, we find that the refined results are very sensitive to the statistical weights used in the least squares equation. Different weights, for example from uncertain or incorrectly propagated random errors on the data, lead to significantly different refined values. This means that uncertainty estimates on refined parameters should be increased when the random errors on the data are not well known, as for example in many cases where area detectors are used, and care should be taken to propagate errors correctly in any data preprocessing such as normalization by a smoothed spectrum. The computationally expensive bootstrap error estimation methods are facilitated by the use of SrRietveld, but are not required in most cases though may be useful in some cases, for example if the random errors on the data are not well known.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MEASURING CLAS12 D(E, E′Π±) CROSS SECTIONS FOR E4NU

Neutrino experiments need neutrino event generators such as GENIE to simulate neutrinonucleus (¿A) interactions in order to measure neutrino oscillations. We need eA data to validate GENIE. GENIE d(e, e') cross sections do not match data in the pion production region. Further analysis of this region can help constrain GENIE models. The goal of this project was to compare 4.244 GeV CLAS12 d(e, e'p±) cross sections to GENIE predictions. We analyzed data from the Fall 2019 run period of Run Group B (RG-B). We applied particle identification, fiducial, and vertex cuts on electron and charged pion candidates. We compared the measured data with events generated with GENIE and another generator called onepigen. We used onepigen to simulate single charged pion production and to calculate radiative corrections for the data. We submitted GENIE and onepigen events to the GEant4 Monte-Carlo (GEMC) simulation of CLAS12 and applied the same cuts we used on the data. We plotted cross sections as functions of W and binned the events in Q2, ¿pq, and Pp. We used 2D (Q2), 3D (Q2 with ¿pq or Pp), and 4D (Q2, ¿pq, and Pp) binning schemes. We found GENIE describes d(e, e'p±) cross sections better than expected. GENIE describes the data remarkably well in the 2D bins and some 3D and 4D bins. There are many discrepancies between GENIE and data in the other 3D and 4D bins. The results show that, relative to data, GENIE cross sections increase as Q2 increases, decrease as Pp increases, and fit best at low ¿pq. These results will help guide improvements to GENIE in order to reduce the systematic uncertainties in neutrino-oscillation experiments.

Fogler, Caleb [Old Dominion Univ., Norfolk, VA (Un↗

Local respiratory motion correction for PET/CT imaging: Application to lung cancer

Purpose: Despite multiple methodologies already proposed to correct respiratory motion in the whole PET imaging field of view (FOV), such approaches have not found wide acceptance in clinical routine. An alternative can be the local respiratory motion correction (LRMC) of data corresponding to a given volume of interest (VOI: organ or tumor). Advantages of LRMC include the use of a simple motion model, faster execution times, and organ specific motion correction. The purpose of this study was to evaluate the performance of LMRC using various motion models for oncology (lung lesion) applications. Methods: Both simulated (NURBS based 4D cardiac-torso phantom) and clinical studies (six patients) were used in the evaluation of the proposed LRMC approach. PET data were acquired in list-mode and synchronized with respiration. The implemented approach consists first in defining a VOI on the reconstructed motion average image. Gated PET images of the VOI are subsequently reconstructed using only lines of response passing through the selected VOI and are used in combination with a center of gravity or an affine/elastic registration algorithm to derive the transformation maps corresponding to the respiration effects. Those are finally integrated in the reconstruction process to produce a motion free image over the lesion regions. Results: Although the center of gravity or affine algorithm achieved similar performance for individual lesion motion correction, the elastic model, applied either locally or to the whole FOV, led to an overall superior performance. The spatial tumor location was altered by 89% and 81% for the elastic model applied locally or to the whole FOV, respectively (compared to 44% and 39% for the center of gravity and affine models, respectively). This resulted in similar associated overall tumor volume changes of 84% and 80%, respectively (compared to 75% and 71% for the center of gravity and affine models, respectively). The application of the nonrigid deformation model in LRMC led to over an order of magnitude gain in computational efficiency of the correction relative to the application of the deformable model to the whole FOV. Conclusions: The results of this study support the use of LMRC as a flexible and efficient correction approach for respiratory motion effects for single lesions in the thoracic area.

60 APPLIED LIFE SCIENCES↗

Bias corrections of GOSAT SWIR XCO 2 and XCH 4 with TCCON data and their evaluation using aircraft measurement data

We describe a method for removing systematic biases of column-averaged dry air mole fractions of CO 2 (XCO 2 ) and CH 4 (XCH 4 ) derived from short-wavelength infrared (SWIR) spectra of the Greenhouse gases Observing SATellite (GOSAT). We conduct correlation analyses between the GOSAT biases and simultaneously retrieved auxiliary parameters. We use these correlations to bias correct the GOSAT data, removing these spurious correlations. Data from the Total Carbon Column Observing Network (TCCON) were used as reference values for this regression analysis. To evaluate the effectiveness of this correction method, the uncorrected/corrected GOSAT data were compared to independent XCO 2 and XCH 4 data derived from aircraft measurements taken for the Comprehensive Observation Network for TRace gases by AIrLiner (CONTRAIL) project, the National Oceanic and Atmospheric Administration (NOAA), the US Department of Energy (DOE), the National Institute for Environmental Studies (NIES), the Japan Meteorological Agency (JMA), the HIAPER Pole-to-Pole observations (HIPPO) program, and the GOSAT validation aircraft observation campaign over Japan. These comparisons demonstrate that the empirically derived bias correction improves the agreement between GOSAT XCO 2 /XCH 4 and the aircraft data. Finally, we present spatial distributions and temporal variations of the derived GOSAT biases.

54 ENVIRONMENTAL SCIENCES↗

Dual energy CT: How well can pseudo-monochromatic imaging reduce metal artifacts?

Purpose: Dual Energy CT (DECT) provides so-called monoenergetic images based on a linear combination of the original polychromatic images. At certain patient-specific energy levels, corresponding to certain patient- and slice-dependent linear combination weights, e.g., E = 160 keV corresponds to α = 1.57, a significant reduction of metal artifacts may be observed. The authors aimed at analyzing the method for its artifact reduction capabilities to identify its limitations. The results are compared with raw data-based processing. Methods: Clinical DECT uses a simplified version of monochromatic imaging by linearly combining the low and the high kV images and by assigning an energy to that linear combination. Those pseudo-monochromatic images can be used by radiologists to obtain images with reduced metal artifacts. The authors analyzed the underlying physics and carried out a series expansion of the polychromatic attenuation equations. The resulting nonlinear terms are responsible for the artifacts, but they are not linearly related between the low and the high kV scan: A linear combination of both images cannot eliminate the nonlinearities, it can only reduce their impact. Scattered radiation yields additional noncanceling nonlinearities. This method is compared to raw data-based artifact correction methods. To quantify the artifact reduction potential of pseudo-monochromatic images, they simulated the FORBILD abdomen phantom with metal implants, and they assessed patient data sets of a clinical dual source CT system (100, 140 kV Sn) containing artifacts induced by a highly concentrated contrast agent bolus and by metal. In each case, they manually selected an optimal α and compared it to a raw data-based material decomposition in case of simulation, to raw data-based material decomposition of inconsistent rays in case of the patient data set containing contrast agent, and to the frequency split normalized metal artifact reduction in case of the metal implant. For each case, the contrast-to-noise ratio (CNR) was assessed. Results: In the simulation, the pseudo-monochromatic images yielded acceptable artifact reduction results. However, the CNR in the artifact-reduced images was more than 60% lower than in the original polychromatic images. In contrast, the raw data-based material decomposition did not significantly reduce the CNR in the virtual monochromatic images. Regarding the patient data with beam hardening artifacts and with metal artifacts from small implants the pseudo-monochromatic method was able to reduce the artifacts, again with the downside of a significant CNR reduction. More intense metal artifacts, e.g., as those caused by an artificial hip joint, could not be suppressed. Conclusions: Pseudo-monochromatic imaging is able to reduce beam hardening, scatter, and metal artifacts in some cases but it cannot remove them. In all cases, the CNR is significantly reduced, thereby rendering the method questionable, unless special post processing algorithms are implemented to restore the high CNR from the original images (e.g., by using a frequency split technique). Raw data-based dual energy decomposition methods should be preferred, in particular, because the CNR penalty is almost negligible.

60 APPLIED LIFE SCIENCES↗

drtsans

drtsans is highly modular, allowing users to customize collected data as well as test hypothetical or simulated neutron events data. Instrument scientists can use the advance features of drtsans to calibrate their instruments and reduced large quantities of datasets in a streamlined mode. Users can correct the collected data with dark current subtraction and normalization by neutron flux, detector sensitivity, solid angle subtended by the detectors, and scaling to absolute units. Conversion from time-of-flight and/or wavelength to 1D or 2D momentum transfer renders the final scattering quantities amenable to analysis.

Bilheux, JeanC↗

EPCAPE-PT-LANL Measurements: Photoacoustic Extinctometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Photoacoustic Extinctiometer at 870 nm (Droplet Measurement Technology) Header: - AbsorptionNoise_870nm[1/Mm]: Noise level associated with the absorption measurement at 870 nm, expressed in inverse megameters (Mm⁻¹). - Absorption_870nm[1/Mm]: Absorption coefficient of aerosols measured at 870 nm, expressed in inverse megameters (Mm⁻¹). - Extinction_870nm[1/Mm]: Extinction coefficient of aerosols measured at 870 nm, expressing the sum of scattering and absorption by aerosols, in inverse megameters (Mm⁻¹). - Scattering_870nm[1/Mm]: Scattering coefficient of aerosols measured at 870 nm, expressed in inverse megameters (Mm⁻¹). - BackgroundAbsorption_870nm[1/Mm]: Background absorption measurement at 870 nm, used to correct the primary absorption data, expressed in inverse megameters (Mm⁻¹). - BackgroundScattering_870nm[1/Mm]: Background scattering measurement at 870 nm, used to correct the primary scattering data, expressed in inverse megameters (Mm⁻¹). - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement

54 ENVIRONMENTAL SCIENCES↗