Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Estimation of Rectal Dose Using Daily Megavoltage Cone-Beam Computed Tomography and Deformable Image Registration

Purpose: The actual dose delivered to critical organs will differ from the simulated dose because of interfractional organ motion and deformation. Here, we developed a method to estimate the rectal dose in prostate intensity modulated radiation therapy with consideration to interfractional organ motion using daily megavoltage cone-beam computed tomography (MVCBCT). Methods and Materials: Under exemption status from our institutional review board, we retrospectively reviewed 231 series of MVCBCT of 8 patients with prostate cancer. On both planning CT (pCT) and MVCBCT images, the rectal contours were delineated and the CT value within the contours was replaced by the mean CT value within the pelvis, with the addition of 100 Hounsfield units. MVCBCT images were rigidly registered to pCT and then nonrigidly registered using B-Spline deformable image registration (DIR) with Velocity AI software. The concordance between the rectal contours on MVCBCT and pCT was evaluated using the Dice similarity coefficient (DSC). The dose distributions normalized for 1 fraction were also deformed and summed to estimate the actual total dose. Results: The DSC of all treatment fractions of 8 patients was improved from 0.75±0.04 (mean ±SD) to 0.90 ±0.02 by DIR. Six patients showed a decrease of the generalized equivalent uniform dose (gEUD) from total dose compared with treatment plans. Although the rectal volume of each treatment fraction did not show any correlation with the change in gEUD (R{sup 2}=0.18±0.13), the displacement of the center of gravity of rectal contours in the anterior-posterior (AP) direction showed an intermediate relationship (R{sup 2}=0.61±0.16). Conclusion: We developed a method for evaluation of rectal dose using DIR and MVCBCT images and showed the necessity of DIR for the evaluation of total dose. Displacement of the rectum in the AP direction showed a greater effect on the change in rectal dose compared with the rectal volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray refraction-contrast computed tomography images using dark-field imaging optics

If an x-ray beam containing internal information derived from sample soft tissue is incident upon a Laue-case analyzer, the beam will subsequently split into a forwardly diffracted beam and a separate diffracted beam. Using these beams acquired simultaneously, a refraction-contrast computed tomography (CT) imaging system for biomedical use with lower radiation dose can be easily realized, and has a high depicting capability on the soft tissues compared with conventional x-ray CT based on absorption contrast principles. In this paper, we propose an imaging system using dark-field imaging for CT measurement based on a tandem system of Bragg- and Laue-case crystals with two two-dimensional detectors, along with a data-processing method to extract information on refraction from the measured entangled intensities by use of rocking curve fitting with polynomial functions. Reconstructed images of soft tissues are presented and described.

07 ISOTOPE AND RADIATION SOURCES↗

Coordinated neutron and X-ray computed tomography of meteorites: Detection and distribution of hydrogen-bearing materials

The presence and distribution of hydrogen-bearing materials in meteorites are important constraints on processes in the early solar system, and the delivery of volatile constituents to growing planets. Here, in this paper, we show that coordinated neutron and X-ray computed tomography, NXCT, can reveal the presence and distributions of hydrogen-bearing materials in meteorites, and thus help constrain the presence and actions of water in the early solar system. NXCT is nearly nondestructive of meteorite samples. Neutron fluence in NXCT is approximately seven orders of magnitude less than in typical instrumental neutron activation analysis, and so produces little residual radioactivity and currently undetectable changes in isotope ratios. Heating during NXCT is minimal, but NXCT will overprint the record of cosmic ray exposure held in natural thermoluminescence. Two meteorites were examined. EET 87503 is a howardite, a regolith breccia inferred to be from the asteroid 4 Vesta, and contains fragments of eucrite basalt, diogenite pyroxenite, and H-rich carbonaceous chondrites. With NXCT, the chondrite fragments within the meteorite piece can be clearly located and characterized, in preparation for possible extraction and detailed analyses. Graves Nunataks (GRA) 06100 is a CR2 chondrite meteorite that contains abundant iron metal and H-bearing silicates from aqueous alteration. In NXCT, H-bearing altered material is clearly distinguished from metal, and its distribution in three dimensions is revealed as a constraint on the processes of alteration.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct Simulations of Coupled Transport and Reaction on Nano-Scale X-Ray Computed Tomography Images of Platinum Group Metal-Free Catalyst Cathodes

The nano/micro-scale geometry of polymer electrolyte fuel cell (PEFC) catalyst layers critically affects cell performance. The small length scales and complex structure of these composite layers make it challenging to analyze cell performance and physics at the particle scale by experiment. We present a computational method to simulate transport and chemical reaction phenomena at the pore/particle-scale and apply it to a PEFC cathode with platinum group metal free (PGM-free) catalyst. Here, we numerically solve the governing equations for the physics with heterogeneous oxygen diffusion coefficient and proton conductivity evaluated using the actual electrode structure and ionomer distribution obtained using nano-scale resolution X-ray computed tomography (nano-CT). Using this approach, the oxygen concentration and electrolyte potential distributions imposed by the oxygen reduction reaction are solved and the impact of the catalyst layer structure on performance is evaluated.

36 MATERIALS SCIENCE↗

Feasibility study of endoscopic x-ray luminescence computed tomography: Simulation demonstration and phantom application

Even though endoscopic fluorescence diffuse optical tomography (eFDOT) exhibits significant potential, currently its application is limited due to the existence of strong autofluorescence and the imaging inaccuracy caused by a very short source-detector distance. Motivated by the emerging X-ray luminescence computed tomography (XLCT) technology, we presented an endoscopic XLCT (eXLCT) methodology. In the methodology, the aperture angle of the objective was incorporated into the forward model, providing a more accurate description of light propagation. Numerical simulation with a heterogeneous geometry and an imaging experiment with a physical phantom were illustrated to demonstrate the feasibility of the presented eXLCT methodology.

36 MATERIALS SCIENCE↗

High resolution computed tomography of advanced composite and ceramic materials

Advanced composite and ceramic materials are being developed for use in many new defense and commercial applications. In order to achieve the desired mechanical properties of these materials, the structural elements must be carefully analyzed and engineered. A study was conducted to evaluate the use of high resolution computed tomography (CT) as a macrostructural analysis tool for advanced composite and ceramic materials. Several samples were scanned using a laboratory high resolution CT scanner. Samples were also destructively analyzed at the locations of the scans and the nondestructive and destructive results were compared. The study provides useful information outlining the strengths and limitations of this technique and the prospects for further research in this area.

Yancey, R. N.↗

Quantifying Void Ratio Variation in Sand using Computed Tomography

A series of displacement-controlled, conventional, drained axisymmetric (triaxial) experiments were conducted on dry Ottawa sand specimens at very low effective confining stresses in a microgravity environment aboard the Space Shuttle during the NASA STS-89 mission. Post-flight analysis included studying the internal fabric and failure patterns of these specimens using Computed Tomography (CT). The CT scans of three specimens subjected to different compression levels (uncompressed specimen, a specimen compressed to 3.3% nominal axial strain (epsilon(sub a)), and a specimen compressed to 25% epsilon(sub a)) are presented to investigate the evolution of instability patterns and to quantify void ratio variation. The progress of failure is described and discussed. Also, specimens' densities were calibrated using standard ASTM procedures and void ratio spatial variation was calculated and represented by contour maps and histograms. The CT technique demonstrated good ability to detect specimen inhomogeneities, localization patterns, and quantifying void ratio variation within sand specimens.

Alshibli, Khalid A.↗

Contouring and Constraining Bowel on a Full-Bladder Computed Tomography Scan May Not Reflect Treatment Bowel Position and Dose Certainty in Gynecologic External Beam Radiation Therapy

Purpose: To evaluate, in a gynecologic cancer setting, changes in bowel position, dose-volume parameters, and biological indices that arise between full-bladder (FB) and empty-bladder (EB) treatment situations; and to evaluate, using cone beam computed tomography (CT), the validity of FB treatment presumption. Methods and Materials: Seventeen gynecologic cancer patients were retrospectively analyzed. Empty-bladder and FB CTs were obtained. Full-bladder CTs were used for planning and dose optimization. Patients were given FB instructions for treatment. For the study purpose, bowel was contoured on the EB CTs for all patients. Bowel position and volume changes between FB and EB states were determined. Full-bladder plans were applied on EB CTs for determining bowel dose-volume changes in EB state. Biological indices (generalized equivalent uniform dose and normal tissue complication probability) were calculated and compared between FB and EB. Weekly cone beam CT data were available in 6 patients to assess bladder volume at treatment. Results: Average (±SD) planned bladder volume was 299.7 ± 68.5 cm{sup 3}. Median bowel shift in the craniocaudal direction between FB and EB was 12.5 mm (range, 3-30 mm), and corresponding increase in exposed bowel volume was 151.3 cm{sup 3} (range, 74.3-251.4 cm{sup 3}). Absolute bowel volumes receiving 45 Gy were higher for EB compared with FB (mean 328.0 ± 174.8 vs 176.0 ± 87.5 cm{sup 3}; P=.0038). Bowel normal tissue complication probability increased 1.5× to 23.5× when FB planned treatments were applied in the EB state. For the study, the mean percentage value of relative bladder volume at treatment was 32%. Conclusions: Full-bladder planning does not necessarily translate into FB treatments, with a patient tendency toward EB. Given the uncertainty in daily control over bladder volume for treatment, we strongly recommend a “planning-at-risk volume bowel” (PRV{sub B}owel) concept to account for bowel motion between FB and EB that can be tailored for the individual patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Investigation of Hydrate Formation in Unsaturated Sediments Using X-Ray Computed Tomography

Physical properties of hydrate–bearing sediments are often correlated with hydrate saturation with little or no information on hydrate distribution uniformity in the specimens. This study focuses on water redistribution and sediment skeleton shift depending on various hydrate formation conditions in unsaturated systems, as well as on the resulting hydrate distribution patterns. Using X–ray computed tomography, we investigate the factors such as fines content and the pressure–temperature path on mass migration during carbon dioxide hydrate formation. The experiments show water migration, preferential hydrate formation toward the core periphery, localized patchy hydrate distribution, and sediment particle movement toward the core center. Sediment particle movement can be impeded in densely packed specimens. Furthermore, the overall mass migration due to hydrate formation can be significantly suppressed by adding 5% by mass of kaolinite. Hydrate formation initiated by pressurization and then cooling causes less mass migration than the cases where hydrate is formed using cooling followed by pressurization or pressurizing frozen cores followed by heating methods. Freezing can induce water migration and particle pushing in a similar manner as hydrate formation. Image analyses show that the pressure–temperature path and the rates of heat transfer during hydrate nucleation and growth govern the uniformity of hydrate distribution in sediments.

58 GEOSCIENCES↗

Computed Tomography Appearance of Early Radiation Injury to the Lung: Correlation With Clinical and Dosimetric Factors

Purpose: To systematically assess the spectrum of radiologic changes in the lung after radiation therapy for non-small-cell lung cancer. Methods and Materials: We reviewed the cases of 146 patients treated with radical radiotherapy at our institution. All patients had computed tomography (CT) scans performed 3 months after completion of therapy. Radiographic appearances were categorized using a standard grading system. The association of these abnormalities with pretreatment factors and clinical radiation pneumonitis (RP) was investigated. Results: New intrapulmonary abnormalities were seen in 92 patients (63%). These were ground-glass opacity in 16 (11%), patchy consolidation in 19 (13%), and diffuse consolidation in 57 (39%). Twenty-five patients (17%) developed clinical symptoms of RP. Although 80% of the patients with RP had areas of consolidation seen on the posttreatment CT scan, the majority (74%) of patients with such radiographic changes were asymptomatic. For patients with lung infiltrates, the minimum isodose encompassing the volume of radiologic abnormality was usually {>=}27 Gy. Traditional dose-volume metrics, pulmonary function tests, and the coadministration of angiotensin converting enzyme inhibitors (ACE-I) were all strongly correlated with the presence of radiologic injury on univariate analysis (p {<=} 0.002). There was also an inverse correlation between prior smoking history and CT scan changes (p = 0.02). On multivariate analysis, dosimetric parameters and the use of ACE-I retained significance (p = 0.005). Conclusions: Our findings suggest that there is substantial interindividual variation in lung radiosensitivity. ACE-I prevented the radiologic changes seen after high-dose radiation therapy, and their role as radioprotectants warrants further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Implementation of Intrafraction Cone Beam Computed Tomography Imaging During Lung Tumor Stereotactic Ablative Radiation Therapy

Purpose: To develop and clinically evaluate a volumetric imaging technique for assessing intrafraction geometric and dosimetric accuracy of stereotactic ablative radiation therapy (SABR). Methods and Materials: Twenty patients received SABR for lung tumors using volumetric modulated arc therapy (VMAT). At the beginning of each fraction, pretreatment cone beam computed tomography (CBCT) was used to align the soft-tissue tumor position with that in the planning CT. Concurrent with dose delivery, we acquired fluoroscopic radiograph projections during VMAT using the Varian on-board imaging system. Those kilovolt projections acquired during millivolt beam-on were automatically extracted, and intrafraction CBCT images were reconstructed using the filtered backprojection technique. We determined the time-averaged target shift during VMAT by calculating the center of mass of the tumor target in the intrafraction CBCT relative to the planning CT. To estimate the dosimetric impact of the target shift during treatment, we recalculated the dose to the GTV after shifting the entire patient anatomy according to the time-averaged target shift determined earlier. Results: The mean target shift from intrafraction CBCT to planning CT was 1.6, 1.0, and 1.5 mm; the 95th percentile shift was 5.2, 3.1, 3.6 mm; and the maximum shift was 5.7, 3.6, and 4.9 mm along the anterior-posterior, left-right, and superior-inferior directions. Thus, the time-averaged intrafraction gross tumor volume (GTV) position was always within the planning target volume. We observed some degree of target blurring in the intrafraction CBCT, indicating imperfect breath-hold reproducibility or residual motion of the GTV during treatment. By our estimated dose recalculation, the GTV was consistently covered by the prescription dose (PD), that is, V100% above 0.97 for all patients, and minimum dose to GTV >100% PD for 18 patients and >95% PD for all patients. Conclusions: Intrafraction CBCT during VMAT can provide geometric and dosimetric verification of SABR valuable for quality assurance and potentially for treatment adaptation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dedicated breast computed tomography: Basic aspects

X-ray mammography of the compressed breast is well recognized as the “gold standard” for early detection of breast cancer, but its performance is not ideal. One limitation of screening mammography is tissue superposition, particularly for dense breasts. Since 2001, several research groups in the USA and in the European Union have developed computed tomography (CT) systems with digital detector technology dedicated to x-ray imaging of the uncompressed breast (breast CT or BCT) for breast cancer screening and diagnosis. This CT technology—tracing back to initial studies in the 1970s—allows some of the limitations of mammography to be overcome, keeping the levels of radiation dose to the radiosensitive breast glandular tissue similar to that of two-view mammography for the same breast size and composition. This paper presents an evaluation of the research efforts carried out in the invention, development, and improvement of BCT with dedicated scanners with state-of-the-art technology, including initial steps toward commercialization, after more than a decade of R and D in the laboratory and/or in the clinic. The intended focus here is on the technological/engineering aspects of BCT and on outlining advantages and limitations as reported in the related literature. Prospects for future research in this field are discussed.

60 APPLIED LIFE SCIENCES↗

TH-AB-209-07: High Resolution X-Ray-Induced Acoustic Computed Tomography

Purpose: X-ray radiographic absorption imaging is an invaluable tool in medical diagnostics, biology and materials science. However, the use of conventional CT is limited by two factors: the detection sensitivity to weak absorption material and the radiation dose from CT scanning. The purpose of this study is to explore X-ray induced acoustic computed tomography (XACT), a new imaging modality, which combines X-ray absorption contrast and high ultrasonic resolution to address these challenges. Methods: First, theoretical models was built to analyze the XACT sensitivity to X-ray absorption and calculate the minimal radiation dose in XACT imaging. Then, an XACT system comprised of an ultrashort X-ray pulse, a low noise ultrasound detector and a signal acquisition system was built to evaluate the X-ray induced acoustic signal generation. A piece of chicken bone and a phantom with two golden fiducial markers were exposed to 270 kVp X-ray source with 60 ns exposure time, and the X-ray induced acoustic signal was received by a 2.25MHz ultrasound transducer in 200 positions. XACT images were reconstructed by a filtered back-projection algorithm. Results: The theoretical analysis shows that X-ray induced acoustic signals have 100% relative sensitivity to X-ray absorption, but not to X-ray scattering. Applying this innovative technology to breast imaging, we can reduce radiation dose by a factor of 50 compared with newly FDA approved breast CT. The reconstructed images of chicken bone and golden fiducial marker phantom reveal that the spatial resolution of the built XACT system is 350µm. Conclusion: In XACT, the imaging sensitivity to X-ray absorption is improved and the imaging dose is dramatically reduced by using ultrashort pulsed X-ray. Taking advantage of the high ultrasonic resolution, we can also perform 3D imaging with a single X-ray pulse. This new modality has the potential to revolutionize x-ray imaging applications in medicine and biology.

60 APPLIED LIFE SCIENCES↗

4D evolution of Cr 23 C 6 precipitates in neutron-irradiated and annealed HT-UPS steel observed via synchrotron micro-computed tomography

High-temperature-ultrafine precipitate strengthened (HT-UPS) steel is a potential structural material for advanced nuclear reactors; however, its irradiation response is not well understood. This research provides insight into irradiation-induced effects, such as precipitate evolution mechanisms and four-dimensional morphological evolution, in HT-UPS steel using synchrotron micro-computed tomography. Identical specimens were characterized pre-irradiation and post-irradiation following neutron exposure up to 0.3 displacements per atom at 600 °C. Irradiation effects were also differentiated from the annealing response of precipitates. Following neutron irradiation, the average Cr 23 C 6 precipitate size reduced, affected by the synergy of nucleation and growth, ballistic dissolution, and inverse coarsening, which was observed at fluences an order of magnitude lower than previously observed. Annealing at 600 °C for 32 h increased the average Cr 23 C 6 precipitate size and decreased the phase fraction, attributed to precipitate coarsening. The precipitate morphology evolution and resultant mechanisms can be utilized to parameterize and validate microstructural models simulating radiation damage or annealing.

36 MATERIALS SCIENCE↗

SU-F-T-320: Assessing Placement Error of Optically Stimulated Luminescent in Vivo Dosimeters Using Cone-Beam Computed Tomography

Purpose: Optically-stimulated luminescent dosimeters (OSLDs) are increasingly utilized for in vivo dosimetry of complex radiation delivery techniques such as intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). Evaluation of clinical uncertainties such as placement error has not been performed. This work retrospectively investigates the magnitude of placement error using conebeam computed tomography (CBCT) and its effect on measured/planned dose agreement. Methods: Each OSLD was placed at a physicist-designated location on the patient surface on a weekly basis. The location was given in terms of a gantry angle and two-dimensional offset from central axis. The OSLDs were placed before daily image guidance. We identified 77 CBCTs from 25 head-and-neck patients who received IMRT or VMAT, where OSLDs were visible on the CT image. Grossly misplaced OSLDs were excluded (e.g. wrong laterality). CBCTs were registered with the treatment plan and the distance between the planned and actual OSLD location was calculated in two dimensions in the beam’s eye view. Distances were correlated with measured/planned dose percent differences. Results: OSLDs were grossly misplaced for 5 CBCTs (6.4%). For the remaining 72 CBCTs, average placement error was 7.0±6.0 mm. These errors were not correlated with measured/planned dose percent differences (R{sup 2}=0.0153). Generalizing the dosimetric effect of placement errors may be unreliable. Conclusion: Correct placement of OSLDs for IMRT and VMAT treatments is critical to accurate and precise in vivo dosimetry. Small placement errors could produce large disagreement between measured and planned dose. Further work includes expansion to other treatment sites, examination of planned dose at the actual point of OSLD placement, and the influence of imageguided shifts on measured/planned dose agreement.

60 APPLIED LIFE SCIENCES↗

Synchrotron‐source micro‐x‐ray computed tomography for examining butterfly eyes

Comparative anatomy is an important tool for investigating evolutionary relationships among species, but the lack of scalable imaging tools and stains for rapidly mapping the microscale anatomies of related species poses a major impediment to using comparative anatomy approaches for identifying evolutionary adaptations. We describe a method using synchrotron source micro-x-ray computed tomography (syn-μXCT) combined with machine learning algorithms for high-throughput imaging of Lepidoptera (i.e., butterfly and moth) eyes. Our pipeline allows for imaging at rates of ~15 min/mm 3 at 600 nm 3 resolution. Image contrast is generated using standard electron microscopy labeling approaches (e.g., osmium tetroxide) that unbiasedly labels all cellular membranes in a species-independent manner thus removing any barrier to imaging any species of interest. To demonstrate the power of the method, we analyzed the 3D morphologies of butterfly crystalline cones, a part of the visual system associated with acuity and sensitivity and found significant variation within six butterfly individuals. Despite this variation, a classic measure of optimization, the ratio of interommatidial angle to resolving power of ommatidia, largely agrees with early work on eye geometry across species. We show that this method can successfully be used to determine compound eye organization and crystalline cone morphology. Our novel pipeline provides for fast, scalable visualization and analysis of eye anatomies that can be applied to any arthropod species, enabling new questions about evolutionary adaptations of compound eyes and beyond.

59 BASIC BIOLOGICAL SCIENCES↗

Do We Need Daily Image-Guided Radiotherapy by Megavoltage Computed Tomography in Head and Neck Helical Tomotherapy? The Actual Delivered Dose to the Spinal Cord

Purpose: To quantify the actual delivered dose to the cervical spinal cord with different image-guided radiotherapy (IGRT) approaches during head and neck (HN) cancer helical tomotherapy. Methods and Materials: Twenty HN patients (HNpts) treated with bilateral nodal irradiation were analyzed. Daily megavoltage computed tomography MVCT) scans were performed for setup purposes. The maximum dose on the planning CT scan (plan-Dmax) and the magnitude and localization of the actual delivered Dmax (a-Dmax) were analyzed for four scenarios: daily image-guided radiotherapy (dIGRT), twice weekly IGRT (2 Multiplication-Sign WkIGRT), once weekly IGRT (1 Multiplication-Sign WkIGRT), and no IGRT at all (non-IGRT). The spinal cord was recontoured on 236 MVCTs for each scenario (total, 944 fractions), and the delivered dose was recalculated for each fraction (fx) separately. Results: Fifty-one percent of the analyzed fx for dIGRT, 56% of the analyzed fx for the 2 Multiplication-Sign WkIGRT, 62% of the analyzed fx for the 1 Multiplication-Sign WkIGRT, and 63% of the analyzed fx for the non-IGRT scenarios received a higher a-Dmax than the plan-Dmax. The median increase of dose in these fx was 3.3% more for dIGRT, 5.8% more for 2 Multiplication-Sign WkIGRT, 10.0% more for 1 Multiplication-Sign WkIGRT, and 9.5% more for non-IGRT than the plan-Dmax. The median spinal cord volumes receiving a higher dose than the plan-Dmax were 0.02 cm{sup 3} for dIGRT, 0.11 cm{sup 3} for 2 Multiplication-Sign WkIGRT, 0.31 cm{sup 3} for 1 Multiplication-Sign WkIGRT, and 0.22 cm{sup 3} for non-IGRT. Differences between the dIGRT and all other scenarios were statistically significant (p < 0.05). Conclusions: Compared to the Dmax of the initial plan, daily IGRT had the smallest increase in dose. Furthermore, daily IGRT had the lowest proportion of fractions and the smallest volumes affected by a dose that was higher than the planned dose. For patients treated with doses close to the tolerance dose of the spinal cord, we recommend daily IGRT. For all other cases, twice weekly IGRT is sufficient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutron radiography and X-ray computed tomography for quantifying weathering and water uptake processes inside porous limestone used as building material

Euville and Savonnières limestones were weathered by acid test and this resulted in the formation of a gypsum crust. In order to characterize the crystallization pattern and the evolution of the pore structure below the crust, a combination of high resolution X-ray computed tomography and SEM–EDS was used. A time lapse sequence of the changing pore structure in both stones was obtained and afterwards quantified by using image analysis. The difference in weathering of both stones by the same process could be explained by the underlying microstructure and texture. Because water and moisture play a crucial role in the weathering processes, water uptake in weathered and non-weathered samples was characterized based on neutron radiography. In this way the water uptake was both visualized and quantified in function of the height of the sample and in function of time. In general, the formation of a gypsum crust on limestone slows down the initial water uptake in the materials. - Highlights: • Time lapse sequence in 3D of changing pore structures inside limestone • A combination of X-ray CT, SEM and neutron radiography was used. • Quantification of water content in function of time, height and weathering • Characterization of weathering processes due to gypsum crystallization.

36 MATERIALS SCIENCE↗