Tissue decomposition from dual energy CT data for MC based dose calculation in particle therapy

Purpose: The authors describe a novel method of predicting mass density and elemental mass fractions of tissues from dual energy CT (DECT) data for Monte Carlo (MC) based dose planning. Methods: The relative electron density ϱ{sub e} and effective atomic number Z{sub eff} are calculated for 71 tabulated tissue compositions. For MC simulations, the mass density is derived via one linear fit in the ϱ{sub e} that covers the entire range of tissue compositions (except lung tissue). Elemental mass fractions are predicted from the ϱ{sub e} and the Z{sub eff} in combination. Since particle therapy dose planning and verification is especially sensitive to accurate material assignment, differences to the ground truth are further analyzed for mass density, I-value predictions, and stopping power ratios (SPR) for ions. Dose studies with monoenergetic proton and carbon ions in 12 tissues which showed the largest differences of single energy CT (SECT) to DECT are presented with respect to range uncertainties. The standard approach (SECT) and the new DECT approach are compared to reference Bragg peak positions. Results: Mean deviations to ground truth in mass density predictions could be reduced for soft tissue from (0.5±0.6)% (SECT) to (0.2±0.2)% with the DECT method. Maximum SPR deviations could be reduced significantly for soft tissue from 3.1% (SECT) to 0.7% (DECT) and for bone tissue from 0.8% to 0.1%. MeanI-value deviations could be reduced for soft tissue from (1.1±1.4%, SECT) to (0.4±0.3%) with the presented method. Predictions of elemental composition were improved for every element. Mean and maximum deviations from ground truth of all elemental mass fractions could be reduced by at least a half with DECT compared to SECT (except soft tissue hydrogen and nitrogen where the reduction was slightly smaller). The carbon and oxygen mass fraction predictions profit especially from the DECT information. Dose studies showed that most of the 12 selected tissues would profit significantly (up to 2.2%) from DECT material decomposition with no noise present. The ϱ{sub e} associated with an absolute noise of ±0.01 and Z{sub eff} associated with an absolute noise of ±0.2 resulted in ±10% standard variation in the carbon and oxygen mass fraction prediction. Conclusions: Accurate stopping power prediction is mainly determined by the correct mass density prediction. Theoretical improvements in range predictions with DECT data in the order of 0.1%–2.1% were observed. Further work is needed to quantify the potential improvements from DECT compared to SECT in measured image data associated with artifacts and noise.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of novel concepts of power transmission gears

Two concepts in power transmission gear design are proposed which provide a potential for large noise reduction and for improving weight to payload ratio due to use of advanced fiber reinforced and ceramic materials. These concepts are briefly discussed. Since both concepts use ultrathin layered rubber-metal laminates for accommodating limited travel displacements, properties of the laminates, such as their compressive strength, compressive and shear moduli were studied. Extensive testing and computational analysis were performed on the first concept gears (laminate coated conformal gears). Design and testing of the second conceptual design (composite gear with separation of sliding and rolling motions) are specifically described.

Rivin, Eugene I.↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Information depth in backscattered electron microscopy of nanoparticles within a solid matrix

Highlights: • Backscattered electron microscopy was used for reliable determination of nanoparticle density and sizes within Al alloys • Backscattered electron information depth was determined as a function of nanoparticle size from Monte Carlo simulations • Unlike transmission electron microscopy, the method is non-destructive and allows analyzing large sample areas • Good agreement with transmission electron microscopy data shows that our method is suitable for nanocomposite materials - Abstract: Measuring the dimensions and number density of nanoparticles dispersed in a solid matrix is usually accomplished via transmission electron microscopy (TEM) which suffers from high cost, low throughput, and small analytical volume. In comparison, scanning backscattered electron microscopy is inexpensive, requires little sample preparation, and allows for the analysis of large sample areas. However, the information depth is usually not known precisely and depends on several factors such as the composition of the nanoparticles and the matrix as well as the size of the nanoparticles, hindering the reconstruction of the actual size distribution and three-dimensional number density. Here we present a method to estimate the information depth for spherical nanoparticles of different sizes in order to accurately determine size distribution and number density. The approach is based on Monte Carlo simulation of electron trajectories in the material and analysis of the obtained backscattered electron signal-to-noise-ratio. Our experimental results are compared to those obtained via TEM and good agreement is demonstrated; this shows that TEM can be replaced by scanning electron microscopy for studying nanocomposites in many cases.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Image processing pipeline for AI-driven nanoparticle megalibrary characterization

Recent innovations have made it possible to produce megalibraries, millions of structurally and compositionally distinct nanoparticles on a chip. These megalibraries yield vast volumes of data that are impossible to analyze manually, necessitating the development of automated tools. In previous work, we created a binary classification machine learning model to select quality nanoparticle images for downstream analysis. In this work, we show that adding a custom image processing step before training can produce significantly higher-performing models in a fraction of the time and make them more robust to different image noise levels and microscope acquisition settings. The image processing pipeline proposed here effectively cleans raw nanoparticle images, enhances key features, and allows us to use much lower resolution images and simpler neural network model architectures. These features result in higher performance and significant cost savings. Experiments demonstrate superior performance relative to baseline, including an 18.2% improvement in recall and a 13.1% increase in accuracy. Given the high cost of downstream analysis, it is critical to minimize false positives, and our best-performing model reaches a precision of 95.9% and a weighted F-score of 95.1% on an unseen test set. Additionally, model training time is reduced from hours to less than a minute. We also show that, using this custom image processing pipeline, model performance is significantly improved at lower pixel resolutions compared to downsizing alone. We expect that adopting this pipeline for AI-driven automated nanoparticle characterization will allow researchers to rapidly and accurately analyze much greater volumes of data, thereby accelerating materials discovery.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Squeezed Light Stimulated Raman Scattering (SRS) Microscopy for Bioenergy Applications

Stimulated Raman scattering (SRS) microscopy using picosecond near-IR pulses have provided a great penetration depth with reduced fluorescence interference when imaging biological samples for bioenergy applications. These tools have provided insight into 1) tracking the degradation of chemical composites in biomass feedstocks to investigate the recalcitrant factors during the deconstruction processes, 2) monitoring the production of chemicals in photosynthetic plants and wood-digesting microorganisms, and 3) probing plant-bacteria interactions. However, the above processes are usually slow and require continuous imaging for an extended period. This is challenging for classic SRS because the laser power needed to achieve enough sensitivity causes photodamage in the samples during such long experiments. Quantum-squeezed light with reduced noise in the intensity quadrature can improve the sensitivity of classic SRS microscopy beyond the shot noise limit. The successful squeezing of one of the picosecond pulses in the above SRS will improve sensitivity and reduce photodamage, greatly expanding the range of studies available to SRS microscopy.

BIOMASS FUELS↗

The development of advanced technology blades for tilt-rotor aircraft

The paper discusses the development and ground testing of blades for the XV-15 tilt-rotor demonstrator aircraft. This work was performed under contract NAS2-11250 with NASA Ames Research Center. These blades, known as the Advanced Technology Blades (ATB), replace the rectangular, steel blades which were part of the XV-15 original design. The materials used in the primary structure of the ATB are fiberglass and high strain graphite epoxy laminates. This facilitates the use of 43 deg of nonlinear twist, a nonuniform tapered planform and thin airfoils required for aerodynamic efficiency. Instrumentation life is extended by encapsulating gages and wiring in the composite structure. Tip shells and cuff fairings are removable to provide access to tip weights and retention hardware; they are also replaceable with alternate research configurations. Extensive laboratory testing has validated predicted strength characteristics. Hover testing has demonstrated performance significantly superior to that predicted by contemporary methodology. Key elements of the test rig used for rotor performance measurement were developed as an ancillary part of the present program. The performance testing included measurement of near- and far-field noise. Induced inflow velocity distributions were also determined and photographs of tip vortex condensation trails were taken. These are providing guidance for modifications to hover peformance codes.

Alexander, Harold R.↗

Aligning a Receiving Antenna Array to Reduce Interference

A digital signal-processing algorithm has been devised as a means of aligning (as defined below) the outputs of multiple receiving radio antennas in a large array for the purpose of receiving a desired weak signal transmitted by a single distant source in the presence of an interfering signal that (1) originates at another source lying within the antenna beam and (2) occupies a frequency band significantly wider than that of the desired signal. In the original intended application of the algorithm, the desired weak signal is a spacecraft telemetry signal, the antennas are spacecraft-tracking antennas in NASA s Deep Space Network, and the source of the wide-band interfering signal is typically a radio galaxy or a planet that lies along or near the line of sight to the spacecraft. The algorithm could also afford the ability to discriminate between desired narrow-band and nearby undesired wide-band sources in related applications that include satellite and terrestrial radio communications and radio astronomy. The development of the present algorithm involved modification of a prior algorithm called SUMPLE and a predecessor called SIMPLE. SUMPLE was described in Algorithm for Aligning an Array of Receiving Radio Antennas (NPO-40574), NASA Tech Briefs Vol. 30, No. 4 (April 2006), page 54. To recapitulate: As used here, aligning signifies adjusting the delays and phases of the outputs from the various antennas so that their relatively weak replicas of the desired signal can be added coherently to increase the signal-to-noise ratio (SNR) for improved reception, as though one had a single larger antenna. Prior to the development of SUMPLE, it was common practice to effect alignment by means of a process that involves correlation of signals in pairs. SIMPLE is an example of an algorithm that effects such a process. SUMPLE also involves correlations, but the correlations are not performed in pairs. Instead, in a partly iterative process, each signal is appropriately weighted and then correlated with a composite signal equal to the sum of the other signals.

Jongeling, Andre P.↗

Observing signals of spectral features in the cosmic-ray positrons and electrons from Milky Way pulsars

The Alpha Magnetic Spectrometer (AMS-02) has provided unprecedented precision measurements of the electron and positron cosmic-ray fluxes and the positron fraction spectrum. At the higher energies, sources as energetic local pulsars, may contribute to both cosmic-ray species. The discreteness of the source population, can result in features both on the positron fraction measurement and in the respective electron and positron spectra. For the latter, those would coincide in energy and would contrast predictions of smooth spectra as from particle dark matter. In this work, using a library of pulsar population models for the local part of the Milky Way, we perform a power-spectrum analysis on the cosmic-ray positron fraction. We also develop a technique to cross-correlate the electron and positron fluxes. We show that both such analyses, can be used to search statistically for the presence of spectral wiggles in the cosmic-ray data. For a significant fraction of our pulsar simulations, those techniques are already sensitive enough to give a signal for the presence of those features above the regular noise, with forthcoming observations making them even more sensitive. Lastly, by cross-correlating the AMS-02 electron and positron spectra, we find an intriguing first hint for a positive correlation between them, of the kind expected by a population of local pulsars.

79 ASTRONOMY AND ASTROPHYSICS↗

Mineralogic information from a new airborne thermal infrared multispectral scanner

The thermal IR multispectral scanner (TIMS) has been developed for airborne geologic surveys. The resststrahlen band between 8-11 microns is exhibited by interatomic stretching vibrations of Si and oxygen bound up in the crystal lattice of silicate rocks. The crystal structure of the component minerals influence the depth and position of the detected band. The TIMS has six channels, an 80 deg field of view, and a sensitivity sufficient to detect a noise equivalent change in spectral emissivity of 0.002-0.006. The six bands measured are 8.2-8.6, 8.6-9.0, 9.4-10.2, 10.2-11.2, and 11.2-12.2 microns, using HgCdTe detectors. The data are analyzed with respect to emissivity variations as a function of wavelength, using the component transformation technique called a decorrelation stretch, with spectral differences being displayed as different colors. Sample scenes from Death Valley and the Nevada Cuprite mining district are compared with visible and near-IR color composites of the same areas, revealing the superior distinctions that are available with the TIMS.

Kahle, A. B.↗

Thermal Infrared Spectral Band Detection Limits for Unidentified Surface Materials

Infrared emission spectra recorded by airborne or satellite spectrometers can be searched for spectral features to determine the composition of rocks on planetary surfaces. Surface materials are identified by detections of characteristic spectral bands. We show how to define whether to accept an observed spectral feature as a detection when the target material is unknown. We also use remotely sensed spectra measured by the Thermal Emission Spectrometer (TES) and the Spatially Enhanced Broadband Array Spectrograph System to illustrate the importance of instrument parameters and surface properties on band detection limits and how the variation in signal-to-noise ratio with wavelength affects the bands that are most detectable for a given instrument. The spectrometer's sampling interval, spectral resolution, signal-to-noise ratio as a function of wavelength, and the sample's surface properties influence whether the instrument can detect a spectral feature exhibited by a material. As an example, in the 6-13 micrometer wavelength region, massive carbonates exhibit two bands: a very strong, broad feature at approximately 6.5 micrometers and a less intense, sharper band at approximately 11.25 micrometers. Although the 6.5-micrometer band is stronger and broader in laboratory-measured spectra, the 11.25-micrometer band will cause a more detectable feature in TES spectra.

Kirkland, Laurel E.↗

NASA Tech Briefs, August 2009

Topics covered include: Aligning a Receiving Antenna Array to Reduce Interference; Collecting Ground Samples for Balloon-Borne Instruments; Tethered Pyrotechnic Apparatus for Acquiring a Ground Sample; Enhanced Video-Oculography System; Joint Carrier-Phase Synchronization and LDPC Decoding; Dual-Polarization, Sideband-Separating, Balanced Receiver for 1.5 THz Modular Battery Charge Controller; Efficient Multiplexer FPGA Block Structures Based on G4FETs; VLSI Microsystem for Rapid Bioinformatic Pattern Recognition; Low-Noise Amplifier for 100 to 180 GHz; Improved Fabrication of Ceramic Matrix Composite/Foam Core Integrated Structures; Inert Welding/Brazing Gas Filters and Dryers; Fabricating Copper Nanotubes by Electrodeposition; Reducing Aerodynamic Drag on Empty Open Cargo Vehicles; Rotary Percussive Auto-Gopher for Deep Drilling and Sampling; More About Reconfigurable Exploratory Robotic Vehicles; Thermostatic Valves Containing Silicone-Oil Actuators; Improving Heat Flux Performance of Flat Surface in Spray-Cooling Systems; Treating Fibrous Insulation to Reduce Thermal Conductivity; Silica-Aerogel Composites Opacified with La(sub0.7)Sr(sub0.3)MnO3; Cyclic Oxidation Behavior of CuCrAl Cold-Sprayed Coatings for Reusable Launch Vehicles; Ceramic Fiber Structures for Cryogenic Load-Bearing Applications; Elastomer Reinforced with Carbon Nanotubes; Biologically Inspired Purification and Dispersion of SWCNTs; A Technique for Adjusting Eigenfrequencies of WGM Resonators; Low-Pressure, Field-Ionizing Mass Spectrometer; Modifying Operating Cycles to Increase Stability in a LITS; Chamber for Simulating Martian and Terrestrial Environments; Algorithm for Detecting a Bright Spot in an Image; Extreme Programming: Maestro Style; Adaptive Behavior for Mobile Robots; Protocol for Communication Networking for Formation Flying; Planning Complex Sequences Using Compressed Representations; and Self-Supervised Learning of Terrain Traversability from Proprioceptive Sensors.

Source record↗

Post-Landing Major Element Quantification Using SuperCam Laser Induced Breakdown Spectroscopy

The SuperCam instrument on the PerseveranceMars 2020 rover uses a pulsed 1064 nm laser to ablate targets at a distance and conduct laser induced breakdown spectroscopy (LIBS) by analyzing the light from the resulting plasma. SuperCam LIBS spectra are preprocessed to remove ambient light, noise, and the continuum signal present in LIBS observations. Prior to quantification, spectra are masked to remove noisier spectrometer regions andspectra are normalized to minimize signal fluctuations and effectsof target distance.In some cases, the spectra are also standardized or binned prior to quantification. To determine quantitative elemental compositionsof diverse geologic materials at Jezero crater, Mars, we use a suite of 1198 laboratory spectra of 334 well-characterized reference samples. The samples were selected to span a wide range of compositions and include typical silicate rocks, pure minerals (e.g.,silicates, sulfates, carbonates, oxides),more unusual compositions (e.g.,Mn oreand sodalite), andreplicates of the sintered SuperCam calibration targets (SCCTs) onboardthe rover. For each major element (SiO2, TiO2, Al2O3, FeOT, MgO, CaO, Na2O, K2O), the database was subdivided into five“folds” with similar distributions of the element of interest. One fold was held out as an independent test set, and the remaining fourfolds were used to optimize multivariate regression models relating the spectrum to the composition. We considered a variety of models, and selected several for further investigation for each element, based primarily on the root mean squared error of prediction (RMSEP) on the test set, when analyzed at 3m. In cases with several models of comparable performance at 3 m, we incorporated the SCCT performance at different distances to choose the preferred model. Shortly after landing on Mars and collecting initial spectra of geologic targets, we selected one model per element. Subsequently, with additional data from geologic targets, some models were revised to ensure results that are more consistent with geochemical constraints. The calibration discussed here is a snapshot of an ongoing effort to deliver the most accurate chemical compositions with SuperCam LIBS.

Mars 2020↗

Development of an instrument for non-destructive identification of Unexploded Ordnance using tagged neutrons - a proof of concept study

Range clearance operations at munitions testing grounds must discriminate Unexploded Ordnance (UXO) from clutter items and distinguish UXO filled with High Explosives (HE) from those with inert fillers. Non-destructive technologies are thus necessary for the cost-effective disposal of UXO during remediation of such sites. The only technique showing promise so far for the non-destructive elemental characterization of UXO fillers utilizes neutron interactions with the material to detect carbon (C), nitrogen (N) and oxygen (O) which have unique ratios in HE. However, several unresolved issues hinder the wide application of this potentially very suitable technique. The most important one is that neutrons interact with all surrounding matter in addition to the interrogated material, leading to a very high gamma-ray background in the detector. Systems requiring bulky shielding and having poor signal-to-noise ratios (SNRs) for measuring elements are unsuitable for field deployment. The inadequacies of conventional neutron interrogation methods are overcome by using the tagged-neutron approach, and the availability of compact sealed neutron generators exploiting this technique offers field deployment of non-intrusive measurement systems for detecting threat materials, like explosives and drugs. By accelerating deuterium ions into a tritium target, the subsequent fusion reaction generates nearly back-to-back emissions of neutrons and alpha particles of energy 14.1 and 3.5 MeV respectively. A position-sensitive detector recognizes the associated alpha particle, thus furnishing the direction of the neutron. The tagged neutrons interact with the nuclei of the interrogated object, producing element-specific prompt gamma-rays that the gamma detectors recognize. Measuring the delay between the detections of the alpha particle and the gamma-ray determines where the reaction occurred along the axis of the neutron beam (14.1 MeV neutrons travel at 5 cm/nanosecond, while gamma rays cover 30 cm/nanosecond). The main advantage of the technique is its ability to simultaneously provide 2D and 3D imaging of objects and their elemental composition. This work reports on the efficacy of using 14 MeV neutrons tagged by the associated particle neutron time-of-flight technique (APnTOF) to extract neutron induced characteristic gamma-rays from an object-of-interest with high SNR and without interference from nearby clutter.

54 ENVIRONMENTAL SCIENCES↗

Systematic study of variation in radiation data in cluttered environments

There are many challenges to overcome during nuclear nonproliferation measurements, including a wide variety of clutter sources that may be introduced into a scene during acquisition. The ability to understand how the dissimilarity of various objects, or clutter, obscures a detector’s field of view and affects the measured response of the detector improves the input to detection alarm and nuclide identification algorithms. Additionally, having the capability to input clutter variation into radiation transport models would allow for more real-world scenarios to be modeled and understood. Efforts at Oak Ridge National Laboratory have been exploring the ability to determine specific natural background radiation contributions from surroundings, such as buildings, soil, asphalt, and concrete, and use those source terms in large-scale (100 + m) models. The capability to quantify different clutter terms, ranging from humans to large vehicles, allows researchers to inject realistic noise into these models. The work reported herein seeks to explore the effects that clutter introduces to quantify the expected signal variation inherent to both controlled and uncontrolled scenarios, specifically how the introduction of clutter into a scene introduces a variation in signals due to the attenuation of naturally occurring radioactive material distributed within the scene or by introducing non-threatening radioactive materials into the scene. Controlled measurements aim to quantify how different types of clutter of varying size and composition affects the response of a radiation detector. Using results from various controlled tests, the systematic effects of clutter and its effect on radiation readings is analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Task-based weights for photon counting spectral x-ray imaging

Purpose: To develop a framework for taking the spatial frequency composition of an imaging task into account when determining optimal bin weight factors for photon counting energy sensitive x-ray systems. A second purpose of the investigation is to evaluate the possible improvement compared to using pixel based weights. Methods: The Fourier based approach of imaging performance and detectability index d' is applied to pulse height discriminating photon counting systems. The dependency of d' on the bin weight factors is made explicit, taking into account both differences in signal and noise transfer characteristics across bins and the spatial frequency dependency of interbin correlations from reabsorbed scatter. Using a simplified model of a specific silicon detector, d' values for a high and a low frequency imaging task are determined for optimal weights and compared to pixel based weights. Results: The method successfully identifies bins where a large point spread function degrades detection of high spatial frequency targets. The method is also successful in determining how to downweigh highly correlated bins. Quantitative predictions for the simplified silicon detector model indicate that improvements in the detectability index when applying task-based weights instead of pixel based weights are small for high frequency targets, but could be in excess of 10% for low frequency tasks where scatter-induced correlation otherwise degrade detectability. Conclusions: The proposed method makes the spatial frequency dependency of complex correlation structures between bins and their effect on the system detective quantum efficiency easier to analyze and allows optimizing bin weights for given imaging tasks. A potential increase in detectability of double digit percents in silicon detector systems operated at typical CT energies (100 kVp) merits further evaluation on a real system. The method is noted to be of higher relevance for silicon detectors than for cadmium (zink) telluride detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical detection of pulsed surface particle displacements

The detection of acoustic surface wave pulses by a wideband differential interferometric laser technique which is insensitive to low frequency noise is described. System bandwidth is determined by the relationship between acoustic wavelength and the variable spacing between two laser probe beams focused on the solid surface which supports the waves. Theoretical sensitivity to surface displacement amplitude is equal to, or better than, that of other electrooptical techniques. Response to an ideal step function displacement is analyzed and experimental measurements of gated 2.5 MHz pulses generated on an aluminized pyrex plate are discussed. Potential application in the characterization of acoustic emission in composites is described.

Zerwekh, P. S.↗

Mixing and Transition Control Studied

Considerable progress in understanding nonlinear phenomena in both unbounded and wallbounded shear flow transition has been made through the use of a combination of high- Reynolds-number asymptotic and numerical methods. The objective of this continuing work is to fully understand the nonlinear dynamics so that ultimately (1) an effective means of mixing and transition control can be developed and (2) the source terms in the aeroacoustic noise problem can be modeled more accurately. Two important aspects of the work are that (1) the disturbances evolve from strictly linear instability waves on weakly nonparallel mean flows so that the proper upstream conditions are applied in the nonlinear or wave-interaction streamwise region and (2) the asymptotic formulations lead to parabolic problems so that the question of proper out-flow boundary conditions--still a research issue for direct numerical simulations of convectively unstable shear flows--does not arise. Composite expansion techniques are used to obtain solutions that account for both mean-flow-evolution and nonlinear effects. A previously derived theory for the amplitude evolution of a two-dimensional instability wave in an incompressible mixing layer (which is in quantitative agreement with available experimental data for the first nonlinear saturation stage for a plane-jet shear layer, a circular-jet shear layer, and a mixing layer behind a splitter plate) have been extended to include a wave-interaction stage with a three-dimensional subharmonic. The ultimate wave interaction effects can either give rise to explosive growth or an equilibrium solution, both of which are intimately associated with the nonlinear self-interaction of the three dimensional component. The extended theory is being evaluated numerically. In contrast to the mixing-layer situation, earlier comparisons of theoretical predictions based on asymptotic methods and experiments in wall-bounded shear-flow transition have been somewhat lacking in one aspect or another. The current work strongly suggests that the main weakness is the underlying asymptotic representation of the linear "part" of the problem and not the explicit modeling of the nonlinear/wave-interaction effects. Consequently, the long-wave-length/high-Reynolds-number asymptotic limit for the Blasius boundary-layer stability problem was reexamined, and a new dispersion relationship for the instability waves that is uniformly valid for both the upper- and lower branch regions to the required order of approximation was obtained. A comparison with numerical results, obtained by solving the Orr-Sommerfeld stability problem, shows that the asymptotic formula provides surprisingly good results, even for values of the frequency parameter usually encountered in experimental investigations. This is particularly evident in the dynamically important upper-branch region, where much of the nonlinear interactions in transition experiments are believed to take place. The result is important in that it can be used to greatly improve the accuracy of weakly nonlinear critical-layer-based theories, and a consistent nonlinear theory is currently under evaluation.

Source record↗