Pipeline Monitoring Using Highly Sensitive Vibration Sensor Based on Fiber Ring Cavity Laser

A vibration fiber sensor based on a fiber ring cavity laser and an interferometer based single-mode-multimode-single-mode (SMS) fiber structure is proposed and experimentally demonstrated. The SMS fiber sensor is positioned within the laser cavity, where the ring laser lasing wavelength can be swept to an optimized wavelength using a simple fiber loop design. To obtain a better signal-to-noise ratio, the ring laser lasing wavelength is tuned to the maximum gain region biasing point of the SMS transmission spectrum. A wide range of vibration frequencies from 10 Hz to 400 kHz are experimentally demonstrated. In addition, the proposed highly sensitive vibration sensor system was deployed in a field-test scenario for pipeline acoustic emission monitoring. An SMS fiber sensor is mounted on an 18” diameter pipeline, and vibrations were induced at different locations using a piezoelectric transducer. The proposed method was shown to be capable of real-time pipeline vibration monitoring.

47 OTHER INSTRUMENTATION↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 W/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 W/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky nights monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs was calculated using NREL equation and the CG4 using NREL equation and PMOD/WRC equation. Using the NREL equation, the calculated uncertainty (U_95) of the PIRs varied from 2.43 W/m2 to 2.67 W/m2, and for the CG4 using the NREL equation U_95 equals 1.97 W/m2, and using the PMOD equation U_95 equals 2.88 W/m2 with respect to SI.

International System of Units↗

OPERATIONAL EXPERIENCE AND REDESIGN OF THE TUNER WITH-OUT SPRING FINGERS FOR THE LEReC WARM CAVITY

A folded coaxial tuner without spring fingers was de-signed for the Low Energy Relativistic Heavy Ion Collider (RHIC) electron Cooler (LEReC) 2.1 GHz warm cavity. During RHIC run 2019, this tuner was found to cause cavity trips via different failure modes. After analyzing these failure modes, a new straight coaxial tuner without spring fingers was proposed and was installed. We show the operational experience of the new tuner in this paper.

43 PARTICLE ACCELERATORS↗

Fabrication experience of the pre-production PIP-II SSR2 cavities at Fermilab

The Proton Improvement Plan-II (PIP-II, [1]) linac will include 35 Single Spoke Resonators type 2 (SSR2). A total of eight pre-production SSR2 jacketed cavities will be procured and five installed in the first pre-production cryomodule. The mechanical design of the jacketed cavity has been finalized and it will be presented in this paper along with fabrication and processing experience. The importance of interfaces, quality controls and procurement aspects in the design phase will be remarked as well as lessons learned during the fabrication process. Furthermore, development studies will be presented together with other design validation tests.

43 PARTICLE ACCELERATORS↗

Niobium to Titanium Electron Beam Welding for SRF Cavities

Titanium and niobium are the main materials used for the fabrication of Superconducting Radio Frequency (SRF) cavities. These two metals are usually joined , using various welding techniques, using a third material in between. This contribution focuses on the development of an innovative electron beam welding technique capable of producing a strong bond between these two different materials. Several samples are produced and tested to assess the mechanical strength at room and cryogenic temperature as well as the composition of the resulting welded joint. Also, the first units of the Single Spoke Resonator type 2 (SSR2) cavities for the Proton Improvement Plan-II (PIP-II [1]) have been fabricated joining directly various grades of titanium to niobium and results gathered through the fabrication will be reported.

43 PARTICLE ACCELERATORS↗

Micro cavity fission chamber radiation detection system

A radiation detector to monitor the neutron flux of a nuclear reactor or other high-radiation environment, that can withstand the high temperatures and radiation fields of such environment, is provided. A small dielectric substrate with a low neutron-activation cross section is provided. The substrate is coated with a neutron conversion material, such as uranium oxide or thorium oxide. One or more substrates form a micro-sized detection cavity that is filled with a detection gas. A voltage is provided across anode and cathode wires in the detection cavity. A neutron absorbed in the conversion material may release reaction products into the gas, causing ionization of the gas which then produces a current or voltage signal. The small detector volume minimizes energy deposition into the detection gas by competing particles such as gamma rays, fast electrons, and beta particles, and therefore minimizes false counts while retaining large signals from neutron interactions.

McGregor, Douglas S.↗

Commissioning of Dedicated Furnace for Nb3Sn Coatings of 2.6 GHz Single Cell Cavities

We present the results of commissioning a dedicated furnace for Nb3Sn coatings of 2.6 GHz single cell cavities. Nb3Sn is a desired coating due to its high critical temperature and smaller surface resistance compared to bulk Nb. Usage of Nb3Sn coated cavities will greatly reduce operating costs due to decreased dependance on cryo cooling. Tin is deposited by use of a tin chloride nucleation agent and tin vapor diffusion. Analysis of the resultant coating was performed using SEM/EDS to verify successful formation of Nb3Sn. Witness samples in line of sight of the source were used in order to understand the coating efficacy.

43 PARTICLE ACCELERATORS↗

PIP-II SSR2 Cavities Fabrication and Processing Experience

The Proton Improvement Plan-II (PIP-II [1]) linac will include 35 Single Spoke Resonators type 2 (SSR2). A preproduction SSR2 cryomodule will contain 5 jacketed cavities. Several units are already manufactured and prepared for cold testing. In this work, data collected from the fabrication, processing and preparation of the cavities will be presented and the improvements implemented after the completion of the first unit will be highlighted.

43 PARTICLE ACCELERATORS↗

Dark Sector and Gravitational Waves Searches with SRF Cavities at SQMS

The Superconducting Quantum Materials and Systems Center, led by Fermi National Accelerator Laboratory, is one of five research centers funded by the U.S. Department of Energy as part of a national initiative to develop and deploy the world’s most powerful quantum computers and sensors. The SQMS Center uses world-record quality-factor superconducting radio-frequency, or SRF, cavities as ultra-sensitive quantum probes. Within the quantum sensing thrust, researchers are developing experiments based on cavities and novel quantum devices to search for particles beyond the Standard Model, dark matter candidates, gravitational waves and fundamental material properties. The seminar will focus on Dark SRF and MAGO activities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microscopic Understanding of the Effects of Impurities in Low RRR SRF Cavities

The SRF community has shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurities of niobium coupons with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of impurity-based improvements can be better understood and improved upon. The combination of RF testing, temperature mapping, frequency vs temperature analysis, and materials studies reveals a microscopic picture of why low RRR cavities experience low BCS resistance behavior more prominently than their high RRR counterparts. We evaluate how differences in the mean free path, grain structure, and impurity profile affect RF performance. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

Howard, K.↗

Axion Dark Matter EXperiment 2A Cavity Characterization

We cooled the ADMX 2A cavities down to 5K and found the Q-factors for various tunings, which were about a factor of five larger than the Q-factors from the previous cooldown. We also found that the tuning mechanism with the piezo motor and gearbox is not currently equipped to handle cryogenic temperatures. We created an experimental warm bead pull setup using piezo motors, an alumina bead, a pulley system, and a distance calibrating script. We found that the bead pull method can successfully show us the reflection-induced electric field mode structure. This technique allowed us to differentiate between different TE and TM modes near mode crossings. However, some bead pull sweeps produced noisy or asymmetrical results, possibly due to asymmetries in the tuning rod orientation or antenna. Future iterations of the bead pull method can help us estimate the cavity form factor and maximize our scan range near mode crossings.

Maglione, D.↗

Fabrication status of production SSR1 jacketed cavities for PIP-II at Fermilab

This paper provides an overview of the current fabrication status of superconducting SSR1 spoke cavities intended for integration into the PIP-II SRF linac at Fermilab. It explores the ongoing development and fabrication processes of the jacketed SSR1 cavity, highlighting key modifications made in the mechanical design to enhance structural integrity.

Aiazzi, T.↗

Microscopic understanding of the effects of impurities in low RRR SRF cavities

The SRF community has shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurities of niobium coupons with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of impurity-based improvements can be better understood and improved upon. The combination of RF testing, temperature mapping, frequency vs temperature analysis, and materials studies reveals a microscopic picture of why low RRR cavities experience low BCS resistance behavior more prominently than their high RRR counterparts. We evaluate how differences in the mean free path, grain structure, and impurity profile affect RF performance. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

Howard, K.↗

Identifying the connections between grain growth and flux expulsion in low RRR niobium SRF cavities

The SRF community has shown that high temperature annealing can improve the flux expulsion of niobium cavities during cooldown. The required temperature will vary between cavities and different batches of material, typically around 800 C and up to 1000 C. However, for niobium with a low residual resistance ratio (RRR), even 1000 C is not enough to improve its poor flux expulsion. The purpose of this study is to observe the grain growth behavior of low RRR niobium coupons subjected to high temperature annealing to identify the mechanism for improving flux expulsion. We observe that low RRR material experiences less grain growth than high RRR when annealed at the same temperature. We search for the limitations to grain growth in low RRR material and develop a diagnostic based on grain structure to determine the appropriate recipe for good flux expulsion. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

Howard, K. [Chicago U.] (ORCID:0000000325613308)↗

Obvious and non-obvious aspects of digital Self-Excited-Loops for SRF cavity control

In 1978, Delayen showed how Self-Excited Loops (SEL) can be used to great advantage for controlling narrow-band SRF cavities. Its key capability is establishing closed-loop amplitude control early in the setup process, stabilizing Lorentz forces to allow cavity tuning and phase loop setup in a stable environment. As people around the world implement this basic idea with modern FPGA DSP technology, multiple variations and operational scenarios creep in that have both obvious and non-obvious ramifications for latency, feedback stability, and resiliency. This paper will review the key properties of a Delayen-style SEL when set up for open-loop, amplitude stabilized, and phase-stabilized modes. Then the original analog circuit will be compared and contrasted with the known variations of digital CORDIC-based implementations.

Doolittle, Larry [LBL, Berkeley]↗

Electromagnetic response of disordered superconducting cavities

We present the results for the resonant frequency shift and quality factor of disordered niobium (Nb) superconducting radio-frequency cavities driven out of equilibrium by the resonant microwave field. The theory is based on the non-equilibrium theory of superconductivity for the current response to the electromagnetic field at the vacuum–metal interface. We are able to accurately predict the observed frequency shifts with a precision of order fractions of kHz over the full temperature range 0 < T ≤ T c , including the negative frequency shift anomalies that are observed very near T c . The origin of these anomalies is shown to be the competition between the normal metal skin depth and the London penetration depth, which diverges as T→T c ⁻. An analytical approximation to the full current response, valid for |T-Tc| $\ll$ Tc, accounts for the negative frequency shift near T c . The non-monotonic dependence of the quality factor on the quasiparticle scattering rate is related to the pair-breaking effect of disorder on the superfluid fraction and, thus, the London penetration depth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Degenerate parametric down-conversion facilitated by exciton-plasmon polariton states in a nonlinear plasmonic cavity

Abstract We study the effect of degenerate parametric down-conversion (DPDC) in an ensemble of two-level quantum emitters (QEs) coupled via near-field interactions to a single surface plasmon (SP) mode of a nonlinear plasmonic cavity. For this purpose, we develop a quantum driven-dissipative model capturing non-equilibrium dynamics of the system in which incoherently pumped QEs have transition frequency tuned near the second-harmonic response of the SPs. Considering the strong coupling regime, i.e. the SP-QE interaction rate exceeds system dissipation rates, we find a critical SP-QE coupling attributed to the phase transition between normal and lasing steady states. Examining fluctuations above the system’s steady states, we predict new elementary excitations, namely, the exciton-plasmon polaritons formed by the two-SP quanta and single-exciton states of QEs. The contribution of two-SP quanta results in the linear scaling of the SP-QE interaction rate with the number of QEs,  o , as opposed to the  o -scaling known for the Dicke and Tavis–Cummings models. We further examine how SP-QE interaction scaling affects the polariton dispersions and power spectra in the vicinity of the critical coupling. For this purpose, we compare the calculation results assuming a finite ensemble of QEs and the model thermodynamic limit. The calculated power spectra predict an interplay of coherent photon emission by QEs near the second-harmonic frequency and correlated photon-pair emission at the fundamental frequency by the SPs (i.e. the photonic DPDC effect).

77 NANOSCIENCE AND NANOTECHNOLOGY↗