Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Thermal Process Monitoring for Wire-Arc Additive Manufacturing Using IR Cameras

Wire-arc additive manufacturing systems use robotic MIG welders to build parts using welding wire. As a part is built the temperature rises as energy is input and the thermal mass increases. While some pre-heat is ideal for welding, improper thermal management can lead to defects and negatively affect material properties. Thermal imaging allows for non-contact thermal monitoring and can be used to track thermal gradients as well as layer temperatures before and after deposition providing a method to ensure proper thermal management. A typical IR camera setup on an mBAAM system is discussed along with methods to use thermal monitoring to improve material properties and reduce defects in the final part.

Carter, William↗

“4H” X-ray camera

A 4H X-ray camera includes a high speed, high atomic number (Z), high spatial resolution sensor for sensing X-rays having energy over 30 keV and high speed readout electronics, and the high speed, high atomic number (Z), high spatial resolution sensor is coupled to the high speed readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensors of world’s largest digital camera snap first 3,200-megapixel images at SLAC

Vera C. Rubin Observatory will conduct the 10-year Legacy Survey of Space and Time (LSST), which will collect 60 petabytes of data to address some of the most pressing questions about the structure and evolution of the universe and the objects in it. LSST is designed to address four science areas: Understanding Dark Matter and Dark Energy Hazardous Asteroids and the Remote Solar System The Transient Optical Sky The Formation and Structure of the Milky Way Vera C. Rubin Observatory is a federal project jointly funded by the National Science Foundation and the Department of Energy Office of Science, with early construction funding received from private donations through the LSST Corporation. The NSF-funded LSST (now Rubin Observatory) Project Office for construction was established as an operating center under the management of the Association of Universities for Research in Astronomy (AURA). The DOE-funded effort to build the Rubin Observatory LSST Camera (LSSTCam) is managed by SLAC.

79 ASTRONOMY AND ASTROPHYSICS↗

Kraken Camera System

Specification sheet for Kraken camera system being developed by NNSS Transformational Diagnostics and Imaging in Los Alamos. Will be shared internally and externally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a Fast-Framing X-Ray Camera With Wide Dynamic Range for High-Energy Imaging

We present first characterization results, with a focus on high-flux measurements, of a fast-framing, wide-dynamic-range x-ray camera intended for high-energy imaging. The MM-PAD-2.1 uses an integrating pixel front-end with a charge removal architecture and in-pixel counter to extend the pixel well depth while maintaining low read noise across the full dynamic range. The charge-removal mechanism is dead-time-less (i.e., incoming signal continues to be integrated by the front-end while charge removal is taking place). The purpose of the highflux characterization was to determine the maximum sustained incident flux that could be measured while still exhibiting linear behavior. To this end, a 16 x 16 pixel prototype was tested at the Advanced Photon Source at Argonne National Laboratory using 10 keV photons generated by an undulator source. The intensity of the incident beam was varied over 3 orders of magnitude using a series of attenuators, and the signal integrated by the MM-PAD-2.1 prototype was compared to that measured by a He-filled ion chamber directly upstream. Initial results indicate linear performance up to ca. 10(10) ph/s in a spot spanning approximately 2 x 1.5 pixels (FWHM). The onset of transient radiation damage was observed during these measurements, characterized primarily by failure of digital readout from the detector ASIC. These effects were observed to reverse after annealing at 30 degrees C for several hours, with full recovery of the detector readout.

Shanks, Katherine S.↗

Passive millimeter wave radiometer system for calibration of infrared cameras

An apparatus for accurate measurement of surface and sub-surface temperatures of an object from a distance without contacting the object is provided. Illustrative embodiments provide for simultaneous measurement of thermal emission and emissivity in the mm-wave regime thereby enabling real-time non-contact measurement of emissivity. Corrected temperatures for the object which may be used for calibration of infrared thermographic cameras are determined from the measurement of emissivity.

Murphy, Ryan D.↗

Optical design concept of the CMB-S4 large-aperture telescopes and cameras

CMB-S4 -- the next-generation ground-based cosmic microwave background (CMB) experiment - will significantly advance the sensitivity of CMB measurements and improve our understanding of the origin and evolution of the universe. CMB-S4 will deploy large-aperture telescopes fielding hundreds of thousands of detectors at millimeter wavelengths. We present the baseline optical design concept of the large-aperture CMB-S4 telescopes, which consists of two optical configurations: (i) a new off-axis, three-mirror, free-form anastigmatic design and (ii) the existing coma-corrected crossed-Dragone design. We also present an overview of the optical configuration of the array of silicon optics cameras that will populate the focal plane with 85 diffraction-limited optics tubes covering up to 9 degrees of field of view, up to $1.1 \, \rm mm$ in wavelength. We describe the computational optimization methods that were put in place to implement the families of designs described here and give a brief update on the current status of the design effort.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of cameras and scanners on UAV and mobile platforms

Boresight and lever arm calibration of cameras and scanners on UAVs or mobile platforms is performed by optimizing the flight/travel path of the UAV/platform relative to control points or tie points. The flight/travel paths account for the potential bias of boresight angles, lever arm and times delays to produce an accurate estimation of the orientation of these cameras/scanners relative to the GNSS/INS coordinate system of the UAV/platform.

Habib, Ayman F.↗

A Joint Search for the Electromagnetic Counterpart to the Gravitational-Wave Binary Black-Hole Merger Candidate S250328ae with the Dark Energy Camera and the Prime Focus Spectrograph

The first detection of an optical counterpart to a gravitational wave signal revealed that collaborative efforts between instruments with different specializations provide a unique opportunity to acquire impactful multi-messenger data. We present results of such a joint search with the Dark Energy Camera (DECam) and Prime Focus Spectrograph (PFS) for the optical counterpart of the LIGO-Virgo-KAGRA event S250328ae, a binary black hole merger candidate of high significance detected at a distance of 511$\pm$82 Mpc and localized within an area of 3 (15) square degrees at 50% (90%) confidence. We observed the 90% confidence area with DECam and identified 36 high-confidence transient candidates after image processing, candidate selection, and candidate vetting. We observed with PFS to obtain optical spectra of DECam candidates, Swift-XRT candidates, and potential host galaxies of S250328ae. In total, 3897 targets were observed by seven pointings covering ~50% of the 90% confidence area. After template fitting and visual inspection, we identified 12 SNe, 159 QSOs, 2975 galaxies, and 131 stars. With the joint observations of DECam and PFS, we found variability in 12 SNe, 139 QSOs, 37 galaxies, and 2 stars. We do not identify any confident optical counterparts, though the association is not ruled out for three variable candidates that are not observed by PFS and 6 QSO candidates without clear variability if the optical counterpart of S250328ae is faint. Despite the lack of confident optical counterparts, this paper serves as a framework for future collaborations between wide-field imagers and multi-object spectrographs to maximize multi-messenger analyses.

Zhang, Haibin [Natl. Astron. Observ. of Japan] (OR↗

In-Band Scattering and Absorption of Infrared Blocking Foam Filters for Millimeter-wave Cameras

Expanded closed-cell polymer foams are widely used as thermal infrared (IR) blocking filters in millimeter-wave cameras, particularly for Cosmic Microwave Background observations. Precise knowledge of their millimeter-wave properties is essential for optimizing sensitivity. We present broadband (150 GHz - 2 THz) transmittance spectroscopy of Styroace-II and several Zotefoam filters, fitting their spectra with a radiative transfer model incorporating dielectric absorption and Rayleigh, Mie, and higher-order scattering. For a typical 5~cm thick filter stack at 280~GHz, Styroace-II exhibits ${\sim}10\%$ scattering with absorption estimated as ${\lesssim}5\%$ by effective-medium theory, while Zotefoam HD30 offers superior performance at ${\sim}3\%$ scattering and absorption likewise bounded to ${{\lesssim}0.3\%}$. Each model component is constrained at the ${\sim}0.1\%$ transmittance level for millimeter wavelengths. We observe batch-to-batch scattering variability of up to 2 percentage points in foams with multiple tested batches. Less commonly used Zotefoam formulations (LD15 and LD24) can further reduce in-band scattering to ${<}1\%$ while maintaining negligible in-band absorption and likely comparable IR blocking due to shared polyethylene absorption features and similar cell sizes. Based on this work, a filter constructed from the best measured LD24 batch has replaced the Styroace-II filter in a Simons Observatory 220/280 GHz Small Aperture Telescope.

Thomas, Alex [Chicago U., Astron. Astrophys. Ctr.;↗

FXR double-pulse gamma camera imaging plans

Presentation describes project to improve radiographic diagnostic capability in the Contained Firing Facility at Site 300 to take full advantage of ongoing improvements to the linac.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast myocardial perfusion imaging with {sup 99m}Tc in challenging patients using conventional SPECT cameras

Background: We attempted to validate the performance of a fast myocardial perfusion imaging (MPI) protocol in diagnostically challenging patients. Methods: 78 patients with ΒΜΙ > 24.9, LVH or three vessels disease underwent two sequential gated-MPI studies. The first at 15 (Early Imaging, EI) and the second at 45 (Late Imaging, LI) minutes post {sup 99m}Tc-injection, at both stress and rest. Counts over heart (H), liver (Liv) and subdiaphragmatic space (Sub) and image quality, and myocardial perfusion and function parameters were compared between the two protocols. Coronary angiography was performed within 2 months from MPI, and ROC analysis was used to compare the diagnostic accuracy for the detection of ≥50% diameter luminal stenosis. Results: Quality was optimal-good in 93% of EI and 98% of LI studies (P = .12), H/Liv and stress H/Sub ratios were similar, but rest H/Sub ratio was lower in EI (P = .009). SSS [10 (0 to 46) vs 9 (0 to 36), P = .006] and SDS [3 (0 to 35) vs 2 (0 to 34), P = .02] were higher in EI protocol. LVEF, motion and thickening scores did not differ between the two protocols. A highly significant (P < .001) linear relationship with clinically negligible mean differences in Bland-Altman analysis was observed for all perfusion and function-related data. Sensitivity (EI 81%, LI 80%) and specificity (65% for both) did not differ (P = .23) between the two protocols. Conclusion: The fast protocol is technically feasible and diagnostically accurate compared to the established protocol in diagnostically challenging patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of sequence tracking methods for Compton cameras based on CdZnTe arrays

In this study, the performance of sequence tracking methods for multiple interaction events in specific CdZnTe Compton imagers was evaluated using Monte Carlo simulations. The Compton imager consisted of a 6 × 6 array of virtual Frisch-grid CZT crystals, where the dimensions of each crystal were 5 × 5 × 12 mm 3 . The sequence tracking methods for another Compton imager that consists of two identical CZT crystals arrays were also evaluated. When 662 keV radiation was incident on the detectors, the percentages of the correct sequences determined by the simple comparison and deterministic methods for two sequential interactions were identical (~80 %), while those evaluated using the minimum squared difference method (55-59 %) and Three Compton method (45-55 %) for three sequential interactions, differed from each other. The reconstructed images of a 662 keV point source detected using single and double arrays were evaluated based on their angular resolution and signal-to-noise ratio, and the results showed that the double arrays outperformed single arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Medipix2/USB Portable Radiation Camera

Advances in the field of semiconductor technologies in the last years make possible to develop new types of ionizing radiation detectors. The Medipix2 readout ASIC is an example of such a device. It is the hybrid single photon counting imaging chip (sensor and readout chips are fabricated separately). With an appropriate sensor chip on the top, it can count single X-ray photons, without any noise or dark current, at high fluxes (several Gigaphotons per cm{sup 2} per second). It also offers excellent radiation hardness and good position resolution (256x256 pixels, each pixel has a 55x55 {mu}m{sup 2} area). To make the Medipix2 imaging chip more portable for specific applications a microprocessor controlled read-out system based on the USB (Universal Serial Bus) interface has been developed. It integrates all necessary detector support into one compact device (75x46 mm{sup 2}). All power supplies including sensor bias (up to 100 V) are internally derived from the voltage provided by the USB connection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accuracy of Measured Activity by the Dual Head Gamma Camera

The subject of research was investigation of the accuracy in determining the {sup 99m}Tc activity injected in a container simulating a single organ. Data acquisition as made with different width and range of energy windows described in the article. The activities of {sup 99m}Tc were determined with an error ranging from 7% to 27%. The most probable source of errors are scattered photons.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗