Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Redundancy management of multiple KT-70 inertial measurement units applicable to the space shuttle

Results of an investigation of velocity failure detection and isolation for 3 inertial measuring units (IMU) and 2 inertial measuring units (IMU) configurations are presented. The failure detection and isolation algorithm performance was highly successful and most types of velocity errors were detected and isolated. The failure detection and isolation algorithm also included attitude FDI but was not evaluated because of the lack of time and low resolution in the gimbal angle synchro outputs. The shuttle KT-70 IMUs will have dual-speed resolvers and high resolution gimbal angle readouts. It was demonstrated by these tests that a single computer utilizing a serial data bus can successfully control a redundant 3-IMU system and perform FDI.

Cook, L. J.↗

Solid state remote power controllers for 120 Vdc power systems

Solid state Remote Power Controllers (RPCs) developed for use in any dc power system with voltage up to 120 Vdc and distributed power up to 3.6 kW per bus are described. The RPCs were demonstrated to be reliable, 99 percent efficient, comparatively simple, and potentially low in cost. Advantages of the RPCs include: contactless switching; controlled rates of current rise and fall; current limiting; and fast, well-defined, repeatable response to overloads and faults.

Sundberg, G. R.↗

Shared memory for a fault-tolerant computer

A system is described for sharing a memory in a fault-tolerant computer. The memory is under the direct control and monitoring of error detecting and error diagnostic units in the fault-tolerant computer. This computer verifies that data to and from the memory is legally encoded and verifies that words read from the memory at a desired address are, in fact, actually delivered from that desired address. The means are provided for a second processor, which is independent of the direct control and monitoring of the error checking and diagnostic units of the fault-tolerant computer, and to share the memory of the fault-tolerant computer. Circuitry is included to verify that: (1) the processor has properly accessed a desired memory location in the memory; (2) a data word read-out from the memory is properly coded; and (3) no inactive memory was erroneously outputting data onto the shared memory bus.

Gilley, G. C.↗

Data management system CIU and DIU. Appendix A: CIU and DIU schematics

The Computer Interface Unit (CIU) and the Data Interface Unit (DIU) of the Data Management System (DMS) were described as to their functional location, purpose and function. This describes the CIU and DIU at the unit level illustrating their interface thru the Data Bus (DBUS) and to other DMS units. All unit level interfaces are defined as to function and characteristics. The controls, indicators, test points and connectors are listed and function, location and application are described for each. The mechanical configuration is defined and illustrated to provide card and component location for modification or repair purposes. Unique disassembly and assembly requirements are outlined where applicable. A unit internal functional block diagram level description is provided.

Source record↗

A summary of the ECAS performance and cost results for MHD systems

The potential is examined of various advanced power plant concepts using coal and coal-derived fuel. The results indicate that open cycle coal fired direct preheat MHD systems have potentially one of the highest coal-pile-to-bus-bar efficiencies and also one of the lowest costs of electricity (COE) of the systems studied. Closed cycle MHD systems may have the potential to approach the efficiency and COE of open cycle MHD. The 1200-1500 F liquid metal MHD systems studied do not appear to have the potential of exceeding the efficiency or competing with the COE of advanced steam plants.

Seikel, G. R.↗

Energy Conversion Alternatives Study (ECAS), Westinghouse phase 1. Volume 9: Closed-cycle MHD

A closed-cycle MHD system for an electric power plant was studied. It consists of 3 interlocking loops, an external heating loop, a closed-cycle cesium seeded argon nonequilibrium ionization MHD loop, and a steam bottomer. A MHD duct maximum temperature of 2366 K (3800 F), a pressure of 0.939 MPa (9.27 atm) and a Mach number of 0.9 are found to give a topping cycle efficiency of 59.3%; however when combined with an integrated gasifier and optimistic steam bottomer the coal to bus bar efficiency drops to 45.5%. A 1978 K (3100 F) cycle has an efficiency of 55.1% and a power plant efficiency of 42.2%. The high cost of the external heating loop components results in a cost of electricity of 21.41 mills/MJ (77.07 mills/kWh) for the high temperature system and 19.0 mills/MJ (68.5 mills/kWh) for the lower temperature system. It is, therefore, thought that this cycle may be more applicable to internally heated systems such as some futuristic high temperature gas cooled reactor.

Tsu, T. C.↗

MIA computer simulation test results report

Results of the first noise susceptibility computer simulation tests of the complete MIA receiver analytical model are presented. Computer simulation tests were conducted with both Gaussian and pulse noise inputs. The results of the Gaussian noise tests were compared to results predicted previously and were found to be in substantial agreement. The results of the pulse noise tests will be compared to the results of planned analogous tests in the Data Bus Evaluation Laboratory at a later time. The MIA computer model is considered to be fully operational at this time.

Unger, G. E.↗

Evaluation of electrostatic charge effects on the data processing system and the orbiter communication and tracking receivers

An analysis of radiated interference test results obtained from frictionally charged Orbiter TPS tile was presented. The tests included the measurement of noise pick-up by Orbiter S-band, L-band, C-band, and Ku-band antennas located beneath the tiles in a manner simulating their installation on Orbiter. In addition, the radiated field characteristics resulting from the static discharge was determined. The results are analyzed as to their effect on data bus equipment and on Orbiter Communications and Tracking (C&T) receivers. It was concluded that the radiated interference should have no effect on MDM's. However the CPU, IOP and PMU enclosures require some minor modification to assure immunity from P-static interference. Orbiter antenna tests indicate that the S-band receiver should not be affected by P-static noise. The TACAN and Radar Altimeter performance appears to be adequate but with a small margin. MSBLS performance is uncertain because laboratory instrumentation cannot approach the MSBLS sensitivity.

Lawton, R. M.↗

Simulating an aerospace multiprocessor

The paper describes a simulator which was used to evaluate the architecture of an aerospace multiprocessor. The simulator models interactions among the processors, memories, the central data bus, and a possible 'job stack'. Special features of the simulator are discussed, including the use of explicitly coded and individually distinguishable 'job models' instead of a statistically defined 'job mix' and a specialized Job Model Definition Language to automate the detailed coding of the models. Some results are presented which show that when the simulator was employed in conjunction with queuing theory and Markov-process analysis, more insight into system behavior was obtained than would have been with any one technique alone.

Mallach, E. G.↗

A summary of the ECAS performance and cost results for MHD system

The interagency-funded, NASA-coordinated Energy Conversion Alternatives Study (ECAS) has studied the potential of various advanced power plant concepts using coal and coal-derived fuel. Principle studies were conducted through prime contracts with the General Electric Company and the Westinghouse Electric Corporation. The results indicate that open-cycle coal-fired direct-preheat MHD systems have potentially one of the highest coal-pile-to-bus-bar efficiencies and also one of the lowest costs of electricity (COE) of the systems studied. Closed-cycle MHD systems may have the potential to approach the efficiency and COE of open-cycle MHD. The 1200-1500 F liquid-metal MHD systems studied do not appear to have the potential of exceeding the efficiency or competing with the COE of advanced steam plants.

Seikel, G. R.↗

A digital computer simulation and study of a direct-energy-transfer power-conditioning system

An investigation of the behavior of the power-conditioning system as a whole is a necessity to ensure the integrity of the aggregate system in the case of space applications. An approach for conducting such an investigation is considered. A description is given of the application of a general digital analog simulator program to the study of an aggregate power-conditioning system which is being developed for use on the International Ultraviolet Explorer spacecraft. The function of the direct energy transfer system studied involves a coupling of a solar array through a main distribution bus to the spacecraft electrical loads.

Burns, W. W., III↗

Penetrator mission concepts for exploration of the Galilean satellites

Penetrators are elongated missile-shaped objects designed to implant scientific instrumentation to depths of 1 to 15 meters in a wide variety of soil. A typical penetrator weighs 35 kg and impacts the surface at 150 m/sec oriented as close as possible to vertical. A spacecraft bus carries the penetrators to the target body, controls their deployment, and serves as a data communications relay. The analysis addresses the question of basic feasibility and covers such topics as trajectory requirements and delivered mass capability, deployment modes and penetrator retro sizing, impact site accessibility, guidance and control, and penetrator/bus communications. We conclude that such missions, while difficult in many respects, appear to be technically feasible in the context of Jovian system exploration in the post-1985 time period.

Friedlander, A. L.↗

The 512-channel correlator controller

A high-speed correlator for radio and radar observations was developed and a controller was designed so that the correlator could run automatically without computer intervention. The correlator controller assumes the role of bus master and keeps track of data and properly interrupts the computer at the end of the observation.

Brokl, S. S.↗

System Design for a Nuclear Electric Spacecraft Utilizing Out-of-core Thermionic Conversion

Basic guidelines are presented for a nuclear space power system which utilizes heat pipes to transport thermal power from a fast nuclear reactor to an out of core thermionic converter array. Design parameters are discussed for the nuclear reactor, heat pipes, thermionic converters, shields (neutron and gamma), waste heat rejection systems, and the electrical bus bar-cable system required to transport the high current/low voltage power to the processing equipment. Dimensions are compatible with shuttle payload bay constraints.

Estabrook, W. C.↗

A summary of the ECAS MHD power plant results

The performance and the cost of electricity (COE) for MHD systems utilizing coal or coal derived fuels are summarized along with a conceptual open cycle MHD plant design. The results show that open cycle coal fired recuperatively preheated MHD systems have potentially one of the highest coal-pile-to-bus bar efficiencies (48.3%) and also one of the lowest COE of the systems studied. Closed cycle, inert gas systems do not appear to have the potential of exceeding the efficiency of or competing with the COE of advanced steam plants.

Seikel, G. R.↗

Payload specialist station study: Volume 2, part 3: Program analysis and planning for phase C/D

The controls and displays (C&D) required at the Orbiter aft-flight deck (AFD) and the core C&D required at the Payload Specialist Station (PSS) are identified in this document. The AFD C&D Concept consists of a multifunction display system (MFDS) and elements of multiuse mission support equipment (MMSE). The MFDS consists of two CRTs, a display electronics unit (DEU), and a keyboard. The MMSE consists of a manual pointing controller (MPC), five digit numeric displays, 10 character alphanumeric legends, event timers, analog meters, rotary and toggle switches. The MMSE may be hardwired to the experiment, or interface with a data bus at the PSS for signal processing. The MFDS has video capability, with alphanumeric and graphic overlay features, on one CRT and alphanumeric and graphic (tricolor) capability on a second CRT. The DEU will have the capability to communicate, via redundant data buses, with both the spacelab experiment and subsystem computers.

Source record↗

Interface standards for computer equipment

The ability to configure data systems using modules provided by independent manufacturers is complicated by the wide range of electrical, mechanical, and functional characteristics exhibited within the equipment provided by different manufacturers of computers, peripherals, and terminal devices. A number of international organizations were and still are involved in the creation of standards that enable devices to be interconnected with minimal difficulty, usually involving only a cable or data bus connection that is defined by the standard. The elements covered by an interface standard are covered and the most prominent interface standards presently in use are identified and described.

Source record↗

Computer-aided analysis of CCD linear image sensors

Special test equipment and techniques to collect and process image information from charge coupled devices (CCDs) by digital computer were reviewed. The video channel was traced from the CCD to the direct memory access bus of the Interdata Computer. Software was developed to evaluate and characterize a CCD for (1) dark signal versus temperature relationship, (2) calculation of temporal noise magnitude and noise shape for each pixel, (3) spatial noise into the video chain due to dark signal, (4) response versus illumination relationship (gamma), (5) response versus wavelength of illumination (spectral), (6) optimization of forcing functions, and (7) evaluation of an image viewed by a CCD. The basic software differences and specific examples of each program operating on real data are presented.

Prince, S. S.↗