Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Performance optimization, modeling and analysis of sparse matrix-matrix products on multi-core and many-core processors

Sparse matrix-matrix multiplication (SpGEMM) is a computational primitive that is widely used in areas ranging from traditional numerical applications to recent big data analysis and machine learning. Although many SpGEMM algorithms have been proposed, hardware specific optimizations for multi- and many-core processors are lacking and a detailed analysis of their performance under various use cases and matrices is not available. In this work, we firstly identify and mitigate multiple bottlenecks with memory management and thread scheduling on Intel Xeon Phi (Knights Landing or KNL). Specifically targeting many-core processors, we develop a hash-table-based algorithm and optimize a heap-based shared-memory SpGEMM algorithm. We examine their performance together with other publicly available codes. Different from the literature, our evaluation also includes use cases that are representative of real graph algorithms, such as multi-source breadth-first search or triangle counting. Our hash-table and heap-based algorithms are showing significant speedups from libraries in the majority of the cases while different algorithms dominate the other scenarios with different matrix size, sparsity, compression factor and operation type. We wrap up in-depth evaluation results and make a recipe to give the best SpGEMM algorithm for target scenario. We build the performance model for hash-table and heap-based algorithms, which supports the recipe. A critical finding is that hash-table-based SpGEMM gets a significant performance boost if the nonzeros are not required to be sorted within each row of the output matrix. Finally, we integrate our implementations into a large-scale protein clustering code named HipMCL, accelerating its SpGEMM kernel by up to 10X and achieving an overall performance boost for the whole HipMCL application by 2.6X.

97 MATHEMATICS AND COMPUTING↗

Conceptual magnet design study for fusion nuclear science facility [Magnet design study for fusion nuclear science facility]

The Fusion Nuclear Science Facility (FNSF) is a nuclear confinement device to provide the integrated fusion environment with fusion reactor components. The FNSF is the stepping stone to bridge the technical gaps of burning plasma and nuclear science between the International Thermal Nuclear Experimental Reactor (ITER), currently under construction in the south of France, and the demonstration power plant (DEMO). For the next-step fusion reactors, resistive copper magnet cannot be a sustainable solution due to large power consumption in coils of large size needed. Both Low temperature superconductor (LTS) and high temperature superconductor (HTS) are considered for the FNSF magnet design based on the state-of-the-art fusion superconducting magnet technology. Input parameters to FNSF magnet design include magnetic field of 7.5 T at plasma center with a major radius of 4.8 m and minor radius of 1.2 m, and a peak field of over 16 T on the TF coils. The high magnetic field can be achieved by using the high performance ternary Restack Rod Process (RRP) Nb3Sn strands for toroidal field (TF) magnets and a high aspect ratio rectangular cable-in-conduit conductor (CICC) design. The conductor design concept and TF coil winding pack composition and dimension are discussed based on the horizontal maintenance scheme. Neutron radiation limits for the LTS and HTS conductors and electrical insulation materials are reviewed based on the available materials previously tested. The material radiation limits for FNSF magnets are defined as part of the conceptual design studies. In conclusion, the global structural analysis of FNSF magnets based on the radial build was performed to validate feasibility for the plant layout toward horizontal maintenance and global structural integrity of its magnet system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Turbulent Flow Simulation at the Exascale: Opportunities and Challenges Workshop: August 4-5, 2015, Washington, D.C.

This report details the impact exascale will bring to turbulent-flow simulations in applied science and technology. The need for accurate simulation of turbulent flows is evident across the DOE applied-science and engineering portfolios, including combustion, plasma physics, nuclear-reactor physics, wind energy, and atmospheric science. The workshop brought together experts in turbulent-flow simulation, computational mathematics, and high-performance computing. Building upon previous ASCR workshops on exascale computing, participants defined a research agenda and path forward that will enable scientists and engineers to continually leverage, engage, and direct advances in computational systems on the path to exascale computing.

97 MATHEMATICS AND COMPUTING↗

Design and Field Testing of Manufacturable Advanced Low-Cost Receiver for Parabolic Trough Solar Power

This project addresses the 30-yr service life, ease of manufacturability for low cost, and low Operations and Maintenance (O&M) costs for our novel parabolic trough receiver, SunTrap. Current trough-based commercial power plants operate at 400°C or below, in part due to poor performance and lifetime of existing receivers at higher temperatures. Thermal losses from such receivers are dominated by radiation; by the Stefan- Boltzmann law, radiative losses have a component that scales as T 4, challenging high-temperature efficiency. Our novel SunTrap receiver offers increased reliability by eliminating the need to operate in a vacuum, while improving performance at higher temperatures by using high-performance insulation on exposed sections of the receiver that absorb negligible solar flux. As a result, SunTrap offers comparable optical efficiency to currently available technology while reducing thermal losses at higher temperatures. In this project, our novel receiver and all subcomponents have been designed to be compatible with molten salts to enable operation at next generation trough-based exit temperatures between 500 and 550°C. Norwich Technologies, with collaborators from Creare, Thermodyne, Solar Dynamics (previously Abengoa Solar), and the University of Louisiana – Lafayette successfully iterated the design of the SunTrap receiver through a series of modelling efforts, cost analyses, prototype builds, and performance and lifetime tests to minimize the levelized cost of energy (LCOE). The final design (1) realized predicted receiver performance in a series of field optical efficiency, laboratory thermal efficiency and freeze/thaw recovery tests, (2) optimized the receiver with respect to integration with standard collector systems, receiver-to-receiver connections, and receiver-to-mirror connections, (3) demonstrated 30-yr service life of receiver and all components of the receiver, (4) developed commercialization and manufacturing plans to enable rapid deployment, and (5) demonstrated durability of an air-stable solar-selective coating. NT’s disruptive technology marshals diverse advances in design, materials and coatings to revolutionize key aspects of the CSP trough solar field. By enabling significant operational and cost advances, this technology offers potential decreases in LCOE of over 20% compared to traditional parabolic trough systems.

14 SOLAR ENERGY↗

Recovery Act: Training Program Development for Commercial Building Equipment Technicians (Final Scientific/Technical Report)

The overall goal of this project has been to develop curricula, certification requirements, and accreditation standards for training on energy efficient practices and technologies for commercial building technicians. These training products will advance industry expertise towards net-zero energy commercial building goals and will result in a substantial reduction in energy use. The ultimate objective is to develop a workforce that can bring existing commercial buildings up to their energy performance potential and ensure that new commercial buildings do not fall below their expected optimal level of performance. Commercial building equipment technicians participating in this training program will learn how to best operate commercial buildings to ensure they reach their expected energy performance level. The training is a combination of classroom, online and on-site lessons. The Texas Engineering Extension Service (TEEX) developed curricula using subject matter and adult learning experts to ensure the training meets certification requirements and accreditation standards for training these technicians. The training targets a specific climate zone to meets the needs, specialized expertise, and perspectives of the commercial building equipment technicians in that zone. The combination of efficient operations and advanced design will improve the internal built environment of a commercial building by increasing comfort and safety, while reducing energy use and environmental impact. Properly trained technicians will ensure equipment operates at design specifications. A second impact is a more highly trained workforce that is better equipped to obtain employment. Organizations that contributed to the development of the training program include TEEX and the Texas Engineering Experiment Station (TEES) (both members of The Texas A&M University System). TEES is also a member of the Building Commissioning Association. This report includes a description of the project accomplishments, including the course development phases, tasks associated with each phase, and detailed list of the course materials developed. A summary of each year's activities is also included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Stud Walls with Continuous Exterior Insulation for Factory Built Housing

The Advanced Envelope Research effort will provide factory homebuilders with high performance, cost-effective alternative envelope designs. In the near term, these technologies will play a central role in meeting stringent energy code requirements. For manufactured homes, the thermal requirements, last updated by statute in 1994, will move up to the more rigorous IECC 2012 levels in 2013, the requirements of which are consistent with site built and modular housing. This places added urgency on identifying envelope technologies that the industry can implement in the short timeframe. The primary goal of this research is to develop wall designs that meet the thermal requirements based on 2012 IECC standards. Given the affordable nature of manufactured homes, impact on first cost is a major consideration in developing the new envelope technologies. This work is part of a four-phase, multi-year effort. Phase 1 identified seven envelope technologies and provided a preliminary assessment of three selected methods for building high performance wall systems. Phase 2 focused on the development of viable product designs, manufacturing strategies, addressing code and structural issues, and cost analysis of the three selected options. An industry advisory committee helped critique and select the most viable solution to move further in the research — stud walls with continuous exterior insulation. Phase 3, the subject of the current report, focused on the design development of the selected wall concept and explored variations on the use of exterior foam insulation. The scope also included material selection, manufacturing and cost analysis, and prototyping and testing.

Advanced envelope research↗

Stud Walls With Continuous Exterior Insulation for Factory Built Housing: New York, New York (Fact Sheet), NREL (National Renewable Energy Laboratory)

The Advanced Envelope Research effort will provide factory homebuilders with high performance, cost-effective alternative envelope designs. In the near term, these technologies will play a central role in meeting stringent energy code requirements. For manufactured homes, the thermal requirements, last updated by statute in 1994, will move up to the more rigorous IECC 2012 levels in 2013, the requirements of which are consistent with site built and modular housing. This places added urgency on identifying envelope technologies that the industry can implement in the short timeframe. The primary goal of this research is to develop wall designs that meet the thermal requirements based on 2012 IECC standards. Given the affordable nature of manufactured homes, impact on first cost is a major consideration in developing the new envelope technologies. This work is part of a four-phase, multi-year effort. Phase 1 identified seven envelope technologies and provided a preliminary assessment of three selected methods for building high performance wall systems. Phase 2 focused on the development of viable product designs, manufacturing strategies, addressing code and structural issues, and cost analysis of the three selected options. An industry advisory committee helped critique and select the most viable solution to move further in the research - stud walls with continuous exterior insulation. Phase 3, the subject of the current report, focused on the design development of the selected wall concept and explored variations on the use of exterior foam insulation. The scope also included material selection, manufacturing and cost analysis, and prototyping and testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Envelope Research for Factory Built Housing, Phase 3 -- Design Development and Prototyping

The Advanced Envelope Research effort will provide factory homebuilders with high performance, cost-effective alternative envelope designs. In the near term, these technologies will play a central role in meeting stringent energy code requirements. For manufactured homes, the thermal requirements, last updated by statute in 1994, will move up to the more rigorous IECC 2012 levels in 2013, the requirements of which are consistent with site built and modular housing. This places added urgency on identifying envelope technologies that the industry can implement in the short timeframe. The primary goal of this research is to develop wall designs that meet the thermal requirements based on 2012 IECC standards. Given the affordable nature of manufactured homes, impact on first cost is a major consideration in developing the new envelope technologies. This work is part of a four-phase, multi-year effort. Phase 1 identified seven envelope technologies and provided a preliminary assessment of three selected methods for building high performance wall systems. Phase 2 focused on the development of viable product designs, manufacturing strategies, addressing code and structural issues, and cost analysis of the three selected options. An industry advisory committee helped critique and select the most viable solution to move further in the research -- stud walls with continuous exterior insulation. Phase 3, the subject of the current report, focused on the design development of the selected wall concept and explored variations on the use of exterior foam insulation. The scope also included material selection, manufacturing and cost analysis, and prototyping and testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Envelope Research for Factory Built Housing, Phase 3. Design Development and Prototyping

The Advanced Envelope Research effort will provide factory homebuilders with high performance, cost-effective alternative envelope designs. In the near term, these technologies will play a central role in meeting stringent energy code requirements. For manufactured homes, the thermal requirements, last updated by statute in 1994, will move up to the more rigorous IECC 2012 levels in 2013, the requirements of which are consistent with site built and modular housing. This places added urgency on identifying envelope technologies that the industry can implement in the short timeframe. The primary goal of this research is to develop wall designs that meet the thermal requirements based on 2012 IECC standards. Given the affordable nature of manufactured homes, impact on first cost is a major consideration in developing the new envelope technologies. This work is part of a four-phase, multi-year effort. Phase 1 identified seven envelope technologies and provided a preliminary assessment of three selected methods for building high performance wall systems. Phase 2 focused on the development of viable product designs, manufacturing strategies, addressing code and structural issues, and cost analysis of the three selected options. An industry advisory committee helped critique and select the most viable solution to move further in the research -- stud walls with continuous exterior insulation. Phase 3, the subject of the current report, focused on the design development of the selected wall concept and explored variations on the use of exterior foam insulation. The scope also included material selection, manufacturing and cost analysis, and prototyping and testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analyzing the Impact of Future Weather Data on Energy Consumption in Weatherization Assistant

This study supports the mission of the U.S. Department of Energy’s Weatherization Assistance Program (WAP), which aims to increase the energy efficiency of dwellings and reduce their total residential expenditures. Specifically, we examine how projected future climate conditions may affect residential building energy performance by integrating future weather data into the National Energy Audit Tool (NEAT). Since WAP evaluates the cost-effectiveness of retrofit measures over lifespans of up to 30 years, accounting for evolving climate conditions is increasingly important. To reflect future household energy demands, this study replaces historically based Typical Meteorological Year (TMY3) weather inputs with Future Typical Meteorological Year (fTMY) datasets derived from global climate model (GCM) projections. A simulation-based framework was established to enable NEAT analysis under future weather conditions. This workflow involves converting EPW-format weather files into JSON inputs compatible with NEAT and generating degree-hour metrics needed for load calculations. The fTMY dataset used in this study was developed by Oak Ridge National Laboratory through downscaling of six GCMs under different emission scenarios and covers the period from 2020 to 2100. In contrast, the TMY3 dataset is based on historical weather data from 1961 to 1990. Simulations were conducted for benchmark single-family prototype buildings across ASHRAE climate zones 1–7, which cover all regions of the U.S. except the subarctic Zone 8 in northern Alaska, evaluating both heating and cooling loads under TMY3 and fTMY conditions. Four foundation types were tested, while heating systems were standardized, as NEAT does not differentiate thermal energy load by HVAC system type in its load calculations. Results show that fTMY weather input consistently yield lower heating loads and higher cooling loads across most locations, aligning with expected climate warming trends. Notably, colder regions such as zones 6A, 6B, and 7 experience marked reductions in heating load, while warmer and transitional zones, such as 2A (Lufkin, TX) and 3C (San Francisco, CA), have substantial increases in cooling loads. Although this study does not directly assess the performance of retrofit measures under future climate conditions, it provides a critical foundation for doing so. By quantifying shifts in baseline (i.e., pre-retrofit case) energy loads between historical and future weather files, the study highlights the importance of integrating climate-responsive data into audit tools. These findings will inform future efforts to evaluate the long-term effectiveness and cost-effectiveness of weatherization measures under changing climate conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Semi-Annual Report for Modular Integrated Gas High Temperature Reactor Development during Performance Period April 2022 - September 2022

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multidisciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary coolant system to ensure temperatures within the core remain below safety margins during steady-state and potential accident scenarios. This second semi-annual report summarized the progress made at Argonne on the two tasks during the second half of FY22. As a part of the RCCS design task, a scoping calculation in estimating HVAC capability for the HC-HTGR reactor building was performed. A water panel modeling study was first performed with the test case, which confirms the capability of the RELAP5-3D modeling approach to explore various design options of the HC-HTGR RCCS under consideration. Then, a reference RELAP5-3D model for the unit geometry of the preliminary design of the HC-HTGR RCCS was developed. A preliminary performance analysis was conducted to evaluate the performances of a single-phase natural circulation and panel conduction in various operating conditions. For the primary coolant system analysis task, preliminary thermal hydraulic analysis of the HC-HTGR core design was performed with a high resolution 1D fluid-3D solid coupled model using the System Analysis Module (SAM) to assess the assembly coolant channel and bypass flow mass flow rate distribution. Some preliminary work on the development of a full core reduced order model was discussed following the assembly level model to predict the core wide coolant flow distribution and to model certain operational and accidental transients.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hermetically sealed porous-wall hollow microspheres enabled by monolithic glass coatings: Potential for thermal insulation applications

Thermal insulation materials are crucial to improve the energy performance of buildings and industrial applications. We report an approach to create hermetically vacuum-sealed silica-based hollow microspheres that can lower the thermal conductivity of closed-cell insulation materials. The wall structure of these hollow microspheres includes a reticulated network of pores or channels that extend through the thickness of the wall. When a thin layer of glass material is applied to the wall exterior, followed by a vacuum-assisted thermal treatment process, the coated microsphere surfaces display a highly dense conformal coverage and near-complete elimination of surface porosity. The sealing efficiency of these microspheres is verified by trapping argon within their cavities as well as through evacuating their hollow cores. Notably, incorporating the evacuated microspheres into a polymer matrix resulted in ~27% enhancement in its thermal insulation performance and no notable loss of performance was observed following three months of exposure to ambient conditions. Thus, we believe that the present study offers a commercially viable strategy that opens the door to applications of such inorganic hollow particles in areas ranging from vacuum-based thermal insulation systems to catalysis, separation technologies, and medical fields.

36 MATERIALS SCIENCE↗

Preserving the Mound Laboratory Legacy-The Mound Cold War Discovery Center - 19550

The Mound Cold War Discovery Center (MCWDC) opened at the former DOE Mound Laboratory in Miamisburg, Ohio, on April 23, 2018, approximately three years after the US Department of Energy (DOE) Office of Legacy Management, Dayton History, the Mound Science and EnergyMuseum Association (MSEMA), and the Mound Development Corporation signed the Mound Educational Center Memorandum of Agreement (MOA). This MOA designated each party's responsibilities for the facility and laid the groundwork for DOE to enter into a Cooperative Agreement with Dayton History to design, build, and perform initial operations of the educational center. Dayton History is a nonprofit organization that operates several historical facilities in Montgomery County, Ohio. The Mound Development Corporation is the nonprofit organization that operates the Mound Business Park, privately owned property previously associated with the former DOE Mound Laboratory. The US Atomic Energy Commission began operations at the Mound Laboratory in 1948 as an integrated research, development, and production facility that supported the nation's weapons and energy programs. In October 2015, DOE entered into a five-year Cooperative Agreement with Dayton History to preserve, protect, and make accessible legacy records and information about the history of the Mound site through the development of an educational center. Years One and Two were for design and construction, respectively. Years Three through Five were for operation of the new center. The new center, located in a building owned by the Mound Development Corporation, would carry on the mission started by the MSEMA, a nonprofit organization started by former Mound site employees more than 15 years ago after DOE mission work ended at the site. As part of the cooperative agreement, Dayton History is responsible for creating interactive displays and exhibits to draw, entertain, and educate the public on the Mound site's significant contributions to the protection of the nation; developing educational programs; and initiating marketing strategies for the long-term sustainability of the educational center. In 2016, parties to the MOA officially named the facility the Mound Cold War Discovery Center. The MCWDC was designed to preserve the history of the Mound site through effective, entertaining, and efficient communication of the history of the Mound Laboratory; the site's legacy to the US weapons production complex and space exploration program; and promote understanding of what has happened at the site since DOE mission work ended, including environmental cleanup under the Comprehensive Environmental Response, Compensation, and Liability Act and the regulator-approved end state of industrial/commercial land use with associated institutional controls. The cooperative agreement requires Dayton History to develop and implement marketing strategies to support the long-term sustainability of the MCWDC at the Mound site. Dayton History will submit a report after the first year of operation and every year thereafter during the period of the cooperative agreement. These reports will describe and status efforts to obtain sustainability and offer for consideration any operational changes, corrections, or suggestions that may improve the potential for sustainability. Prior to the end of the cooperative agreement, a sustainability assessment decision will be made by DOE to determine whether the MCWDC has enough community interest to financially sustain itself at the Mound site. The status of the MCWDC Legacy Fund established by Dayton History will be considered in DoE's assessment determination. If DOE determines that the MCWDC is not sustainable at the Mound site, the exhibits will be relocated to Carillon Historical Park in Dayton, with the five key exhibits that were predetermined in the MOA to be placed on permanent display, thereby maintaining the legacy of the Mound site. Dayton History is required to submit a final closeout report at the end of Year Five of the cooperative agreement. The report will describe all activities completed under the agreement, provide an assessment of how project goals were achieved or not achieved, and describe how the legacy of the site will be preserved. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quality Assurance Strategy for Existing Homes: Final Quality Management Primer for High Performing Homes

This guide is designed to help Building America (BA) teams understand quality management and its role in transitioning from conventional to high performance home building and remodeling. It explains what quality means, the value of quality management systems, the unique need for QMS when building high performing homes, and the first steps to a implementing a comprehensive QMS. This document provides a framework and context for BA teams when they encounter builders and remodelers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validating Simulated Models of Energy Consumption by a Battery Electric Motorcoach: A real-world deployment in a harsh climate.

Many efforts have been made to simulate energy consumption of battery electric buses (BEBs) to optimize their deployment into existing fleets. The models produced, however, are rarely validated against real-world consumption data, limiting their generalizability and widespread application to fleets around the US. Furthermore, a major concern specific to BEBs is the effects of harsh climates on their performance. We build upon the state-of-the-art energy consumption modeling techniques developed for BEBs and apply them to a unique geographic context and a unique electrified vehicle. This geography, climate, and vehicle further the existing understanding of the factors affecting medium- and heavy-duty electric vehicles (MHDEVs) by allowing for new relationships to be tested and by assessing the generalizability of known relationships to new contexts. We find that temperature is less predictive of energy consumption for the battery electric motorcoach (BEM) in the case study environment than it is for BEBs in other studies. A mitigating factor that we presume to be working on the relationship between temperature and energy consumption is the fact that the BEM route does not stop between origin and destination to exchange passengers, and in turn, conditioned cabin air. Our model also incorporates wind speed and direction relative to travel, which is a novel contribution of our methodology. Results from our study are helpful for transit service planners, fleet operators, and logistics firms for improving their ability to predict performance of potential deployments of MHDEVs into existing operations.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Indoor air quality in 24 California residences designed as high-performance homes

Today’s high performance green homes are reaching previously unheard of levels of airtightness and are using new materials, technologies and strategies, whose impacts on Indoor Air Quality (IAQ) cannot be fully anticipated from prior studies. This research study used pollutant measurements, home inspections, diagnostic testing and occupant surveys to assess IAQ in 24 new or deeply retrofitted homes designed to be high performance green buildings in California. Although the mechanically vented homes were six times as airtight as non-mechanically ventilated homes (medians of 1.1 and 6.1 ACH 50 , n=11 and n=8, respectively), their use of mechanical ventilation systems and possibly window operation meant their median air exchange rates were almost the same (0.30 versus 0.32 hr -1 , n=8 and n=8, respectively). Pollutant levels were also similar in vented and unvented homes. In addition, these similarities were achieved despite numerous observed faults in complex mechanical ventilation systems. More rigorous commissioning is still recommended. Cooking exhaust systems were used inconsistently and several suffered from design flaws. Failure to follow best practices led to IAQ problems in some cases. Ambient nitrogen dioxide standards were exceeded or nearly so in four homes that either used gas ranges with standing pilots, or in Passive House-style homes that used gas cooking burners without venting range hoods. Homes without active particle filtration had particle count concentrations approximately double those in homes with enhanced filtration. The majority of homes reported using low-emitting materials; consistent with this, formaldehyde levels were approximately half those in conventional, new CA homes built before 2008. Emissions of ultrafine particles (with diameters <100 nm) were dramatically lower on induction electric cooktops, compared with either gas or resistance electric models. These results indicate that high performance homes can achieve acceptable and even exceptional IAQ by providing adequate general mechanical ventilation, using low-emitting materials, providing mechanical particle filtration, incorporating well-designed exhaust ventilation for kitchens and bathrooms, and educating occupants to use the kitchen and bath ventilation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How Building America Research is Removing Major Roadblocks to High-Performance Homes: Preprint

Today the U.S. housing industry is critically challenged to deliver homes that safely and effectively meet demanding new performance requirements of homeowners and modern building codes. But the housing industry must learn to better manage real and perceived risks that can impact occupant health, comfort, and building durability. It is clear from decades of applied research through the U.S. Department of Energy's (DOE) Building America program that many building energy efficiency and performance improvements will not be adopted by the market or industry standards if the costs and perceived risks of change outweigh the known benefits, especially when the benefits do not accrue directly to businesses who must take those risks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗