Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Online Calculator to Evaluate the Impact of Airtightness on Residential Building Energy Consumption and Moisture Transfer

Energy consumption in residential buildings is primarily driven by space conditioning applications. Space heating and cooling, on average, consume approximately 50% of the energy in the residential buildings in the U.S. The primary energy use due to infiltration is more than 2.8 Quads, which is 29% of primary energy consumption attributable to fenestration and building envelope components in residential buildings in US in 2010. There are advanced air barrier technologies and construction practices to reduce air leakage in buildings, which are currently available in the market. However, the lack of adequate information on their impact on energy consumption and the durability of buildings has caused the slow adoption of these technologies and methods. In the past, the authors developed an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in airtightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations, given that air leakage through the building envelope can have a significant impact on moisture transfer. The calculator is again being expanded by adding residential and additional commercial building data. In this paper, we present the impact of airtightness in residential buildings on energy consumption and moisture transfer. The study includes the analysis of airtightness in 52 major cities in the U.S. and five cities in Canada on a residential building that includes a crawlspace and has a gas furnace.

Kunwar, Niraj↗

Treatment of Chlorinated Solvents in Groundwater Beneath an Occupied Building at The Young - Rainey STAR Center (Science, Technology, and Research Center) - 16342

Groundwater contamination, consisting of two dissolved-phase plumes originating from chlorinated solvent source areas, in the southeastern portion of the Young- Rainey Star Center (also known as the Pinellas County, Florida, Site) in Largo, Florida, has migrated beyond the property boundary, beneath the roadways, and beneath adjacent properties to the south and east. Groundwater contamination will persist as long as the onsite contaminant source remains. The origin of the contamination appears to be multiple long-term point sources beneath Building 100, a 4.5 ha (11 acre) building that housed manufacturing facilities during US DOE operations at the site. The site is now owned by Pinellas County, and most of the space inside the building is leased to private companies, so DOE chose not to conduct characterization or remediation through the floor of the building, instead choosing to conduct all work from outside the building. Injection of emulsified soybean oil and a microbial culture has been used at other areas of the site to accelerate naturally occurring bacterial processes that degrade groundwater contaminants to harmless compounds, and that same approach was chosen for this task. The technical approach consisted of installing horizontal wells from outside the building footprint, extending through and around the identified subsurface treatment areas, and terminating beneath the building. Two 107 m (350 ft) long wells, two 122 m (400 ft) long wells, and four 137 m (450 ft) long wells have been installed to intersect the inferred source areas and confirmed contaminant plumes beneath the building. DOE then injected emulsified vegetable oil and a microbial culture into the horizontal wells at each of several target areas beneath the building where the highest groundwater contaminant concentrations have been detected. The target areas are the northwest corner of the building between the old drum storage pad locations and monitoring well PIN12-S35B, the vicinity of former monitoring well PIN12-S57B, and hydraulically up-gradient from the south plume and the east plume at the points where they exit from beneath the building. We describe the details of designing and constructing horizontal injection wells for bioremediation beneath a large, occupied industrial production facility, including lessons learned; technical, logistical, and environmental challenges; community relations; and regulatory relations. Because of the expected lag in biological acclimation and response, distance between the treatment areas and associated monitoring points, and low groundwater velocity, it will likely be years before the full impact of the project will be realized. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation-based characterization of the variability of earthquake risk to buildings in the near-field

Recent advancements in high performance computing platforms and computational workflow for regional-scale simulations are enabling unprecedented modeling of fault-to-structure earthquake processes. Regional simulations resolving ground motions at frequencies relevant to engineered systems are becoming computationally viable and provide a new capability to improve understanding of the geographical distribution and intensity of risk to buildings and critical infrastructure. As computational capabilities advance, it is essential to move beyond illustrative single rupture realizations for scenario earthquake events towards the development of a full suite of rupture realizations that appropriately characterize the range of risk to building systems. The work described in this article investigates the application of a suite of fault rupture realizations with the objective of assessing near-fault, site-specific seismic demand variability for building structures. A representative high-performance regional-scale computational model is utilized to execute ground motion and building response simulations based on 18 kinematic rupture realizations of an M7 strike-slip scenario earthquake. The fault rupture models for the scenario earthquake are created by systematically perturbing the hypocenter location and stochastically generating rupture parameters (slip, rise time, rake angle) to represent a breadth of ground motion intensities resulting from the spatial and temporal variabilities of an earthquake rupture process. The resulting seismic demand variability for three-story (short period) and forty-story (long period) steel moment-resisting frame buildings is characterized in terms of the median and distribution of peak inter-story drift ratio for a range of near-fault sites. The full suite of 18 fault rupture realizations and approximately 280,000 nonlinear dynamic building simulations indicate that the three-story building undergoes higher median seismic demand and significantly greater variability of demand at a given site than the forty-story building, which has important implications for the level of certainty in predicting building performance during an earthquake. The simulations performed provide deeper insight into the relationship between fault rupture parameterization and building response, which is essential information for developing a representative suite of rupture realizations for specific earthquake scenarios.

58 GEOSCIENCES↗

Data-driven key performance indicators and datasets for building energy flexibility: A review and perspectives

Energy flexibility, through short-term demand-side management (DSM) and energy storage technologies, is now seen as a major key to balancing the fluctuating supply in different energy grids with the energy demand of buildings. This is especially important when considering the intermittent nature of ever-growing renewable energy production, as well as the increasing dynamics of electricity demand in buildings. This paper provides a holistic review of (1) data-driven energy flexibility key performance indicators (KPIs) for buildings in the operational phase and (2) open datasets that can be used for testing energy flexibility KPIs. The review identifies a total of 48 data-driven energy flexibility KPIs from 87 recent and relevant publications. These KPIs were categorized and analyzed according to their type, complexity, scope, key stakeholders, data requirement, baseline requirement, resolution, and popularity. Moreover, 330 building datasets were collected and evaluated. Of those, 16 were deemed adequate to feature building performing demand response or building-to-grid (B2G) services. The DSM strategy, building scope, grid type, control strategy, needed data features, and usability of these selected 16 datasets were analyzed. This review reveals future opportunities to address limitations in the existing literature: (1) developing new data-driven methodologies to specifically evaluate different energy flexibility strategies and B2G services of existing buildings; (2) developing baseline-free KPIs that could be calculated from easily accessible building sensors and meter data; (3) devoting non-engineering efforts to promote building energy flexibility, standardizing data-driven energy flexibility quantification and verification processes; and (4) curating and analyzing datasets with proper description for energy flexibility assessm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Long-term carbon emission reduction potential of building retrofits with dynamically changing electricity emission factors

Buildings account for approximately 36% of the United States' total carbon emissions and building retrofits have great potential to reduce carbon emissions. Current research adopts a constant electricity emission factor although it changes over time due to the increase of renewable energy generation. Here, to accurately predict emission reduction potential of building retrofits, this study develops a novel method by using dynamically changing electricity emission factors. Using medium office buildings as an example, we predicted emission reduction of eight building retrofit measures from 2020 to 2050 in five locations in the U.S. with distinct climates and renewable adoption rates. To evaluate emission reduction potential sensitivity to the compositions of electricity generation, five scenarios for renewable energy adoptions are investigated. The results reveal several new phenomena on emission reduction potential of building retrofits for medium offices in the U.S.: (1) it decreases from 2026 to 2050; (2) it has the same trend with coal usage; and (3) it reaches the maximum under the high renewable cost scenario. Based on the results, it is recommended that building retrofits should focus on 1) improving lighting and equipment efficiency; 2) locations with higher coal usage rate, and 3) buildings under the high renewable cost scenario. The new method can also be used for predicting emission reduction potential of the building sector in the U.S. by applying to other building types and regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Whole building retrofit using vacuum insulation panels and energy performance analysis

Vacuum insulation panels (VIPs), due to their high thermal performance, provide an attractive alternative to traditional building insulation materials, especially as an option for retrofitting old, poorly insulated buildings. This article describes the complete retrofit of all exterior walls of a single-story building in a cold climate using VIPs. A recently-developed low-cost VIP, called modified atmosphere insulation (MAI), was used in this study. Two buildings of near-identical construction were studied, with one remaining unaltered and serving as the baseline while the other served as the retrofit building. The VIPs or MAI panels proved to be a feasible and durable option for retrofitting building envelopes. Thermal performance of both buildings was analyzed using in-situ temperature and heat flow sensors. Numerical models of the two buildings were created, benchmarked using experimental data and used for predictions of annual energy savings due to the addition of MAI panels to the exterior walls. The models predicted significant reduction in the annual heating energy consumption in the retrofitted building compared to the baseline building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vertical meteorological patterns and their impact on the energy demand of tall buildings

In accordance with the developing economy and growing population, an increasing number of tall buildings have been constructed over the last 20 years. In 2017, there were 144 new buildings worldwide that were 200 m or greater in height; 50% of these buildings were in China. Due to the vertical gradient impact of meteorological parameters, the energy performance of tall buildings differs from that of general buildings. Few studies exist on vertical meteorological changes using measured data at different heights. Most studies on dynamic energy simulation simulate meteorological parameters using models. This study explores vertical meteorological patterns using hourly dry-bulb temperature, relative humidity, and wind speed data from 2007 to 2017 for a 325 m meteorological tower in Beijing. The temperature decreased significantly with increasing altitude (~0.9 °C per 100 m), while the daily temperature difference decreased with increasing altitude. The absolute humidity did not change significantly with height. The wind speed increased with altitude at approximately 2 m/s per 100 m. The building simulation showed that the annual heating load at a height of 320 m increased by 85% from that at 8 m; the annual cooling load decreased by 20%. Such significant differences in thermal loads for 300-m-tall buildings confirm the need to consider vertical meteorological differences in building performance simulations for tall buildings. A greater number of measurement points at different heights improve the simulation accuracy. Finally, guidance on selecting the heights for vertical metrological measurements is provided based on the influences of building thermal loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating performance of different generative adversarial networks for large-scale building power demand prediction

We report as an unsupervised-learning data-driven model, Generative Adversarial Networks (GANs) have recently attracted a lot of attention for various applications. There is potential to apply GANs for large-scale building power demand prediction, which is needed for power grid operation. However, there are many GAN variations and it is unclear which GAN is suitable for this application. To answer this question, this paper identifies five promising GANs (Original GAN, cGAN, SGAN, InfoGAN, and ACGAN) and evaluates their performance for predicting building power demand at a large scale. Physics-based building energy models are developed to generate training and reference data. A new evaluation indicator that combines accuracy and reproducibility is proposed to evaluate the performance of different GANs in predicting building power demand. The results show that SGAN and InfoGAN are not suitable because they cannot control the number of generated building samples for different building types. The prediction performance among the Original GAN, cGAN, and ACGAN can vary depending on training sample sizes and number of building types. If the training sample size is sufficiently large, Original GAN and cGAN can predict building power demand more accurately than ACGAN with the same number of samples. If training samples are limited, Original GAN provides better accuracy than cGAN and ACGAN. When the number of building types increase, the prediction accuracy increases for cGAN, decreases for ACGAN, and remains the same for Original GAN. As a result, cGAN and Original GAN are recommended for large-scale building power demand prediction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-term carbon intensity reduction potential of K-12 school buildings in the United States

School buildings have a great potential for carbon emission reduction since their annual emission is about 72 million metric tons. Currently, more than 30% of school buildings were built before 1960 and are underperforming. To effectively reduce carbon emissions via school building retrofits, it is critical for policymakers to understand the carbon intensity reduction potential of retrofitting school buildings in different regions. Hence, this study develops a method to comprehensively assess the long-term carbon intensity reduction potential of aggregated commercial buildings on a county-by-county basis in the continental U.S. We apply this method to the K-12 school buildings including primary and secondary school buildings. Here, this paper predicts the carbon intensity reduction potential of K-12 school buildings with eight building retrofit measures from 2022 to 2050 in the continental U.S. The results reveal several interesting findings: (1) In the approximately 3,000 counties of the U.S. from 2022 to 2050, the carbon intensity reduction potential of retrofitting K-12 school buildings in each county ranges from 0.41 kg/m 2 to 40.00 kg/m 2 . (2) Even in the same climate zone, the trends of carbon intensity reduction potential from 2022 to 2050 are different depending on their electricity sources. For example, in a hot and humid climate zone, the carbon intensity reduction potential in Florida will decrease from 2044 to 2048. However, in Mississippi, the carbon intensity reduction potential from 2044 to 2046 will increase due to the termination of the nuclear energy usage. (3) Generally, reducing lighting power density leads to more carbon intensity reduction in most states, but it might not be applicable for states with high clean energy penetration, such as Washington.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Individualized empirical baselines for evaluating the energy performance of existing buildings

The evaluation of building energy performance requires a baseline for comparison. Common empirical baselines are usually used for existing buildings since they are fast and convenient. However, the same type of building at the same location will receive the same baseline despite their difference in usage. Individualized baselines by creating building energy models are possible solutions, but it is labor intensive and time-consuming. To fill the gap, this study is to develop individualized empirical baselines for existing buildings in a fast way. First, common empirical baselines are created based on survey data. Then, to get training samples, building energy models for large-scale existing buildings are created and simulated. So finally, based on simulation results, mathematical models to get individualized empirical baselines in a fast way are created. U.S. medium office buildings were used as an example to demonstrate the method. We developed 30 mathematical models for medium office buildings in two vintages (constructed before 1980 and after 1980) and 15 climate zones. The mean absolute percentage errors (MAPE) between the individualized empirical baselines and the modeled baselines for those 30 mathematical models are all lower than 5.5%. An engineer can obtain the individualized empirical baseline for an existing building in a few seconds by using the open-source tool we developed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methodology to Assess No Touch Audit Software Using Simulated Building Utility Data

This report describes a methodology developed for assessing the performance of no touch building audit tools and presents results for an available tool. Building audits are conducted in many commercial buildings to reduce building energy costs and improve building operation. Because the audits typically require significant input obtained by building engineers, they are usually only affordable for larger commercial building owners. In an effort to help small building and business owners gain the benefits of an audit at a lower cost, no touch building audit tools have been developed to remotely analyze a building's energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulating Buildings While the Design is Still in the Architect's Imagination

Very early in the design process, prior to drawing a single line, architects get information from their client or prospective client trying to understand the nature and requirements of the building that needs to be designed. The design of the building is completely fluid, as the architect considers many options in their imagination. The overall massing of the building, the general shape and form, are being considered during this early step. Even for a simple box-shaped building, the aspect ratio between the east-west and the north-south dimensions of the building can greatly impact energy consumption due to daylighting availability. The prevailing winds and building orientation can impact natural ventilation. The locations of high and low population density spaces can also impact energy use. Deciding the floor area per office workstation or the size of the auditorium will impact energy use. Does making a building two stories instead of one reduce energy impacts by reducing roof area or does the additional volume for stairs and elevators result in more energy use. Since certain types of spaces require more windows for occupants than others, the locations of those spaces will determine how much glazing each building orientation has impacting daylighting as well as heating and cooling energy. The project was an attempted first step toward creating a system tailored toward architects for this very early stage in the design process to help them understand the energy impacts of design options. The approach was not to be based on drawing the building, and instead, the main inputs would have been the size of each type of space in the building. This report describes information gathered during the development that might be of use to others developing similar software as well as some of the software that was developed during the project. Phase II funding to continue this work was not pursued due to intellectual property issues discovered during the development of the commercialization plan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

City-Scale Building Anthropogenic Heating during Heat Waves

More frequent and longer duration heat waves have been observed worldwide and are recognized as a serious threat to human health and the stability of electrical grids. Past studies have identified a positive feedback between heat waves and urban heat island effects. Anthropogenic heat emissions from buildings have a crucial impact on the urban environment, and hence it is critical to understand the interactive effects of urban microclimate and building heat emissions in terms of the urban energy balance. Here we developed a coupled-simulation approach to quantify these effects, mapping urban environmental data generated by the mesoscale Weather Research and Forecasting (WRF) coupled to Urban Canopy Model (UCM) to urban building energy models (UBEM). We conducted a case study in the city of Los Angeles, California, during a five-day heat wave event in September 2009. We analyzed the surge in city-scale building heat emission and energy use during the extreme heat event. We first simulated the urban microclimate at a high resolution (500 m by 500 m) using WRF-UCM. We then generated grid-level building heat emission profiles and aggregated them using prototype building energy models informed by spatially disaggregated urban land use and urban building density data. The spatial patterns of anthropogenic heat discharge from the building sector were analyzed, and the quantitative relationship with weather conditions and urban land-use dynamics were assessed at the grid level. The simulation results indicate that the dispersion of anthropogenic heat from urban buildings to the urban environment increases by up to 20% on average and varies significantly, both in time and space, during the heat wave event. The heat dispersion from the air-conditioning heat rejection contributes most (86.5%) of the total waste heat from the buildings to the urban environment. We also found that the waste heat discharge in inland, dense urban districts is more sensitive to extreme events than it is in coastal or suburban areas. The generated anthropogenic heat profiles can be used in urban microclimate models to provide a more accurate estimation of urban air temperature rises during heat waves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the Energy Resilience of Office Buildings: Development and Testing of a Simplified Metric for Real Estate Stakeholders

Increasing concern over higher frequency extreme weather events is driving a push towards a more resilient built environment. In recent years there has been growing interest in understanding how to evaluate, measure, and improve building energy resilience, i.e., the ability of a building to provide energy-related services in the event of a local or regional power outage. In addition to human health and safety, many stakeholders are keenly interested in the ability of a building to allow continuity of operations and minimize business disruption. Office buildings are subject to significant economic losses when building operations are disrupted due to a power outage. We propose “occupant hours lost” (OHL) as a means to measure the business productivity lost as the result of a power outage in office buildings. OHL is determined based on indoor conditions in each space for each hour during a power outage, and then aggregated spatially and temporally to determine the whole building OHL. We used quasi-Monte Carlo parametric energy simulations to demonstrate how the OHL metric varies due to different building characteristics across different climate zones and seasons. The simulation dataset was then used to develop simple regression models for assessing the impact of ten key building characteristics on OHL. The most impactful were window-to-wall ratio and window characteristics. The regression models show promise as a simple means to assess and screen for resilience using basic building characteristics, especially for non-critical facilities where it may not be viable to conduct detailed engineering analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Streamlining Building Efficiency Evaluation with DOE's Asset Score Preview

Building Energy Asset Score (Asset Score), developed by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE), is a tool to help building owners and managers assess the efficiency of a building's energy-related systems and encourage investment in cost-effective improvements. The Asset Score uses an EnergyPlus model to provide a quick assessment of building energy performance with minimum user inputs of building characteristics and identifies upgrade opportunities. Even with a reduced set of user inputs, data collection remains a challenge for wide-spread adoption, especially when evaluating a large number of buildings. To address this, Asset Score Preview was developed to allow users to enter as few as seven building characteristics to quickly assess their buildings before a more in-depth analysis. A streamlined assessment from Preview to full Asset Score provides an easy entry point and also enables users who manage a large number of buildings to screen and prioritize buildings that can benefit most from a more detailed evaluation and possible energy efficiency upgrades without intensive data collection.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Challenges and Lessons Learned from an Analysis of Three Zero Energy Buildings

Zero energy buildings, or zero energy ready buildings, which are designed and operated by public or private commercial property owners can play an important role in reducing carbon emissions. This paper discusses lessons learned and key takeaways from an in-depth analysis of three zero energy buildings that took an integrated design and construction approach to significantly reduce energy use. Two of these projects are new construction and one is a retrofit to zero energy. Findings are based on project literature review, data analysis, and in-depth interviews with the building design teams and staff who were involved during the design, construction, and operation of the buildings. The paper addresses value proposition and cost data in such a way that other building owners can replicate the strategies and technology solutions in response to regulatory mandates or organizational goals. It also provides details on operational improvements taken at each zero energy building to enhance energy performance and increase the potential for load flexibility, and discusses challenges and lessons gleaned from design teams and building staff. The findings serve as a reference for building owners, designers, engineers, contractors, or others interested in, or involved with, the design, construction, or use of new or existing buildings. The paper also includes recommended pathways for widespread adoption of zero energy strategies that can be applied in various locations.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Building simulation: Ten challenges

Buildings consume more than one-third of the world’s primary energy. Reducing energy use and greenhouse-gas emissions in the buildings sector through energy conservation and efficiency improvements constitutes a key strategy for achieving global energy and environmental goals. Building performance simulation has been increasingly used as a tool for designing, operating and retrofitting buildings to save energy and utility costs. However, opportunities remain for researchers, software developers, practitioners and policymakers to maximize the value of building performance simulation in the design and operation of low energy buildings and communities that leverage interdisciplinary approaches to integrate humans, buildings, and the power grid at a large scale. This paper presents ten challenges that highlight some of the most important issues in building performance simulation, covering the full building life cycle and a wide range of modeling scales. In conclusion, the formulation and discussion of each challenge aims to provide insights into the state-of-the-art and future research opportunities for each topic, and to inspire new questions from young researchers in this field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nexus of electrification and energy efficiency retrofit of commercial buildings at the district scale

Rapid electrification of buildings at the district scale is needed for cities to achieve climate change mitigation goals. However, most electrification studies focus on either the single building level or the city/region building stock level, and depend on the slow and uncertain process of requesting personally identifiable customer energy usage data from utilities. To answer a key question facing local policymakers: “Where can electrification proceed at scale without first upgrading the grid?” this study aims to quantify and inform building electrification impacts at the district scale using detailed building energy modeling and based on public records datasets. We explore how energy efficiency retrofits can help mitigate increased peak electric demand, and quantify impacts to energy use and carbon emissions. Building energy models of a baseline, and scenarios of simple electrification, energy retrofits, and electrification in combination with retrofits were created and simulated for 54 commercial buildings in two contiguous districts of San Francisco. A simple electrification scenario increased annual electricity consumption but reduced annual site energy usage by 15% to 17%, mainly due to replacing inefficient gas furnaces and boilers with more efficient heat pumps. Peak demand increased 7.4% for Fisherman's Wharf (e.g. within the capacity of the existing power grid), while the Design District showed a marginal decrease. Annual carbon emissions were reduced by 46% and 37%. Combining electrification with efficiency upgrades reduced peak demand by 26% and 40%, and annual carbon emissions by 63% and 64% for the two districts. Furthermore, these results indicate that impacts of electrification depend on the mix of building uses within a district, and coupling electrification with energy efficiency upgrades is an effective strategy to decarbonize buildings while maintaining or reducing the peak electric demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗