Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “blindness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Embolization of Acute Nonvariceal Upper Gastrointestinal Hemorrhage Resistant to Endoscopic Treatment: Results and Predictors of Recurrent Bleeding

Acute nonvariceal upper gastrointestinal (UGI) hemorrhage is a frequent complication associated with significant morbidity and mortality. The most common cause of UGI bleeding is peptic ulcer disease, but the differential diagnosis is diverse and includes tumors; ischemia; gastritis; arteriovenous malformations, such as Dieulafoy lesions; Mallory-Weiss tears; trauma; and iatrogenic causes. Aggressive treatment with early endoscopic hemostasis is essential for a favorable outcome. However, severe bleeding despite conservative medical treatment or endoscopic intervention occurs in 5-10% of patients, requiring surgery or transcatheter arterial embolization. Surgical intervention is usually an expeditious and gratifying endeavor, but it can be associated with high operative mortality rates. Endovascular management using superselective catheterization of the culprit vessel, < sandwich> occlusion, or blind embolization has emerged as an alternative to emergent operative intervention for high-risk patients and is now considered the first-line therapy for massive UGI bleeding refractory to endoscopic treatment. Indeed, many published studies have confirmed the feasibility of this approach and its high technical and clinical success rates, which range from 69 to 100% and from 63 to 97%, respectively, even if the choice of the best embolic agent among coils, cyanaocrylate glue, gelatin sponge, or calibrated particles remains a matter of debate. However, factors influencing clinical outcome, especially predictors of early rebleeding, are poorly understood, and few studies have addressed this issue. This review of the literature will attempt to define the role of embolotherapy for acute nonvariceal UGI hemorrhage that fails to respond to endoscopic hemostasis and to summarize data on factors predicting angiographic and embolization failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?

Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard. Materials and Methods: Forty-nine consecutive patients (73 {+-} 7.5 years, range 51-88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular to the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard. Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001). Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiological Diagnosis and Management of Epistaxis

The majority of episodes of spontaneous posterior epistaxis treated with embolisation are idiopathic in nature. The angiographic findings are typically normal. Specific angiographic signs are rare and may include the following: a tumour blush, telangiectasia, aneurysm, and/or extravasation. Selective internal carotid artery (ICA) angiography may show rare causes of epistaxis, such as traumatic or mycotic aneurysms, which require different treatment approaches. Complete bilateral selective external and internal carotid angiograms are essential to evaluation. The images should be analysed for detection of central retinal blush in the external carotid artery (ECA) and anastomoses between the branches of the ECA and ICA. Monocular blindness and stroke are two of the most severe complications. Embolisation aims to decrease flow to the bleeding nasal mucosa while avoiding necrosis of the nasal skin and palate mucosa. Embolisation is routinely performed with a microcatheter positioned in the internal maxillary artery distal to the origin of the meningeal arteries. A guiding catheter should be placed in the proximal portion of the ECA to avoid vasospasm. Embolisation with microparticles is halted when the peripheral branches of the sphenopalatine artery are occluded. The use of coils is not recommended because recurrent epistaxis may occur due to proximal embolization; moreover, the option of repeat distal embolisation is lost. The success rate of embolisation therapy (accounting for late recurrence of bleeding) varies between 71 and 94 %. Results from endoscopic surgery are quite comparable. When epistaxis is refractory to nasal packing or endoscopic surgery, embolisation is the treatment of choice in some centres.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sustained Benefit at 2 Years for Covered Stents Versus Bare-Metal Stents in Long SFA Lesions: The VIASTAR Trial

PurposeThe hypothesis that covered stents are superior to bare-metal stents (BMS) in long femoropopliteal artery disease was tested. The one-year results of the VIASTAR trial revealed a patency benefit of covered stents in the treatment-per-protocol (TPP) analysis only.MethodsA prospective, randomized, single-blind, multicenter study evaluated 141 patients with symptomatic peripheral arterial disease (PAD) after treatment with heparin-bonded covered stents (VIABAHN{sup ®} Endoprosthesis) or BMS. Clinical outcomes and patency rates were assessed at 1, 6, 12, and 24 months. Mean lesion length was 19.0 ± 6.3 cm in the VIABAHN{sup ®} versus 17.3 ± 6.6 cm in the BMS group.ResultsThe 24-month primary patency rates in the VIABAHN{sup ®} and BMS group were: intention-to-treat 63.1 (95 % CI 0.52–0.76) versus 41.2 % (95 % CI 0.29–0.57; log rank p = 0.04) and TPP 69.4 (95 % CI 0.58–0.83) versus 40.0 % (95 % CI 0.28–0.56; log rank p = 0.004). Freedom from target-lesion-revascularization (TLR) was 79.4 (95 % CI 0.70–0.90) versus 73.0 % (95 % CI 0.63–0.85) for VIABAHN{sup ®} versus BMS (log rank p = 0.37). For the TPP group in lesions ≥20 cm, the 24-month patency rates were 65.2 (95 % CI 0.50–0.85) versus 26.7 % (95 % CI 0.12–0.59; log rank p = 0.004) for VIABAHN{sup ®} versus BMS, and freedom from TLR was 80.0 (95 % CI 0.68–0.94) versus 61.9 % (95 % CI 0.44–0.87; log rank p = 0.13). The ankle brachial index was 0.89 ± 0.18 versus 0.91 ± 0.17 (p = 0.76) at 24-month in the VIABAHN{sup ®} versus the BMS group, respectively.ConclusionAt 24-month, this trial in PAD patients with long femoropopliteal lesions demonstrated a significantly improved primary patency rate for heparin-bonded covered stents compared to BMS, however, without a significant impact on clinical outcomes and TLR rate (Reg. Nr. ISRCTN48164244)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Value of Rotational Venography Versus Anterior–Posterior Venography in 100 Consecutive IVC Filter Retrievals

PurposeAccurately detecting inferior vena cava (IVC) filter complications is important for safe and successful retrieval as tip-embedded filters require removal with non-standard techniques. Venography prior to IVC filter retrieval has traditionally used a single anterior–posterior (AP) projection. This study compares the utility of rotational venography to AP venography prior to IVC filter removal.Materials and MethodsThe rotational venograms from 100 consecutive IVC filter retrievals over a 35-month period were evaluated retrospectively. The AP view of the rotational venogram was examined separately from the full series by a radiologist blinded to alternative imaging and operative findings. The venograms were evaluated for tip embedding, filter fracture, filter thrombus, and IVC thrombus. Statistical analysis was performed.ResultsUsing operative findings and peri-procedural imaging as the reference standard, tip embedding occurred in 59 of the 100 filters (59 %). AP venography was used to correctly identify 31 tip-embedded filters (53 % sensitivity) with two false positives (95 % specificity) for an accuracy of 70 %. Rotational venography was used to correctly identify 58 tip-embedded filters (98 % sensitivity) with one false positive (98 % specificity) for an accuracy of 98 %. A significant difference was found in the sensitivities of the two diagnostic approaches (P < .01). Other findings of thrombus and filter fracture were not significantly different between the two groups.ConclusionRotational venograms allow for more accurate detection of tip-embedded IVC filters compared to AP views alone. As this determines the approach taken, rotational venograms are helpful if obtained prior to IVC filter retrieval.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characteristics of a New X-Ray Imaging System for Interventional Procedures: Improved Image Quality and Reduced Radiation Dose

PurposeTo compare image quality and radiation exposure between a new angiographic imaging system and the preceding generation system during uterine artery embolization (UAE).Materials and MethodsIn this retrospective, IRB-approved two-arm study, 54 patients with symptomatic uterine fibroids were treated with UAE on two different angiographic imaging systems. The new system includes optimized acquisition parameters and real-time image processing algorithms. Air kerma (AK), dose area product (DAP) and acquisition time for digital fluoroscopy (DF) and digital subtraction angiography (DSA) were recorded. Body mass index was noted as well. DF image quality was assessed objectively by image noise measurements. DSA image quality was rated by two blinded, independent readers on a four-rank scale. Statistical differences were assessed with unpaired t tests and Wilcoxon rank-sum tests.ResultsThere was no significant difference between the patients treated on the new (n = 36) and the old system (n = 18) regarding age (p = 0.10), BMI (p = 0.18), DF time (p = 0.35) and DSA time (p = 0.17). The new system significantly reduced the cumulative AK and DAP by 64 and 72%, respectively (median 0.58 Gy and 145.9 Gy*cm{sup 2} vs. 1.62 Gy and 526.8 Gy*cm{sup 2}, p < 0.01 for both). Specifically, DAP for DF and DSA decreased by 59% (75.3 vs. 181.9 Gy*cm{sup 2}, p < 0.01) and 78% (67.6 vs. 312.2 Gy*cm{sup 2}, p < 0.01), respectively. The new system achieved a significant decrease in DF image noise (p < 0.01) and a significantly better DSA image quality (p < 0.01).ConclusionsThe new angiographic imaging system significantly improved image quality and reduced radiation exposure during UAE procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

End-hole Versus Microvalve Infusion Catheters in Patients Undergoing Drug-Eluting Microspheres-TACE for Solitary Hepatocellular Carcinoma Tumors: A Retrospective Analysis

Introduction: Pre-transplant locoregional therapy for hepatocellular carcinoma (HCC) during bridge-to-transplant impacts recurrence and survival rates following liver transplantation. Optimizing the effectiveness of transarterial chemoembolization (TACE) in this population is imperative, and microvalve infusion catheters offer a means of such improvement. Methods: All treatment-naive patients with solitary HCC tumors < 6.5 cm who underwent drug-eluting microspheres (DEM) TACE between 04/2015 and 08/2017 were retrospectively reviewed. Eighty-eight included patients underwent DEM-TACE with either standard end-hole catheters (EH) or microvalve infusion catheters (MVI). The EH (n = 70) and MVI (n = 18) cohorts had similar baseline tumor size, laboratory values, and tumor etiologies. Results: Initial objective response rates were significantly higher in MVI vs. EH (100% vs. 76.5%, p = 0.019). There was no difference in adverse events between groups (p = 0.265). MVI patients exhibited lower AST (p = 0.003) and ALT (p = 0.044) at 6 months. Blinded pathological analysis of explanted livers showed greater concentrations of microspheres within the tumor relative to the surrounding tissue in MVI explants (88.7 ± 10.6%) versus the EH explants (55.3 ± 32.7%) (p = 0.002). There was significantly higher percentage tumor necrosis in the MVI group (89.0 ± 2.2%) compared with the EH group (56.1 ± 44.5%) (p = 0.006). Conclusion: In this retrospective study of a single-center cohort, DEM-TACE procedures with MVI were associated with improved tumor response, increased deposition of microspheres within tumor tissue, and higher percentage tumor necrosis at explant relative to those performed using EH catheters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Embolization After Carotid Artery Stenting with Mesh-Covered Stent: Role of Diffusion-Weighted Magnetic Resonance Imaging as Pre-procedural Predictor and Discriminant Between Intra- and Post-procedural Events

Objectives: To evaluate the incidence and the time of onset of early micro-embolism after CAS (carotid artery stenting) with two different mesh-covered stents and to assess the role of DW-MRI (Diffusion-weighted magnetic resonance imaging) in their prediction. Methods: Single-institution prospective study including 50 patients (33 male, median age 74 years) who underwent CAS with Roadsaver{sup ®} or CGuard™. All patients with primary stenosis (37/50, 74%) had carotid plaque DW-MRI pre-procedure, with both qualitative evaluation of the hyperintensity and ADC (apparent diffusion coefficient) measurement of the plaque. All patients had brain DW-MRI pre-procedure, at 1 h, 24 h and 30 days post-procedure to evaluate the appearance of hyperintense lesions over time. Imaging analysis was performed in a double-blinded fashion by two radiologists. Results: There were no statistically significant differences between the two stents both in the incidence at 1 h (P = 0.23) and 24 h (P = 0.36) and in the volume of new DWI hyperintense brain lesions at 24 h (P = 0.27). Thirty-four new asymptomatic lesions in 19 patients (38%) were reported: 4 (11.8%) at 1 h, 30 (88.2%) at 24 h. The 30-day DWI-MR showed complete resolution of all lesions and no evidence of new lesion. The incidence of new lesions at 24 h resulted significantly higher in patients with DWI hyperintense carotid plaques (12/16, 75% vs. 0/21, 0%, P < 0.0001). This result was paralleled by the difference in ADC value (0.83 ± 0.21 vs. 1.42 ± 0.52). Conclusion: The majority of early asymptomatic brain lesion occurred during the first 24 h after CAS. Pre-procedure high DWI signal of the plaque was associated with an increased incidence of post-procedure microembolizations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Randomized Freeway Stent Study: Drug-Eluting Balloons Outperform Standard Balloon Angioplasty for Postdilatation of Nitinol Stents in the SFA and PI Segment

Purpose: The prospective randomized multicenter Freeway study evaluated the possible hemodynamic and clinical benefits of primary stent insertion followed by percutaneous transluminal angioplasty (PTA) with drug-eluting balloons (DEB) over post-stent insertion PTA with standard balloons in the treatment of symptomatic femoropopliteal arteriosclerotic lesions. Methods: In total, 204 patients in 13 centers in Germany and Austria were enrolled and randomized to primary stenting followed by either FREEWAY™ drug-eluting balloon or standard PTA balloon angioplasty. The primary endpoint was the rate of clinically driven target lesion revascularization (TLR) at 6 months; the secondary endpoints include TLR rate at 12 months and primary patency, shift in Rutherford classification, ankle–brachial index (ABI) and major adverse events (MAE) at 6 and 12 months. Lesion characteristics and vessel patency were analyzed by an independent and blinded corelab. Results: At 6-month and 12-month follow-up, TLR rate was lower in the DEB arm compared to standard PTA but did not reach statistical significance (4.1% vs. 9.0% p = 0.234 and 7.9% vs. 17.7% p = 0.064, respectively). Primary patency was significantly better for patients treated with the DEB at 6 months (90.3% vs. 69.8% p = 0.001) and 12 months (77.4% vs. 61.0% p = 0.027). Improvement in Rutherford classifications was likewise significantly better for patients in the DEB group at 6 (94.9% vs. 84.3% p = 0.027) and 12 months (95.5% vs. 79.9% p = 0.003). The percentage of patients with an improved ABI of 1.0–1.2 was significantly higher in the DEB group compared to the PTA group at 6 months (55.3% vs. 35.3%; p = 0.015) but without significant difference at 12 months (48.2% vs. 32.9%; p = 0.055). At 6 months, rate of major adverse events (MAE) was 1% in both arms, and at 12 months 2.2% for the DEB and 3.8% for the PTA group. Conclusion: The Freeway Stent Study shows that the usage of DEB as a restenosis prophylaxis seems to be safe and feasible. The 12-month follow-up results give a clear sign in favor of the DEB group.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Discretization effects in the finite element simulation of seismic waves in elastic and elastic-plastic media

Presented here is a numerical investigation that (re-)appraises standard rules for space/time discretization in seismic wave propagation analyses. Although the issue is almost off the table of research, situations are often encountered where (established) discretization criteria are not observed and inaccurate results possibly obtained. In particular, a detailed analysis of discretization criteria is carried out for wave propagation through elastic and elastic-plastic media. The establishment of such criteria is especially important when accurate prediction of high-frequency motion is needed and/or in the presence of highly non-linear material models. Current discretization rules for wave problems in solids are critically assessed as a conditio sine qua non for improving verification/validation procedures in applied seismology and earthquake engineering. For this purpose, the propagation of shear waves through a 1D stack of 3D finite elements is considered, including the use of wide-band input motions in combination with both linear elastic and non-linear elastic-plastic material models. The blind use of usual rules of thumb is shown to be sometimes debatable, and an effort is made to provide improved discretization criteria. Possible pitfalls of wave simulations are pointed out by highlighting the dependence of discretization effects on time duration, spatial location, material model and specific output variable considered.

58 GEOSCIENCES↗

Redefining the Practice of Peer Review Through Intelligent Automation Part 2: Data-Driven Peer Review Selection and Assignment

In conventional radiology peer review practice, a small number of exams (routinely 5% of the total volume) is randomly selected, which may significantly underestimate the true error rate within a given radiology practice. An alternative and preferable approach would be to create a data-driven model which mathematically quantifies a peer review risk score for each individual exam and uses this data to identify high risk exams and readers, and selectively target these exams for peer review. An analogous model can also be created to assist in the assignment of these peer review cases in keeping with specific priorities of the service provider. An additional option to enhance the peer review process would be to assign the peer review cases in a truly blinded fashion. In addition to eliminating traditional peer review bias, this approach has the potential to better define exam-specific standard of care, particularly when multiple readers participate in the peer review process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Redefining the Practice of Peer Review Through Intelligent Automation—Part 3: Automated Report Analysis and Data Reconciliation

One method for addressing existing peer review limitations is the assignment of peer review cases on a completely blinded basis, in which the peer reviewer would create an independent report which can then be cross-referenced with the primary reader report of record. By leveraging existing computerized data mining techniques, one could in theory automate and objectify the process of report data extraction, classification, and analysis, while reducing time and resource requirements intrinsic to manual peer review report analysis. Once inter-report analysis has been performed, resulting inter-report discrepancies can be presented to the radiologist of record for review, along with the option to directly communicate with the peer reviewer through an electronic data reconciliation tool aimed at collaboratively resolving inter-report discrepancies and improving report accuracy. All associated report and reconciled data could in turn be recorded in a referenceable peer review database, which provides opportunity for context and user-specific education and decision support.

42 ENGINEERING↗

Automatic Determination of the Need for Intravenous Contrast in Musculoskeletal MRI Examinations Using IBM Watson’s Natural Language Processing Algorithm

Magnetic resonance imaging (MRI) protocoling can be time- and resource-intensive, and protocols can often be suboptimal dependent upon the expertise or preferences of the protocoling radiologist. Providing a best-practice recommendation for an MRI protocol has the potential to improve efficiency and decrease the likelihood of a suboptimal or erroneous study. The goal of this study was to develop and validate a machine learning-based natural language classifier that can automatically assign the use of intravenous contrast for musculoskeletal MRI protocols based upon the free-text clinical indication of the study, thereby improving efficiency of the protocoling radiologist and potentially decreasing errors. We utilized a deep learning-based natural language classification system from IBM Watson, a question-answering supercomputer that gained fame after challenging the best human players on Jeopardy! in 2011. We compared this solution to a series of traditional machine learning-based natural language processing techniques that utilize a term-document frequency matrix. Each classifier was trained with 1240 MRI protocols plus their respective clinical indications and validated with a test set of 280. Ground truth of contrast assignment was obtained from the clinical record. For evaluation of inter-reader agreement, a blinded second reader radiologist analyzed all cases and determined contrast assignment based on only the free-text clinical indication. In the test set, Watson demonstrated overall accuracy of 83.2% when compared to the original protocol. This was similar to the overall accuracy of 80.2% achieved by an ensemble of eight traditional machine learning algorithms based on a term-document matrix. When compared to the second reader’s contrast assignment, Watson achieved 88.6% agreement. When evaluating only the subset of cases where the original protocol and second reader were concordant (n = 251), agreement climbed further to 90.0%. The classifier was relatively robust to spelling and grammatical errors, which were frequent. Implementation of this automated MR contrast determination system as a clinical decision support tool may save considerable time and effort of the radiologist while potentially decreasing error rates, and require no change in order entry or workflow.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Genomic aberrations in normal tissue adjacent to HER2-amplified breast cancers: field cancerization or contaminating tumor cells?

Field cancerization effects as well as isolated tumor cell foci extending well beyond the invasive tumor margin have been described previously to account for local recurrence rates following breast conserving surgery despite adequate surgical margins and breast radiotherapy. To look for evidence of possible tumor cell contamination or field cancerization by genetic effects, a pilot study (Study 1: 12 sample pairs) followed by a verification study (Study 2: 20 sample pairs) were performed on DNA extracted from HER2-positive breast tumors and matching normal adjacent mammary tissue samples excised 1–3 cm beyond the invasive tumor margin. High-resolution molecular inversion probe (MIP) arrays were used to compare genomic copy number variations, including increased HER2 gene copies, between the paired samples; as well, a detailed histologic and immunohistochemical (IHC) re-evaluation of all Study 2 samples was performed blinded to the genomic results to characterize the adjacent normal tissue composition bracketing the DNA-extracted samples. Overall, 14/32 (44 %) sample pairs from both studies produced genome-wide evidence of genetic aberrations including HER2 copy number gains within the adjacent normal tissue samples. The observed singleparental origin of monoallelic HER2 amplicon haplotypes shared by informative tumor–normal pairs, as well as commonly gained loci elsewhere on 17q, suggested the presence of contaminating tumor cells in the genomically aberrant normal samples. Histologic and IHC analyses identified occult 25–200 lm tumor cell clusters overexpressing HER2 scattered in more than half, but not all, of the genomically aberrant normal samples re-evaluated, but in none of the genomically normal samples. These genomic and microscopic findings support the conclusion that tumor cell contamination rather than genetic field cancerization represents the likeliest cause of local clinical recurrence rates following breast conserving surgery, and mandate caution in assuming the genomic normalcy of histologically benign appearing peritumor breast tissue.

59 BASIC BIOLOGICAL SCIENCES↗

Sandia fracture challenge 2: Sandia California's modeling approach

The second Sandia Fracture Challenge illustrates that predicting the ductile fracture of Ti-6Al-4V subjected to moderate and elevated rates of loading requires thermomechanical coupling, elasto-thermo-poro-viscoplastic constitutive models with the physics of anisotropy and regularized numerical methods for crack initiation and propagation. We detail our initial approach with an emphasis on iterative calibration and systematically increasing complexity to accommodate anisotropy in the context of an isotropic material model. Blind predictions illustrate strengths and weaknesses of our initial approach. We then revisit our findings to illustrate the importance of including anisotropy in the failure process. Furthermore, mesh-independent solutions of continuum damage models having both isotropic and anisotropic yields surfaces are obtained through nonlocality and localization elements.

36 MATERIALS SCIENCE↗

Predicting the reliability of an additively-manufactured metal part for the third Sandia fracture challenge by accounting for random material defects

We describe an approach to predict failure in a complex, additively-manufactured stainless steel part as defined by the third Sandia Fracture Challenge. A viscoplastic internal state variable constitutive model was calibrated to fit experimental tension curves in order to capture plasticity, necking, and damage evolution leading to failure. Defects such as gas porosity and lack of fusion voids were represented by overlaying a synthetic porosity distribution onto the finite element mesh and computing the elementwise ratio between pore volume and element volume to initialize the damage internal state variables. These void volume fraction values were then used in a damage formulation accounting for growth of these existing voids, while new voids were allowed to nucleate based on a nucleation rule. Blind predictions of failure are compared to experimental results. The comparisons indicate that crack initiation and propagation were correctly predicted, and that an initial porosity field superimposed as higher initial damage may provide a path forward for capturing material strength uncertainty. Here, the latter conclusion was supported by predicted crack face tortuosity beyond the usual mesh sensitivity and variability in predicted strain to failure; however, it bears further inquiry and a more conclusive result is pending compressive testing of challenge-built coupons to de-convolute materials behavior from the geometric influence of significant porosity.

36 MATERIALS SCIENCE↗

Revisiting the first Sandia Fracture Challenge with transient deformation heating and strain localization considerations

In this study, we present a systematic experimental study and accompanying theoretical analysis of the dependence of ductile fracture on strain localization, strain hardening rates, deformation-induced thermal softening, and transient heat conduction under spatially uniform as well as spatially heterogeneous deformation. Spatially uniform cases are studied via standard dogbone shaped specimens subject to uniaxial tension. Spatially heterogeneous deformation is studied via the so-called Sandia Fracture Challenge (SFC) specimen, which is a standard compact tension specimen modified with three machined holes in front of a blunt notch. We utilize the same precipitation hardened martensitic stainless steel used in the first SFC experiments, i.e. 15-5 PH with an H1075 heat treatment. We also study 15-5 PH in Condition A and with the H900 heat treatment, each of which has a different hardening behavior and ductility. We find that the ductility does not correlate with the deformation to first crack initiation in the SFC specimen. Instead, hardening rates are better correlated. Moreover, a re-examination finds that an accurate calibration of the hardening rates is strongly correlated with accurate blind predictions of ductile fracture in the SFC specimens. Given that thermal softening can greatly affect hardening rates, we provided a thermographic analysis of deformation-induced heating and transient heat transfer in both the dogbone shaped samples and the SFC specimens. Transient heating in stainless steels is found to have first-order effects on the strain at the onset of necking, strain to fracture, as well as strain localization and ductile fracture in complex geometries even under so-called quasi-static loading rates.

42 ENGINEERING↗

Development of Aluminum LEKIDs for Balloon-Borne Far-IR Spectroscopy

We are developing lumped-element kinetic inductance detectors (LEKIDs) designed to achieve background-limited sensitivity for far-infrared (FIR) spectroscopy on a stratospheric balloon. The spectroscopic terahertz airborne receiver for farinfrared exploration will study the evolution of dusty galaxies with observations of the [CII] 158µm and other atomic fine-structure transitions at z = 0.5–1.5, both through direct observations of individual luminous infrared galaxies, and in blind surveys using the technique of line intensity mapping. The spectrometer will require large format (~1800 detectors) arrays of dual-polarization sensitive detectors with NEPs of 1 × 10 –17 W Hz –1/2 . The low-volume LEKIDs are fabricated with a single layer of aluminum (20-nm-thick) deposited on a crystalline silicon wafer, with resonance frequencies of 100–250MHz. The inductor is a single meander with a linewidth of 0.4µm, patterned in a grid to absorb optical power in both polarizations. As a result, the meander is coupled to a circular waveguide, fed by a conical feedhorn. Initial testing of a small array prototype has demonstrated good yield and a median NEP of 4 × 10 –18 W Hz –1/2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗