Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Three-dimensional electrical resistivity model of a nuclear waste disposal site

A three-dimensional (3D) modeling study was completed on a very large electrical resistivity survey conducted at a nuclear waste site in eastern Washington. The acquisition included 47 pole-pole two dimensional (2D) resistivity profiles collected along parallel and orthogonal lines over an area of 850 m×570 m. The data were geo-referenced and inverted using EarthImager3D (EI3D). EI3D runs on a Microsoft 32-bit operating system (e.g. WIN-2K, XP) with a maximum usable memory of 2 GB. The memory limits the size of the domain for the inversion model to 200 m×200 m, based on the survey electrode density. Therefore, a series of increasing overlapping models were run to evaluate the effectiveness of dividing the survey area into smaller subdomains. The results of the smaller subdomains were compared to the inversion results of a single domain over a larger area using an upgraded form of EI3D that incorporates multi-processing capabilities and 32 GB of RAM memory. The contours from the smaller subdomains showed discontinuity at the boundaries between the adjacent models, which do not match the hydrogeologic expectations given the nature of disposal at the site. At several boundaries, the contours of the low resistivity areas close, leaving the appearance of disconnected plumes or open contours at boundaries are not met with a continuance of the low resistivity plume into the adjacent subdomain. The model results of the single large domain show a continuous monolithic plume within the central and western portion of the site, directly beneath the elongated trenches. It is recommended that where possible, the domain not be subdivided, but instead include as much of the domain as possible given the memory of available computing resources.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Obtaining identical results with double precision global accuracy on different numbers of processors in parallel particle Monte Carlo simulations

We describe and compare different approaches for achieving numerical reproducibility in photon Monte Carlo simulations. Reproducibility is desirable for code verification, testing, and debugging. Parallelism creates a unique problem for achieving reproducibility in Monte Carlo simulations because it changes the order in which values are summed. This is a numerical problem because double precision arithmetic is not associative. Parallel Monte Carlo, both domain replicated and decomposed simulations, will run their particles in a different order during different runs of the same simulation because the non-reproducibility of communication between processors. In addition, runs of the same simulation using different domain decompositions will also result in particles being simulated in a different order. In [1], a way of eliminating non-associative accumulations using integer tallies was described. This approach successfully achieves reproducibility at the cost of lost accuracy by rounding double precision numbers to fewer significant digits. This integer approach, and other extended and reduced precision reproducibility techniques, are described and compared in this work. Increased precision alone is not enough to ensure reproducibility of photon Monte Carlo simulations. Non-arbitrary precision approaches require a varying degree of rounding to achieve reproducibility. For the problems investigated in this work double precision global accuracy was achievable by using 100 bits of precision or greater on all unordered sums which where subsequently rounded to double precision at the end of every time-step.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reduced-order modeling on a near-term quantum computer

Quantum computing is an advancing area of research in which computer hardware and algorithms are developed to take advantage of quantum mechanical phenomena. In recent studies, quantum algorithms have shown promise in solving linear systems of equations as well as systems of linear ordinary differential equations (ODEs) and partial differential equations (PDEs). Reducedorder modeling (ROM) algorithms for studying fluid dynamics have shown success in identifying linear operators that can describe flowfields, where dynamic mode decomposition (DMD) is a particularly useful method in which a linear operator is identified from data. In this work, DMD is reformulated as an optimization problem to propagate the state of the linearized dynamical system on a quantum computer. This reformulation was chosen as a means of facilitating implementation on a near-term quantum computer. Quadratic unconstrained binary optimization (QUBO), a technique for optimizing quadratic polynomials in binary variables, allows for quantum annealing algorithms to be applied. A quantum circuit model (quantum approximation optimization algorithm, QAOA) is utilized to obtain predictions of the state trajectories. Results are shown for the quantum-ROM predictions for flow over a 2D cylinder at Re = 220 and flow over a NACA0009 airfoil at Re = 500 and α = 15°. The quantum-ROM predictions are found to depend on the number of bits utilized for a fixed point representation and the truncation level of the DMD model. Comparisons with DMD predictions from a classical computer algorithm are made, as well as an analysis of the computational complexity and prospects for future, more fault-tolerant quantum computers.

97 MATHEMATICS AND COMPUTING↗

The effect of thermal-aging on the microstructure and mechanical properties of 9Cr ferritic/martensitic ODS alloy

In this paper, the thermal-stability of 9Cr F/M ODS alloy was evaluated by the aging treatment in the air at 700 degrees C for 10 h, 100 h, 1000 h, and 2005 h. The variations of mechanical properties with different aging periods were tested in terms of tensile testing and vickers microhardness. And the microstructural evolution of strengthening particles and grain morphologies in the 9Cr F/M ODS alloys were characterized using field emission scanning electron microscopy, transmission electron microscopy and high-energy X-ray diffraction. It was found that the as-rolled 9Cr F/M ODS alloy slightly recovered without recrystallization during the initial stage of less than 10 h aging time, resulting in the slight loss of tensile strength and microhardness and the increase of elongation. With the aging time prolonged to 2005 h, several of nano-sized Y-Ti-O particles coarsened and the composition changed to Y-Ti-Al-O, and the number density of large size nitride precipitations increased and the composition also changed from TiN to (Ti,AI)N. Meanwhile, some of grains tend to grow up in some preferential directions due to the zener pinning effect by the localized uneven distributed particles inside the grains, causing more particles, especially the particles with a size of larger than 40 nm, located at grain boundaries. These microstructural evolutions lead to the increasing of microhardness and a little bit decreasing of eleongation during 10 h-2005 h, and the increasing of tensile strength during 10 h-1000 h with the subsequent slight decreasing during 1000 h-2005 h. In conclusion, 9Cr F/M alloy shows a relatively good thermal-aging stability at 700 degrees C for 2005 h.

36 MATERIALS SCIENCE↗

Coprecipitation of nickel zinc malonate: A facile and reproducible synthesis route for Ni{sub 1−x}Zn{sub x}O nanoparticles and Ni{sub 1−x}Zn{sub x}O/ZnO nanocomposites via pyrolysis

Nanoparticles of Ni{sub 1−x}Zn{sub x}O and Ni{sub 1−x}Zn{sub x}O/ZnO, which can be good candidates for selective gas sensors, were successfully obtained via a two-step synthetic route, in which the nickel zinc malonate precursor was first synthesized by co-precipitation from an aqueous solution, followed by pyrolysis in air at a relatively low temperature (~500 °C). The precursor was characterized by ICP-AES, FTIR and TG and the results indicate the molecular structure of the precursor to be compatible with Ni{sub 1−x}Zn{sub x}(OOCCH{sub 2}COO)·2H{sub 2}O. The decomposition product, characterized using various techniques (FTIR, XRD, ToF-SIMS, SEM, TEM and XPS), was established to be a doped nickel oxide (Ni{sub 1−x}Zn{sub x}O for 0.01≤x≤0.1) and a composite material (Ni{sub 1−x}Zn{sub x}O/ZnO for 0.2≤x≤0.5). To elucidate the form in which the Zn is present in the NiO structure, three analytical techniques were employed: ToF-SIMS, XRD and XPS. While ToF SIMS provided a direct evidence of the presence of Zn in the NiO crystal structure, XRD showed that Zn actually substitutes Ni in the structure and XPS is a bit more specific by indicating that the Zn is present in the form of Zn{sup 2+} ions. - Highlights: • Coprecipitation synthesis of nickel zinc malonate single bath precursor was achieved. • The as synthesized precursors are an homogeneous mixture of nickel and zinc malonate. • XRD, ToF-SIMS, XPS, SEM and TEM was used to characterized decomposition products. • Ni{sub 1−x}Zn{sub x}O nanoparticles (0.01≤x≤0.1) formed after pyrolysis (~500 °C) of precursor. • Ni{sub 1−x}Zn{sub x}O/ZnO nanocomposite (0.2≤x≤0.5) formed after pyrolysis at 500 °C of precursor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural characteristics and elevated temperature mechanical properties of AJ62 Mg alloy

Structure and mechanical properties of the novel casting AJ62 (Mg–6Al–2Sr) alloy developed for elevated temperature applications were studied. The AJ62 alloy was compared to commercial casting AZ91 (Mg–9Al–1Zn) and WE43 (Mg–4Y–3RE) alloys. The structure was examined by scanning electron microscopy, x-ray diffraction and energy dispersive spectrometry. Mechanical properties were characterized by Viskers hardness measurements in the as-cast state and after a long-term heat treatment at 250 °C/150 hours. Compressive mechanical tests were also carried out both at room and elevated temperatures. Compressive creep tests were conducted at a temperature of 250 °C and compressive stresses of 60, 100 and 140 MPa. The structure of the AJ62 alloy consisted of primary α-Mg dendrites and interdendritic nework of the Al{sub 4}Sr and massive Al{sub 3}Mg{sub 13}Sr phases. By increasing the cooling rate during solidification from 10 and 120 K/s the average dendrite arm thickness decreased from 18 to 5 μm and the total volume fraction of the interdendritic phases from 20% to 30%. Both factors slightly increased hardness and compressive strength. The room temperature compressive strength and hardness of the alloy solidified at 30 K/s were 298 MPa and 50 HV 5, i.e. similar to those of the as-cast WE43 alloy and lower than those of the AZ91 alloy. At 250 °C the compressive strength of the AJ62 alloy decreased by 50 MPa, whereas those of the AZ91 and WE43 alloys by 100 and 20 MPa, respectively. The creep rate of the AJ62 alloy was higher than that of the WE43 alloy, but significantly lower in comparison with the AZ91 alloy. Different thermal stabilities of the alloys were discussed and related to structural changes during elevated temperature expositions. - Highlights: • Small effect of cooling rate on the compressive strength and hardness of AJ 62 • A bit lower compressive strength of AJ 62 compared to AZ91 at room temperature • Higher resistance of the AJ 62 alloy to the creep process in compression compared to AZ91 • Excellent thermal stability and creep resistance of the alloy WE 43 • Improved thermal stability and creep resistance in order WE43 > AJ62 >> AZ91.

36 MATERIALS SCIENCE↗

Structure study of Bi{sub 4}Ti{sub 3}O{sub 12} produced via mechanochemically assisted synthesis

Nanosized bismuth titanate was prepared via high-energy ball milling process through mechanically assisted synthesis directly from their oxide mixture of Bi{sub 2}O{sub 3} and TiO{sub 2}. Only Bi{sub 4}Ti{sub 3}O{sub 12} phase was formed after 3 h of milling time. The excess of 3 wt% Bi{sub 2}O{sub 3} added in the initial mixture before milling does not improve significantly the formation of Bi{sub 4}Ti{sub 3}O{sub 12} phase comparing to stoichiometric mixture. The formed phase was amorphized independently of the milling time. The Rietveld analysis was adopted to determine the crystal structure symmetry, amount of amorphous phase, crystallite size and microstrains. With increasing the milling time from 3 to 12 h, the particle size of formed Bi{sub 4}Ti{sub 3}O{sub 12} did not reduced significantly. That was confirmed by SEM and TEM analysis. The particle size was less than 20 nm and show strong tendency to agglomeration. The electron diffraction pattern indicates that Bi{sub 4}Ti{sub 3}O{sub 12} crystalline powder is embedded in an amorphous phase of bismuth titanate. Phase composition and atom ratio in BIT ceramics were determined by X-ray diffraction and EDS analysis.

36 MATERIALS SCIENCE↗

Microstructure and electrical properties in W/Nb co-doped Aurivillius phase Bi{sub 4}Ti{sub 3}O{sub 12} piezoelectric ceramics

Highlights: • W/Nb codoped BIT ceramics were prepared by the mixed oxides route. • High nd{sup 0} electronic configuration of W/Nb reduces the lattice distortion and T{sub C}. • Oxygen vacancy is responsible for dielectric relaxation and DC conduction process. • W/Nb additives significantly enhanced the piezoelectric coefficient d{sub 33} value. • BWNb-10 ceramics possessed large remnant polarization and a wide sintering window. - Abstract: Aurivillius-type Bi{sub 4}Ti{sub 3-x}W{sub x/2}Nb{sub x/2}O{sub 12} ceramics were prepared by a conventional solid-state sintering method. The XRD patterns demonstrated that all compositions were a single three layered crystalline structure, involving a reduction of lattice distortion with an increase in W/Nb doping level. The electrical properties including dielectric, electrical conduction and piezoelectric properties were tailored by W/Nb additives. The Curie-temperature decreased, whereas the electrical resistivity drastically increased with introduction of W/Nb donor dopants. As a result, a high electric field can be applied during the poling process. The Bi{sub 4}Ti{sub 2.9}W{sub 0.05}Nb{sub 0.05}O{sub 12} ceramics exhibited optimum piezoelectric coefficient (d{sub 33} ∼22.8 pC/N), large remnant polarization (2P{sub r} ∼26.8 μC/cm{sup 2} @ 200 °C) together with a high Curie temperature (T{sub C} ∼635 °C). Furthermore, this composition possessed a wide sintering window with outstanding piezoelectric properties. These parameters indicate that Bi{sub 4}Ti{sub 2.9}W{sub 0.05}Nb{sub 0.05}O{sub 12}-based ceramic is a promising candidate for high temperature piezoelectric applications.

36 MATERIALS SCIENCE↗

Influence of high energy ball milling on structural parameters, cation distribution and magnetic enhancement of nanosized Co0.3Zn0.7Fe2O4

Highlights: • Magnetic enhancement in mechanically activated nanosized Co{sub 0.3}Zn{sub 0.7}Fe{sub 2}O{sub 4} ferites. • Influence of crystal structure, cation distribution and stress anisotropy on magnetic and hyperfine properties. • A simple method for estimation of cation distribution of ferrites has been proposed. • Probing core-shell type magnetic structure of ferrite nanoparticles by infield Mössbauer and dc magnetic measurement. • Memory effect in the dc magnetization. - Abstract: Herein, we report the role of mechanical activation in modifying the structural, microstructural, magnetic and hyperfine parameters of nanosized Co{sub 0.3}Zn{sub 0.7}Fe{sub 2}O{sub 4} having average particle size ∼16.6 nm synthesized via coprecipitation method followed by high energy ball milling with cation distribution (Zn{sup 2+}{sub 0.61}Fe{sup 3+}{sub 0.39}){sub A} [Co{sup 2+}{sub 0.3}Zn{sup 2+}{sub 0.09}Fe{sup 3+}{sub 1.61}]{sub B}O{sub 4}. The values of the blocking temperature and Curie temperature of the sample are 220 and 270 K, respectively. The values of saturation magnetization at 300 and 5 K are 59 and 88 emu g{sup −1}and those of the coercivity at 100 and 5 K are 400 and 5000 Oe, respectively. The values of the magnetic parameters of the sample are greater than those of its counterparts synthesized by chemical methods. A model for precise estimation of the cation distribution of ferrites has been proposed. Moreover, the memory effect obtained in the dc magnetization of the sample can be used for generating, storing and retrieving binary bit pattern.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Machine learning for materials science: Barriers to broader adoption

We report machine learning is on a bit of a tear right now, with advances that are infiltrating nearly every aspect of our lives. In the domain of materials science, this wave seems to be growing into a tsunami. Yet, there are still real hurdles that we face to maximize its benefit. This Matter of Opinion, crafted as a result of a workshop hosted by researchers at Sandia National Laboratories and attended by a cadre of luminaries, briefly summarizes our perspective on these barriers. By recognizing these problems in a community forum, we can share the burden of their resolution together with a common purpose and coordinated effort.

36 MATERIALS SCIENCE↗

A comparison of volumetric modulated arc therapy and sliding-window intensity-modulated radiotherapy in the treatment of Stage I-II nasal natural killer/T-cell lymphoma

This article is aimed to compare the dosimetric differences between volumetric modulated arc therapy (VMAT) and intensity-modulated radiotherapy (IMRT) for Stage I-II nasal natural killer/T-cell lymphoma (NNKTL). Ten patients with Stage I-II NNKTL treated with IMRT were replanned with VMAT (2 arcs). The prescribed dose of the planning target volume (PTV) was 50 Gy in 25 fractions. The VMAT plans with the Anisotropic Analytical Algorithm (Version 8.6.15) were based on an Eclipse treatment planning system; the monitor units (MUs) and treatment time (T) were scored to measure the expected treatment efficiency. All the 10 patients under the study were subject to comparisons regarding the quality of target coverage, the efficiency of delivery, and the exposure of normal adjacent organs at risk (OARs). The study shows that VMAT was associated with a better conformal index (CI) and homogeneity index (HI) (both p < 0.05) but slightly higher dose to OARs than IMRT. The MUs with VMAT (650.80 ± 24.59) were fewer than with IMRT (1300.10 ± 57.12) (relative reduction of 49.94%, p = 0.00) when using 2-Gy dose fractions. The treatment time with VMAT (3.20 ± 0.02 minutes) was shorter than with IMRT (7.38 ± 0.18 minutes) (relative reduction of 56.64%, p = 0.00). We found that VMAT and IMRT both provide satisfactory target dosimetric coverage and OARs sparing clinically. Likely to deliver a bit higher dose to OARs, VMAT in comparison with IMRT, is still a better choice for treatment of patients with Stage I-II NNKTL, thanks to better dose distribution, fewer MUs, and shorter delivery time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Machine learning-based discovery of molecular descriptors that control polymer gas permeation

While machine learning has found increasing use in predicting the properties of polymeric materials with only a knowledge of chain architecture, determining the molecular factors underpinning properties (“interpretable AI”) has remained less well explored. We show that encoding chain chemistry in commonly employed formats, e.g., binary-valued fingerprints, leads to uniqueness issues during the hashing process to save storage space. This is because the hashing algorithm can map several chemical moieties into the same bit. These issues carry over into the ML algorithms, especially for “inverse” design and interpretable AI, and cannot be avoided by changing the length of the fingerprint. Using MACCS key featurizations of monomer repeats resolves some of these issues, and we show that a few substructures consistently appear in top features for maximizing permeability across several gases and ML models. These are carbon–carbon double bonds (as in polyacetylenes) especially when they are associated with methyl groups (found in branching architectures). Here these results, derived from the limited data set of ~ 500 polymers with experimental gas permeation data, are in agreement with physical insight and thus provide a robust foundation which could further enable study of these material classes through detailed experiments and simulations.

36 MATERIALS SCIENCE↗

Measurement of Fission Neutron Spectrum and Multiplicity using a Gamma Tag Double Time-of-flight Setup

Recent efforts have been made to improve the prompt fission neutron spectrum and nu-bar measurements for Uranium and Plutonium isotopes particularly in the keV region. A system has been designed at Rensselaer Polytechnic Institute (RPI) utilizing an array of EJ-301 liquid scintillators as well as lithium glass and plastic scintillators to experimentally determine these values. An array of BaF2 detectors was recently obtained from Oak Ridge National Laboratory to be used in conjunction with the neutron detectors. The system uses a novel gamma tagging method for fission which can offer an improvement over conventional fission chambers due to increased sample mass. A coincidence requirement on the gamma detectors from prompt fission gammas is used as the fission tag for the system as opposed to fission fragments in a conventional fission chamber. The system utilizes pulse digitization using Acqiris 8 bit digitizer boards which allow for gamma/neutron pulse height discrimination on the liquid scintillators during post processing. Additionally, a 252Cf fission chamber was designed and constructed at RPI which allowed for optimization and testing of the system without the need for an external neutron source. The characteristics of the gamma tagging method such as false detection rate and detection efficiency were determined using this fission chamber and verified using MCNP Polimi modeling. Prompt fission neutron spectrum data has been taken using the fission chamber focusing on the minimum detectable neutron energy for each of the various detectors. Plastic scintillators were found to offer a significant improvement over traditional liquid scintillators allowing energy measurements down to 50 keV. Background was also characterized for all detectors and will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-high speed burst-mode imager for multi-frame radiography

A 720 x 720 pixel hybrid-CMOS imager was fabricated by Rockwell Scientific (now Teledyne Imaging Sensors). Several cameras have been in operation for 5 years, in a variety of static and dynamic experiments, at the 800MeV proton radiography (pRAD) facility at the LANSCE accelerator. The cameras can operate with a per-pulse adjustable inter-frame time of 250ns to 2s, and with an exposure/integration-time as short as 150 ns. Given the 800 ms total readout time, the imager can be externally synchronized to 0.1-to-5Hz, 50-ns wide proton beam pulses, and record 1000-frame radiographic movies of 5-to-30 minute duration. The effectiveness and dependence of the global electronic shutter on the pixelated Si photo-sensor bias voltage is discussed. The spatial resolution dependence of the full imaging system on various monolithic and structured scintillators is presented. We also present features of a new-generation 10-frame, 1024 x 1024 pixel, 50-ns exposure, 12-bit dynamic range imager, which is now in the design phase.

47 OTHER INSTRUMENTATION↗

A 15GSa/s, 1.5GHz bandwidth waveform digitizing ASIC

The PSEC4 custom integrated circuit was designed for the recording of fast waveforms for use in large-area time-of-flight detector systems. The ASIC has been fabricated using the IBM-8RF 0.13 micron CMOS process. On each of 6 analog channels, PSEC4 employs a switched capacitor array (SCA) 256 samples deep, a ramp-compare ADC with 10.5 bits of DC dynamic range, and a serial data readout with the capability of region-of-interest windowing to reduce dead time. The sampling rate can be adjusted between 4 and 15 Gigasamples/second [GSa/s] on all channels and is servo-controlled on-chip with a low-jitter delay-locked loop (DLL). The input signals are passively coupled on-chip with a -3 dB analog bandwidth of 1.5 GHz. The power consumption in quiescent sampling mode is less than 50 mW/chip; at a sustained trigger and readout rate of 50 kHz the chip draws 100 mW. After fixed-pattern pedestal subtraction, the uncorrected integral non-linearity is 0.15% over an 750 mV dynamic range. With a linearity correction, a full 1 V signal voltage range is available.The sampling timebase has a fixed-pattern non-linearity with an RMS of 13%, which can be corrected for precision waveform feature extraction and timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Q weak experimental apparatus

The Jefferson Lab Q weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was created for this experiment to meet the technical challenges presented by the smallest and most precise e → p asymmetry ever measured. Technical milestones were achieved at Jefferson Lab in target power, beam current, beam helicity reversal rate, polarimetry, detected rates, and control of helicity-correlated beam properties. The experiment employed 180 μA of 89% longitudinally polarized electrons whose helicity was reversed 960 times per second. The electrons were accelerated to 1.16 GeV and directed to a beamline with extensive instrumentation to measure helicity-correlated beam properties that can induce false asymmetries. Møller and Compton polarimetry were used to measure the electron beam polarization to better than 1%. The electron beam was incident on a 34.4 cm liquid hydrogen target. After passing through a triple collimator system, scattered electrons between 5.8° and 11.6° were bent in the toroidal magnetic field of a resistive copper-coil magnet. The electrons inside this acceptance were focused onto eight fused silica Cherenkov detectors arrayed symmetrically around the beam axis. A total scattered electron rate of about 7 GHz was incident on the detector array. The detectors were read out in integrating mode by custom-built low-noise pre-amplifiers and 18-bit sampling ADC modules. The momentum transfer Q 2 =0.025 GeV 2 was observed using dedicated low-current ( ~ 100 pA ) measurements with a set of drift chambers before (and a set of drift chambers and trigger scintillation counters after) the toroidal magnet

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterisation of the PXIE Allison-type emittance scanner

An Allison-type emittance scanner has been designed for PXIE at FNAL with the goal of providing fast and accurate phase space reconstruction. The device has been modified from previous LBNL/SNS designs to operate in both pulsed and DC modes with the addition of water-cooled front slits. Extensive calibration techniques and error analysis allowed confinement of uncertainty to the <5% level (with known caveats). With a 16-bit, 1 MHz electronics scheme the device is able to analyse a pulse with a resolution of 1 μs, allowing for analysis of neutralisation effects. As a result, this paper describes a detailed breakdown of the R&D, as well as post-run analysis techniques.

43 PARTICLE ACCELERATORS↗