Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beryllium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Pulsed laser deposition of epitaxial BeO thin films on sapphire and SrTiO{sub 3}

Epitaxial beryllia thin films were grown by pulsed laser deposition on Al{sub 2}O{sub 3}(001) and SrTiO{sub 3}(111) substrates. Nearly relaxed epitaxial films were obtained on both substrates at growth temperatures of up to about 600 °C. Crystalline films with expanded lattice parameters were obtained even at room temperature. The maximum growth temperature was limited by a loss of beryllium from the film surface. The volatility of beryllium appeared to be caused by the slow oxidation kinetics at the film surface and the re-sputtering effect of high-energy Be and BeO species in the ablation plume. Time-of-flight plume composition analysis suggested that the target surface became Be metal rich at low oxygen pressures, reducing the growth rate of beryllia films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First measurement of the 10B(α,n)13N reaction in an inertial confinement fusion implosion at the National Ignition Facility: Initial steps toward the development of a radiochemistry mix diagnostic

We report the first measurement of the 10B(α,n)13N reaction in a polar-direct-drive exploding pusher (PDXP) at the National Ignition Facility (NIF). This work is motivated by the need to develop alternative mix diagnostics, radiochemistry being the focus here. The target is composed of a 65/35 at. % deuterium–tritium (DT) fill surrounded by a roughly 30 μm thick beryllium ablator. The inner portion of the beryllium ablator is doped with 10 at. % of 10B. Radiation-hydrodynamics calculations were performed in 1D to optimize both the remaining boron rho-R and the DT neutron yield. A charged-particle transport post-processor has been developed to study α-induced reactions on the ablator material. Results indicate a large 13N production from α-induced reactions on 10B, measurable by the radiochemical analysis of a gaseous samples system at the NIF. The PDXP target N201115-001 was successfully fielded on the NIF, and nitrogen from the 10B(α,n)13N reaction was measured. The 13N production yield, as well as the DT neutron yield, was, however, lower than expected. Some of the reduced yields can be explained by the oblate shape, but the ratios of the various radiochemical signals are not commensurate with expectations based on a simple reduction of the 1D results. Preliminary 2D radiation-hydrodynamics computations are consistent with the experimental measurements, and work is ongoing to extend the radiochemistry analysis into higher dimensions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-Z linac targets for low-MV gold nanoparticle radiation therapy

Purpose: To investigate the potential of low-Z/low-MV (low-Z) linac targets for gold nanoparticle radiotherapy (GNPT) and to determine the microscopic dose enhancement ratio (DER) due to GNP for the alternative beamlines. In addition, to evaluate the degradation of dose enhancement arising from the increased attenuation of x rays and larger skin dose in water for the low-MV beams compared to the standard linac. Methods: Monte Carlo simulations were used to compute dose and DER for various flattening-filter-free beams (2.5, 4, 6.5 MV). Target materials were beryllium, diamond, and tungsten-copper high-Z target. Target thicknesses were selected based on 20%, 60%, 70%, and 80% of the continuous slowing down approximation electron ranges for a given target material and energy. Evaluation of the microscopic DER was carried out for 100 nm GNP including the degradation factors due to beam attenuation. Results: The greatest increase in DER compared to the standard 6.5 MV linac was for a 2.5 MV Be-target (factor of ∼2). Skin dose ranged from ∼10% (Be, 6.5 MV-80%) to ∼85% (Be, 2.5 MV-20%) depending on the target case. Attenuation of 2.5 MV beams at 22 cm was higher by ∼75% compared with the standard beam. Taking into account the attenuation at 22 cm depth, the effective dose enhancement was up to ∼60% above the DER of the high-Z target. For these cases the effective DER ranged between ∼1.6 and 6 compared with the standard linac. Conclusions: Low-Z (2.5 MV) GNPT is possible even after accounting for greater beam attenuation for deep-seated tumors (22 cm) and the increased skin dose. Further, it can lead to significant sparing of normal tissue while simultaneously escalating the dose in the tumor cells.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of inactive impurities on the burning of ICF targets

The efficiency of thermonuclear burning of the spherical deuterium-tritium (DT) plasma of inertial confinement fusion (ICF) targets in the presence of low-Z impurities (such as lithium, carbon, or beryllium) with arbitrary concentrations is investigated. The effect of impurities produced due to the mixing of the thermonuclear fuel with the material of the structural elements of the target during its compression on the process of target burning is studied, and the possibility of using solid noncryogenic thermonuclear fuels in ICF targets is analyzed. Analytical dependences of the ignition energy and target thermonuclear gain on the impurity concentration are obtained. The models are constructed for homogeneous and inhomogeneous plasmas for the case in which the burning is initiated in the central heated region of the target and then propagates into the surrounding relatively cold fuel. Two possible configurations of an inhomogeneous plasma, namely, an isobaric configuration formed in the case of spark ignition of the target and an isochoric configuration formed in the case of fast ignition, are considered. The results of numerical simulations of the burning of the DT plasma of ICF targets in a wide range of impurity concentrations are presented. The simulations were performed using the TEPA one-dimensional code, in which the thermonuclear burning kinetics is calculated by the Monte Carlo method. It is shown that the strongest negative effect related to the presence of impurities is an increase in the energy of target ignition. It is substantiated that the most promising solid noncryogenic fuel is DT hydride of beryllium (BeDT). The requirements to the plasma parameters at which BeDT can be used as a fuel in noncryogenic ICF targets are determined. Variants of using noncryogenic targets with a solid thermonuclear fuel are proposed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Source term evaluation for accident transients in the experimental fusion facility ITER

We have studied the transport and chemical speciation of radio-toxic and toxic species for an event of water ingress in the vacuum vessel of experimental fusion facility ITER with the ASTEC code. In particular our evaluation takes into account an assessed thermodynamic data for the beryllium gaseous species. This study shows that deposited beryllium dusts of atomic Be and Be(OH){sub 2} are formed. It also shows that Be(OT){sub 2} could exist in some conditions in the drain tank. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Final Report on ITER Task Agreement 81-08

As part of an ITER Implementing Task Agreement (ITA) between the ITER US Participant Team (PT) and the ITER International Team (IT), the INL Fusion Safety Program was tasked to provide the ITER IT with upgrades to the fusion version of the MELCOR 1.8.5 code including a beryllium dust oxidation model. The purpose of this model is to allow the ITER IT to investigate hydrogen production from beryllium dust layers on hot surfaces inside the ITER vacuum vessel (VV) during in-vessel loss-of-cooling accidents (LOCAs). Also included in the ITER ITA was a task to construct a RELAP5/ATHENA model of the ITER divertor cooling loop to model the draining of the loop during a large ex-vessel pipe break followed by an in-vessel divertor break and compare the results to a simular MELCOR model developed by the ITER IT. This report, which is the final report for this agreement, documents the completion of the work scope under this ITER TA, designated as TA 81-08.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reactivity Accountability Attributed to Reflector Poisons in the High Flux Isotope Reactor

The objective of this study is to develop a methodology to predict the reactivity impact as a function of outage time between cycles of 3He, 6Li, and other poisons in the High Flux Isotope Reactor s (HFIR) beryllium reflector. The reactivity worth at startup of the HFIR has been incorrectly predicted in the past after the reactor has been shut-down for long periods of time. The incorrect prediction was postulated to be due to the erroneous calculation of 3He buildup in the beryllium reflector. It is necessary to develop a better estimate of the start-of-cycle symmetric critical control element positions since if the estimated and actual symmetrical critical control element positions differ by more than $1.55 in reactivity (approximately one-half inch in control element startup position), HFIR is to be shutdown and a technical evaluation is performed to resolve the discrepancy prior to restart. 3He is generated and depleted during operation, but during an outage, the depletion of 3He ceases because it is a stable isotope. 3He is born from the radioactive decay of tritium, and thus the concentration of 3He increases during shutdown. SCALE, specifically the TRITON and CSAS5 control modules including the KENO V.A, COUPLE, and ORIGEN functional modules were utilized in this study. An equation relating the down time (td) to the change in symmetric control element position was generated and validated against measurements for approximately 40 HFIR operating cycles. The newly-derived correlation was shown to improve accuracy of predictions for long periods of down time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimizing Normal Tissue Sparing in Ion Therapy Using Calculated Isoeffective Dose for Ion Selection

Purpose: To investigate how the selection of ion type affects the calculated isoeffective dose to the surrounding normal tissue as a function of both normal tissue and target tissue {alpha}/{beta} ratios. Methods and Materials: A microdosimetric biologic dose model was incorporated into a Geant4 simulation of parallel opposed beams of protons, helium, lithium, beryllium, carbon, and neon ions. The beams were constructed to give a homogeneous isoeffective dose to a volume in the center of a water phantom for target tissues covering a range of cobalt equivalent {alpha}/{beta} ratios of 1-20 Gy. Concomitant normal tissue isoeffective doses in the plateau of the ion beam were then compared for different ions across the range of normal tissue and target tissue radiosensitivities for a fixed isoeffective dose to the target tissue. Results: The ion type yielding the optimal normal tissue sparing was highly dependent on the {alpha}/{beta} ratio of both the normal and the target tissue. For carbon ions, the calculated isoeffective dose to normal tissue at a 5-cm depth varied by almost a factor of 5, depending on the {alpha}/{beta} ratios of the normal and target tissue. This ranges from a factor of 2 less than the isoeffective dose of a similar proton treatment to a factor of 2 greater. Conclusions: No single ion is optimal for all treatment scenarios. The heavier ions are superior in cases in which the {alpha}/{beta} ratio of the target tissue is low and the {alpha}/{beta} ratio of normal tissue is high, and protons are superior in the opposite circumstances. Lithium and beryllium appear to offer dose advantages similar to carbon, with a considerably lower normal tissue dose when the {alpha}/{beta} ratio in the target tissue is high and the {alpha}/{beta} ratio in the normal tissue is low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fabrication and evaluation of variable focus X-ray lenses.

We report on the fabrication, preliminary metrology, and X-ray transmission results of variable-focus cylindrical beryllium lenses. Each lens consists of a number of 1-mm-diameter lenslets made by precision computer numerical control (CNC) drilling into a beryllium substrate. The substrate is then cut into five parts, each having a different number of lenslets, ranging from 10 to 50. Each lens is then cut diagonally, using an electron discharge machine, to provide it with focusing ability. Unlike the traditional lenses having a fixed focal distance for a given energy, the present lenses provide for a wide range of photon energies and focal distances. Additionally, X-ray transmission through the lens is enhanced by reducing lenslet wall thickness to about 50 {micro}m, the thinnest reported to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct experimental constraints on the spatial extent of a neutrino wavepacket

Despite their high relative abundance in our Universe, neutrinos are the least understood fundamental particles of nature. In fact, the quantum properties of neutrinos emitted in experimentally relevant sources are theoretically contested and the spatial extent of the neutrino wavepacket is only loosely constrained by reactor neutrino oscillation data with a spread of 13 orders of magnitude. Here we present a method to directly access this quantity by precisely measuring the energy width of the recoil daughter nucleus emitted in the radioactive decay of beryllium-7. The final state in the decay process contains a recoiling lithium-7 nucleus, which is entangled with an electron neutrino at creation. The lithium-7 energy spectrum is measured to high precision by directly embedding beryllium-7 radioisotopes into a high-resolution superconducting tunnel junction that is operated as a cryogenic sensor. Under this approach, we set a lower limit on the Heisenberg spatial uncertainty of the recoil daughter of 6.2 pm, which implies that the final-state system is localized at a scale more than a thousand times larger than the nucleus itself. From this measurement, the first, to our knowledge, direct lower limit on the spatial extent of a neutrino wavepacket is extracted. These results may have implications in several areas including the theoretical understanding of neutrino properties, the nature of localization in weak nuclear decays and the interpretation of neutrino physics data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiation Shielding Options for the Affordable Fission Surface Power System

The Affordable Fission Surface Power System (AFSPS) is a proposed power source for an outpost capable of housing six humans for up to six weeks on the lunar surface and emphasizes the design principles of low risk and affordability over high performance. The radiation shield is the most massive component of the reactor system and its effect on launch mass greatly affects the affordability of the AFSPS. Potential shielding materials include lithium hydride, enriched boron-10 carbide, water, borated water, beryllium, boron-doped beryllium and zirconium hydride. Zirconium hydride is the most effective neutron attenuator and also significantly attenuates gamma radiation, but at a significant mass penalty. The other neutron attenuating materials all require the addition of a tungsten layer to provide significant gamma attenuation. Based on neutron radiation alone, lithium hydride is the lightest of the potential attenuators, followed by water and borated water. When gamma radiation is also considered, the lithium hydride/tungsten shield is shown to be the lightest composite shield with a combined mass of 3246 kg, followed by the borated water/tungsten shield (3479 kg). The boron carbide/tungsten shield has a total mass of 4129 kg, but represents significantly less development risk.

36 MATERIALS SCIENCE↗

High-pressure and high-temperature x-ray diffraction cell for combined pressure, composition, and temperature measurements of hydrides

We present the design and construction of a high-pressure (200 bars) and high-temperature (600 deg. C) x-ray diffraction (XRD) cell for the in situ investigation of the hydrogen sorption of hydrides. In combination with a pressure, composition, and temperature system, simultaneous XRD and volumetric measurements become accessible. The cell consists of an x-ray semi-transparent hemispherical beryllium (Be) dome covering a heatable sample stage, which simultaneously allows sample temperatures of up to 600 deg. C in an applied hydrogen atmosphere of up to 200 bars. The system volume is as low as possible to maximize the precision of the volumetric measurements. Due to the high thermal conductivity of hydrogen, and in order to preserve the mechanical stability of the beryllium, the cell is water cooled. Its operability was studied on the example of the hydrogen absorption of Mg{sub 2}Ni. The advantages and limitations of the proposed design are discussed.

42 ENGINEERING↗

Novel cell design for combined in situ acoustic emission and x-ray diffraction study during electrochemical cycling of batteries

An in situ acoustic emission (AE) and x-ray diffraction cell for use in the study of battery electrode materials has been designed and tested. This cell uses commercially available coin cell hardware retrofitted with a metalized polyethylene terephthalate (PET) disk, which acts as both an x-ray window and a current collector. In this manner, the use of beryllium and its associated cost and hazards is avoided. An AE sensor may be affixed to the cell face opposite the PET window in order to monitor degradation effects, such as particle fracture, during cell cycling. Silicon particles, which were previously studied by the AE technique, were tested in this cell as a model material. The performance of these cells compared well with unmodified coin cells, while providing information about structural changes in the active material as the cell is repeatedly charged and discharged.

36 MATERIALS SCIENCE↗

Tritium plasma experiment: Parameters and potentials for fusion plasma-wall interaction studies

The tritium plasma experiment (TPE) is a unique facility devoted to experiments on the behavior of deuterium/tritium in toxic (e.g., beryllium) and radioactive materials for fusion plasma-wall interaction studies. A Langmuir probe was added to the system to characterize the plasma conditions in TPE. With this new diagnostic, we found the achievable electron temperature ranged from 5.0 to 10.0 eV, the electron density varied from 5.0 x 10{sup 16} to 2.5 x 10{sup 18} m{sup -3}, and the ion flux density varied between 5.0 x 10{sup 20} to 2.5 x 10{sup 22} m{sup -2} s{sup -1} along the centerline of the plasma. A comparison of these plasma parameters with the conditions expected for the plasma facing components (PFCs) in ITER shows that TPE is capable of achieving most ({approx}800 m{sup 2} of 850 m{sup 2} total PFCs area) of the expected ion flux density and electron density conditions.

36 MATERIALS SCIENCE↗

Simultaneous imaging/reflectivity measurements to assess diagnostic mirror cleaning

Practical methods to clean ITER's diagnostic mirrors and restore reflectivity will be critical to ITER's plasma operations. We describe a technique to assess the efficacy of mirror cleaning techniques and detect any damage to the mirror surface. The method combines microscopic imaging and reflectivity measurements in the red, green, and blue spectral regions and at selected wavelengths. The method has been applied to laser cleaning of single crystal molybdenum mirrors coated with either carbon or beryllium films 150-420 nm thick. It is suitable for hazardous materials such as beryllium as the mirrors remain sealed in a vacuum chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of graphite properties in thermal analysis of CHTR: A parametric study

Compact High Temperature Reactor (CHTR) is a {sup 233}U-Thorium fuelled, lead-bismuth cooled reactor. The CHTR core mainly consists of graphite and beryllium oxide (BeO). The CHTR core consists of nineteen prismatic beryllium oxide (BeO) moderator blocks. These 19 blocks contain centrally located graphite fuel tubes. The BeO moderator blocks are surrounded by reflector blocks (partially graphite and partially BeO). The nuclear heat from the core is removed passively by natural circulation of the coolant between top and bottom plenums, upward through the fuel tubes and returning through the downcomer tubes at the periphery. The temperature gradient in fuel tubes, downcomer tubes and BeO is very high and therefore, to take care of the differential thermal expansion, gaps are provided in the core between the tubes and other core components. These gaps affect the heat transfer through the core in radial direction. In addition, there is a large variation in thermal properties of graphite which in turn affects the thermal behaviour of the core in various operating conditions. The fuel of CHTR is TRISO coated particle fuel. These particles are packed in with graphite powder as matrix and made into cylindrical compacts these compacts are packed in the bores of fuel tube. In this study, the effect of the thermal conductivity variation of the graphite on the temperature distribution of the core and density variation of the matrix graphite material in fuel compact on the maximum fuel kernel temperature is studied along with the overall role of graphite properties variation in heat transfer.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Self-similar expansion of a warm dense plasma

The properties of an expanding plasma composed of degenerate electron fluid and non-degenerate ions are studied. For our purposes, we use fluid equations for ions together with the electron momentum equation that include quantum forces (e.g., the quantum statistical pressure, forces due to the electron-exchange and electron correlations effects) and the quasi-neutrality condition. The governing equation is written in a tractable form by using a self-similar transformation. Numerical results for typical beryllium plasma parameters revealed that, during the expansion, the ion acoustic speed decreases for both isothermal and adiabatic ion pressure. When compared with classical hydrodynamic plasma expansion model, the electrons and ions are found to initially escape faster in vacuum creating thus an intense electric field that accelerates most of the particles into the vacuum ahead of the plasma expansion. The relevancy of the present model to beryllium plasma produced by a femto-second laser is highlighted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel solution to the gated x-ray detector gain droop problem

Microchannel plate (MCP), microstrip transmission line based, gated x-ray detectors used at the premier ICF laser facilities have a drop in gain as a function of mircostrip length that can be greater than 50% over 40 mm. These losses are due to ohmic losses in a microstrip coating that is less than the optimum electrical skin depth. The electrical skin depth for a copper transmission line at 3 GHz is 1.2 μm while the standard microstrip coating thickness is roughly half a single skin depth. Simply increasing the copper coating thickness would begin filling the MCP pores and limit the number of secondary electrons created in the MCP. The current coating thickness represents a compromise between gain and ohmic loss. We suggest a novel solution to the loss problem by overcoating the copper transmission line with five electrical skin depths (∼6 μm) of Beryllium. Beryllium is reasonably transparent to x-rays above 800 eV and would improve the carrier current on the transmission line. The net result should be an optically flat photocathode response with almost no measurable loss in voltage along the transmission line.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗