Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “all electric”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Fabrication and Performance Evaluation of Double-Sided Copper Nanowire Arrays as Thermal and Electrical Interfacial Layers

Reducing contact interface thermal and electrical resistances is in great demand across various industries, particularly in the semiconductor industry. This study introduces an approach using double-sided copper nanowire (Cu NW) arrays on copper sheets as both thermal and electrical interfacial layers, designed to effectively accommodate the topographical inconsistencies between contact surfaces. Further, experimental outcomes reveal a significant reduction in thermal contact resistance (TCR), with a value of 2.5 mm 2 K W –1 , thereby exceeding the efficiency of reported nanostructural thermal interface materials (TIMs). Additionally, when utilized as an electrical interfacial layer, these double-sided Cu NWs arrays dramatically reduced electrical contact resistance (ECR), outperforming traditional conductive grease in applications necessitating separable bonding, though showing comparable performance to costly silver-based conductive epoxies required for permanent, inseparable bonds. The promising results of the double-sided Cu NWs arrays in reducing both TCR and ECR, confirmed by finite element simulation, highlight their substantial potential in advancing TIMs and electrical interconnection applications across various sectors.

42 ENGINEERING↗

Electrical Conductivity and Sound Velocities of Talc Under High Pressure and High Temperature Conditions and Application to the Subducting Cocos Plate

Talc is expected to be an important water carrier in Earth's upper mantle, and understanding its electrical and seismic properties under high pressure and temperature conditions is required to detect possible talc-rich regions in subduction zones imaged using geophysical observations. Here, we conducted acoustic and electrical experiments on natural talc aggregates at relevant pressure-temperature conditions. Compressional wave velocity (V p ) was measured using ultrasonic interferometry in a Paris-Edinburgh press at pressures up to 3.4 GPa and temperatures up to 873 K. Similar Vp values are obtained regardless of the initial crystallographic preferred orientation of the samples, which can be explained by talc grain reorientation during the experiment, with the (001) plane becoming perpendicular to the uniaxial compression axis. Electrical conductivity of the same starting material was determined using impedance spectroscopy in a multi-anvil press up to 6 GPa and 1263 K. Two conductivity jumps are observed, at ∼860–1025 K and ∼940–1080 K, depending on pressure, and interpreted as talc dehydroxylation and decomposition, respectively. Electrical anisotropy is observed at low temperature and decreases with increasing pressure (∼10 at 1.5 GPa and ∼2 at 3.5 GPa). Comparison of acoustic and electrical results with geophysical observations in central Mexico supports the presence of a talc-bearing layer atop the subducted Cocos plate.

Cocos plate↗

Bounding the costs of electric vehicle managed charging—supply curves for scenarios from 2025 to 2050

As electric vehicle (EV) adoption increases, the resulting EV battery charging will increase demand on the electric power grid. Through EV managed charging (EVMC) programs, charging can be shifted in time to support electric grid reliability and reduce electricity costs. EVMC can offer an alternative to additional supply-side generation, but the costs of EVMC implementation must be understood to evaluate the cost-benefits of EVMC. This paper presents bottom-up, forward-looking (from 2025 through 2050) estimates of the incremental costs associated with different EVMC dispatch mechanisms available to electric utilities. The costs of enabling EVMC for a range of customer participation levels are presented in the form of supply curves, which provide per-EV costs for a targeted level of participation. The largest drivers of cost variation are assumptions about future charging flexibility paradigms described in four scenarios. These supply curves can be used to quantify the expected costs of EVMC programs and enable comparison with supply-side or other demand flexibility alternatives.

25 ENERGY STORAGE↗

Pumped Thermal Electricity Storage with Supercritical CO2 Cycles and Solar Heat Input

Pumped Thermal Electricity Storage (PTES) is an energy storage device that uses grid electricity to drive a heat pump that generates hot and cold storage reservoirs. This thermal potential is later used to power a heat engine and return electricity to the grid. In this article, a PTES variant that uses supercritical carbon dioxide (sCO2) as the working fluid is introduced. sCO2-PTES cycles have higher work ratios and power densities than the systems based on ideal gases that have been investigated to date. Furthermore, sCO2- PTES cycles may achieve higher round-trip efficiencies for a given hot storage temperature (up to 78% at 560°C). The sensitivity of PTES cycles to loss factors such as isentropic efficiencies and temperature differences between the power cycle and storage fluid is investigated. A second concept whereby an sCO2- PTES cycle is integrated with concentrating solar power (CSP) is introduced. This concept ‘time-shifts’ the recompression of an sCO2 recompression cycle to a period of lower electricity prices and stores the heat. When solar heat is dispatched, the recompressor may be avoided as the required heat is obtained from storage, thereby leading to increased heat engine efficiencies. The net work output of this integrated system is 10-18% greater than the conventional recompression cycle. Combining PTES with a CSP power cycle is therefore shown to improve the dispatch of solar heat as well as providing electricity storage services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Interacting dust grains in complex plasmas: Ion wake formation and the electric potential

Dust grains have been used as minimally invasive probes to determine plasma parameters including the plasma density, temperature, and electric field in a plasma discharge. However, the dust grains in a plasma generate local potential disturbances due to the collection of charge and the subsequent electrostatic interactions between the dust and charged plasma particles. Dust grains in close proximity to one another exhibit interesting non-reciprocal interactions and self-organize into structures such as one-dimensional filamentary chains, two-dimensional “zigzags,” and three-dimensional helices, among others. The formation of these structures suggests that although the dust grains may be less invasive than traditional plasma probes, the disturbance to the local plasma environment introduced by dust grains is non-trivial. Commonly used analytic forms of the electric potential describing complex plasmas have failed to resolve the near-dust region, and as a result are insufficient to provide insight about the formation of complex dust structures. Here, we use an N-body simulation to compute the electric potential from ion densities near various dust grain configurations. We provide an alternative description to the standard analytic model for the electric potential of dust and ion wakes based on a Gaussian shaped cloud of ions. The electric potential obtained from simulations is used to identify minimum energy configurations for two and three dust grains. It is further demonstrated that the minimum potential region identified for N dust grains and their associated ion wakes does not predict the minimum-energy configuration of N + 1 dust grains.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electric fields imbue enzyme reactivity by aligning active site fragment orbitals

It is broadly recognized that intramolecular electric fields, produced by the protein scaffold and acting on the active site, facilitate enzymatic catalysis. This field effect can be described by several theoretical models, each of which is intuitive to varying degrees. In this contribution, we show that a fundamental effect of electric fields is to generate electrostatic potentials that facilitate the energetic alignment of reactant frontier orbitals. We apply this model to demystify the impact of electric fields on high-valent iron–oxo heme proteins: catalases, peroxidases, and peroxygenases/monooxygenases. Specifically, we show that this model easily accounts for the observed field-induced changes to the spin distribution within peroxidase active sites and explains the transition between epoxidation and hydroxylation pathways seen in Cytochrome P450 active site models. Thus, for the intuitive interpretation of the chemical effect of the field, the strategy involves analyzing the response of the orbitals of active site fragments, and their energetic alignment. We note that the energy difference between fragment orbitals involved in charge redistribution acts as a measure for the chemical hardness/softness of the reactive complex. This measure, and its sensitivity to electric fields, offers a single parameter model from which to quantitatively assess the effects of electric fields on reactivity and selectivity. Thus, the model provides an additional perspective to describe electrostatic preorganization and offers ways for its manipulation.

59 BASIC BIOLOGICAL SCIENCES↗

Tuning water dissociation at oxide–electrolyte interfaces with electric fields

Understanding how electric fields influence water dissociation at heterogeneous interfaces is crucial for controlling interfacial chemical reactions and advancing next-generation energy technologies. Herein, ab initio–based machine learning simulations show that even small electric field changes can significantly alter the water dissociation fraction at planar TiO 2 –electrolyte interfaces. The resulting free energy difference between undissociated and dissociated interfacial water exhibits a linear dependence on the field change with a slope of 1.97 eÅ, which far exceeds the dissociation-induced dipole change of a water molecule. Employing a machine-learned collective variable to investigate the reaction statistics of thousands of water dissociation/recombination events, we find that small electric field changes exert minor effects on individual reaction energy barriers but significantly influence the populations of local configurations associated with initial states that are most favorable for reactions. These findings elucidate the pronounced impact of electric fields on interfacial water dissociation and reveal a mechanism for electric-field-controlled chemical reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatio-temporal electric field distributions in an atmospheric plasma jet impinging on a microchannel array surface

The electric field distribution in the ionization waves (IWs) propagating over a microchannel array dielectric surface, with the channels either empty or filled with distilled water, is measured by ps electric field induced second harmonic generation. The surface IW is initiated by the atmospheric pressure N 2 –Ar plasma jet impinging on the surface vertically and powered by ns pulse discharge bursts. The results show that the electric field inside the microchannels, specifically its horizontal component, is enhanced by up to a factor of 2. The field enhancement region is localized within the channels. The vertical electric field inside the channels lags in time compared to the field measured at the ridges, indicating the transient reversal of the IW propagation direction across the channels (toward the jet). This is consistent with the phase-locked plasma emission images and confirmed by the kinetic modeling predictions, which show that the IW ‘jumps’ over the empty channels and propagates into the channels only after the jump between the adjacent ridges. When the channels are filled with water, the wave speed increases by up to 50%, due to the higher effective dielectric constant of the surface. No evidence of a significant electric field enhancement near the dielectric surface (ceramic or water) has been detected, within the spatial resolution of the present diagnostic, ~100 μ m.

plasmas and liquids↗

Climate-aware decision-making: lessons for electric grid infrastructure planning and operations

Abstract Climate change poses significant risks to large-scale infrastructure systems and brings considerable uncertainties that challenge historical planning approaches. Here we focus on how climate awareness might be better incorporated into planning and decision-making in the electric power sector. To do so, we consider lessons from decision science literature where researchers have specifically focused on how to make better decisions under uncertainty. We perform a three-part review: of decision science literature on best practices for decision-making under uncertainty, of industry practice documents to understand how new uncertainties may affect the types of decisions electric utilities are making today, and of literature on electricity sector planning under climate change to assess how lessons from decision science might fit into sector-specific analyses. We discuss how characterizations of uncertainty from the decision science literature might guide approaches in the electricity sector to appropriately capture climate-related uncertainties. We also distill three key ideas from the decision science literature that can be incorporated into electricity sector planning to manage these new uncertainties: robustness, adaptive planning, and multi-stakeholder engagement. We offer example recommendations for how these key ideas might be incorporated into one essential type of planning activity, capacity expansion.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-Economic Implications of Electrical Machine Scaling for Wave Energy Converters

The sizing of an electrical machine for a Wave Energy Converter (WEC) can have a substantial impact on the overall sizing, cost, and rating of the device. An electrical generator is typically part of the power take-off system, which is the mechanism by which the energy absorbed by the prime mover is transformed into usable electrical energy. For practically all WECs, the rate of change of actuation is predominantly determined by the wave resource (i.e., the wave height and frequency), and devices will see a sinusoidal varying velocity according to the wave conditions. The same can then be said for both directly and indirectly coupled power take-offs with electrical generators. This techno-economic study investigates electrical machine scaling and associated cost implications through core machine design theory, manufacturer data, supporting literature, and the Reference Model Project sponsored by the U.S. Department of Energy. The Reference Model Project was a partnered effort to develop open-source marine energy point designs as reference models to benchmark marine energy technology performance and costs, methods for design and analysis of marine energy technologies, estimations for capital costs, operational costs, and levelized cost of energy. The results from this study show torque is directly related to (1) the physical size of the machine required to increase the air-gap sheer stresses, (2)the amount of active material, (3) the support structure, (4) bearing size and rating, and (5) offshore cable rating, all of which have a significant effect on overall system costs in terms of both capital and operational expenditures. This paper aims to be a critical benchmark in helping determine an "optimal" nameplate rating for wave energy devices and their associated power take-offs. With an optimized rating and sizing process, WEC costs can be reduced and overall performance can be improved.

cables↗

A Machine Learning Framework to Deconstruct the Primary Drivers for Electricity Market Price Events

As the electricity grid is moving towards a 100% Renewable Energy Source Bulk Power Grid, the overall operations of the power system operations and electricity markets are changing. The electricity markets are not only dispatching resources economically but also taking into account various controllable actions like renewable curtailment, transmission congestion mitigation, and energy storage optimization to make sure the grid is operating reliably. As a result, price formations in electricity markets have become quite complex. Traditional root cause analysis and statistical approaches are rendered inapplicable to analyze and infer the main drivers behind price formation in the modern grid and markets with variable renewable energy (VRE). In this paper, we propose a machine learning analysis framework to deconstruct some primary drivers for price formation in modern electricity markets with high renewable energy and the outcomes can be utilized for various critical aspects of market design, renewable dispatch and curtailment, operations, and cyber-security applications. The framework can be applied to any ISO or market data and in this paper it is applied to open-source publicly available datasets from California Independent System Operator (CAISO) and ISO New England.

machine learning (ML), electricity markets, Renewa↗

Trends and Heterogeneity in Electric Vehicle Economics: A French Case Study

The total cost of ownership of electric vehicles depends on both the behavior and economic context of the driver as well as the level of government support offered for electrified vehicles. In this work, we study both of these effects as they shift private vehicle costs and emissions benefits, focused on a case study of the faculty and staff commuters to the Cite Scientifique campus of the University of Lille. The modeling approach considers the net costs and emissions from switching each driver from an internal combustion engine vehicle to three electrified options: a hybrid electric, a plug-in hybrid, and a pure battery electric. Increasing government support or technology-induced cost declines of electric vehicles both improve the economics of electrified options and shift more drivers towards battery electrics as the preferred alternative to thermal vehicles.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

A Power Take-Off (PTO) for Wave Energy Converters Based on the Hybrid Hydraulic-Electric Architecture (HHEA)

Wave energy is a promising renewable energy resource for coastal regions around the world, but is not yet an economically competitive source of electricity. More effective power take-off (PTO) designs would help to make wave power a feasible and clean source of energy. To do this, PTOs need to: i) enable controlled actuation, ii) convert absorbed energy into electricity efficiently, and iii) have minimal manufacturing costs. We propose a new PTO architecture that can exert arbitrary control loads on the WEC to maximize energy capture, enabling the downsizing of expensive electrical components while maintaining high efficiency. Our PTO design is based upon a hybrid hydraulic-electric architecture (HHEA). This paper compares the performance of the HHEA PTO against two other PTO designs: 1) a baseline PTO consisting of a system of rectifying check valves and accumulators, and 2) a PTO consisting of an electro-hydraulic actuator (EHA). The HHEA PTO is shown to produce much more power than the check valve PTO and the EHA PTO. Also, the required electric generator sizes for the HHEA are smaller than that of the EHA PTO. The reduced size of these components allows for a WEC which is less expensive to manufacture.

16 TIDAL AND WAVE POWER↗

Effect of Soluble Corrosion Products on Electrical Double Layer in LiCl-KCl Molten Salts

Corrosion in molten salts greatly hampers the application for renewable energy applications like molten salt reactors. To develop effective strategies for corrosion mitigation, understanding the interfacial structures and properties such as specific ion adsorption and electrical double layer capacitance are crucial. Using cyclic voltammetry and electrochemical impedance spectroscopy, we systematically studied the interfaces on various model electrodes including W (solid), Bi (liquid), and the stainless steel 316 in LiCl-KCl eutectic molten salts with the addition of corrosion species CrCl 2 and FeCl 2 . Both Cr 2+ and Fe 2+ ions increased electrical double layer capacitance, with Cr 2+ showing specific adsorption behavior and shifting the potential of zero charge, while Fe 2+ had minimal effect on point of zero charge. Two-working electrode measurements revealed increasing open-circuit potential and electrical double layer capacitance during the exposure of stainless steel 316, indicating its progressive corrosion and ion accumulation at the interface. X-ray photoelectron spectroscopy and Raman confirmed Cr enrichment at the interface. This work highlights the strong correlation between electrical double layer behavior and corrosion dynamics in molten salts and suggests electrical double layer capacitance as a sensitive, in situ indicator for corrosion monitoring.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Pilot Heavy-Duty Electric Vehicle Deployment for Anchorage, Alaska, Municipal Solid Waste Collection

Through a grant awarded by the U.S. Department of Energy, the Municipality of Anchorage initiated a pilot program in their Solid Waste Services (SWS) department to add heavy-duty electric trucks to its vehicle fleet. The project involves the purchase and deployment of a Peterbilt 220EV electric box truck and two Peterbilt 520EV heavy-duty electric refuse trucks. The Alaska Center for Energy and Power at the University of Alaska Fairbanks performed data analysis. Data collected include telemetry data from both types of electric trucks, charging data from the 520EV telemetry data and a Level 2 charger, and facility-level electric use data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilot Heavy-Duty Electric Vehicle Deployment for Anchorage, Alaska, Municipal Solid Waste Collection

Through a grant awarded by the U.S. Department of Energy, the Municipality of Anchorage initiated a pilot program in their Solid Waste Services (SWS) department to add heavy-duty electric trucks to its vehicle fleet. The project involves the purchase and deployment of a Peterbilt 220EV electric box truck and two Peterbilt 520EV heavy-duty electric refuse trucks. The Alaska Center for Energy and Power at the University of Alaska Fairbanks performed data analysis. Data collected include telemetry data from both types of electric trucks, charging data from the 520EV telemetry data and a Level 2 charger, and facility-level electric use data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Integrated Energy Systems Prototype Human-System Interface for a Steam Extraction Loop System to Support Joint Electricity-Hydrogen Flexible Operations

Due to increasing economic competition from renewables and combined-cycle natural gas plants, nuclear power plants are looking toward flexible operations to enhance their cost competitiveness. The Integrated Energy Systems project under the Light Water Reactor Sustainability program of the U.S. Department of Energy focuses on joint electricity-hydrogen flexible operations. Joint electricity-hydrogen flexible operations entail the nuclear power plant diverting thermal energy via main steam to a hydrogen production plant located nearby. The steam serves to enhance the efficiency of the hydrogen production. Furthermore, high temperature electrolysis requires a large amount of electricity, which the plant can also provide. The plant provides steam and electricity to the hydrogen plant throughout the day, but during peak demand hours the nuclear power plant returns to solely providing electricity to meet the high demand. Through this flexible concept of operations, the plant can optimize the thermal energy it produces without having to maneuver the power of the plant. This report documents the human factors process to design and develop a prototype human-system interface for the steam extraction loop that serves as the conduit between the nuclear power plant and the adjacent hydrogen plant. The design process followed the human factors guidelines set by NUREG-0711, Human Factors Engineering Program Review Model (O’Hara, Higgins, & Fleger, 2012), and expanded upon by the Guideline for Operational Nuclear Usability and Knowledge Elicitation (GONUKE; Boring, Ulrich, Joe, & Lew, 2015; Boring, Lew, & Ulrich, 2016). The design process entailed operator interviews to determine the concept of operations for the steam extraction loop, a review and adaptation of digital interface design concepts developed by the team in prior projects, an iterative design process, and reviews conducted by both operators and human factors experts. Several versions of the prototype human-system interface were developed. Operators were interviewed to determine what design features they found useful and would like to see in the interface. The design underwent a review by human factors experts against NUREG-0700, Human Interface Design Review Guidelines (U.S. Nuclear Regulatory Commission, 2019), to ensure compliance with the latest human factors standards for digital interfaces in nuclear applications. The design was then prototyped as a functional windows-based application integrated with the Generic Pressurized Water Reactor simulator modified to include the steam extraction loop. The simulation is supported by the Human Systems Simulation Laboratory at Idaho National Laboratory, which supports operator-in-the-loop testing. This is an ongoing project and the next phase of the project entails performing an operator-in-the-loop usability study to evaluate the interface and examine the proposed concept of operations to extraction steam from the nuclear power plant for delivery to the coupled hydrogen production plant.

99 GENERAL AND MISCELLANEOUS↗

Breakdown of Electric Vehicle Supply Equipment Installation Costs

The plug-in electric vehicles (PEVs) market is receiving help from the current political climate, incentives at the federal and state levels, excessive cost of petroleum fuel, growing focus on climate solutions, increasing investment and direction by automobile manufacturers and increased awareness through media reports and advertising. Increasingly, the transportation industry, in both the United States and many other countries, is aimed at electric motive energy where practical. Increased investment in research and development have led to increasing vehicle range and lower battery costs; both of which have been deterrents in the past. The increasing demand for PEVs (consisting of the battery electric vehicle [BEV] and plug-in hybrid electric vehicle [PHEV], is challenged by the need for charging infrastructure to support these vehicles. The BEV relies totally on the on-board battery to supply the motive energy while the PHEV utilizes its battery and an installed internal combustion engine (ICE). The maximum benefit is achieved by using the battery power as much as possible. This arrangement requires the use of battery charging equipment, known as electric vehicle supply equipment (EVSE).

33 ADVANCED PROPULSION SYSTEMS↗