Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X-Ray diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Optical Analysis of an Ultra-High resolution Two-Mirror Soft X-Ray Microscope

This work has summarized for a Schwarzschild microscope some relationships between numerical aperture (NA), magnification, diameter of the primary mirror, radius of curvature of the secondary mirror, and the total length of the microscope. To achieve resolutions better than a spherical Schwarzschild microscope of 3.3 Lambda for a perfectly aligned and fabricated system. it is necessary to use aspherical surfaces to control higher-order aberrations. For an NA of 0.35, the aspherical Head microscope provides diffraction limited resolution of 1.4 Lambda where the aspherical surfaces differ from the best fit spherical surface by approximately 1 micrometer. However, the angle of incidence varies significantly over the primary and the secondary mirrors, which will require graded multilayer coatings to operate near peak reflectivities. For higher numerical apertures, the variation of the angle of incidence over the secondary mirror surface becomes a serious problem which must be solved before multilayer coatings can be used for this application. Tolerance analysis of the spherical Schwarzschild microscope has shown that water window operations will require 2-3 times tighter tolerances to achieve a similar performance for operations with 130 A radiation. Surface contour errors have been shown to have a significant impact on the MTF and must be controlled to a peak-to-valley variation of 50-100 A and a frequency of 8 periods over the surface of a mirror.

Shealy, David L.↗

Measuring EUV Line Emission from the Hot Interstellar Medium

In the local interstellar medium, the presence of hot gas was inferred from measurements of oxygen VI absorption in the ultraviolet, and from diffuse emission in the extreme ultraviolet (EUV) and soft X-ray regions. A spectrometer that is very sensitive to gas in this temperature range is described. The spectrometer uses an array of plane ruled gratings at grazing incidence in the extreme off plane mount. A set of Kirkpatrick-Baez mirrors focuses the conically diffracted light on to one of two microchannel plate detectors. The field of view of the instrument is 0.2 deg by 12 deg. The predicted sensitivity ranges from 50 to 200 ph/(sq cm sec str) with a resolving power of 15 to 50 over the 50 to 700 angstrom wavelength band.

Labov, S.↗

NASA astrophysics - Optical systems to explore the universe

Major and minor NASA astrophysical research efforts in the near-term are outlined, together with projections of direction for future projects. The Space Telescope is being readied for a 1986 launch and will feature an f/24, 2.4 m aperture, an MgF2 mirror with better than 1/60 wavelength accuracy and will be diffraction-limited in the UV. Pointing accuracy is designed to be 0.007 arcsec for 24 hr. Optical, spectrometric, and photometric equipment will be included. Around 1990, Shuttle-based missions will include an IR telescope and a subarcsec solar surface imaging device. A free-flying X-ray observatory (AXAF) is planned and will include a sensitivity that exceeds that of the HEAO-2 spacecraft by two orders of magnitude. Instruments are under development for higher resolution UV, gamma-ray, and IR studies. In-orbit interferometry is being studied and will depend on in-orbit assembly and servicing of stable structures with segmented optics.

Pellerin, C. J., Jr.↗

Carbyne forms of carbon - Do they exist

Carbynes, or polymorphs of elemental carbon first reported synthesized by Kasatochkin et al (1967), have generally been recognized by their characteristic hexagonal electron diffraction pattern. It is pointed out, however, that sheet silicate minerals give rise to hexagonal diffraction patterns with a similar range of interplanar spacings. A reexamination of reported occurrences of carbynes, including chaoite, by means of TEM shows that nontronite and quartz contaminants could account for most of the cases previously attributed to chaoite. It is recommended that in future searches for carbyne, energy-dispersive X-ray analyses should be conducted to verify the chemistry of individual, carbyne-candidate grains.

Smith, P. P. K.↗

X-ray optics - A technique for high resolution imaging

Both scattering and figure errors in grazing incidence optics are larger in the plane of incidence than out-of-plane by a factor equal to 1/sin theta, where theta is the graze angle. When the full annular aperture of a grazing incidence telescope is stopped down, the point spread function becomes highly elliptical with a width as much as sin theta times narrower than the full image. In practice, this means that improvements in resolution of up to 100 times can be achieved, and effective resolution can approach the diffraction limit. Laboratory data demonstrating the effect are presented.

Cash, Webster↗

Crystallization of the Fab from a human monoclonal antibody against gp 41 of human immunodeficiency virus type I

A monoclonal IgG antibody directed against gp 41 from the human immunodeficiency virus (HIV-1) has been crystallized in both intact and Fab forms. Crystals of the intact antibody grow as tetragonal-like prisms too small for conventional X-ray analysis. However, the Fab portion of the antibody produces suitable platelike crystals which belong to the space group P2(1)2(1)2(1) with unit cell constants of a = 66.5 A, b = 74.3 A, and c = 105.3 A. There is one molecule of Fab in the asymmetric unit. The Fab crystals show diffraction to d-spacings less than 3.0 A.

Casale, Elena↗

The soft X-ray/EUV calibration facility at the University of Colorado

The components of the calibration facility at the University of Colorado are described. The system is capable of analyzing the performance of optical components in the wavelength range from 2.7 to 2500 A. The system uses two light sources: a water-cooled hollow cathode gas discharge source and a soft X-ray source. The 2.2-m grazing incidence monochrometer, slits, large chamber, and computer-controlled manipulator are examined. The NBS aluminum oxide photodiode, a flowing gas proportional counter, and an imaging microchannel plate device are employed to detect the light. The optics, detectors, and data acquisition system are computer controlled. The facility is applicable for evaluating the performance of diffraction gratings, multilayer mirrors, reflective coatings, spectrographs, surface roughness scattering, and absolute detector efficiencies. Examples demonstrating the capabilities of the facility and a diagram of the facility are presented.

Windt, David L.↗

Measurements of striae in CR+ doped YAG laser crystals

Striations in Czochralski (CZ) grown crystals have been observed in materials such as GaAs, silicon, photorefractive crystals used for data storage, potassium titanyl phosphate crystals and LiNbO3. Several techniques have been used for investigating these defects including electron microscopy, laser scanning tomography, selective photoetching, X-ray diffuse scattering, interference orthoscopy, laser interferometry and micro-Fourier transform infrared spectroscopy mapping. A 2mm thick sample of the material to be investigated is illuminated with light that is absorbed and non-absorbed by the ion concentration to be observed. The back surface of the sample is focused onto a solid-state image detector and images of the input beam and absorbed (and diffracted) beams are captured at two wavelengths. The variation of the coefficient of absorption asa function of distance on the sample can be derived from these measurements. A Big Sky Software Beamcode system is used to capture and display images. Software has been written to convert the Beamcode data files to a format that can be imported into a spreadsheet program such as Quatro Pro. The spreadsheet is then used to manipulate and display data. A model of the intensity map of the striae collected by the imaging system has been proposed and a data analysis procedure derived. From this, the variability of the attenuation coefficient alpha can be generated. Preliminary results show that alpha may vary by a factor of four or five over distances of 100 mu m. Potential errors and problems have been discovered and additional experiments and improvements to the experimental setup are in progress and we must now show that the measurement techniques and data analysis procedures provide 'real' information. Striae are clearly visible at all wavelengths including white light. Their basic spatial frequency does not change radically, at least when changing from blue to green to white light. Further experimental and theoretical work can be done to improve the data collection techniques and to verify the data analysis procedures.

Cady, Fredrick M.↗

Amorphous silicon carbide coatings for extreme ultraviolet optics

Amorphous silicon carbide films formed by sputtering techniques are shown to have high reflectance in the extreme ultraviolet spectral region. X-ray scattering verifies that the atomic arrangements in these films are amorphous, while Auger electron spectroscopy and Rutherford backscattering spectroscopy show that the films have composition close to stoichiometric SiC, although slightly C-rich, with low impurity levels. Reflectance vs incidence angle measurements from 24 to 1216 A were used to derive optical constants of this material, which are presented here. Additionally, the measured extreme ultraviolet efficiency of a diffraction grating overcoated with sputtered amorphous silicon carbide is presented, demonstrating the feasibility of using these films as coatings for EUV optics.

Kortright, J. B.↗

Remote analysis of planetary soils: X-ray diffractometer development

A system is described suitable for remote low power mineralogical analysis of lunar, planetary, or asteroid soils. It includes an X-ray diffractometer, fluorescence spectrometer, and sample preparation system. A one Curie Fe-55 source provides a monochromatic X-ray beam of 5.9 keV. Seeman-Bohlin or focusing geometry is employed in the camera, allowing peak detection to proceed simultaneously at all angles and obviating the need for moving parts. The detector system is an array of 500-600 proportional counters with a wire-spacing of 1 mm. An electronics unit comprising preamplifier, postamplifier, window discriminators, and storage flipflops requiring only 3.5 milliwatts was designed and tested. Total instrument power is less than 5 watts. Powder diffraction patterns using a flat breadboard multiwire counter were recorded.

Gregory, J. C.↗

Design and analysis of soft X-ray imaging microscopes

The spherical Schwarzschild microscope for soft X-ray applications in microscopy and projection lithography consists of two concentric spherical mirrors configured such that the third-order spherical aberration and coma are zero. Since multilayers are used on the mirror substrates for X-ray applications, it is desirable to have only two reflecting surfaces in a microscope. To reduce microscope aberrations and increase the field of view, generalized mirror surface profiles are here considered. Based on incoherent and sine wave modulation transfer function calculations, the object plane resolution of a microscope has been analyzed as a function of the object height and numerical aperture (NA) of the primary for several spherical Schwarzschild, conic, and aspherical Head reflecting two-mirror microscope configurations. The Head microscope with a NA of 0.4 achieves diffraction limited performance for objects with a diameter of 40 microns. Thus, it seems possible to record images with a feature size less than 100 A with a 40x microscope when using 40 A radiation.

Shealy, David L.↗

Phosphate Textural Diversity in CI Chondrites and C-Type Asteroids

Introduction: Apatite, Ca 5 (PO 4 ) 3 (CL/F/OH-), is a ubiquitous phosphate found throughout the solar system, including the most primitive solids, CI-chondrites [1,2] and related samples of carbonaceous asteroids Ryugu [3] and Bennu [4], returned by JAXA’s Hayabusa2 and NASA’s OSIRIS-REx missions, respectively. Apatite in these primitive solids is found as individual grains or mineral clusters and has been inferred to form from the hydrothermal sequence during cooling of their respective parent body or bodies. To better understand the formation history and reworking of these early phosphates we have undertaken a highly coordinated study of phosphate microstructures, geochemistry and U/Pb geochronology from a suite of CI meteorites and carbonaceous asteroid samples. These data have identified novel phosphate microstructures and complex relationships across a suite of apatite grains from the early solar system, indicating multiple episodes of growth and modification on the CI parent body(ies). Methods: Samples of CI chondrites, Alais, Ivuna, Orgueil, Oued Chebeika 002, Yamato (Y) 82162, Y980115, Y980134, and two chips of Hayabusa2 Ryugu particles (A0262 and C0263) have been acquired for analysis. The bulk texture of the samples were first scanned by X-ray Computed Tomography (XCT) using the Nikon XT H 320 within the XFACT facility at NASA JSC or the Xradia 620 Versa at the UTCT facility. Based on the identification of petrofabrics or features of interest from the XCT data, samples were chipped, oriented, potted in epoxy and thick sections were prepared. After anhydrously polishing the samples with silicon carbide and dry diamond powder down to 1 µm, the samples were ion polished using a Hitachi ArBlade. Energy dispersive Xray spectrometry (EDS) maps were collected to ID phosphates of interest using a JEOL 7900F SEM. The internal microstructures of identified phosphates were then mapped by electron backscatter diffraction (EBSD) using the JEOL 7900F. Based on the EDS and EBSD data, domains of interest were targeted for quantitative chemical analyses using a JEOL 8530 EPMA. Subsequently, in situ U-Pb and 207 Pb/ 206 Pb ages will be collected using a Cameca ims1290 secondary ion mass spectrometer at UCLA across a range of microstructures. Results: Apatite grains are ubiquitous throughout the CI chondrites and carbonaceous asteroid materials, found as individual grains, disseminated clusters or grain aggregates. Apatite grains are associated with serpentine, magnet-ite, and/or carbonate. Of particular interest, we have identified individual and aggregate polycrystalline grains ex-hibiting an internal ‘honeycomb’ texture (Fig. 1). Some of these grains appear overprinted by subsequent alteration while others remain unaltered. Apatite halogen sites are dominated by the missing component, assumed to be OH, and F, comparable to published values from Bennu, Ryugu and CM-chondrites [3-5]. However, the Yamato CI-like meteorites show a broader range of Cl values, and one grain from Alais is dominated by CL. Summary: Apatite growth features indicate a protracted and complex growth history, consistent with precipitation from an evolving fluid system. The ‘honeycomb’ texture identified in some CI meteorites is, to the best of our knowledge, the first report of such a microstructure in meteoritic phosphate. The microtextures and zoning will guide subsequent age analyses, to better constrain the formation and reworking of phosphate in CI(-like) materials. Acknowledgments: We thank the National Institute of Polar Research, Japan for samples of Y82162, 980115 and 980134 meteorites, ASU’s Buseck Center for Meteorite Studies for samples of Ivuna and Alais meteorites, and JAXA curation for chips of Ryugu material. This work was funded by NASA ROSES LARS grant 24-LARS24-0014. References: [1] Morlok et al., 2016, GCA 70:5371-5394. [2] Alfin g et al., 2019, Geochemistry 79:125532. [3] Nakamura et al. (2022) Science 379:1-15. [4] Seifert et al. (2026) MAPS 61:504-521. [5] Piralla et al. (2021) MAPS 56:809-828.

CI chondrites↗

Review of rigorous coupled-wave analysis and of homogeneous effective medium approximations for high spatial-frequency surface-relief gratings

A review of the rigorous coupled-wave analysis as applied to the diffraction of electro-magnetic waves by gratings is presented. The analysis is valid for any polarization, angle of incidence, and conical diffraction. Cascaded and/or multiplexed gratings as well as material anisotropy can be incorporated under the same formalism. Small period rectangular groove gratings can also be modeled using approximately equivalent uniaxial homogeneous layers (effective media). The ordinary and extraordinary refractive indices of these layers depend on the gratings filling factor, the refractive indices of the substrate and superstrate, and the ratio of the freespace wavelength to grating period. Comparisons of the homogeneous effective medium approximations with the rigorous coupled-wave analysis are presented. Antireflection designs (single-layer or multilayer) using the effective medium models are presented and compared. These ultra-short period antireflection gratings can also be used to produce soft x-rays. Comparisons of the rigorous coupled-wave analysis with experimental results on soft x-ray generation by gratings are also included.

Glytsis, Elias N.↗

Advanced optical instruments technology

The science objectives for proposed NASA missions for the next decades push the state of the art in sensitivity and spatial resolution over a wide range of wavelengths, including the x-ray to the submillimeter. While some of the proposed missions are larger and more sensitive versions of familiar concepts, such as the next generation space telescope, others use concepts, common on the Earth, but new to space, such as optical interferometry, in order to provide spatial resolutions impossible with other concepts. However, despite their architecture, the performance of all of the proposed missions depends critically on the back-end instruments that process the collected energy to produce scientifically interesting outputs. The Advanced Optical Instruments Technology panel was chartered with defining technology development plans that would best improve optical instrument performance for future astrophysics missions. At this workshop the optical instrument was defined as the set of optical components that reimage the light from the telescope onto the detectors to provide information about the spatial, spectral, and polarization properties of the light. This definition was used to distinguish the optical instrument technology issues from those associated with the telescope, which were covered by a separate panel. The panel identified several areas for optical component technology development: diffraction gratings; tunable filters; interferometric beam combiners; optical materials; and fiber optics. The panel also determined that stray light suppression instruments, such as coronagraphs and nulling interferometers, were in need of general development to support future astrophysics needs.

Shao, Mike↗

Specimen Holder Design Improves Accuracy of X-Ray Powder Analysis

Specimen holder for X ray diffraction analysis presents the specimen to the incident X rays in a curvature. This permits the use of an X ray beam having a larger divergence angle, the beam intensity is increased, and the statistical accuracy of analysis is improved.

Mack, M.↗