Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Workflow management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

WE-DE-207A-02: Advances in Cone Beam CT Anatomical and Functional Imaging in Angio-Suite to Enable One-Stop-Shop Stroke Imaging Workflow

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-03: Recent Advances in Devices Used in Neuro--Interventions

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-04: Advances in Radiological Neuro-Endovascular Interventional Imaging

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

Developing an Automated Microscopic Traffic Simulation Scenario Generation Tool

Traffic simulation is an effective tool for urban planners, traffic engineers, and researchers to study traffic. In particular, microscopic traffic simulation, which simulates individual vehicles’ movements within a transportation network, has demonstrated its importance in analyzing and managing transportation systems. However, integrating data from various sources, generating traffic scenarios, and importing information into traffic simulators to conduct microscopic simulations have always been a challenge. This paper presents a solution to overcome this challenge: RealTwin, a comprehensive tool for automated scenario generation for microscopic traffic simulation. Following a streamlined scenario generation and calibration workflow, RealTwin effectively bridges gaps between traffic data from various sources and traffic simulators, making microscopic traffic simulation more accessible for researchers and engineers across various levels of expertise. Using RealTwin to generate a real-world traffic scenario in Simulation of Urban Mobility (SUMO), VISSIM, and AIMSUN, RealTwin’s ability is demonstrated in the construction of realistic and consistent traffic scenarios in different simulators. Furthermore, this paper introduces and illustrates RealTwin’s capability for technology (e.g., autonomous vehicle) scenario generation. This feature can contribute to more comprehensive microscopic simulations, facilitating the analysis of potential effects of various technological innovations on mobility, energy efficiency, and safety. Finally, RealTwin is used to calibrate a simulation in SUMO. In conclusion, the calibration module enhances RealTwin’s ability to generate consistent simulations across different platforms and more realistic simulations that reflect real-world traffic operations.

autonomous vehicle↗

Supplementary Data for "Evaluation of the Economic Implications of Varied Pressure Drawdown Strategies Generated Using a Real-time, Rapid Predictive, Multi-fidelity Model for Unconventional Oil and Gas Wells" by Bello, K., Vikara, D., Sheriff, A., Viswanathan, H., Carr, T., Sweeney, M., O'Malley, D., Marquis, M., Vactor, R.T., and Cunha, L.

The Bello et al. study evaluates the impact of contrasting pressure drawdown on gas productivity and the resulting economics of a well in the Marcellus Shale of the Appalachian Basin. This research applies a techno-economic analysis approach to help identify potential ways pressure management strategies can be used to improve cumulative recovery of hydraulically fractured horizontal wells while maintaining project profitability. Gas production forecast outlook scenarios of the Marcellus Shale Energy and Environment Laboratory Laboratory's MIP-3H well were generated under varying pressure drawdowns using two approaches: 1) a novel physics-informed machine learning (PIML) workflow and 2) via traditional reservoir simulation in Computer Modeling Group’s (CMG) GEM Compositional & Unconventional Simulator. Cash flow and other economic metrics of interest were compiled on the production outlook using the U.S. Department of Energy's (DOE) National Energy Technology Laboratory (NETL) Unconventional Shale Well Economic Model (UShWEM).The sheets within this Microsoft ExcelTM workbook provide the economic metric outputs for the baseline condition and the one-at-a-time (OAT) sensitivity analysis of UShWEM's input parameters for each of the production scenarios evaluated.

Fracture Network Model↗

The Invasive Species Forecasting System (ISFS): An iRODS-Based, Cloud-Enabled Decision Support System for Invasive Species Habitat Suitability Modeling

The Invasive Species Forecasting System (ISFS) is an online decision support system that allows users to load point occurrence field sample data for a plant species of interest and quickly generate habitat suitability maps for geographic regions of interest, such as a national park, monument, forest, or refuge. Target customers for ISFS are natural resource managers and decision makers who have a need for scientifically valid, model- based predictions of the habitat suitability of plant species of management concern. In a joint project involving NASA and the Maryland Department of Natural Resources, ISFS has been used to model the potential distribution of Wavyleaf Basketgrass in Maryland's Chesapeake Bay Watershed. Maximum entropy techniques are used to generate predictive maps using predictor datasets derived from remotely sensed data and climate simulation outputs. The workflow to run a model is implemented in an iRODS microservice using a custom ISFS file driver that clips and re-projects data to geographic regions of interest, then shells out to perform MaxEnt processing on the input data. When the model completes, all output files and maps from the model run are registered in iRODS and made accessible to the user. The ISFS user interface is a web browser that uses the iRODS PHP client to interact with the ISFS/iRODS- server. ISFS is designed to reside in a VMware virtual machine running SLES 11 and iRODS 3.0. The ISFS virtual machine is hosted in a VMware vSphere private cloud infrastructure to deliver the online service.

Gill, Roger↗

Complementary workflows for identifying one-hop network behavior and multi-hop network dependencies

A network analysis tool evaluates network flow information in complementary workflows to identify one-hop behavior of network assets and also identify multi-hop dependencies between network assets. In one workflow (e.g., using association rule learning), the network analysis tool can identify significant one-hop communication patterns to and/or from network assets, taken individually. Based on the identified one-hop behavior, the network analysis tool can discover patterns of similar communication among different network assets, which can inform decisions about deploying patch sets, mitigating damage, configuring a system, or detecting anomalous behavior. In a different workflow (e.g., using deep learning or cross-correlation analysis), the network analysis tool can identify significant multi-hop communication patterns that involve network assets in combination. Based on the identified multi-hop dependencies, the network analysis tool can discover functional relationships between network assets, which can inform decisions about configuring a system, managing critical network assets, or protecting critical network assets.

97 MATHEMATICS AND COMPUTING↗

Dust Control Planning

At the Hanford Site, dust control is required during many activities for health and safety purposes and to prevent contaminant dispersal via atmospheric transport. Water is commonly used to reduce dust dispersal, but can mobilize contaminants and facilitate transport through the vadose zone to groundwater as observed with past activities within the River Corridor. To prevent contaminant mobilization associated with remediation activities in the Central Plateau, alternative approaches for dust suppression are presented considering site-specific requirements at Hanford. There are two high-level categories of approaches to dust control: proactive work strategies to minimize fugitive dust generation and reactive engineered controls to mitigate dust generation and/or capture fugitive dust. Because a variety of activities have the potential to generate fugitive dust at a given site, there is no unique response to dust prevention and control. In fiscal year 2018, an evaluation was completed to identify alternatives, determine limits on surface water additions, and develop information suitable for consideration in feasibility studies. The technical basis detailed in the 2018 evaluation has been condensed into this document that provides a practical Dust Control Plan template and site-specific guidance in the appendices. This Dust Control Plan template specifically provides a workflow to 1) identify key project information, 2) identify fugitive dust sources, 3) assign dust control methods, and 4) determine appropriate monitoring practices to mitigate impacts to groundwater.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TU-E-BRB-00: Deformable Image Registration: Is It Right for Your Clinic

Deformable image registration (DIR) is developing rapidly and is poised to substantially improve dose fusion accuracy for adaptive and retreatment planning and motion management and PET fusion to enhance contour delineation for treatment planning. However, DIR dose warping accuracy is difficult to quantify, in general, and particularly difficult to do so on a patient-specific basis. As clinical DIR options become more widely available, there is an increased need to understand the implications of incorporating DIR into clinical workflow. Several groups have assessed DIR accuracy in clinically relevant scenarios, but no comprehensive review material is yet available. This session will also discuss aspects of the AAPM Task Group 132 on the Use of Image Registration and Data Fusion Algorithms and Techniques in Radiotherapy Treatment Planning official report, which provides recommendations for DIR clinical use. We will summarize and compare various commercial DIR software options, outline successful clinical techniques, show specific examples with discussion of appropriate and inappropriate applications of DIR, discuss the clinical implications of DIR, provide an overview of current DIR error analysis research, review QA options and research phantom development and present TG-132 recommendations. Learning Objectives: Compare/contrast commercial DIR software and QA options Overview clinical DIR workflow for retreatment To understand uncertainties introduced by DIR Review TG-132 proposed recommendations.

60 APPLIED LIFE SCIENCES↗

TU-E-BRB-02: DIR QA Options and Research Development

Deformable image registration (DIR) is developing rapidly and is poised to substantially improve dose fusion accuracy for adaptive and retreatment planning and motion management and PET fusion to enhance contour delineation for treatment planning. However, DIR dose warping accuracy is difficult to quantify, in general, and particularly difficult to do so on a patient-specific basis. As clinical DIR options become more widely available, there is an increased need to understand the implications of incorporating DIR into clinical workflow. Several groups have assessed DIR accuracy in clinically relevant scenarios, but no comprehensive review material is yet available. This session will also discuss aspects of the AAPM Task Group 132 on the Use of Image Registration and Data Fusion Algorithms and Techniques in Radiotherapy Treatment Planning official report, which provides recommendations for DIR clinical use. We will summarize and compare various commercial DIR software options, outline successful clinical techniques, show specific examples with discussion of appropriate and inappropriate applications of DIR, discuss the clinical implications of DIR, provide an overview of current DIR error analysis research, review QA options and research phantom development and present TG-132 recommendations. Learning Objectives: Compare/contrast commercial DIR software and QA options Overview clinical DIR workflow for retreatment To understand uncertainties introduced by DIR Review TG-132 proposed recommendations.

60 APPLIED LIFE SCIENCES↗

TU-E-BRB-03: Overview of Proposed TG-132 Recommendations

Deformable image registration (DIR) is developing rapidly and is poised to substantially improve dose fusion accuracy for adaptive and retreatment planning and motion management and PET fusion to enhance contour delineation for treatment planning. However, DIR dose warping accuracy is difficult to quantify, in general, and particularly difficult to do so on a patient-specific basis. As clinical DIR options become more widely available, there is an increased need to understand the implications of incorporating DIR into clinical workflow. Several groups have assessed DIR accuracy in clinically relevant scenarios, but no comprehensive review material is yet available. This session will also discuss aspects of the AAPM Task Group 132 on the Use of Image Registration and Data Fusion Algorithms and Techniques in Radiotherapy Treatment Planning official report, which provides recommendations for DIR clinical use. We will summarize and compare various commercial DIR software options, outline successful clinical techniques, show specific examples with discussion of appropriate and inappropriate applications of DIR, discuss the clinical implications of DIR, provide an overview of current DIR error analysis research, review QA options and research phantom development and present TG-132 recommendations. Learning Objectives: Compare/contrast commercial DIR software and QA options Overview clinical DIR workflow for retreatment To understand uncertainties introduced by DIR Review TG-132 proposed recommendations.

60 APPLIED LIFE SCIENCES↗

The Heroes' Problems: Exploring the Potentials of Google Glass for Biohazard Handling Professionals

In “white powder incidents” or other suspicious and risky situations relating to deadly diseases or chemicals (e.g., Ebola investigation), those who handle the potentially hazardous materials are the heroes who spearhead the first responder’s operations. Although well trained, these heroes need to manage complex problems and make life-or-death decisions while handling the unknown and dangerous. We are motivated to explore how Google Glass can facilitate those heroes’ missions. To this end, we conducted contextual inquiry on six biohazard-handling, Personal Protective Equipment (PPE)-wearing professionals. With an inductive thematic analysis, we summarized the heroes’ workflow and four groups of “Heroes’ Problems”. A unique “A3 Model” (Awareness, Analysis, Action) was generated to encapsulate our qualitative findings and proposed Glass features. The findings serve as the groundwork for our future development.

contextual inquiry↗

Automatic generation and simulation of urban building energy models based on city datasets for city-scale building retrofit analysis

Buildings in cities consume 30–70% of total primary energy, and improving building energy efficiency is one of the key strategies towards sustainable urbanization. Urban building energy models (UBEM) can support city managers to evaluate and prioritize energy conservation measures (ECMs) for investment and the design of incentive and rebate programs. This paper presents the retrofit analysis feature of City Building Energy Saver (CityBES) to automatically generate and simulate UBEM using EnergyPlus based on cities’ building datasets and user-selected ECMs. CityBES is a new open web-based tool to support city-scale building energy efficiency strategic plans and programs. The technical details of using CityBES for UBEM generation and simulation are introduced, including the workflow, key assumptions, and major databases. Also presented is a case study that analyzes the potential retrofit energy use and energy cost savings of five individual ECMs and two measure packages for 940 office and retail buildings in six city districts in northeast San Francisco, United States. The results show that: (1) all five measures together can save 23–38% of site energy per building; (2) replacing lighting with light-emitting diode lamps and adding air economizers to existing heating, ventilation and air-conditioning (HVAC) systems are most cost-effective with an average payback of 2.0 and 4.3 years, respectively; and (3) it is not economical to upgrade HVAC systems or replace windows in San Francisco due to the city's mild climate and minimal cooling and heating loads. Furthermore, the CityBES retrofit analysis feature does not require users to have deep knowledge of building systems or technologies for the generation and simulation of building energy models, which helps overcome major technical barriers for city managers and their consultants to adopt UBEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Where Is the Provenance? Ethical Replicability and Reproducibility in GIScience and Its Critical Applications

As replicability and reproducibility (R&R) crises develop within emerging convergent inquiry, ethical use of provenance information is central to the establishment and preservation of trust in critical applications of GIScience and geospatial technologies. Today large volumes of geospatial data are generated at high velocity from satellite sensors and unmanned aircraft systems, citizen sensors, geolocation-based data services, global navigation satellite systems, and so on. The extensive use of these data for applications such as disaster and humanitarian response raises the issue of R&R from competing perspectives of location privacy and geospatial data quality. Although geospatial data can be integrated and linked with contextual information to identify individuals’ movements, steps taken to ensure privacy can complicate the multiuser development of high-quality geospatial workflows. Provenance information as digital records of historical (retrospective) and potential future (prospective) geospatial processes is often overlooked, misunderstood, or inadequately addressed. We explore the relationship between provenance information, location privacy, and geospatial data quality in the context of R&R with a focus on disaster analytics. Here, we argue that in the era of big data and deep learning, GIScientists and associated institutions bear greater responsibility both for geospatial workflow quality and for location privacy. Given vastly heterogenous computational landscapes, we provide practical recommendations for ethically driven provenance and R&R research and development within the GIScience community and beyond.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Electronic Production Control System News Note

The CMD subprogram develops and deploys multi-application weapon component manufacturing capabilities needed to replace sunset technologies, upgrade existing technologies, and introduce new technologies that support the nuclear weapons stockpile. Sandia National Laboratories (SNL) is currently developing an Electronic Production Control System (EPCS) for ASIC production in the back end of line (BEOL) flow. A pre-production version of EPCS has been released and is operating as intended. We are currently processing all ASIC products, including CVV validation ASICs. The BEOL flow includes wafer probe, packaging, quality inspection, initial electrical test, dynamic burn-in, final electrical test, quality inspection, final visual inspection, radiation testing, SNL acceptance, DOE SSO acceptance, and qualification testing steps. EPCS will execute this production workflow (initiate, control, and electronically track each product); it will implement defect prevention strategies; it will create an electronic inventory control system that is accountable for all ASIC material from inception to delivery; it will electronically collect and store any and all required quality evidence and most of the electronic BEOL data; and it will create a management reporting module with production statistics and timelines. The defect prevention strategies include the use of 2D marks on our ASICs with 2D scanners so that there will be no manual entry of part numbers (scanners), will not allow testing the wrong parts in Test and Burn-in. Other defect prevention strategies will negate the possibility of neither using the wrong test or burn-in program for any part nor the use of BEOL machines or boards that are out of calibration. In summary, EPCS is being implemented and it will greatly improve the product acceptance through full electronic data collection and quality control and defect prevention through bar codes, scanners, tracking training of personnel, and tracking tool availability.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SNL ATDM Data and Visualization: IOSS and FAODEL

The SNL ATDM Data and Visualization project is developing data management software to improve how applications store and exchange large datasets efficiently on Exascale platforms. The data portion of this project is composed of two related efforts: (1) production work focused on improving Sandia's IOSS library for mesh datasets and (2) research work focused on developing new communication software named FAODEL that enables applications in a workflow to exchange data more efficiently.

97 MATHEMATICS AND COMPUTING↗

Bridging Equipment Reliability Data and Risk Informed Decisions in a Plant Operation Context

Industry equipment reliability and asset management programs are essential elements that help ensure the safe and economical operation of nuclear power plants. The effectiveness of these programs is addressed in several industry-developed and regulatory programs. The Risk-Informed Asset Management (RIAM) project is tasked to develop tools in support of the equipment reliability and asset management programs at nuclear power plants. These tools are designed to create a direct bridge between component health/lifecycle data and decision making (e.g., maintenance scheduling and project prioritization). The goal of this article is to provide a guide for specific use cases that the RIAM project is targeting. We have grouped uses cases into three main areas. The first area focuses on the analysis of equipment reliability data with a particular emphasis on condition-based data, such as test/surveillance reports and component monitoring data. The second area focuses on the integration of equipment reliability into system/plant reliability models to determine system/plant health and identify the components that are critical to maintain an operational system. Lastly, the third area manages plant resources, such as maintenance activities and replacement scheduling using optimization methods. Here the primary focus is on supporting typical system engineer decisions regarding maintenance activity scheduling and component aging management. This is performed in a risk-informed context where the term “risk” is broadly constructed to include both plant reliability and economics. This framework combines data analytics tools to analyze equipment reliability data with risk-informed methods designed to support system engineer decisions (e.g., maintenance and replacement schedules, optimal maintenance posture) in a customizable workflow.

97 - MATHEMATICS AND COMPUTING↗

High-resolution hourly surrogate modeling framework for physics-based large-scale building stock modeling

Surrogate modeling can play a key role in reducing high computational burdens for large-scale physics-based modeling and uncertainty quantification. With the rapid development of large-scale building stock energy modeling, surrogate modeling has also begun to be widely applied in this field; however, most existing surrogate models lack hourly time resolution for regional-scale modeling, which is essential for understanding building demand profiles and grid impacts. Further, there is generally a lack of necessary data and feature engineering frameworks specific to building modeling for efficiently managing large datasets and complex computations. Furthermore, this paper proposes a modeling framework for large-scale (city-/region-scale), high-resolution, high-fidelity surrogate building stock energy models. Our developed framework consists of six modules: (1) building stock energy modeling (ComStock TM and ResStock TM ), (2) data engineering for large simulation data, (3) high performance computing workflow, (4) feature engineering, (5) machine learning model development, and (6) model performance evaluation. Two case studies apply the developed framework in both residential and commercial building stock analysis to demonstrate its computational efficiency and surrogate modeling accuracies. Results show that surrogate models, when efficiently trained using the HPC workflow module, reach a high level of modeling accuracy for two case studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗