Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VIBRATION MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Cryogen-free variable temperature scanning SQUID microscope

Scanning Superconducting QUantum Interference Device (SQUID) microscopy is a powerful tool for imaging local magnetic properties of materials and devices, but it requires a low-vibration cryogenic environment, traditionally achieved by thermal contact with a bath of liquid helium or the mixing chamber of a “wet” dilution refrigerator. We mount a SQUID microscope on the 3 K plate of a Bluefors cryocooler and characterize its vibration spectrum by measuring SQUID noise in a region of sharp flux gradient. By implementing passive vibration isolation, we reduce relative sensor-sample vibrations to 20 nm in-plane and 15 nm out-of-plane. A variable-temperature sample stage that is thermally isolated from the SQUID sensor enables measurement at sample temperatures from 2.8 K to 110 K. We demonstrate these advances by imaging inhomogeneous diamagnetic susceptibility and vortex pinning in optimally-doped YBCO above 90 K.

47 OTHER INSTRUMENTATION↗

Design and implementation of wire tension measurement system for MWPCs used in the STAR iTPC upgrade

The STAR experiment at RHIC is planning to upgrade the Time Projection Chamber which lies at the heart of the detector. We have designed an instrument to measure the tension of the wires in the multi-wire proportional chambers (MWPCs) which will be used in the TPC upgrade. The wire tension measurement system causes the wires to vibrate and then it measures the fundamental frequency of the oscillation via a laser based optical platform. The platform can scan the entire wire plane, automatically, in a single run and obtain the wire tension on each wire with high precision. In this paper, the details about the measurement method and the system setup will be described. In addition, the test results for a prototype MWPC to be used in the STAR-iTPC upgrade will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Three-channel three-dimensional self-mixing thin-slice solid-state laser-Doppler measurements

We report successful real-time three-channel self-mixing laser-Doppler measurements with extreme optical sensitivity using a laser-diode-pumped thin-slice Nd:GdVO4 laser in the carrier-frequency-division-multiplexing scheme with three pairs of acoustic optical modulators (i.e., frequency shifters) and a three-channel FM-wave demodulation circuit. We demonstrate (1) simultaneous independent measurement of three different nanometer-vibrating targets, (2) simultaneous measurements of small particles in Brownian motion from three directions, and (3) identification of the velocity vector of small particles moving in water flowing in a small-diameter glass pipe.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identification of structural systems using naturally induced vibration data in the presence of measurement noise

The method of instrument variables for the identification of the parameters of structural systems excited by white noise in the presence of white measurement noise is applied. The requisite equations and the resulting consistent estimator are derived and simulation results for least squares and instrumental variables methods, for light and heavy damping, are compared. The present method gave better results than least squares when measurement noise was presented, and verified the fact that least squares yields an inconsistent estimator unless the measurement noise is zero.

Huan, S.-L.↗

Low Frequency Vibration Characteristics of the Space Acceleration Measurement System 2 Tape Drive Assembly

This report summarizes results of force and moment measurements of the Space Acceleration Measurement System 2 (SAMS 2) Tape Drive Assembly (TDA) over the frequency range from 0.35 Hz to 256 Hz for steady state operations including write, read, rewind, and fast forward. Time domain force results are presented for transient TDA operations that include software eject, manual eject, and manual load. Three different mounting configurations were employed for attaching the inner box with the tape drive unit to the outer box. Two configurations employed grommet sets with spring rates of 42 and 62 pounds per inch respectively. The third configuration employed a set of metallic washers. For all four steady state operations the largest average forces were on the Y axis with the metallic washers and were less than 0.005 pounds. The largest average moments were on the X axes with the washers and were less than 0.030 pound inches. At the third octave centerband frequency of 31.5 Hz, the 42 pound per inch grommets showed the greatest forces and moments for read and write operations. At the third octave centerband frequency of 49.6 Hz, the 62 pound per inch grommets showed the greatest forces and moments for rewind operation. Transient operation forces ranged from 0.75 pounds for the software eject to greater than 1 pound for manual load and eject.

Javeed, Mehzad↗

Improved Correction System for Vibration Sensitive Inertial Angle of Attack Measurement Devices

Inertial angle of attack (AoA) devices currently in use at NASA Langley Research Center (LaRC) are subject to inaccuracies due to centrifugal accelerations caused by model dynamics, also known as sting whip. Recent literature suggests that these errors can be as high as 0.25 deg. With the current AoA accuracy target at LaRC being 0.01 deg., there is a dire need for improvement. With other errors in the inertial system (temperature, rectification, resolution, etc.) having been reduced to acceptable levels, a system is currently being developed at LaRC to measure and correct for the sting-whip-induced errors. By using miniaturized piezoelectric accelerometers and magnetohydrodynamic rate sensors, not only can the total centrifugal acceleration be measured, but yaw and pitch dynamics in the tunnel can also be characterized. These corrections can be used to determine a tunnel's past performance and can also indicate where efforts need to be concentrated to reduce these dynamics. Included in this paper are data on individual sensors, laboratory testing techniques, package evaluation, and wind tunnel test results on a High Speed Research (HSR) model in the Langley 16-Foot Transonic Wind Tunnel.

Crawford, Bradley L.↗

Human Factors Assessment of Vibration Effects on Visual Performance During Launch

The Human Factors Assessment of Vibration Effects on Visual Performance During Launch (Visual Performance) investigation will determine visual performance limits during operational vibration and g-loads on the Space Shuttle, specifically through the determination of minimum readable font size during ascent using planned Orion display formats. Research Summary: The aim of the Human Factors Assessment of Vibration Effects on Visual Performance during Launch (Visual Performance) investigation is to provide supplementary data to that collected by the Thrust Oscillation Seat Detailed Technical Objective (DTO) 695 (Crew Seat DTO) which will measure seat acceleration and vibration from one flight deck and two middeck seats during ascent. While the Crew Seat DTO data alone are important in terms of providing a measure of vibration and g-loading, human performance data are required to fully interpret the operational consequences of the vibration values collected during Space Shuttle ascent. During launch, crewmembers will be requested to view placards with varying font sizes and indicate the minimum readable size. In combination with the Crew Seat DTO, the Visual Performance investigation will: Provide flight-validated evidence that will be used to establish vibration limits for visual performance during combined vibration and linear g-loading. o Provide flight data as inputs to ongoing ground-based simulations, which will further validate crew visual performance under vibration loading in a controlled environment. o Provide vibration and performance metrics to help validate procedures for ground tests and analyses of seats, suits, displays and controls, and human-in-the-loop performance.

Kritina Holden↗

Validation of Spectra and Phase in Sub-1 cm-1 Resolution Sum-Frequency Generation Vibrational Spectroscopy through Internal Heterodyne Phase-Resolved Measurement

Reliably determination of the spectral features and their phases in sum-frequency generation vibrational spectroscopy (SFG-VS) for surfaces with closely overlapping peaks has been a standing issue. Here we present two approaches towards resolving such issue. The first utilizes the high resolution and accurate lineshape from the recently developed sub-wavenumber high resolution broadband SFG-VS (HR-BB-SFG-VS), from which the detail spectral parameters, including relative spectral phases, of overlapping peaks can be determined through reliable spectral fitting. These results are further validated by using the second method that utilizes the azimuthal angle phase dependence of the z-cut α-quartz crystal, a common phase standard, through the spectral interference between the SFG fields of the quartz surface, as the internal phase reference, and the adsorbed molecular layer. Even though this approach is limited to molecular layers that can be transferred or deposited onto the quartz surface, it is simple and straightforward, as it requires only an internal phase standard with a single measurement that is free of phase drifts. More importantly, it provides unambiguous SFG spectral phase information of such surfaces. Using this method, the absolute phase of the molecular susceptibility tensors of the CH3, CH2 and chiral C-H groups in different Langmuir-Blodgett (LB) molecular monolayers and drop-cast peptide films are determined. These two approaches are fully consistent with and complement to each other, making both easily applicable tools in SFG-VS studies. More importantly, as the HR-BB-SFG-VS technique can be easily applied to various surfaces and interfaces, such validation of the spectral and phase information from HR-BB-SFG-VS measurement demonstrates it as one most promising tool for interrogating the detailed structure and interactions of complex molecular interfaces.

Environmental Molecular Sciences Laboratory↗

Resolved rotation–vibration non-equilibrium with rotational VIPA-CARS

Simultaneous rotational and vibrational temperatures are measured in an N 2 plasma with rotational coherent anti-Stokes Raman scattering (CARS) resolved with a virtually imaged phased array (VIPA)-based spectrometer. A VIPA spectrally separates rotational transitions for each vibrational state, allowing vibrational populations to be directly measured. VIPA-CARS is shown to provide more accurate measurements of non-equilibrium temperatures than grating-resolved rotational CARS. The general characteristics, limitations, and potential uses of VIPA-CARS are discussed.

Steinmetz, S. A. (ORCID:0000000311014662)↗

Ultrastable lasers based on vibration insensitive cavities

We present two ultrastable lasers based on two vibration insensitive cavity designs, one with vertical optical axis geometry, the other horizontal. Ultrastable cavities are constructed with fused silica mirror substrates, shown to decrease the thermal noise limit, in order to improve the frequency stability over previous designs. Vibration sensitivity components measured are equal to or better than 1.5x10{sup -11}/m s{sup -2} for each spatial direction, which shows significant improvement over previous studies. We have tested the very low dependence on the position of the cavity support points, in order to establish that our designs eliminate the need for fine tuning to achieve extremely low vibration sensitivity. Relative frequency measurements show that at least one of the stabilized lasers has a stability better than 5.6x10{sup -16} at 1 s, which is the best result obtained for this length of cavity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature Dependence of Nitrogen Broadening of the NO Fundamental Vibrational Band

We report measured N2-broadening coefficients, gamma (T), of approximately 70 transitions of the ground electronic state fundamental vibration-rotation band (v=1 (left arrow) 0) of NO at 183, 213 and 296K. In addition to the broadening asymmetry previously observed between the 2 pi 3/2 and 2 pi 1/2 state transitions, we also observed for most of the 2 pi 1/2 transitions an increased broadening of the f-lambda over e-lambda components. The temperature dependence of the broadening coefficients was characterized by the power law, gamma T = gamma 296 (296/T) (sup n).

Spencer, M. N.↗

Exchange bias properties of [Co/CoO]{sub n} multilayers

In this study, the exchange bias properties of four polycrystalline multilayer stack samples of antiferromagnetic (AF) CoO and ferromagnetic (FM) Co in the form of [CoO/Co]{sub n} with n = 1, 2, 3, and 5 are reported. The samples were grown on top of Si (001) substrates by using magnetron sputtering method. X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM) were used to determine the structural properties of the samples. XPS measurements of cobalt oxide layer revealed the coexistence of different phases in cobalt oxide as CoO and Co{sub 3}O{sub 4}, the latter of which lowers the blocking temperature. The blocking temperature is also affected by the finite size scaling effects observed in AF layers. In-plane ferromagnetic resonance (FMR) measurements revealed uniaxial in-plane magnetic anisotropy for the samples. Low temperature vibrating sample magnetometer measurements provided exchange bias with a stepwise character. Observed steps are believed to be due to magnetization reversals of individual FM layers with varying thicknesses, each of which is pinned through two interfaces from above and below with two AFM layers, except the uppermost FM Co layer with a single AFM neighbor.

36 MATERIALS SCIENCE↗

An evaluation of reaction wheel emitted vibrations for space telescope

Emitted forces and moments characteristics of the Space Telescope Reaction Wheel Assembly (ST RWA) were measured under room temperature and pressure, thermal extremes, and vibratory conditions. The RWA/Emitted Vibration Measurement Fixture was calibrated statically and dynamically, and background noise was measured with ST RWA not operating. A base line set of forces and moments of the ST RWA along and about three mutually perpendicular axes were recorded at room ambient. The temperature vibration sensitivites shown are those which were concluded to be a function of rotor unbalance changes and not associated with either spin motor nor rotor electronic changes.

Source record↗

Concorde noise-induced building vibrations John F. Kennedy International Airport

The outdoor and indoor noise levels resulting from aircraft flyovers and certain nonaircraft events were recorded at six home sites along with the associated vibration levels in the walls, windows, and floors of these test homes. Limited subjective tests conducted to examine the human detection and annoyance thresholds for building vibration and rattle caused by aircraft noise showed that both vibration and rattle were detected subjectively in several houses for some operations of both the Concorde and subsonic aircraft. Preliminary results indicate that the relationship between window vibration and aircraft noise is: (1) linear, with vibration levels being accurately predicted from OASPL levels measured near the window; (2) consistent from flyover to flyover for a given aircraft type under approach conditions; (3) no different for Concorde than for other conventional jet transports (in the case of window vibrations induced under approach power conditions); and (4) relatively high levels of window vibration measured during Concorde operations are due more to higher OASPL levels than to unique Concorde source characteristics.

Mayes, W. H.↗

Development of electron source feedback for enhanced X-ray beam stability at NSLS-II

Future synchrotron light sources are being designed to deliver significantly higher brightness and coherence, enabling faster scanning and more advanced imaging techniques. However, realizing these capabilities requires improved X-ray beam stability, as vibrations directly limit measurement accuracy and image quality. At the NSLS-II Hard X-ray Nanoprobe (HXN), a local mechanical feedback system mitigates low-frequency motion but provides only limited suppression of dominant vibrations at 27 Hz and 120 Hz. To address this limitation, this work explores the use of the electron beam itself as the actuator for feedback by integrating X-ray beam position monitor signals into the fast orbit feedback system through a dedicated electrometer. Experimental results show that this approach effectively suppresses the dominant vibration peaks and enhances stability at the focusing point. Benchmark ptychography measurements further confirm that electron-beam-based feedback reduces background fluctuations and mitigates vibration-induced artifacts under fast-scanning conditions. These results establish the feasibility of using the electron beam as a feedback actuator for next-generation synchrotron applications and provide an experimental assessment of its potential and limitations.

36 MATERIALS SCIENCE↗

Farfield Ion Current Density Measurements before and after the NASA HiVHAc EDU2 Vibration Test

There is an increasing need to characterize the plasma plume of the NASA HiVHAc thruster in order to better understand the plasma physics and to obtain data for spacecraft interaction studies. To address this need, the HiVHAc research team is in the process of developing a number of plume diagnostic systems. This paper presents the initial results of the farfield current density probe diagnostic system. Farfield current density measurements were carried out before and after a vibration test of the HiVHAc engineering development unit 2 that simulate typical launch conditions. The main purposes of the current density measurements were to evaluate the thruster plume divergence and to investigate any changes in the plasma plume that may occur as a result of the vibration test. Radial sweeps, as opposed to the traditional polar sweeps, were performed during these tests. The charged-weighted divergence angles were found to vary from 16 to 28 degrees. Charge density profiles measured pre- and post-vibration-test were found to be in excellent agreement. This result, alongside thrust measurements reported in a companion paper, confirm that the operation of the HiVHAc engineering development unit 2 were not altered by full-level/random vibration testing.

Huang, Wensheng↗