Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

A Natural ≳100× Telescope: Discovery of the Strongly Lensed Type II SN 2025mkn at z = 1.37

We present the discovery of SN 2025mkn, a gravitationally lensed Type II supernova. First detected as a blue transient in Zwicky Transient Facility (ZTF), 0. "83 from a z = 0.42 elliptical galaxy, the follow-up SNIFS/UH2.2 m and LRIS/Keck spectra revealed absorption lines at z = 1.371. Later JWST NIRCam imaging shows that the bright transient is a close pair of point sources separated by 0. "07, and a 30 times fainter counterimage opposite the lens, for which NIRSpec reveals strong Hα emission also at z = 1.371. The lightcurves and spectra are consistent with the Type II supernova source being magnified ≳100 times, with ∼250 required to reconcile its luminosity with that of nearby events such as SN 2023ixf. Lens models are consistent with such high magnifications, and always show that the faint image arrived first (undetected in earlier ZTF imaging), consistent with the later spectral phase of this fainter image. A fourth image is also predicted and possibly detected in the NIRSpec data. Lightcurve-based time-delay measurements are not possible due to the first image being the faintest; however, the resolved NIRSpec spectra offer a future opportunity for time-delay cosmography through supernova phase measurements.

Strong gravitational lensing↗

Imaging Valence Electron Rearrangement in a Chemical Reaction Using Hard X-Ray Scattering

We have observed the signatures of valence electron rearrangement in photoexcited ammonia using ultrafast hard x-ray scattering. Time-resolved x-ray scattering is a powerful tool for imaging structural dynamics in molecules because of the strong scattering from the core electrons localized near each nucleus. Such core-electron contributions generally dominate the differential scattering signal, masking any signatures of rearrangement in the chemically important valence electrons. Ammonia represents an exception to the typically high core-to-valence electron ratio. Here, we measured 9.8 keV x-ray scattering from gas-phase deuterated ammonia following photoexcitation via a 200 nm pump pulse to the 3s Rydberg state. We observed changes in the recorded scattering patterns due to the initial photoexcitation and subsequent deuterium dissociation. Ab initio calculations confirm that the observed signal is sensitive to the rearrangement of the single photoexcited valence electron as well as the interplay between adiabatic and nonadiabatic dissociation channels. The use of ultrafast hard x-ray scattering to image the structural rearrangement of single valence electrons constitutes an important advance in tracking valence electronic structure in photoexcited atoms and molecules.

Gabalski, Ian [SLAC National Accelerator Laborator↗

Observation of early shell-dopant mix in OMEGA direct-drive implosions and comparisons with radiation-hydrodynamic simulations

Temporally, spatially, and spectrally resolved x-ray image data from direct-drive implosions on OMEGA were interpreted with the aid of radiation-hydrodynamic simulations. Neither clean calculations nor those using a turbulent mix model can explain fully the observed migration of shell-dopant material (titanium) into the core. Shell-dopant migration was observed via time-dependent, spatially integrated spectra, and spatially and spectrally resolved x-ray images of capsule implosions and resultant dopant emissions. The titanium emission was centrally peaked in narrowband x-ray images. In post-processed clean simulations, the peak titanium emission forms in a ring in self-emission images as the capsule implodes. Post-processed simulations with mix reproduce trends in time-dependent, spatially integrated spectra, as well having centrally peaked Ti emission in synthetic multiple monochromatic imager. However, mix simulations still do not transport Ti to the core as is observed in the experiment. This suggests that phenomena in addition to the turbulent mix must be responsible for the transport of Ti. Simple diffusion estimates are unable to explain the early Ti mix into the core. Mechanisms suggested for further study are capsule surface roughness, illumination non-uniformity, and shock entrainment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Delrin registered for Propulsion with CO{sub 2} Laser: Carbon Doping Effects

Polyoxymethylene (POM) a.k.a. Delrin has been commonly used for propulsion with carbon dioxide (CO{sub 2}) lasers as a solid fuel providing excellent combination of coupling coefficient and specific impulse. In this paper the propulsive characteristics of white and black (carbon-doped) Delrin will be examined and compared. A Transverse Electric discharge in gas at Atmospheric pressure (TEA) CO{sub 2} laser with 300 ns pulse width was operated at up to 20 J pulse energy to produce irradiances on the order of 1-500 MW/cm{sup 2} on Delrin targets. Fourier Transform Infrared (FTIR) spectroscopy, time-resolved force sensors, a ballistic pendulum, and Schlieren imaging techniques were used to determine absorption spectra, coupling coefficient, specific impulse, and internal efficiency of Delrin. An analysis will be made of the possible routes for force generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved cryogenic electron tomography for the study of transient cellular processes

Cryogenic electron tomography (cryo-ET) is the highest resolution imaging technique applicable to the life sciences, enabling sub-nanometer visualization of specimens preserved in their near native states. The rapid plunge freezing process used to prepare samples lends itself to time-resolved studies, which researchers have pursued for in vitro samples for decades. Here, we focus on developing a freezing apparatus for time-resolved studies in situ. The device mixes cellular samples with solution-phase stimulants before spraying them directly onto an electron microscopy grid that is transiting into cryogenic liquid ethane. By varying the flow rates of cell and stimulant solutions within the device, we can control the reaction time from tens of milliseconds to over a second prior to freezing. In a proof-of-principle demonstration, the freezing method is applied to a model bacterium, Caulobacter crescentus, mixed with an acidic buffer. Through cryo-ET we resolved structural changes throughout the cell, including surface-layer protein dissolution, outer membrane deformation, and cytosolic rearrangement, all within 1.5 seconds of reaction time. This new approach, Time-Resolved cryo-ET (TR-cryo-ET), enhances the capabilities of cryo-ET by incorporating a sub-second temporal axis and enables the visualization of induced structural changes at the molecular, organelle, or cellular level.

59 BASIC BIOLOGICAL SCIENCES↗

Wave-by-Wave Forecasting via Assimilation of Marine Radar Data

Abstract This work describes a phase-resolving wave-forecasting algorithm that is based on the assimilation of marine radar image time series. The algorithm is tested against synthetic data and field observations. The algorithm couples X-band marine radar observations with a phase-resolving wave model that uses the linear mild slope equations for reconstruction of water surface elevations over a large domain of O (km) and a prescribed time window of O (min). The reconstruction also enables wave-by-wave forecasting through forward propagation in space and time. Marine radar image time series provide the input wave observations through a previously given relationship between backscatter intensity and the radial component of the sea surface slope. The algorithm assimilates the wave slope information into the model via a best-fit wave source function at the boundary that minimizes the slope reconstruction error over an annular region at the outer ranges of the radar images. The wave model is then able to propagate the waves across a polar domain to a location of interest at nearer ranges. The constraints on the method for achieving real-time forecasting are identified, and the algorithm is verified against synthetic data and tested using field observations.

Engineering↗

Time-Resolved Intrafraction Target Translations and Rotations During Stereotactic Liver Radiation Therapy: Implications for Marker-based Localization Accuracy

Purpose: Image guided liver stereotactic body radiation therapy (SBRT) often relies on implanted fiducial markers. The target localization accuracy decreases with increased marker-target distance. This may occur partly because of liver rotations. The aim of this study was to examine time-resolved translations and rotations of liver marker constellations and investigate if time-resolved intrafraction rotational corrections can improve localization accuracy in liver SBRT. Methods and Materials: Twenty-nine patients with 3 implanted markers received SBRT in 3 to 6 fractions. The time-resolved trajectory of each marker was estimated from the projections of 1 to 3 daily cone beam computed tomography scans and used to calculate the translation and rotation of the marker constellation. In all cone beam computed tomography projections, the time-resolved position of each marker was predicted from the position of another surrogate marker by assuming that the marker underwent either (1) the same translation as the surrogate marker; or (2) the same translation as the surrogate marker corrected by the rotation of the marker constellation. The localization accuracy was quantified as the root-mean-square error (RMSE) between the estimated and the actual marker position. For comparison, the RMSE was also calculated when the marker's position was estimated as its mean position for all the projections. Results: The mean translational and rotational range (2nd-98th percentile) was 2.0 mm/3.9° (right-left), 9.2 mm/2.9° (superior-inferior), 4.0 mm/4.0° (anterior-posterior), and 10.5 mm (3-dimensional). Rotational corrections decreased the mean 3-dimensional RMSE from 0.86 mm to 0.54 mm (P<.001) and halved the RMSE increase per millimeter increase in marker distance. Conclusions: Intrafraction rotations during liver SBRT reduce the accuracy of marker-guided target localization. Rotational correction can improve the localization accuracy with a factor of approximately 2 for large marker-target distances.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

orbitize! v3: Orbit fitting for the High-contrast Imaging Community

orbitize! is a package for Bayesian modeling of the orbital parameters of resolved binary objects from time series measurements. It was developed with the needs of the high-contrast imaging community in mind, and has since also become widely used in the binary star community. A generic orbitize! use case involves translating relative astrometric time series, optionally combined with radial velocity or astrometric time series, into a set of derived orbital posteriors. This paper is published alongside the release of orbitize! version 3.0, which has seen significant enhancements in functionality and accessibility since the release of version 1.0 (Blunt et al., 2020).

Sarah Blunt↗

Versatile, reprogrammable area pixel array detector for time-resolved synchrotron x-ray applications

The final technical report for DOE grant DE-SC0004079 is presented. The goal of the grant was to perform research, development and application of novel imaging x-ray detectors so as to effectively utilize the high intensity and brightness of the national synchrotron radiation facilities to enable previously unfeasible time-resolved x-ray research. The report summarizes the development of the resultant imaging x-ray detectors. Two types of detector platforms were developed: The first is a detector platform (called a Mixed-Mode Pixel Array Detector, or MM-PAD) that can image continuously at over a thousand images per second while maintaining high efficiency for wide dynamic range signals ranging from 1 to hundreds of millions of x-rays per pixel per image. Research on an even higher dynamic range variant is also described. The second detector platform (called the Keck Pixel Array Detector) is capable of acquiring a burst of x-ray images at a rate of millions of images per second.

47 OTHER INSTRUMENTATION↗

Imaging electron-density fluctuations by multidimensional X-ray photon-coincidence diffraction

The ultrafast spontaneous electron-density fluctuation dynamics in molecules is studied theoretically by off-resonant multiple X-ray diffraction events. The time- and wavevector-resolved photon-coincidence signals give an image of electron-density fluctuations expressed through the four-point correlation function of the charge density in momentum space. A Fourier transform of the signal provides a real-space image of the multipoint charge-density correlation functions, which reveal snapshots of the evolving electron density in between the diffraction events. The proposed technique is illustrated by ab initio simulations of the momentum- and real-space inelastic scattering signals from a linear cyanotetracetylene molecule.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamic Exploding Foil Initiator Imaging at the Advanced Photon Source

Recent advances in diagnostics coupled with synchrotron sources have allowed the in-situ investigation of exploding foil initiators (EFI) during flight. Herein, we present the first images of EFIs during flight utilizing x-ray phase contrast imaging at the Advanced Photon Source (APS) located in Argonne National Laboratory. These images have provided the DOE/DoD community with unprecedented images resolving details on the micron scale of the flyer formation, plasma instabilities and in-flight characteristics along with the subsequent interaction with high explosives on the nanosecond time scale. Phase contrast imaging has allowed the ability to make dynamic measurements on the length and time scale necessary to resolve initiator function and provide insight to key design parameters. These efforts have also probed the fundamental physics at “burst” to better understand what burst means in a physical sense, rather than the traditional understanding of burst as a peak in voltage and increase in resistance. This fundamental understanding has led to increased knowledge on the mechanisms of burst and has allowed us to improve our predictive capability through magnetohydrodnamic modeling. This manuscript presents results from several EFI designs along with a look to the future for upcoming work.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray radiographic expansion measurements of isochorically heated thin wire targets

Solid density matter at temperatures ranging from 150 eV to <5 eV has been created by irradiating thin wire targets with high-energy laser pulses at intensities ≈10{sup 18}W/cm{sup 2}. Energy deposition and transport of the laser-produced fast electrons are inferred from spatially resolved K{sub α}-spectroscopy. Time resolved x-ray radiography is employed to image the target mass density up to solid density and proves isochoric heating. The subsequent hydrodynamic evolution of the target is observed for up to 3 ns and is compared to radiation-hydrodynamic simulations. At distances of several hundred micrometers from the laser interaction region, where temperatures of 5–20 eV and small temperature gradients are found, the hydrodynamic evolution of the wire is a near axially symmetric isentropic expansion, and good agreement between simulations and radiography data confirms heating of the wire over hundreds of micrometers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved Polarimetry of the Superluminous SN 2015bn with the Nordic Optical Telescope

We present imaging polarimetry of the superluminous supernova SN 2015bn, obtained over nine epochs between −20 and +46 days with the Nordic Optical Telescope. This was a nearby, slowly evolving Type I superluminous supernova that has been studied extensively and for which two epochs of spectropolarimetry are also available. Based on field stars, we determine the interstellar polarization in the Galaxy to be negligible. The polarization of SN 2015bn shows a statistically significant increase during the last epochs, confirming previous findings. Our well-sampled imaging polarimetry series allows us to determine that this increase (from ∼0.54% to ≳1.10%) coincides in time with rapid changes that took place in the optical spectrum. We conclude that the supernova underwent a “phase transition” at around +20 days, when the photospheric emission shifted from an outer layer, dominated by natal C and O, to a more aspherical inner core, dominated by freshly nucleosynthesized material. This two-layered model might account for the characteristic appearance and properties of Type I superluminous supernovae.

79 ASTRONOMY AND ASTROPHYSICS↗

100-kHz Interferometric Rayleigh Scattering Flow Diagnostics at 266 nm

Interferometric Rayleigh scattering (IRS) is a laser-based technique capable of spatially and temporally resolved measurement of gas velocity and temperature in unseeded gaseous flows. In the present embodiment of the technique, IRS is performed at 266 nm for the first time. IRS at 266 nm is potentially much less susceptible to interferences from particles and other stray light sources. A pulse-burst laser and high-speed camera provided image rates of 100 kHz, allowing simultaneous space- and time-resolved measurement in high speed flow at multiple points along a line. The use of 266 nm excitation and detection is compared with prior work that used 532 nm. New experimental interferogram modelling and fitting techniques for single and multi-velocity-component IRS were demonstrated in a study of the spatial and temporal variation of the flow along a line through a supersonic jet. Single component velocity and temperature measurements using 266 nm were successfully made and compared with prior 532 nm results. Two-component velocity measurements at 266 nm, using the reflected image method, were compared to single-component measurements.

Andrew D Cutler↗

Proton radiography and fluoroscopy of lung tumors: A Monte Carlo study using patient-specific 4DCT phantoms

Purpose: Monte Carlo methods are used to simulate and optimize a time-resolved proton range telescope (TRRT) in localization of intrafractional and interfractional motions of lung tumor and in quantification of proton range variations. Methods: The Monte Carlo N-Particle eXtended (MCNPX) code with a particle tracking feature was employed to evaluate the TRRT performance, especially in visualizing and quantifying proton range variations during respiration. Protons of 230 MeV were tracked one by one as they pass through position detectors, patient 4DCT phantom, and finally scintillator detectors that measured residual ranges. The energy response of the scintillator telescope was investigated. Mass density and elemental composition of tissues were defined for 4DCT data. Results: Proton water equivalent length (WEL) was deduced by a reconstruction algorithm that incorporates linear proton track and lateral spatial discrimination to improve the image quality. 4DCT data for three patients were used to visualize and measure tumor motion and WEL variations. The tumor trajectories extracted from the WEL map were found to be within {approx}1 mm agreement with direct 4DCT measurement. Quantitative WEL variation studies showed that the proton radiograph is a good representation of WEL changes from entrance to distal of the target. Conclusions: MCNPX simulation results showed that TRRT can accurately track the motion of the tumor and detect the WEL variations. Image quality was optimized by choosing proton energy, testing parameters of image reconstruction algorithm, and comparing to ground truth 4DCT. The future study will demonstrate the feasibility of using the time resolved proton radiography as an imaging tool for proton treatments of lung tumors.

60 APPLIED LIFE SCIENCES↗

Detecting coherent core-hole wave-packet dynamics in N 2 by time- and angle-resolved inner-shell photoelectron spectroscopy

Here, we introduce an imaging technique to follow core-hole wave-packet oscillations in the nitrogen molecule. In this scheme, an attosecond x-ray pulse core-ionizes the nitrogen molecule and a subsequent attosecond x-ray pulse probes the evolution of the electron dynamics. We can image the oscillation of the core-hole between the two atomic sites by measuring the angular correlation between photoelectrons. Analytical relations for the angular correlation are derived based on the plane-wave approximation for the photoelectron wave function. We confirm these results with a scattering calculation for the photoelectron wave function. The feasibility of the experimental realization of this scheme is discussed in light of current and future capabilities of x-ray free-electron lasers.

74 ATOMIC AND MOLECULAR PHYSICS↗

RHESSI TESTS OF QUASI-THERMAL GAMMA-RAY BURST SPECTRAL MODELS

Prompt gamma-ray burst (GRB) spectra evolve on short timescales, suggesting that time-resolved spectral fits may help diagnose the still unknown prompt emission mechanism. We use broadband gamma-ray data from the Ramaty High-Energy Solar Spectroscopic Imager spacecraft to test quasi-thermal models with high signal-to-noise time-resolved spectra of nine bright GRBs. In contrast to results reported in more narrow energy bands, the quality of the fits of quasi-thermal models is poor in relation to fits of the phenomenological Band function. Moreover, the best-fit parameters for the simplest quasi-thermal model, a blackbody plus a nonthermal power law, show significant dependence on the fit band. Models that replace the power law with more complicated nonthermal functions are not robust for the data considered here and decrease the physical relevance of the fit blackbody.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗