Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TiP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Effects of four inlet and outlet tip-annulus-area blockage configurations on the performance of an axial-flow fan rotor

An axial-flow fan rotor was tested with four configurations of tip-annulus-area blockage to speeds as high as 0.8 of design speed. The rotor performance with the four blockage configurations is compared with the unblocked rotor performance and with blockage configurations previously investigated. The blockage configurations enable the rotor to operate in a stable condition, to much lower flows than the unblocked rotor, with no evidence of rotating stall. The blockage configurations were effective in reducing rotor torque and weight flow but were accompanied by reductions in pressure ratio and efficiency.

Osborn, W. M.↗

Modeling of turbine blade tip contact

A mathematical model is developed to evaluate a number of physical effects in turbomachine blade tip contact on the basis of a broad brush approach to provide insights without undue complexity. The analysis is restricted to the case of a shoe encountering a moving blade row and pressing against it with a fixed time-average force. Relative displacement components in the contact region are identified and determined. Two key equations are derived, where it is shown that wear rate plays a strong role in determining the traversal speed of the contact patch. The formula for estimating the size of the contact patch shows that the higher the traversal speed is, the wider is the contact patch.

Burton, R. A.↗

Effect of crack initiation, stable crack growth and unstable crack propagation on the crack-tip plastic zone

A technique for measuring the plastic zones associated with initial crack-tip yielding, subcritical crack growth, and unstable fracture is discussed. The results of the measurement of the locus of these yield regions, on center-cracked sheet and compact tension specimens of 7075-T6, 7075-T651, and 2024-T3 aluminum, are reported in this paper. It was found that a very accurate representation of the strains was obtained by this method and that the results added significant insight into the fracture process. The plastic zones were found to be approximately eight times wider in 2024-T3 than in the 7075-T6 sheets. The yield zones approached a maximum value after unstable fracture was attained and maintained that size through the fast fracture region. As expected, the plastic zones in the compact tension specimen were associated only with the formation of the shear lips and no plastic zones were observed in the fatigue precracked regions of either the center-cracked or compact-tension specimens.

Poulose, P. K.↗

Fan noise reduction at subsonic and supersonic tip speeds with high Mach number inlets

Results are presented for an experimental study of two fixed geometry inlets and one translating centerbody type inlet tested in an anechoic-chamber transonic-compressor facility. The test vehicle was a 12-inch tip diameter single-stage transonic compressor with 19 rotor blades and 30 stator blades located approximately two chord lengths downstream of the rotor. It is shown that the translating centerbody type of inlet is superior to the collapsing cowl type for noise reduction at high subsonic Mach numbers, both acoustically and aerodynamically. The feasibility of using a high inlet Mach number depends largely on the maximum area ratio requirement (normally at landing). The high inlet Mach numbers are more effective in reducing high-frequency noise than low frequencies and more effective in reducing the blade passage frequency than the overall noise level.

Lumsdaine, E.↗

Experimental performance of a 16.10-centimeter-tip-diameter sweptback centrifugal compressor designed for a 6:1 pressure ratio

A backswept impeller with design mass flow rate of 1.033 kg/sec was tested with both a vaned diffuser and a vaneless diffuser to establish stage and impeller characteristics. Design stage pressure ratio of 5.9:1 was attained at a flow slightly lower than the design value. Flow range at design speed was 6 percent of choking flow. Impeller axial tip clearance at design speed was varied to determine effect on stage and impeller performance.

Klassen, H. A.↗

Measurements of helicopter rotor tip vortices

This paper presents results from a recent wind-tunnel investigation of model helicopter rotor tip vortices. Measurements were made of the vortex positions, core sizes, and velocity distributions. A laser velocimeter was used to make the measurements, and a minicomputer-based data system was used to process the data and to aid in controlling the experiment. The velocimeter, the data system, and the software developed for the minicomputer are briefly described. The rotors investigated were two-bladed, teetering rotors with diameters of 2.1 m. Two sets of blades were used, one set with zero twist and one set with -11 deg of linear twist. The vortex positions were obtained by making flow field traverses while strobing the data system at a fixed azimuth. Aging of a vortex element was also studied by following the convected element while strobing the data system at different azimuths. By this method, the effects on the vortex of a close interaction with a blade and another vortex were studied.

Biggers, J. C.↗

Experimental performance of a 13.65-centimeter-tip-diameter tandem-bladed sweptback centrifugal compressor designed for a pressure ratio of 6

A 13.65 cm tip diameter backswept centrifugal impeller having a tandem inducer and a design mass flow rate of 0.907 kg/sec was experimentally investigated to establish stage and impeller characteristics. Tests were conducted with both a cascade diffuser and a vaneless diffuser. A pressure ratio of 5.9 was obtained near surge for the smallest clearance tested. Flow range at design speed was 6.3 percent for the smallest clearance test. Impeller exit to shroud axial clearance at design speed was varied to determine the effect on stage and impeller performance.

Klassen, H. A.↗

Aerodynamic investigation of an air-cooled axial-flow turbine. Part 2: Rotor blade tip-clearance effects on overall turbine performance and internal gas flow conditions: Experimental results and prediction methods

Total turbine blade performance was investigated while changing the blade tip clearance in three ways. The internal flow at the moving blade outlet point was measured. Experimental results were compared with various theoretical methods. Increased blade clearance leads to decreased turbine efficiency.

Yamamoto, A.↗

Cold-air performance of a tip turbine designed to drive a lift fan

Performance was obtained over a range of speeds and pressure ratios for a 0.4 linear scale version of the LF460 lift fan turbine with the rotor radial tip clearance reduced to about 2.5 percent of the rotor blade height. These tests covered a range of speeds from 60 to 140 percent of design equivalent speed and a range of scroll inlet total to diffuser exit static pressure ratios from 2.6 to 4.2. Results are presented in terms of equivalent mass flow, equivalent torque, equivalent specific work, and efficiency.

Haas, J. E.↗

Considerations in the design of tip-coupled air-transport systems

It is shown that the lift-drag ratio of tip-coupled systems can be expressed as a simple multiple of the lift-drag ratio of the isolated units comprising the system. When operated for maximum lift-drag ratio, the extent of the coupled system is limited by maximum lift coefficient, high-altitude engine characteristics, and degraded performance of the isolated unit climbing to couple into the system. When operated at constant altitude, the gain from coupling is severely limited. If the cruise altitude is that for best performance of the isolated unit, the system lift-drag ratio can be no better than twice that of the isolated unit even when an infinite number of units are coupled. System performance may be further degraded since span-load distributions which yield good performance for the individual units reduce the efficiency of the coupled system. Coupling a pair of modern transport aircraft results in only about half the expected gain because of a poor span-distribution across the coupled pair. The control deflections required to maintain roll and pitch equilibrium further degrade the possible gain.

Heyson, H. H.↗

Design and performance of a 427-meter-per-second-tip-speed two-stage fan having a 2.40 pressure ratio

The aerodynamic design and the overall and blade-element performances are presented of a 427-meter-per-second-tip-speed two-stage fan designed with axially spaced blade rows to reduce noise transmitted upstream of the fan. At design speed the highest recorded adiabatic efficiency was 0.796 at a pressure of 2.30. Peak efficiency was not established at design speed because of a damper failure which terminated testing prematurely. The overall efficiencies, at 60 and 80 percent of design speed, peaked at approximately 0.83.

Cunnan, W. S.↗

Analysis and preliminary design of an optical digital tip clearance sensor for propulsion control

Following the generation of several concepts for passive, digital compatible, optical sensors for propulsion control systems, a tip clearance sensor was chosen for further analysis and preliminary design. Emphasis was placed on application to the TF34 engine compressor section. Laboratory experiments were performed to investigate several optical aspects of the concept. Preliminary design included an assessment of all sensor elements and recommendations for development programs. Quantitative predictions were made of sensor performance. A test plan was written to demonstrate sensor feasibility and that the performance goals can be met. A continuing experimental and design effort was suggested.

Poppel, G. L.↗

Tone noise of three supersonic helical tip speed propellers in a wind tunnel at 0.8 Mach number

Three supersonic helical tip speed propellers were tested in the NASA Lewis 8- by 6-foot wind tunnel. Noise data were obtained while these propellers were operating at a simulated cruise condition. The walls of this tunnel were not acoustically treated and therefore this was not an ideal location for taking noise data, but it was thought that the differences in noise among the three propellers would be meaningful. The straight bladed propeller which did not incorporate sweep was the noisiest with the aerodynamically swept propeller only slightly quieter. However, the acoustically swept propeller was significantly quieter than the straight propeller, thereby indicating the merit of this design technique.

Dittmar, J. H.↗

Experimental investigation of effects of blade tip geometry on loads and performance for an articulated rotor system

Wind-tunnel tests of an aeroelastically designed helicopter rotor model were carried out to determine the effects on dynamic response and aerodynamic performance of varying the design of the outboard 8 percent of the blade lengths. Four different blade tip geometries or shapes having different amounts of planform sweep, thickness and chordwise taper, and anhedral angle were studied. Each configuration was tested at several shaft angles of attack for advance ratios of 0.20, 0.30, 0.35, and 0.40. For each combination of shaft angle and advance ratio, rotor lift was varied over a wide range to include high lift conditions.

Weller, W. H.↗

Acoustic analysis of aft noise reduction techniques measured on a subsonic tip speed 50.8 cm (twenty inch) diameter fan

Sound data which were obtained during tests of a 50.8 cm diameter, subsonic tip speed, low pressure ratio fan were analyzed. The test matrix was divided into two major investigations: (1) source noise reduction techniques; and (2) aft duct noise reduction with acoustic treatment. Source noise reduction techniques were investigated which include minimizing second harmonic noise by varying vane/blade ratio, variation in spacing, and lowering the Mach number through the vane row to lower fan broadband noise. Treatment in the aft duct which includes flow noise effects, faceplate porosity, rotor OGV treatment, slant cell treatment, and splitter simulation with variable depth on the outer wall and constant thickness treatment on the inner wall was investigated. Variable boundary conditions such as variation in treatment panel thickness and orientation, and mixed porosity combined with variable thickness were examined. Significant results are reported.

Stimpert, D. L.↗

Teetered, tip-controlled rotor: Preliminary test results from Mod-0 100-kW experimental wind turbine

Results of tests conducted using the MOD-0 100 kW experimental wind turbine are evaluated. The teetered rotor significantly decreased loads on the yaw drive mechanism and reduced blade cyclic flapwise bending moments by 25 percent at the 20 percent span location when compared to the rigid hub rotor. The teetered hub performed well, but impacted the teeter stops on occasion as wind speed and/or direction varied rapidly. The tip-controlled rotor performed satisfactorily with some expected loss of control when compared to the full span pitchable blade. The performance results indicate that a review of techniques used to calculate rotor power is in order.

Glasgow, J. C.↗

Forward acoustic performance of a shock-swallowing high-tip-speed fan (QF-13)

Forward noise and overall aerodynamic performance data are presented for a high-tip-speed fan having rotor blade airfoils designed to alter the conventional leading-edge bow shocks to weak, oblique shocks which are swallowed within the interblade channels. It was anticipated that the swallowed shocks would minimize the generation of multiple-pure-tone noise. In the speed range where the shocks presumably were swallowed, the multiple-tone noise was lowered only about 3 decibels. Comparison with several high-speed fans on a thrust-corrected basis indicates that the present fan was the quietest in total forward noise at low speeds but offered no advantage at high speeds.

Lucas, J. G.↗

Flow oscillations of spike-tipped bodies

The oscillating flow field around a spike-tipped body has been simulated by the numerical solution of the 3-D compressible Navier-Stokes equations at a Mach number of 3.0 and a nominal Reynolds number of 7.87 x 10 to the 6th/m. Computations were performed using a vectorized 3-D Navier-Stokes program on the STAR 100 computer. Numerical solutions confirmed the experimental result that the self-sustained oscillation occurs within a limited range of the protruded spike length to shoulder height ratio. The numerical result predicted correctly the discrete frequency range as well as the rms pressure intensity. The detailed flow structure is also presented and discussed.

Shang, J. S.↗