Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

National Virtual Biotechnology Laboratory: Report on Rapid R&D Solutions to the COVID-19 Crisis

With funding from the CARES Act, the U.S Department of Energy (DOE) established the National Virtual Biotechnology Laboratory (NVBL) in March 2020 to address key challenges associated with the COVID-19 crisis. NVBL brought together the broad scientific and technical expertise and resources of DOE’s 17 national laboratories to help tackle medical supply short ages, discover potential drugs to fight the virus, develop and validate COVID-19 testing methods, model disease spread and impact across the nation, and understand virus transport in buildings and the environment. National laboratory resources leveraged for this effort include a suite of world-leading user facilities broadly available to the research community, such as light and neutron sources, nanoscale science research centers, sequencing and biocharacterization facilities, and high-performance computing facilities. Within months, NVBL teams produced innovations in materials and advanced manufacturing that mitigated shortages in test kits and personal protective equipment (PPE), creating nearly 1,000 new jobs. They used DOE’s high-performance computers and light and neutron sources to identify promising candidates for antibodies and antivirals that universities and drug companies are now evaluating. NVBL researchers also developed new diagnostic targets and sample collection approaches, and supported U.S. Food and Drug Administration (FDA), Centers for Disease Control and Prevention (CDC), and U.S. Department of Defense (DoD) efforts to establish national guidelines used in administering millions of tests. Researchers used artificial intelligence and high-performance computing to produce near-real-time data analysis to forecast disease transmission, stress on public health infrastructure, and economic impact, which supported decision-makers at the local, state, and national levels. NVBL teams also studied how to control indoor virus movement to minimize uptake and protect human health. NVBL’s accomplishments demonstrate not only the powerful resource represented by DOE’s national laboratories working together to meet national needs, but also the effectiveness of the integrated NVBL framework for rapidly responding to emergencies with research and development (R&D) solutions. As the fight against COVID continues, sustained efforts are needed to confront this pandemic as well as future threats. Examples include: 1) Establishing “supply chains on demand” to meet emergency production needs by leveraging the materials and manufacturing expertise of DOE national laboratories and developing advances in electronics, sensing, robotics, and automation capabilities; 2) Improving the speed and robustness of drug discovery by integrating experimental platforms with DOE’s computational and experimental user facilities, which provide unique resources to support the discovery of high-potential therapeutic agents; 3) Protecting public, environmental, and animal health by developing new testing protocols and instrumentation adaptable to diverse sample types (both physiological and environmental) to quickly detect a wide range of pathogens and monitor other biorisks; 4) Supporting near-real-time data needs of decision-makers at the local, regional, state, and national levels by advancing data curation, analysis, and modeling using artificial intelligence and new data science tools for managing and evaluating large diverse datasets; 5) Harnessing DOE’s expertise in environmental modeling to design rooms and air handling for offices, classrooms, restaurants, and other structures to minimize biorisk transmissions. Going forward, NVBL is poised to apply the unique capabilities and expertise of the national laboratory complex to future national and international emergencies, both natural and engineered. Through this framework, the Office of Science will continue to be an integral component of agency wide efforts to prepare for and respond to biorisks and other crises.

42 ENGINEERING↗

Investigation and quantification of nonlinearity using surrogate data in a glow discharge plasma

Detection of nonlinearity has been carried out in periodic and aperiodic floating potential fluctuations of DC glow discharge plasma by generating surrogate data using iterative amplitude adjusted Fourier transform method. We introduce “delay vector variance” analysis (DVV) for the first time, which allows reliable detection of nonlinearity and provides some easy to interpret diagram conveying information about the nature of the experimental floating potential fluctuations (FPF). The method of false nearest neighbourhood is deployed on the FPF's to find a good embedding so as to be acquainted with the precise knowledge of m, which is desirable for carrying out DVV analysis. The emergence of nonlinearity with increase in discharge voltage has been ensured by taking into consideration the total energy present in different band of frequencies excited due to nonlinear processes. Rejection of null hypothesis has been verified by performing the rank test method that confirms the presence of nonlinearity quantitatively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel nanorods based on PANI / PEO polymers using electrospinning method

In this work, we fabricated nanorods by applying an electric potential on poly (ethylene oxide) (PEO) and polyaniline (PANI) as a polymeric solution by electrospinning method. Testing was conducted on the samples by field emission scanning Electron microscope (FE-SEM), X-ray diffraction (XRD) and Photoluminescence. And the results showed the emergence of nanorods in the sample within glass substrate. Diameters of nanorods have ranged between (52.78-122.40)nm And a length of between (1.15 – 1.32)μm. The emergence of so the results are for the first time, never before was the fabrication of nanorods for polymers using the same method used in this research.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Alternate Methods for Cleaning Zirconium Plate

The United States High Performance Research Reactor Conversion Program identified the need to transition from highly enriched uranium fuel to lowly enriched uranium fuel for high power research and civil reactors. One of the fuel configurations selected for these reactors was a uranium (U) foil alloyed with 10% molybdenum (Mo). The U-10Mo fuel foil was then covered with a zirconium (Zr) interlayer and pressed into an aluminum cladding. Idaho National Laboratory prescribed a need to remove surface oxidation on the Zr prior to bonding it with U-10Mo fuel foil. To determine the best method of oxidation removal, a variety of polishing methods, including hand polishing with a diamond paste or Scotch-Brite™ pads, mechanically wet-polishing with abrasive belts, and chemical etching with hydrofluoric/nitric acid mixtures, were investigated on pre-polished Zircaloy 702 sheets purchased directly from the manufacturer. No change in surface roughness was detected using any of these methods relative to the as-received material. In fact, scanning electron microscopy detected grit from hand polishing with Amplex Grade 30 waste soluble diamond paste and Scotch-Brite™ pads. Visible staining was found, and fluorine detected via X-ray photoelectron spectroscopy on the flash etching samples. These contaminants were not seen on the as-received material. In addition to the need to remove the oxide layer on the Zr prior to co-rolling, there are concerns that the Neolube debonding agent on the co-rolling can may contaminate the Zr surface after co-rolling. The experimental results found that zirconium in contact with Neolube coated steel plates was easily cleaning with ethanol wiping after heat treated and no carbide inclusions remained on the surface. Overall, all cleaning methods tested did not significantly change the surface roughness of the plates or reduce the oxide layer present on the zirconium. Carbon was found on all the samples, before and after cleaning, except for the flash etch samples which detected fluorine instead. The insignificant changes seen in the cleaned plates relative to the as received plates question the need for cleaning prior to rolling. Further investigation in the requirements for cleaning at this step is recommended. Current methods for cleaning the surface after hot rolling with alcohol appear sufficient. After hot rolling, if Neolube does peel off the can and onto the zirconium coated foil surface, a dry abrasive or diamond paste polish is not recommended due to the chance of abrasive being embedded into the surface. However, the ability of an etchant to lift the lubricant off the zirconium surface indicates that a spot etch method could work to clean specific spots where Neolube is present, if the need arises.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Use of Multiple Criteria to Map the High-Temperature Scuffing Behaviorof Co-Based Superalloys

The goal of thisworkwas to rank, as quantitatively as possible, the high-temperature scuffing characteristics of a series of Co-based materials, including coatings, for possible use inwear-critical components like those in diesel engine exhaust systems and emission-controls. A cylinder pivoting on its side against a flat tilewas used as the testing geometry. All testswere performed at 600 C in air. The time-dependent torque response was recorded for each 60 min test to investigate trends in friction as surfaces roughened and debris deposits built up. Candidate materials included Stellite 6B, Pleuco 33 (a white cast iron), nitrided stainless steel Type 310, IDM 5399 (a high-silicon, molybdenum iron), and coatings of both Tribaloy T-400 and Stellite 3 on stainless steel. Measurements of the damaged areas on the scuffed tiles were used to calculate a specific normal load and plot it versus the roughness of the worn tiles to map experimental results in a way that indicated the severity of scuffing for each material combination. Data on the map were annotated to reflect visual observations of the extent of damage as well. Using this test method and the foregoing criteria, nitrided type 310 stainless steel against T-400 gave the best overall performance.

33 ADVANCED PROPULSION SYSTEMS↗

Performance of the Fluidized Bed Steam Reforming Product Under Hydraulically Unsaturated Conditions

Currently, several candidates for secondary waste immobilization at the Hanford site in the State of Washington, USA are being considered. To demonstrate the durability of the product in the unsaturated Integrated Disposal Facility (IDF) at the site, a series of tests have been performed one of the candidate materials using the Pressurized Unsaturated Flow (PUF) system. The material that was tested was the Fluidized Bed Steam Reformer (FBSR) granular product and the granular product encapsulated in a geopolymer matrix. The FBSR product is composed primarily of an insoluble sodium aluminosilicate matrix with the dominant phases being feldspathoid minerals mostly nepheline, sodalite, and nosean. The PUF test method allows for the accelerated weathering of materials, including radioactive waste forms, under hydraulically unsaturated conditions, thus mimicking the open-flow and transport properties that most likely will be present at the IDF. The experiments show a trend of decreasing tracer release as a function of time for several of the elements released from the material including Na, Si, Al, and Cs. However, some of the elements, notably I and Re, show a steady release throughout the yearlong test. This result suggests that the release of these minerals from the sodalite cage occurs at a different rate compared with the dissolution of the predominant nepheline phase.

Durability testing↗

Accurate and rapid acoustic damage characterization in complex structures using sparse sensor networks and deep learning models

Damage diagnosis in critical components is essential for ensuring the safety and reliability of operations across industries, spanning manufacturing, aerospace, and energy. Traditional acoustic nondestructive testing methods primarily focus on detecting defects through the direct scattering of single-mode incident waves from the damage, which limit their applicability to simple structures and small inspection areas. Our earlier research demonstrated that machine learning algorithms combined with sparse sensor networks can identify critical defect signatures even from multiply scattered, multi-mode acoustic signals, indicating the potential for improved defect inspection in complex, real-world structures. In this work, we demonstrate the successful implementation of this approach in a fixed sensor configuration to rapidly and accurately detect simulated defects in a geometrically complex, real-world structure, a brake rotor hub. Three different types of defects were physically simulated on the surface of the hub, and the collected data were used to train an autoencoder-based deep learning model. Two models were tested, one using single measurements and the other using multiple measurements taking advantage of the spatial distribution of the sensor network. After training, the multi-measurement model achieved 100 % accuracy in identifying, classifying, and locating unseen, unique damages. This work illustrates the potential of the proposed method for a wide range of industrial applications.

36 MATERIALS SCIENCE↗

A high-speed micro-impact testing system for evaluating the properties of lead-free solder joints

ConclusionThis study presents a novel high-speed micro-impact testing system for evaluating the shear strength and energy absorbance properties of lead-free solder ball joints under impact velocities of 0.3–1.0 m/s. The test method can examine the failure mode transition from ductile failure to brittle failure based on the failure mode distribution percentage. The load—displacement curves can distinguish between different failure modes. Notably, the values of peak load and the energy-to-peak load at various impact speeds can be used as indices for determining solder ball under impact loading conditions. Thus, the proposed method is a suitable technique for evaluating the mechanical response of solder ball joints used in typical semiconductor packages and, therefore, represents a simple and effective technique for optimizing the chip-level reliability of portable consumer electronic products.

36 MATERIALS SCIENCE↗

Assessing liver function: diagnostic efficacy of parenchymal enhancement and liver volume ratio of Gd-EOB-DTPA-enhanced MRI study during interstitial and hepatobiliary phase

Aim: To assess the efficacy of signal intensity in interstitial and hepatobiliary phase normalized for liver volume, on gadolinium-ethoxybenzyl-diethylenetriaminepentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) study, for the evaluation of liver function through the comparison with Child–Pugh (CP), model for end-stage liver disease (MELD), and biochemical tests. Methods: All dynamic Gd-EOB-DTPA MRI studies performed in patients with suspected liver lesions were retrospectively reviewed. The rate of liver-to-muscle ratio on T1 sequence 70 s (interstitial phase) and 20 min (hepatobiliary phase) after injection of Gd-EOB-DTPA was calculated for each MRI study and then normalized for liver volume (irINTnorm and irHEPnorm). Pearson correlation coefficient was computed to assess the correlation among these values and CP and MELD scores, and biochemical tests. Results: A total of 303 MRI studies, performed on 221 patients, were included. Mean age was 63.8 years ± 12.9 with a majority of male patients (186; 61.4%). A total of 186 out of 303 (61.4%) were cirrhotic patients. The irHEPnorm was significantly lower in cirrhotic than non-cirrhotic patients (0.0004 ± 0.0002 to 0.0005 ± 0.0003, p = 0.010). This value had a moderate, significant correlation with Child–Pugh and MELD scores (R = − 0.292, p < 0.0001 and R = − 0.192, p = 0.010, respectively). In particular, irHEPnorm progressively decreased from Child–Pugh A to C (0.0004–0.0002, p < 0.0001) and from MELD ≤ 10 to 19–24 (0.0004–0.0003, p = 0.018). Among biochemical parameters, total bilirubin, GOT, and albumin had the strongest correlation with irHEPnorm (R = − 0.258, − 0.291, and 0.262, p < 0.0001, respectively). No correlations were found between irINTnorm and CP and MELD scores. Conclusion: irHEPnorm value derived from Gd-EOB-DTPA-enhanced MRI is a reliable, non-invasive, useful tool to quantify liver function and to assess the degree of cirrhosis, offering a strict relationship with clinical scores and biochemical parameters. This could help surgeons in clinical decision-making, allowing them to choose the more suitable surgical approach for cirrhotic patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of commercial proton exchange membrane materials after exposure to beta and gamma radiation

Proton Exchange Membrane (PEM) type electrolysis cells have a potential use for tritium removal and heavy water upgrading. AECL is currently exposing various commercial PEM materials to both gamma (Cobalt-60 source) and beta (tritiated water) radiation to study the effects of radiation on these materials. This paper summarizes the testing methods and results that have been collected to date. The PEM materials that are or have been exposed to radiation are: Nafion 112, 212, 117 and 1110. Membrane characterization pre- and post- exposure consists of non-destructive inspection (FTIR, SEM/XPS), mechanical (tensile strength, percentage elongation, and modulus), electrical (resistance), or chemical (ion-exchange capacity - IEC). It has appeared that the best characterization techniques to compare exposed versus unexposed membranes were IEC, ultimate tensile strength and percent elongation. These testing techniques are easy and cheap to perform. The non-destructive tests, such as SEM and FTIR did not provide particularly useful information on radiation-induced degradation. Where changes in material properties were measured after radiation exposure, they would be expected to result in poorer cell performance. However, for modest γ-radiation exposure, all membranes showed a slight decrease in cell voltage (better performance). In contrast, the one β-radiation exposed membrane did show the expected increase in cell voltage. The counterintuitive trend for γ-radiation exposed membranes is not yet understood. Based on these preliminary results, it appears that γ- and β-radiation exposures have different effects.

07 ISOTOPE AND RADIATION SOURCES↗

Sampling Microbial Dynamics in the Salish Sea Estuary: Evaluating Methods to Capture Cyanobacteria and Cyanophage

Introduction: Picocyanobacteria from the genera Prochlorococcus and Synechococcus thrive across the globe in aquatic environments, have relatively small genomes, and have growth dynamics regulated by both viral interactions and abiotic conditions, making them excellent model organisms for exploring host-pathogencoevolution. Methods: We developed and refined methods to sample and sequence cyanobacteria, cyanophages, and measured features of their abiotic environment. Results: The protocol described herein can successfully discriminate large-cell eukaryotic organisms, but size fractionation of picocyanobacteria appears to be affected by the presence of free DNA, multicellular structures, and abundant tycheposons. Our preferred final protocol from this exploratory effort included a combination of in-line and single vacuum flask filtrations, which reduced filtration processing time by over threefold in some cases compared to other tested methods, such as a fully in-line sequence or in-site filtrations. We successfully extracted an average of approximately 400–1200 ng for all filter fractions, with some variations between kits. Discussion: The protocol described herein can successfully discriminate large-cell eukaryotic organisms, but size fractionation of picocyanobacteria appears to be affected by the presence of free DNA, multicellular structures, and abundant tycheposons.

Salish Sea↗

Building fault detection data to aid diagnostic algorithm creation and performance testing

It is estimated that approximately 4-5% of national energy consumption can be saved through corrections to existing commercial building controls infrastructure and resulting improvements to efficiency. Correspondingly, automated fault detection and diagnostics (FDD) algorithms are designed to identify the presence of operational faults and their root causes. A diversity of techniques is used for FDD spanning physical models, black box, and rule-based approaches. A persistent challenge has been the lack of common datasets and test methods to benchmark their performance accuracy. This article presents a first of its kind public dataset with ground-truth data on the presence and absence of building faults. This dataset spans a range of seasons and operational conditions and encompasses multiple building system types. It contains information on fault severity, as well as data points reflective of the measurements in building control systems that FDD algorithms typically have access to. The data were created using simulation models as well as experimental test facilities, and will be expanded over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computed Tomography Scanning and Geophysical Measurements of the Marcellus Formation from the Whipkey ST 1 Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown, West Virginia site were used to characterize core of the Marcellus Formation from a vertical well drilled in Greene County, Pennsylvania by the Energy Corporation of America. The core is from the Whipkey ST 1 well, in the Carmichaels Field, and is comprised primarily of the Marcellus Formation from depths of 7,719 to 7,910.8 ft. Core was provided by Tim Carr and Keithan Martin (West Virginia University and ORISE). The primary impetus of this work is a collaboration between West Virginia University (WVU) and NETL to characterize core from multiple wells to better understand the structure and variation of the Marcellus and Utica Shale Formations. As part of this effort, bulk scans of core were obtained from the Whipkey ST 1 well. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/whipkey-well. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations that have traditionally been performed at NETL.

58 GEOSCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the Rogersville Shale from the Smith #1 Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown, West Virginia site were used to characterize a core from the Rogersville Shale. This sample was taken from a vertical well, the Jay P. Smith #1 well (47-099-1572), drilled in Wayne County, West Virginia by the Exxon Company in the Elmwood Prospect. The core is comprised primarily of the Rogersville Shale from depths of 11,135 to 11,200.5 ft. This unit is a potential Cambrian oil/gas target, making it of recent interest to multiple groups. The core was provided by the West Virginia Geologic and Economic Survey (WVGES). The primary impetus of this work is a collaboration between WVGES and NETL to characterize core from multiple wells to better understand the structure and variation of key formations in West Virginia (e.g. Crandall et al., 2018a,b). As part of this effort, bulk scans of core were obtained from the Smith #1 well. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/roger-well. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provides both a macro and micro description of the core that is relevant for many subsurface energy-related examinations that have traditionally been performed at NETL.

04 OIL SHALES AND TAR SANDS↗

Computed Tomography Scanning and Geophysical Measurements of the Marcellus Formation from the Armstrong #1 Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from the Marcellus Formation. The core is from a vertical well (Armstrong #1) drilled in Taylor County, West Virginia by the Petroleum Development Corporation (7,545 to 7,783.4 ft). Core was provided by Phillip Dinterman, West Virginia Geologic and Economical Survey (WVGES) and Tim Carr and Keithan Martin, West Virginia University (WVU). The primary impetus of this work is a collaboration between NETL, WVGES, and WVU to characterize core from multiple wells to better understand the structure and variation of the Marcellus and Utica Shale formations. As part of this effort, bulk scans of core were obtained from the Armstrong #1 well. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/armstrong-well. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

47 OTHER INSTRUMENTATION↗

Computed Tomography Scanning and Geophysical Measurements of the Enhanced Geothermal Systems (EGS) Collab SURF Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from 8 wells from the Enhanced Geothermal Systems (EGS) Collab project located in the Sanford Underground Research Facility’s (SURF) 4850 level. The work in this report falls in Experiment 1 in a three-phase experiment, with the primary purpose to increase understanding of hydraulic fracturing. The primary impetus of this work is a collaboration between U.S. Department of Energy (DOE) and the EGS Collab. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/surf-collab-core. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the pore space in the core, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

47 OTHER INSTRUMENTATION↗

Computed Tomography Scanning and Geophysical Measurements of the Patterson #5-25 Well in Western Kansas

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) site in Morgantown, West Virginia, were used to characterize core from the Patterson Field site. This core came from a vertical well (Patterson #5-25 well) that was obtained as part of the U.S. Department of Energy (DOE) sponsored Integrated Midcontinental Stacked Carbon Storage Hub. The primary impetus of this work is a collaboration between NETL and the Kansas Geological Survey to characterize core from the Patterson Field site. The 625 ft of whole core from the Atoka Formation to Precambrian Basement was characterized at NETL. As part of this effort, bulk scans of core were obtained. This report, and the associated scans, provide detailed datasets not typically made publicly available for carbon capture utilization and storage analysis. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/patterson-5-25-well. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with x-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL are useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations that have traditionally been performed at NETL.

58 GEOSCIENCES↗

WE-EF-207-09: Single-Scan Dual-Energy CT Using Primary Modulation

Purpose: Compared with conventional CT, dual energy CT (DECT) provides better material differentiation but requires projection data with two different effective x-ray spectra. Current DECT scanners use either a two-scan setting or costly imaging components, which are not feasible or available on open-gantry cone-beam CT systems. We propose a hardware-based method which utilizes primary modulation to enable single-scan DECT on a conventional CT scanner. The CT imaging geometry of primary modulation is identical to that used in our previous method for scatter removal, making it possible for future combination with effective scatter correction on the same CT scanner. Methods: We insert an attenuation sheet with a spatially-varying pattern - primary modulator-between the x-ray source and the imaged object. During the CT scan, the modulator selectively hardens the x-ray beam at specific detector locations. Thus, the proposed method simultaneously acquires high and low energy data. High and low energy CT images are then reconstructed from projections with missing data via an iterative CT reconstruction algorithm with gradient weighting. Proof-of-concept studies are performed using a copper modulator on a cone-beam CT system. Results: Our preliminary results on the Catphan(c) 600 phantom indicate that the proposed method for single-scan DECT is able to successfully generate high-quality high and low energy CT images and distinguish different materials through basis material decomposition. By applying correction algorithms and using all of the acquired projection data, we can reconstruct a single CT image of comparable image quality to conventional CT images, i.e., without primary modulation. Conclusion: This work shows great promise in using a primary modulator to perform high-quality single-scan DECT imaging. Future studies will test method performance on anthropomorphic phantoms and perform quantitative analyses on image qualities and DECT decomposition accuracy. We will use simulations to optimize the modulator material and geometry parameters.

60 APPLIED LIFE SCIENCES↗