Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

TU-F-CAMPUS-T-04: Using Gold Nanoparticles to Target Mitochondria in Radiation Therapy

Purpose: The mitochondrion, like the cell nucleus, contains genetic material and plays several critical roles that determine the cell viability, including neutralization of free radicals within the cell. Studies have shown that irradiated cells with impaired mitochondria will incur more damage to the cell nucleus. This study investigates the potential use of GNPs to enhance radiation-induced damage to the organelle. Methods: The compositions of the organelles of a JURKAT cell were determined experimentally. Using Monte Carlo simulations, we investigate the significance of dose enhancement in a monoenergetic (10–50 keV and 6 MeV) x-ray irradiated cell cytoplasm, consisting of the experimentally determined composition. We also investigate the track structure of secondary electrons in the mitochondria using Geant4-DNA in the presence and absence of GNPs for incident protons and photons. The biological effect was determined using an approach based on the local effect model, assuming the mitochondrial DNA (mtDNA) was the primary target. Results: Adding 0.01% of gold to the cell cytoplasm material can cause substantial dose enhancement, dependent on the incident x-ray energy. Track structure Monte Carlo (MC) simulations show an increased number of ionization events within the mitochondrion structure. The close proximity of GNPs to the mtDNA storing nucleoid may cause the mtDNA to receive doses above ∼100 Gy for keV x-rays, leading to mitochondrial dysfunction. Conclusion: A substantial increase in ionization events can occur in the mitochondria in the presence of GNPs. If GNPs can be delivered to tumors and attached to a sufficient number of mitochondria inside the tumor cells, mitochondrial induced cell death could be a prevalent cause of cell death. The biological structures developed here will be included in the biological MC toolkit, TOPAS-nBio.

60 APPLIED LIFE SCIENCES↗

Impact of x-ray dose on the response of CR-39 to 1–5.5 MeV alphas

The CR-39 nuclear track detector is used in many nuclear diagnostics fielded at inertial confinement fusion (ICF) facilities. Large x-ray fluences generated by ICF experiments may impact the CR-39 response to incident charged particles. To determine the impact of x-ray exposure on the CR-39 response to alpha particles, a thick-target bremsstrahlung x-ray generator was used to expose CR-39 to various doses of 8 keV Cu-K{sub α} and K{sub β} x-rays. The CR-39 detectors were then exposed to 1–5.5 MeV alphas from an Am-241 source. The regions of the CR-39 exposed to x-rays showed a smaller track diameter than those not exposed to x-rays: for example, a dose of 3.0 ± 0.1 Gy causes a decrease of (19 ± 2)% in the track diameter of a 5.5 MeV alpha particle, while a dose of 60.0 ± 1.3 Gy results in a decrease of (45 ± 5)% in the track diameter. The reduced track diameters were found to be predominantly caused by a comparable reduction in the bulk etch rate of the CR-39 with x-ray dose. A residual effect depending on alpha particle energy is characterized using an empirical formula.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alignment Focus of Daily Image Guidance for Concurrent Treatment of Prostate and Pelvic Lymph Nodes

Purpose: To determine the dosimetric impact of daily imaging alignment focus on the prostate soft tissue versus the pelvic bones for the concurrent treatment of the prostate and pelvic lymph nodes (PLN) and to assess whether multileaf collimator (MLC) tracking or adaptive planning (ART) is necessary with the current clinical planning margins of 8 mm/6 mm posterior to the prostate and 5 mm to the PLN. Methods and Materials: A total of 124 kilovoltage cone-beam computed tomography (kV-CBCT) images from 6 patients were studied. For each KV-CBCT, 4 plans were retrospectively created using an isocenter shifting method with 2 different alignment focuses (prostate, PLN), an MLC shifting method, and the ART method. The selected dosimetric endpoints were compared among these plans. Results: For the isoshift contour, isoshift bone, MLC shift, and ART plans, D99 of the prostate was ≥97% of the prescription dose in 97.6%, 73.4%, 98.4%, and 96.8% of 124 fractions, respectively. Accordingly, D99 of the PLN was ≥97% of the prescription dose in 98.4%, 98.4%, 98.4%, and 100% of 124 fractions, respectively. For the rectum, D5 exceeded 105% of the planned D5 (and D5 of ART plans) in 11% (4%), 10% (2%), and 13% (5%) of 124 fractions, respectively. For the bladder, D5 exceeded 105% of the planned D5 (and D5 of ART) plans in 0% (2%), 0% (2%), and 0% (1%) of 124 fractions, respectively. Conclusion: For concurrent treatment of the prostate and PLN, with a planning margin to the prostate of 8 mm/6 mm posterior and a planning margin of 5 mm to the PLN, aligning to the prostate soft tissue can achieve adequate dose coverage to the both target volumes; aligning to the pelvic bone would result in underdosing to the prostate in one-third of fractions. With these planning margins, MLC tracking and ART methods have no dosimetric advantages.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of a Motion Tracking System During Cyberknife Robotic Radiosurgery

Cyberknife (Accuracy Inc., Ca) is a robotic radio-surgery system that includes a compact 6 MV linac delivering up to 800 cGy per minute, and an automate arm to aim at any part of the body from any angle. An essential tool is the guidance system based on x-ray imaging cameras located on supports around the patient. A Cyberknife system has been operational at the Vicenza (Italy) Hospital for years and is mainly employed for treating benign and malignant tumors, and Arterior-Venous Malformations. In radiation therapy, delivery of high doses to targets that move with respiration is challenging because of possible spatial inaccuracies. The purpose of this work was to estimate the accuracy of the prediction algorithm used to compensate for system latency in a real-time respiratory tracking system. We have analyzed respiratory signals of 30 patients who had lung or liver Cyberknife treatments. The 'Synchrony'(Accuracy Inc.) motion tracking system we use is based on the correlation between the position of LED markers, detected in real time, and the position of internal markers, sampled through x-ray imaging. The position of the external LED signals, though read in real time, must be predicted to compensate for a few hundred ms time lag in the feedback loop that redirects the beam to the current target position. The respiratory signals were described by employing their frequency power spectrum, as recently proposed by other authors. Prediction errors above 1.5 mm, lasting for periods longer than 5 seconds were observed for irregular breathers. These episodes correlate to the presence of a bimodal distribution in the power spectral density, and of very low frequencies contribution. A more refined approach would include a personalized choice of the prediction algorithm based on the very first minutes of treatment. Patient training aimed at reducing breathing irregularities might also result in improved spatial accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of large-angle production of charged pions with incident protons on cylindrical long and short targets

The HARP Collaboration has presented measurements of the double-differential {pi}{sup {+-}} production cross section in the range of momentum 100 MeV/c{<=}p{<=}800 MeV/c and angle 0.35 rad{<=}{theta}{<=}2.15 rad with proton beams hitting thin nuclear targets. In many applications the extrapolation to long targets is necessary. In this article the analysis of data taken with long (one interaction length) solid cylindrical targets made of carbon, tantalum, and lead is presented. The data were taken with the large-acceptance HARP detector in the T9 beam line of the CERN proton synchrotron. The secondary pions were produced by beams of protons with momenta of 5, 8, and 12GeV/c. The tracking and identification of the produced particles were performed using a small-radius cylindrical time projection chamber placed inside a solenoidal magnet. Incident protons were identified by an elaborate system of beam detectors. Results are obtained for the double-differential yields per target nucleon d{sup 2}{sigma}/dpd{theta}. The measurements are compared with predictions of the MARS and GEANT4 Monte Carlo simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The TREK/E36 experiment at J-PARC

Experiment E36 is planned to run at the J-PARC K1.1BR kaon beamline in 2014-15 using a stopped kaon beam along with the TREK target and detector setup. The decay products of stopped positive kaons will be observed with a large-acceptance toroidal spectrometer capable of tracking charged particles with high resolution, combined with a photon calorimeter with large solid angle and redundant particle identification systems. With the aim to test lepton universality in the K{sub e2}/K{sub μ2} ratio with high precision, the experiment is highly sensitive to new physics beyond the Standard Model. A further goal of E36 is to search for a heavy sterile neutrino in two-body kaon decay, along with additional searches for exotic decay modes including the possibility to produce a dark photon and to observe its decay into an e{sup +}e{sup −} pair. An overview of the planned measurements with E36 will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Next-Generation Countermeasure Architecture to Prevent Explosives Attacks at Large Public Events

A concept has been developed for a next-generation integrated countermeasure architecture to detect improvised explosive devices hidden on people or left behind in unstructured crowds. The work is part of the Standoff Technology Integration and Demonstration Program of the U.S. Department of Homeland Security’s Science and Technology Directorate. The architecture is based on results from an initial design tested in crowd conditions and a broad survey of existing and emerging technologies. The architecture uses a layered-defense approach that automates screening operations and prioritizes threats and mobilizes resources accordingly. A system tracks people as they move, integrating sensors to optimize threat identification accuracy and screening resources. A threat-based decision module prioritizes screening targets based on user-defined rules. Operators manage system-wide risk and mobilize field teams for interdiction. DHS is working with industry on technology development and testing to achieve the required level of system integration and economics in crowd conditions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Design, performance, and field operation of twisting heliostats for 3,000-sun concentration and high temperature

The idea is to combine the solar energy reflected from a field of many heliostats to obtain a single focus of high concentration and high power. We exploit a new type of “twisting” heliostat” in which as the mount is moved to track the sun through the day, the reflector shape is twisted to maintain a focused image of the sun’s disc on the target, through the day over a wide range of angles of incidence. By combining the light reflected by many twisting heliostats into a single focus, we are not only able to accomplish but also maintain very high concentration and temperature through the day, with higher efficiency than has previously been possible with conventional heliostats having a fixed shape. A circular field of twisting heliostats is used to power a single intense focus atop a central tower. The light from all the heliostats is relayed to an upward facing receiver at the focus via a central Cassegrain secondary reflector located above the receiver. In a specific design targeting 1 MW of power, a 100 m diameter field arrays 431 twisting heliostats, each with a 7 m2 reflector. The secondary reflector ,7.2 m in diameter, is located 24 m above the heliostat field, bringing sunlight with annual average power of 1 MW to a circular focus 0.8 m in diameter, at a concentration averaging 3,000 suns.

14 SOLAR ENERGY↗

DNA Extraction by Isotachophoresis in a Microfluidic Channel

Biological assays have many applications. For example, forensics personnel and medical professionals use these tests to diagnose diseases and track their progression or identify pathogens and the host response to them. One limitation of these tests, however, is that most of them target only one piece of the sample - such as bacterial DNA - and other components (e.g. host genomic DNA) get in the way, even though they may be useful for different tests. To address this problem, it would be useful to extract several different substances from a complex biological sample - such as blood - in an inexpensive and efficient manner. This summer, I worked with Maxim Shusteff at Lawrence Livermore National Lab on the Rapid Automated Sample Prep project. The goal of the project is to solve the aforementioned problem by creating a system that uses a series of different extraction methods to extract cells, bacteria, and DNA from a complex biological sample. Biological assays can then be run on purified output samples. In this device, an operator could input a complex sample such as blood or saliva, and would receive separate outputs of cells, bacteria, viruses, and DNA. I had the opportunity to work this summer with isotachophoresis (ITP), a technique that can be used to extract nucleic acids from a sample. This technique is intended to be the last stage of the purification device. Isotachophoresis separates particles based on different electrophoretic mobilities. This technique is convenient for out application because free solution DNA mobility is approximately equal for DNA longer than 300 base pairs in length. The sample of interest - in our case DNA - is fed into the chip with streams of leading electrolyte (LE) and trailing electrolyte (TE). When an electric field is applied, the species migrate based on their electrophoretic mobilities. Because the ions in the leading electrolyte have a high electrophoretic mobility, they race ahead of the slower sample and trailing electrolyte ions. Conversely, the trailing electrolyte ions have a slow electrophoretic mobility, so they lag behind the sample, thus trapping the species of interest between the LE and TE streams. In a typical isotachophoresis configuration, the electric field is applied in a direction parallel to the direction of flow. The species then form bands that stretch across the width of the channel. A major limitation of that approach is that only a finite amount of sample can be processed at once, and the sample must be processed in batches. For our purposes, a form of free-flow isotachophoresis is more convenient, where the DNA forms a band parallel to the edges of the channel. To achieve this, in our chip, the electric field is applied transversely. This creates a force perpendicular to the direction of flow, which causes the different ions to migrate across the flow direction. Because the mobility of the DNA is between the mobility of the leading and the trailing electrolyte, the DNA is focused in a tight band near the center of the channel. The stream of DNA can then be directed to a different output to produce a highly concentrated outlet stream without batch processing. One hurdle that must be overcome for successful ITP is isolating the electrochemical reactions that result from the application of high voltage for the actual process of isotachophoresis. The electrochemical reactions that occur around metal electrodes produce bubbles and pH changes that are detrimental to successful ITP. The design of the chips we use incorporates polyacrylamide gels to serve as electrodes along the central channel. For our design, the metal electrodes are located away from the chip, and high conductivity buffer streams carry the potential to the chip, functioning as a 'liquid electrode.' The stream then runs alongside a gel barrier. The gel electrode permits ion transfer while simultaneously isolating the separation chamber from any contaminants in the outer, 'liquid electrode' streams. The difference in potential from one side of the chip to the other creates an electric field. This field traverses the inner, separation channel, containing the leading electrolyte, the trailing electrolyte, and the sample of interest (DNA). To increase the ease of use of the chips, a newer chip design has been fabricated. This design has wire electrodes integrated on the chip, rather than elsewhere. To keep the pH changes and bubbling isolated from the separation channel, the chip contains deeper wells near the electrodes so that the flowing buffer can wash away any gases that form around the electrode. This design is significantly more compact because it eliminates the cumbersome electrode boxes. Eliminating the electrode boxes also decreases the required voltage, making the experiments safer. This happens because when the 'liquid electrode' streams travel through small diameter tubing, they lose much of their voltage due to the electrical resistance of the fluid in the tubing.

42 ENGINEERING↗

Horn Location Sensors (HLS) for LBNF

The Long-Baseline Neutrino Facility (LBNF) will deliver the world's most powerful muon neutrino beam to the Deep Underground Neutrino Experiment (DUNE), initially operating at 1.2 MW and upgradeable to 2.4 MW. Ensuring the accurate direction of this beam is critical for DUNE's precision goals. This talk introduces the Horn Location Sensors (HLS) system, designed to provide precise, relative measurements of the focusing horns, targets, and beam position monitors in the neutrino beamline. The HLS system employs high-precision FSI-based hydrostatic leveling sensors to track vertical motion and tilt, achieving precision on the order of 0.1 mm. Built for minimal maintenance in radioactive environments, the HLS system ensures precise alignment of beamline components during high-power operations. This system is essential for maintaining beam accuracy and enhancing DUNE's scientific performance.

43 PARTICLE ACCELERATORS↗

Data-based and secure switched cyber–physical systems

In this work, we develop a completely model-free moving target defense framework for the detection and mitigation of sensor and/or actuator attacks in cyber–physical systems with dynamics that evolve in discrete-time. We incorporate an intrusion detection mechanism based on an approximate dynamic programming technique that learns the policies for optimal regulation and optimal tracking while simultaneously defending against actuator and sensor attacks in a model-free fashion. Switching rules are leveraged to force proactive and reactive defense mechanisms as well as, guarantee the stability of the equilibrium point. Finally, as a case study, we apply the proposed moving target defense framework to a DC–DC converter that is used in electric vehicles.

42 ENGINEERING↗

Expected tracking performance of the ATLAS Inner Tracker at the High-Luminosity LHC

The high-luminosity phase of LHC operations (HL-LHC), will feature a large increase in simultaneous proton-proton interactions per bunch crossing up to 200, compared with a typical leveling target of 64 in Run 3. Such an increase will create a very challenging environment in which to perform charged particle trajectory reconstruction, a task crucial for the success of the ATLAS physics program, and will exceed the capabilities of the current ATLAS Inner Detector (ID). A new all-silicon Inner Tracker (ITk) will replace the current ID in time for the start of the HL-LHC. To ensure successful use of the ITk capabilities in Run 4 and beyond, the ATLAS tracking software has been successfully adapted to achieve state-of-the-art track reconstruction in challenging high-luminosity conditions with the ITk detector. This paper presents the expected tracking performance of the ATLAS ITk based on the latest available developments since the ITk technical design reports.

47 OTHER INSTRUMENTATION↗

Measurement of the Negative Pion and Positive Kaon Total Hadronic Cross Sections on Argon at the LArIAT Experiment

The Liquid Argon Time Projection Chamber (LArTPC) represents one of the most advanced experimental technologies for physics at the Intensity Frontier due to its full 3D-imaging, excellent particle identication and precise calorimetric energy reconstruction. By deploying a LArTPC in a dedicated calibration test beam line at Fermilab, LArIAT (Liquid Argon In A Testbeam) aims to experimentally calibrate this technology in a controlled environment and to provide physics results key to the neutrino oscillation physics and proton decay searches of the Short Baseline Neutrino (SBND, MicroBooNE, ICARUS) and Long Baseline Neutrino programs (DUNE). LArIAT's physics program entails a vast set of topics with a particular focus on the study of nuclear eects such as pion and kaon characteristic interaction modes. This thesis presents two measurements performed for the rst time: the measure- ment of the negative pion total hadronic cross section on argon in the 100-1050 MeV kinetic energy range and the measurement of the positive kaon total hadronic cross section on argon in the 100-650 MeV kinetic energy range. The analyses devised for these measurements use both the core elements of LArIAT: beamline and LArTPC. The rst step in each analysis is the development of an event selection based on beam- line and TPC information geared towards the identication of the hadron of interest. We then proceed to match the beamline candidate to a suitable TPC track. Finally, we apply the \thin slice method" technique and measure the cross section, correcting for background contamination and detector eects. The thin slice technique is a new method to measure hadron-argon cross sections possible only due to the combination of the tracking and calorimetry capability of the LArTPC technology. Albeit never on argon, the hadronic cross section of pions has been extensively measured before on lighter and heavier dierent elements in thin target experiments, leading to solid predictions for measurements on argon. Through the use of a dierent technique, our measurement of the negative pion total hadronic cross section on argon is in general agreement with the predictions by the Geant4 Bertini Cascade model which are based on data from thin target experiments. On the contrary, cross section measurements for kaons are extremely scarce, thus more dicult to model. Our measurement of the positive kaon total hadronic cross section on argon is mostly in tension with the Geant4 prediction over the explored range of energies and provides new experimental data to properly compare existing interaction models. This thesis also reports two ancillary detector physics measurements necessary for the cross section analyses: the measurements of the LArIAT electric eld and calorimetry constants. We developed a technique to measure the LArIAT electric eld using cathode-anode piercing tracks with cosmic data. We applied a new technique for the measurement of the calorimetry calibration constants based on the particles' momentum measurement. The negative pion and the positive kaon total hadronic cross measurements are the rst physics results of the LArIAT experiment and will be the basis for the future LArIAT measurements of pion and kaon cross sections in the exclusive channels. The outcome of these measurements will ultimately enable to quantify and reduce the systematic associated with the hadronic interaction models in neutrino-argon interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TH-AB-202-06: BEST IN PHYSICS (JOINT IMAGING-THERAPY): A Real-Time Tumor Tracking Using Novel Scatter Imaging Modality During Lung SBRT

Purpose: Compared to traditional radiotherapy techniques, stereotactic body radiation therapy (SBRT) provides more favorable outcomes during the treatment of certain lung tumors. Despite advancements in image guidance, accurate target localization still remains a challenge. In this work, we expand our knowledge of a novel scatter imaging modality in order to develop a real-time tumor localization method using scattered photons from the patient during treatment. Methods: Images of the QUASAR™ Respiratory Motion Phantom were taken by irradiating it on a Varian TrueBeam accelerator. The scattered radiation was detected using a flat panel-based pinhole camera detection system. Two motion settings were investigated: static and dynamic. In the former, the lung tumor was manually shifted between imaging. In the latter, the lung tumor was set to move at a certain frequency and amplitude while the images were acquired continuously for one minute. The accuracy of tumor localization and the irradiation time required to distinguish the lung tumor were studied. Results: The comparison of measured and expected location of the lung tumor during static motion was shown to be under standard deviation (STD) of 0.064 with a mean STD of 0.031cm. The dynamic motion was taken at a rate of 1400 MU/min for one minute and the measured location of the lung tumor was then compared with the QUASAR phantom’s sinusoidal motion pattern and the agreement found to be at an average STD of 0.275cm. The location of the lung tumor was investigated using aggregate images consisting of 1 or 2 frames/image and the change was below STD of 0.30cm. The lung tumor also appeared to be blurrier in images consisting of two frames. Conclusion: Based on our preliminary results real-time image guidance using the scatter imaging modality to localize and track tumors during lung SBRT has the potential to become clinical reality.

60 APPLIED LIFE SCIENCES↗

Searching for long-lived particles beyond the Standard Model at the Large Hadron Collider

Particles beyond the Standard Model (SM) can generically have lifetimes that are long compared to SM particles at the weak scale. When produced at experiments such as the Large Hadron Collider (LHC) at CERN, these long-lived particles (LLPs) can decay far from the interaction vertex of the primary proton–proton collision. Such LLP signatures are distinct from those of promptly decaying particles that are targeted by the majority of searches for new physics at the LHC, often requiring customized techniques to identify, for example, significantly displaced decay vertices, tracks with atypical properties, and short track segments. Given their non-standard nature, a comprehensive overview of LLP signatures at the LHC is beneficial to ensure that possible avenues of the discovery of new physics are not overlooked. Here we report on the joint work of a community of theorists and experimentalists with the ATLAS, CMS, and LHCb experiments—as well as those working on dedicated experiments such as MoEDAL, milliQan, MATHUSLA, CODEX-b, and FASER—to survey the current state of LLP searches at the LHC, and to chart a path for the development of LLP searches into the future, both in the upcoming Run 3 and at the high-luminosity LHC. The work is organized around the current and future potential capabilities of LHC experiments to generally discover new LLPs, and takes a signature-based approach to surveying classes of models that give rise to LLPs rather than emphasizing any particular theory motivation. We develop a set of simplified models; assess the coverage of current searches; document known, often unexpected backgrounds; explore the capabilities of proposed detector upgrades; provide recommendations for the presentation of search results; and look towards the newest frontiers, namely high-multiplicity 'dark showers', highlighting opportunities for expanding the LHC reach for these signals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-194: Continuous Patient Surface Monitoring and Motion Analysis During Lung SBRT

Purpose: Continuous monitoring of the SBRT lung patient motion during delivery is critical for ensuring adequate target volume margins in stereotactic body radiotherapy (SBRT). This work assesses the deviation of the patient surface motion using a real-time surface tracking system throughout treatment delivery. Methods: Our SBRT protocol employs abdominal compression to reduce the diaphragm movement to within 1 cm, and this is confirmed daily with fluoroscopy. Most patients are prescribed 3–5 fractions, and on treatment day a repeat motion analysis with fluoroscopy is performed, followed by a kV CBCT is aligned with the original planning CT image for 3D setup confirmation. During this entire process a patient surface data restricted to whole chest or the sternum at the middle of the breathing cycle was captured using AlignRT optical surface tracking system and defined as a reference surface. For 10 patients, the deviation of the patient position from the reference surface was recorded during the SBRT delivery in the anterior-posterior (AP) direction at 3–6 measurements per second. Results: On average, the patient position deviated from the reference surface more than 4 mm, 3 mm and 2 mm in the AP direction for 0.95%, 3.7% and 11.1% of the total treatment time, respectively. Only one of the 10 patients showed that the maximum deviation of the patient surface during the SBRT delivery was greater than 1 cm. The average deviation of the patient surface from the reference surface during the SBRT delivery was not greater than 1.6 mm for any patient. Conclusion: This investigation indicates that AP motion can be significant even though the frequency is low. Continuous monitoring during SBRT has demonstrated value in monitoring patient motion ensuring that margins selected for SBRT are appropriate, and the use of non-ionizing and high-frequency imaging can provide useful indicators of motion during treatment.

60 APPLIED LIFE SCIENCES↗

Development of a pattern recognition algorithm for reconstructing multi-particle events in the Mu2e detector

Mu2e is an upcoming experiment at Fermilab and its main goal is to search for the Charged Lepton Flavor Violation (CLFV) in the coherent transition of a muon into an electron on an Al target. In Mu2e, multi-particle events can occur simultaneously within the same time region and it is crucial to accurately identify each particle track, including signals, to improve the robustness of track finding methods and enhance reconstruction efficiency. ¯p annihilation is one of the background events and produces multiple particles that can mimic signal events. Additionally, photons from radiative pion captures can produce a γ → $e+e−$ pair, which can be used to calibrate the Mu2e momentum scale and the resolution. The Mu2e track reconstruction sequence begins by grouping hits produced in the tracker based on time and z coordinate information, called TimeCluster, and selected hits are processed to reconstruct helices and determine their momentum. The current pattern recognition algorithms identify a single helix per TimeCluster for single track events. A new pattern recognition algorithm is being developed to reconstruct multi-particle events and its features for finding multiple tracks and the current evaluation results are reported.

Kitagawa, H. [Pisa U.]↗

Neutron Radiation, Radiation Measurement and the JLab APEX Experiment

The A-prime Experiment (APEX), which is approved to run at the Thomas Jefferson Accelerator Facility (JLab) Hall A, will search for a new vector boson that is hypothesized to be a possible force carrier that couples to dark matter. APEX results should be sensitive to the mass range of 65 MeV to 550 MeV, and high sensitivity will be achieved by means of a high intensity 100 muA beam on a 0.3 g/cm 2 Tungsten target resulting in very high luminosity. The experiment should be able to observe an A-prime with a coupling constant 1 x 10 7 times smaller than the electromagnetic coupling constant. To deal safely with such enormous intensity and luminosity, a full radiation analysis must be used. A Geant4 Monte Carlo simulation was performed to study the radiation environments expected in the JLab Hall A during the APEX experiment. We benchmarked our simulations with measurements carried out during past experiments such as the Pb Radius Experiment (PREX-I). Our PREX-I simulations agreed reasonably well with measurements performed by measuring the change in dark current in a Silicon Photomultipliers as a means of radiation damage. However, our simulations were initially significantly higher than the neutron dose measurements (using NP100) in Hall A. The apparent disagreement hints to several potential problems in NP100 measurements including the dead-time. Further, we identified radiation sources in the beam line and tested several shielding strategies to lower the radiation in Hall A. We characterized several thermal neutron detectors and also studied possibility of damage to electronics due to neutron radiation. We successfully demonstrated that the APEX experiment can be carried out in JLab Hall A without worrying about radiation damage to expensive electronics. The A-prime will appear as a narrow resonance in the invariant mass spectrum of e + e - pairs resulting from the electron beam scattering off the APEX target. In this search for the A-prime, it is critical to have a good mass resolution which is mainly dominated by the track measurement uncertainties. We studied a novel method to calibrate the HRS optics which will improve the accuracy of track measurements. Our results will be used to design HRS calibration runs for the APEX experiment.

Kaluarachchi, Maduka↗