Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TANK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Applying Hanford Tank Mixing Data to Define Pulse Jet Mixer Operation

Pulse jet mixed (PJM) process vessels are being developed for storing, blending, and chemical processing of nuclear waste slurries at the Waste Treatment and Immobilization Plant (WTP) to be built at Hanford, Washington. These waste slurries exhibit variable process feed characteristics including Newtonian to non-Newtonian rheologies over a range of solids loadings. Waste feed to the WTP from the Hanford Tank Farms will be accomplished via the Waste Feed Delivery (WFD) system which includes million-gallon underground storage double-shell tanks (DSTs) with dual-opposed jet mixer pumps. Experience using WFD type jet mixer pumps to mobilize actual Hanford waste in DSTs may be used to establish design threshold criteria of interest to pulse jet mixed process vessel operation. This paper describes a method to evaluate the pulse jet mixed vessel capability to process waste based on information obtained during mobilizing and suspending waste by the WFD system jet mixer pumps in a DST. Calculations of jet velocity and wall shear stress in a specific pulse jet mixed process vessel were performed using a commercial computational fluid dynamics (CFD) code. The CFD-modelled process vessel consists of a 4.9-m- (16-ft-) diameter tank with a 2:1 semi-elliptical head, a single, 10-cm (4-in.) downward facing 60-degree conical nozzle, and a 0.61-m (24-in.) inside diameter PJM. The PJM is located at 70% of the vessel radius with the nozzle stand-off-distance 14 cm (6 in.) above the vessel head. The CFD modeled fluid velocity and wall shear stress can be used to estimate vessel waste-processing performance by comparison to available actual WFD system process data. Test data from the operation of jet mixer pumps in the 23-m (75-ft) diameter DSTs have demonstrated mobilization, solid particles in a sediment matrix were moved from their initial location, and suspension, mobilized solid particles were moved to a higher elevation in the vessel than their initial location, of waste solids. Jet mixer pumps were used in Hanford waste tank 241-AZ-101, and at least 95% of the 0.46-m (18-in.) deep sediment, with a shear strength of 1,500 to 4,200 Pa, was mobilized. Solids with a median particle size of 43 μm, 90th percentile of 94μm, were suspended in tank 241-AZ-101 to at least 5.5 m (216 in.) above the vessel bottom. Analytical calculations for this jet mixer pump test were used to estimate the velocities and wall shear stress that mobilized and suspended the waste. These velocities and wall shear stresses provide design threshold criteria which are metrics for system performance that can be evaluated via testing. If the fluid motion in a specific pulse jet mixed process vessel meets or exceeds the fluid motion of the demonstrated performance in the WFD system, confidence is provided that that vessel will similarly mobilize and suspend those solids if they were within the WTP. The single PJM CFD-calculated jet velocity and wall shear stress compare favorably with the design threshold criterion estimated for the tank 241-AZ-101 process data. Therefore, for both mobilization and suspension, the performance data evaluated from the WFD system testing increases confidence that the performance of the pulse jet mixed process vessels will be sufficient to process that waste even if that waste is not fully characterized.

mixing' slurry↗

RESULTS FOR THE FOURTH QUARTER 2010 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

This report details the chemical and radionuclide contaminant results for the characterization of the 2010 Fourth Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section. (2) The reported detection limits for {sup 94}Nb, {sup 247}Cm and {sup 249}Cf are above the requested limits from Reference 2. However, they are below the limits established in Reference 3. (3) There is an estimated concentration of trimethylbenzene (2.25 mg/L). This is not a WAC analyte, but it is the first time this organic compound has been detected in a quarterly WAC sample from Tank 50. (4) The reported detection limit for Norpar 13 is greater than the limit from Table 4 and Attachment 8.2 of the WAC. (5) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC. (6) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of the analytes in Tank 50.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the Fourth Quarter Calendar Year 2015 Tank 50H Salt Solution Sample

In this memorandum, the chemical and radionuclide contaminant results from the Fourth Quarter Calendar Year 2015 (CY15) sample of Tank 50H salt solution are presented in tabulated form. The Fourth Quarter CY15 Tank 50H samples were obtained on October 29, 2015 and received at Savannah River National Laboratory (SRNL) on October 30, 2015. The information from this characterization will be used by Defense Waste Processing Facility (DWPF) & Saltstone Facility Engineering for the transfer of aqueous waste from Tank 50H to the Salt Feed Tank in the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the Task Technical and Quality Assurance Plan (TTQAP) for the Tank 50H saltstone task. The chemical and radionuclide contaminant results from the characterization of the Fourth Quarter Calendar Year 2015 (CY15) sampling of Tank 50H were requested by SRR personnel and details of the testing are presented in the SRNL Task Technical and Quality Assurance Plan.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107

The Low-Activity Waste Pretreatment System (LAWPS) provides for the early production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility for immobilization. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 (hereafter called AP-107) be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange) then vitrified. A small-scale test platform to demonstrate the solids filtration, Cs removal, and LAW vitrification was constructed and installed at the Pacific Northwest National Laboratory. Bench-scale ion exchange testing with approximately 9 L of AP-107 supernate was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Batch 2081000057). The ion exchange media was first tested with simulant and was previously described. This report describes the Cs ion exchange batch contact and column test results with the AP-107 tank waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

332TFAD04 Tank Closure Plan

Enclosed is the 332TFAD04 Aboveground Tank Closure/Removal Plan for a tank regulated under Spill Prevention, Controls, and Countermeasures (SPCC) and Aboveground Petroleum Storage Act (APSA) regulations. This tank held diesel fuel for an emergency generator at Building 332. The generator is being replaced with a new unit that contains a belly tank, therefore this aboveground tank will no longer be in use and is being removed. The tank will be SPCC permanently closed on June 2, 2020.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream: Volume 2 Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life.[2-5] The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. Volume 1 of this report summarizes data analysis of APR and PAPR cartridge testing on vapors from the AP tank farm exhauster. Previous testing of APR cartridges was conducted on the AP exhauster in June 2016. However, an AP exhauster upgrade was completed in September 2016. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the new AP exhauster source, along with two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota). Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

61 RADIATION PROTECTION AND DOSIMETRY↗

Tank-Integrated Heat Exchanger for Boil-Off Reduction

The following document details the initial efforts of the Protium Company in developing reduced boil-off and zero boil-off liquid hydrogen tanks using Vapor-Cooled Shielding (VCS) technology. The intention is to improve upon the performance characteristics of traditional vacuum-jacketed dewars by reducing boil-off rate, cooldown time, and total boil-off during cooldown time while integrating the heat exchanger into the wall of the VCS tank. The work carried out during this project was limited, as the grant recipient The Protium Company was acquired by Plug Power Inc. on October 1st 2021, early in the performance period of the grant. As such, the extent of the work completed includes an initial estimation of the dimensions needed for a 0.1%/day boil-off VCS liquid hydrogen tank. These dimensions are derived from data gathered from sizes of previous VCS tanks. The dimensions and estimated boil-off rate for the VCS tank are by no means validated, and no design was generated for a zero boil-off tank.

08 HYDROGEN↗

Measurement of Iodine, Iodide, and Iodate in Hanford Tank Waste: Technology Transfer from PNNL to Hanford 222-S Laboratory

This report summarizes the measurement of the inorganic chemical forms of iodine in Hanford tank waste. The Hanford tank wastes have roughly a part per million iodine. Part of the iodine is the long-lived beta emitter 129I, and the rest is stable 127I. Because tank waste iodine is radioactive and radiotoxic, its chemical form must be known so that its behavior in the vitrification process can be reliably known and anticipated in various waste streams (glass, secondary liquid and solid waste, and offgas emissions) at Hanford. Iodine in tank wastes exists in the inorganic chemical forms iodide and iodate (and possibly also periodate) and also as organic forms such as alkyl iodides. The measurement of organic iodides is very different from the measurement of inorganic forms and is outside the scope of this report. The inorganic chemical forms are chemically separated, in sequence, from the raw tank waste using solvent extractions and several redox reactions, then measured by ICP-MS. The inorganic chemical forms of iodine are chemically reactive, and so is the tank waste. The chemistry must be carefully designed to avoid unintended reactions that could convert one form of iodine to another during the analysis, which would skew the data and report iodine in the wrong chemical form. This iodine analysis, developed at PNNL, is being transferred to the DOE 222-S Laboratory on the Hanford Site, in Washington State, for implementation during waste processing operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sludge Batch 11 Assembly: Tank 13

Savannah River Mission Completion Nuclear Safety and Engineering Integration (SRMC-E) has requested that Savannah River National Laboratory (SRNL) perform Tank 13 characterization analyses in support of Sludge Batch 11 (SB11) assembly. This report provides important characterization of the slurry in Tank 13 (also containing transferred Tank 15 heel sludge) prior to transfer from Tank 13 to Tank 51 in order to demonstrate that the transfer is "Low Rem" and ensure the sludge concurs with the estimated transfer mass for the SB11 recipe. One Tank 13 sample was delivered to SRNL in October 2023. The sample was analyzed for density, weight percent solids, and total alpha.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Strontium Speciation in Relevant Tank Waste Components Examined by Electrospray Ionization Mass Spectrometry

The identification of chemical species formed in complex nuclear waste is crucial for the development and employment of advanced separations technologies to remediate the Hanford site by processing tank waste. The current Tank Side Cesium Removal (TSCR) process deployed at Hanford utilizes crystalline silicotitanate (CST) ion exchange (IX) media to aid in the separation of low-activity waste for proper treatment and disposal. The inorganic IX media is highly selective for Cs but has been shown to also remove Sr from caustic simulants and small-scale IX processing of Hanford tank waste.(Fiskum, Rovira et al. 2019, Fiskum, Campbell et al. 2021, Westesen, Campbell et al. 2022) Quantitative Sr removal has not been observed in all tank waste supernates tested; thus, to better understand Sr removal and effectively predict processing behavior through TSCR, it is necessary to first investigate Sr speciation in tank waste. This work utilized electrospray ionization mass spectrometry (ESI-MS) to identify ionic Sr complexes that form in the presence of NO 3 –, NO 2 –, OH–, and Cl–. Although our results show that NO 3 –, NO 2 –, and OH– are competitive for Sr 2+ binding, previous data from IX studies indicate that [SrOH] + is not the dominant species of concern in tank waste processing schemes.(Fiskum, Campbell and Trang-Le 2020) Our results show that the [Sr(NO3)]+ species and the [Sr(NO2)] + species form in considerable abundances, which may affect the ability to separate Sr using CST in nuclear waste separation processes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Control Selection for the Neutralization Tank in the Aqueous Recovery System at SRPPF

• Neutralization and solidification is the last step in the Aqueous Recovery Process • All waste streams are acidic and must be neutralized before being combined with grout in a solidification drum • The neutralization tank is a 250 L, 24” diameter, 45” high tank • The batch tank is a 125 L tank • The solidification drum is a 55-gallon drum, pre-filled with grout & a sacrificial mixing paddle • Normal mass in neutralization tank: 50 g Pu • Normal mass in batch tank or drum: 25 g Pu

Dressman, Phillip M. [Savannah River Nuclear Solut↗

DETERMINATION OF THE FRACTION OF GIBBSITE AND BOEHMITE FORMS OF ALUMINUM IN TANK 51H SLUDGE

The Savannah River National Laboratory (SRNL) was tasked with developing a test to determine the fraction of the gibbsite and boehmite forms of aluminum in the sludge solids. Knowledge of the fractions of gibbsite and boehmite in the sludge contained in various waste tanks would facilitate better sludge mass reduction estimates and allow better planning/scheduling for sludge batch preparation. The composite sludge sample prepared for use in the test from several small samples remaining from the original 3-L sample appears to be representative of the original sample based on the characterization data. A Gibbsite/Boehmite Test was developed that uses 8 M NaOH and a temperature of 65 C to dissolve aluminum. The soluble aluminum concentration data collected during the test indicates that, for the three standards containing gibbsite, all of the gibbsite dissolved in approximately 2 hours. Under the test conditions boehmite dissolved at more than an order of magnitude more slowly than gibbsite. An estimate based on the soluble aluminum concentration from the sludge sample at two hours into the test indicates the sludge solids contain a form of aluminum that dissolves at a rate similar to the 100% Boehmite standard. Combined with the XRD data from the original 3-L sample, these results provide substantial evidence that the boehmite form of aluminum predominates in the sludge. A calculation from the results of the Gibbsite/Boehmite test indicates the sludge contains {approx}3% gibbsite and {approx}97% boehmite. The sludge waste in Tank 51H was recently treated under Low Temperature Aluminum Dissolution (LTAD) conditions and a substantial fraction of aluminum (i.e., sludge mass) was removed, avoiding production of over 100 glass canisters in Defense Waste Processing Facility (DWPF). Results of the Gibbsite/Boehmite test indicate that the aluminum in this sludge was in the form of the more difficult to dissolve boehmite form of aluminum. Since boehmite may be the dominant form of aluminum in Savannah River Site (SRS) waste tank sludge, this result suggests that the conditions of the LTAD process can be used to dissolve both the gibbsite and boehmite forms of aluminum in tank sludge and costly tank infrastructure upgrades required for the higher temperature baseline process can be avoided. However, this conclusion should be confirmed by testing additional waste tank samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Ultrasonic Measurement Variation in the Double-Shell Tank Integrity Project

Washington River Protection Solutions (WRPS) under contract from the U.S. Department of Energy (DOE) is responsible for assessing the condition of the double-shell tanks (DST) on the Hanford nuclear site. WRPS has contracted with AREVA Federal Services LLC (AFS) to perform ultrasonic testing (UT) inspections of the 28 DSTs to assess the condition of the tanks, judge the effects of past corrosion control practices, and satisfy a regulatory requirement to periodically assess the integrity of the tanks. Since measurement inception in 1997, nine waste tanks have been examined twice (at the time of this report) providing UT data that can now be compared over specific areas. During initial reviews of these two comparable data sets, average UT wall-thickness measurement reductions were noted in most of the tanks. This variation could be a result of actual wall thinning occurring on the waste-tanks walls, or some other unexplained anomaly resulting from measurement error due to causes such as the then-current measurement procedures, operator setup, or equipment differences. WRPS contracted with the Pacific Northwest National Laboratory (PNNL) to assist in understanding why this variation exists and where it stems from.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of lightweight designs and materials for LO2 and LH2 propellant tanks for space vehicles, phase 1

Design, analysis, and fabrication studies were performed on nonintegral (suspended) tanks using a representative space tug design. The LH2 and LO2 tank concept selection was developed. Tank geometries and support relationships were investigated using tug design propellant inertias and ullage pressures, then compared based on total tug systems effects. The tank combinations which resulted in the maximum payload were selected. Tests were conducted on samples of membrane material which was processed in a manner simulating production tank fabrication operations to determine fabrication effects on the fracture toughness of the tank material. Fracture mechanics analyses were also performed to establish a preliminary set of allowables for initial defects.

Source record↗

Welding of the external tank of the Space Shuttle

Welding processes and assembly techniques used in the fabrication of the external tank of the Space Shuttle are discussed. Each external tank consists of one liquid oxygen tank and one liquid hydrogen tank connected by an intertank skirt which is mechanically assembled; the fabrication of the external tank pressure vessel involves about 36,000 linear inches of weld required to join 138 pieces of 2219 aluminum. The discussion includes several innovations, such as building domes using the 1/4 panel assembly technique, which have been used in the fabrication of the tank.

Clover, F. R., Jr.↗

Space Shuttle with rail system and aft thrust structure securing solid rocket boosters to external tank

The configuration and relationship of the external propellant tank and solid rocket boosters of space transportation systems such as the space shuttle are described. The space shuttle system with the improved propellant tank is shown. The external tank has a forward pressure vessel for liquid hydrogen and an aft pressure vessel for liquid oxygen. The solid rocket boosters are joined together by a thrust frame which extends across and behind the external tank. The thrust of the orbiter's main rocket engines are transmitted to the aft portion of the external tank and the thrust of the solid rocket boosters are transmitted to the aft end of the external tank.

Vonpragenau, G. L.↗

An analytical study of reusable flight-weight cryogenic propellant tank designs

Thermostructural analyses of reusable flight-weight cryogenic tanks for a vertically launched space vehicle have been conducted. An analytical procedure was developed for sizing the tank structure, cryogenic insulation, and thermal protection system. Unstiffened, integrally-stiffened, and honeycomb core sandwich tank skins using aluminum or stainless steel materials were compared for their ability to meet design criteria at least weight. Cryogenic insulation systems were also evaluated, including closed-cell cryogenic foams and evacuated honeycomb core. The results indicate that a 400 F foam-insulated unstiffened-skin aluminum tank structure is the lightest structure for either LOX or LH2 tanks that meet the selected design criteria, but only two to four percent lighter than a stiffened aluminum tank.

Taylor, A. H.↗