Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spares”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Capability to Recover Plutonium-238 in H-Canyon/HB-Line - 13248

Plutonium-238 is used in Radioisotope Thermoelectric Generators (RTGs) to generate electrical power and in Radioisotope Heater Units (RHUs) to produce heat for electronics and environmental control for deep space missions. The domestic supply of Pu-238 consists of scrap material from previous mission production or material purchased from Russia. Currently, the United States has no significant production scale operational capability to produce and separate new Pu-238 from irradiated neptunium-237 targets. The Department of Energy - Nuclear Energy is currently evaluating and developing plans to reconstitute the United States capability to produce Pu-238 from irradiated Np-237 targets. The Savannah River Site had previously produced and/or processed all the Pu-238 utilized in Radioisotope Thermoelectric Generators (RTGs) for deep space missions up to and including the majority of the plutonium for the Cassini Mission. The previous full production cycle capabilities included: Np- 237 target fabrication, target irradiation, target dissolution and Np-237 and Pu-238 separation and purification, conversion of Np-237 and Pu-238 to oxide, scrap recovery, and Pu-238 encapsulation. The capability and equipment still exist and could be revitalized or put back into service to recover and purify Pu-238/Np-237 or broken General Purpose Heat Source (GPHS) pellets utilizing existing process equipment in HB-Line Scrap Recovery, and H-Canyon Frame Waste Recovery processes. The conversion of Np-237 and Pu-238 to oxide can be performed in the existing HB-Line Phase-2 and Phase- 3 Processes. Dissolution of irradiated Np-237 target material, and separation and purification of Np-237 and Pu-238 product streams would be possible at production rates of ∼2 kg/month of Pu-238 if the existing H-Canyon Frames Process spare equipment were re-installed. Previously, the primary H-Canyon Frames equipment was removed to be replaced: however, the replacement project was stopped. The spare equipment is stored and still available for installation. Out of specification Pu-238 scrap material can be purified and recovered by utilizing the HB-Line Phase- 1 Scrap Recovery Line and the Phase-3 Pu-238 Oxide Conversion Line along with H-Canyon Frame Waste Recovery process. In addition, it also covers and describes utilizing the Phase-2 Np-237 Oxide Conversion Line, in conjunction with the H-Canyon Frames Process to restore the H-Canyon capability to process and recover Np-237 and Pu-238 from irradiated Np-237 targets and address potential synergies with other programs like recovery of Pu-244 and heavy isotopes of curium from other target material. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Continuous Air Monitor Operating Experience Review

Continuous air monitors (CAMs) are used to sense radioactive particulates in room air of nuclear facilities. CAMs alert personnel of potential inhalation exposures to radionuclides and can also actuate room ventilation isolation for public and environmental protection. This paper presents the results of a CAM operating experience review of the DOE Occurrence Reporting and Processing System (ORPS) database from the past 18 years. Regulations regarding these monitors are briefly reviewed. CAM location selection and operation are briefly discussed. Operating experiences reported by the U.S. Department of Energy and in other literature sources were reviewed to determine the strengths and weaknesses of these monitors. Power losses, human errors, and mechanical issues cause the majority of failures. The average “all modes” failure rate is 2.65E-05/hr. Repair time estimates vary from an average repair time of 9 hours (with spare parts on hand) to 252 hours (without spare parts on hand). These data should support the use of CAMs in any nuclear facility, including the National Ignition Facility and the international ITER experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of the Hydrofluoroether Cosolvent Structure in Acetonitrile-Based Solvate Electrolytes on the Li+ Solvation Structure and Li-S Battery Performance.

We evaluate hydrofluoroether (HFE) cosolvents with varying degrees of fluorination in the acetonitrile-based solvate electrolyte to determine the effect of the HFE structure on the electrochemical performance of the Li-S battery. Solvates or sparingly solvating electrolytes are an interesting electrolyte choice for the Li-S battery due to their low polysulfide solubility. The solvate electrolyte with a stoichiometric ratio of LiTFSI salt in acetonitrile, (MeCN)(2)-LiTFSI, exhibits limited polysulfide solubility due to the high concentration of LiTFSI. We demonstrate that the addition of highly fluorinated HFEs to the solvate yields better capacity retention compared to that of less fluorinated HFE cosolvents. Raman and NMR spectroscopy coupled with ab initio molecular dynamics simulations show that HFEs exhibiting a higher degree of fluorination coordinate to Li+ at the expense of MeCN coordination, resulting in higher free MeCN content in solution. However, the polysulfide solubility remains low, and no crossover of polysulfides from the S cathode to the Li anode is observed.

hydrofluoroether cosolvent↗

Reliability Considerations for the Operation of Large Accelerator User Facilities

The lecture provides an overview of considerations relevant for achieving highly reliable operation of accelerator based user facilities. The article starts with an overview of statistical reliability formalism which is followed by high reliability design considerations with examples. Finally, the article closes with operational aspects of high reliability such as preventive maintenance and spares inventory.

43 PARTICLE ACCELERATORS↗

Modeling Logistics and Supportability for Crewed Missions Beyond Low Earth Orbit

NASA’s future missions aim to establish a sustained human presence on the lunar surface and send humans to Mars. These missions will send crews farther from home than previous missions, limiting the opportunities for resupply missions. Additionally, the use of multiple launches and reusable elements will increase mission and campaign complexity. Logistics and supportability analysis evaluates the link between mission and system characteristics and key metrics such as logistics and spares mass and volume, crew time, and risk. As missions become increasingly complex and crews are logistically isolated for longer periods of time, logistics and supportability will become more powerful drivers of risk and cost and, therefore, more important considerations during system and mission development. When logistics and supportability are considered from the beginning of system and mission development, opportunities arise to create more efficient, lower-risk systems. Design choices made without detailed consideration of logistics and supportability have the potential to result in greater risks and increased costs as all options may not have been analyzed. This paper provides an overview of a methodology used for space mission logistics and supportability analysis, including key metrics, assumptions, and required inputs. Example applications of this methodology to explore the impacts of system architecture, dormancy, and synergies between lunar and Mars missions are also presented. Conducting these holistic analyses enables informed decision-making for mission planning and system design, which can help mitigate the risk of loss of mission, vehicle, or crew. Using the knowledge of historical missions, experiences gained on the lunar surface, and logistics and supportability analyses, NASA can examine and optimize supportability characteristics for safer and more effective operations for future lunar and Mars missions.

Supportability↗

Modeling Logistics and Supportability for Crewed Missions Beyond Low Earth Orbit

NASA’s future missions aim to establish a sustained human presence on the lunar surface and send humans to Mars. These missions will send crews farther from home than previous missions, limiting the opportunities for resupply missions. Additionally, the use of multiple launches and reusable elements will increase mission and campaign complexity. Logistics and supportability analysis evaluates the link between mission and system characteristics and key metrics such as logistics and spares mass and volume, crew time, and risk. As missions become increasingly complex and crews are logistically isolated for longer periods of time, logistics and supportability will become more powerful drivers of risk and cost and, therefore, more important considerations during system and mission development. When logistics and supportability are considered from the beginning of system and mission development, opportunities arise to create more efficient, lower-risk systems. Design choices made without detailed consideration of logistics and supportability have the potential to result in greater risks and increased costs as all options may not have been analyzed. This paper provides an overview of a methodology used for space mission logistics and supportability analysis, including key metrics, assumptions, and required inputs. Example applications of this methodology to explore the impacts of system architecture, dormancy, and synergies between lunar and Mars missions are also presented. Conducting these holistic analyses enables informed decision-making for mission planning and system design, which can help mitigate the risk of loss of mission, vehicle, or crew. Using the knowledge of historical missions, experiences gained on the lunar surface, and logistics and supportability analyses, NASA can examine and optimize supportability characteristics for safer and more effective operations for future lunar and Mars missions.

Supportability↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

As we know, power transformers are the most critical asset of the transmission network. Although highly reliable, they still can fail prematurely or ultimately retire at the end of their service life. In today’s design practices, transformers are tailored to their specific application and therefore cannot replace each other unless identical. Additionally, they provide minimal support to the grid operation and therefore limit the grid flexibility and resiliency when facing severe conditions. In this presentation, we will introduce the concept of flexible power transformer and demonstrate how one single unit can serve as a spare to multiple units in a given fleet, allow to control the power flow between transformers or lines operating in parallel and ultimately be used to limit subsequent faults in transmission lines. We will also introduce the world’s first prototype in operation, a 60MVA, 165kV flexible autotransformer.

flexible power transformer, autotransformer, varia↗

Multiple mechanisms generate a universal scaling with dissipation for the air-water gas transfer velocity

A large corpus of field and laboratory experiments support the finding that the water side transfer velocity kL of sparingly soluble gases near air-water interfaces scales as k L ~(νε) 1/4 , where ν is the kinematic water viscosity and ε is the mean turbulent kinetic energy dissipation rate. Originally predicted from surface renewal theory, this scaling appears to hold for marine and coastal systems and across many environmental conditions. It is shown that multiple approaches to representing the effects of turbulence on kL lead to this expression when the Kolmogorov microscale is assumed to be the most efficient transporting eddy near the interface. The approaches considered range from simplified surface renewal schemes with distinct models for renewal durations, scaling and dimensional considerations, and a new structure function approach derived using analogies between scalar and momentum transfer. The work offers a new perspective as to why the aforementioned 1/4 scaling is robust.

54 ENVIRONMENTAL SCIENCES↗

A Fiber-Based 3D Lithium Host for Lean Electrolyte Lithium Metal Batteries

3D hosts are promising to extend the cycle life of lithium metal anodes but have rarely been implemented with lean electrolytes thus impacting the practical cell energy density. To overcome this challenge, a 3D host that is lightweight and easy to fabricate with optimum pore size that enables full utilization of its pore volume, essential for lean electrolyte operations, is reported. The host is fabricated by casting a VGCF (vapor-grown carbon fiber)-based slurry loaded with a sparingly soluble rubidium nitrate salt as an additive. The network of fibers generates uniform pores of ≈3 µm in diameter with a porosity of 80%, while the nitrate additive enhances lithiophilicity. This 3D host delivers an average coulombic efficiency of 99.36% at 1 mA cm -2 and 1 mAh cm -2 for over 860 cycles in half-cell tests. Full cells containing an anode with 1.35-fold excess lithium paired with LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) cathodes exhibit capacity retention of 80% over 176 cycles at C/2 under a lean electrolyte condition of 3 g Ah -1 . This work provides a facile and scalable method to advance 3D lithium hosts closer to practical lithium-metal batteries.

36 MATERIALS SCIENCE↗

Cognitively defined Alzheimer's dementia subgroups have distinct atrophy patterns

We sought to determine structural magnetic resonance imaging (MRI) characteristics across subgroups defined based on relative cognitive domain impairments using data from the Alzheimer's Disease Neuroimaging Initiative (ADNI) and to compare cognitively defined to imaging-defined subgroups. We used data from 584 people with Alzheimer's disease (AD) (461 amyloid positive, 123 unknown amyloid status) and 118 amyloid-negative controls. We used voxel-based morphometry to compare gray matter volume (GMV) for each group compared to controls and to AD-Memory. There was pronounced bilateral lower medial temporal lobe atrophy with relative cortical sparing for AD-Memory, lower left hemisphere GMV for AD-Language, anterior lower GMV for AD-Executive, and posterior lower GMV for AD-Visuospatial. Formal asymmetry comparisons showed substantially more asymmetry in the AD-Language group than any other group (p = 1.15 × 10 -10 ). For overlap between imaging-defined and cognitively defined subgroups, AD-Memory matched up with an imaging-defined limbic predominant group. MRI findings differ across cognitively defined AD subgroups.

60 APPLIED LIFE SCIENCES↗

Detection of biological uranium reduction using magnetic resonance

The conversion of soluble uranyl ions (UOurn:x-wiley:00063592:media:BIT24369:tex2gif-stack-1) by bacterial reduction to sparingly soluble uraninite (UO2(s)) is being studied as a way of immobilizing subsurface uranium contamination. Under anaerobic conditions, several known types of bacteria including iron and sulfate reducing bacteria have been shown to reduce U (VI) to U (IV). Experiments using a suspension of uraninite (UO2(s)) particles produced by Shewanella putrefaciens CN32 bacteria show a dependence of both longitudinal (T1) and transverse (T2) magnetic resonance (MR) relaxation times on the oxidation state and solubility of the uranium. Gradient echo and spin echo MR images were compared to quantify the effect caused by the magnetic field fluctuations (equation image) of the uraninite particles and soluble uranyl ions. Since the precipitate studied was suspended in liquid water, the effects of concentration and particle aggregation were explored. A suspension of uraninite particles was injected into a polysaccharide gel, which simulates the precipitation environment of uraninite in the extracellular biofilm matrix. A reduction in the T2 of the gel surrounding the particles was observed. Tests done in situ using three bioreactors under different mixing conditions, continuously stirred, intermittently stirred, and not stirred, showed a quantifiable T2 magnetic relaxation effect over the extent of the reaction.

54 ENVIRONMENTAL SCIENCES↗

Electron Bifurcation Makes the Puzzle Pieces Fall Energetically into Place in Methanogenic Energy Conservation

Microbial life has evolved a wide range of metabolisms exploiting in many cases unanticipated suites of oxidation-reduction reactions to generate energy. Although many of these suites of reactions don't allow these microbes to enjoy the same quality of energetic life that we enjoy via respiration/oxidative phosphorylation, it has conferred the ability for life to exploit almost any oxidation-reduction reaction. We find in many of these cases when energy is sparing, the difference between life and death may be conserving the maximal amount of energy and minimizing loss of free energy through heat.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A review of stereotactic body radiotherapy – is volumetric modulated arc therapy the answer?

Stereotactic body radiotherapy (SBRT) is a high precision radiotherapy technique used for the treatment of small to moderate extra-cranial tumours. Early studies utilising SBRT have shown favourable outcomes. However, major disadvantages of static field SBRT include long treatment times and toxicity complications. Volumetric modulated arc therapy (VMAT) and intensity modulated radiotherapy (IMRT) may potentially mitigate these disadvantages. This review aims to assess the feasibility of emerging VMAT and IMRT-based SBRT treatment techniques and qualify which offers the best outcome for patients, whilst identifying any emerging and advantageous SBRT planning trends. A review and synthesis of data from current literature up to September 2013 was conducted on EMBASE, Medline, PubMed, Science Direct, Proquest central, Google Scholar and the Cochrane Database of Systematic reviews. Only full text papers comparing VMAT and or IMRT and or Static SBRT were included. Ten papers were identified that evaluated the results of VMAT/IMRT SBRT. Five related to medically inoperable stage 1 and 2 non-small-cell lung cancer (NSCLC), three to spinal metastasis, one related to abdominal lymph node malignancies, with the final one looking at pancreatic adenocarcinoma. Overall treatment times with VMAT were reduced by 66–70% for lung, 46–58% for spine, 42% and 21% for lymph node and pancreatic metastasis respectively, planning constraints were met with several studies showing improved organs at risk sparing with IMRT/VMAT to static SBRT. Both IMRT and VMAT were able to meet all planning constraints in the studies reviewed, with VMAT offering the greatest treatment efficiency. Early clinical outcomes with VMAT and IMRT SBRT have demonstrated excellent local control and favourable survival outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing four volumetric modulated arc therapy beam arrangements for the treatment of early-stage prostate cancer

This study compared four different volumetric modulated arc therapy (VMAT) beam arrangements for the treatment of early-stage prostate cancer examining plan quality and the impact on a radiotherapy department's resources. Twenty prostate cases were retrospectively planned using four VMAT beam arrangements (1) a partial arc (PA), (2) one arc (1A), (3) one arc plus a partial arc (1A + PA) and (4) two arcs (2A). The quality of the dose distributions generated were compared by examining the overall plan quality, the homogeneity and conformity to the planning target volume (PTV), the number of monitor units and the dose delivered to the organs at risk. Departmental resources were considered by recording the planning time and beam delivery time. Each technique produced a plan of similar quality that was considered adequate for treatment; though some differences were noted. The 1A, 1A + PA and 2A plans demonstrated a better conformity to the PTV which correlated to improved sparing of the rectum in the 60–70 Gy range for the 1A + PA and 2A techniques. The time needed to generate the plans was different for each technique ranging from 13.1 min for 1A + PA to 17.8 min for 1A. The PA beam delivery time was fastest with a mean time of 0.9 min. Beam-on times then increased with an increase in the number of arcs up to an average of 2.2 min for the 2A technique. Which VMAT technique is best suited for clinical implementation for the treatment of prostate cancer may be dictated by the individual patient and the availability of departmental resources.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the dosimetric impact of applying flattening filter-free beams in intensity-modulated radiotherapy for early-stage upper thoracic carcinoma of oesophagus

Flattening filter-free (FFF) radiation beams have recently become clinically available on modern linear accelerators in radiation therapy. This study aimed to evaluate the dosimetric impact of using FFF beams in intensity-modulated radiotherapy (IMRT) for early-stage upper thoracic oesophageal cancer. Eleven patients with primary stage upper thoracic oesophageal cancer were recruited. For each patient, two IMRT plans were computed using conventional beams (Con-P) and FFF beams (FFF-P), respectively. Both plans employed a five-beam arrangement and were prescribed with 64 Gy to (planning target volume) PTV1 and 54 Gy to PTV2 in 32 fractions using 6 MV photons. The dose parameters of the target volumes and organs at risks (OARs), and treatment parameters including the monitor units (MU) and treatment time (TT) for Con-P and FFF-P were recorded and compared. The mean D{sub 5} of PTV1 and PTV2 were higher in FFF-P than Con-P by 0.4 Gy and 0.3 Gy, respectively. For the OARs, all the dose parameters did not show significant difference between the two plans except the mean V{sub 5} and V{sub 10} of the lung in which the FFF-P was lower (46.7% vs. 47.3% and 39.1% vs. 39.6%, respectively). FFF-P required 54% more MU but 18.4% less irradiation time when compared to Con-P. The target volume and OARs dose distributions between the two plans were comparable. However, FFF-P was more effective in sparing the lung from low dose and reduced the mean TT compared with Con-P. Long-term clinical studies are suggested to evaluate the radiobiological effects of FFF beams.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prolonged survival in secondary glioblastoma following local injection of targeted alpha therapy with 213 Bi-substance P analogue

Background Glioblastoma multiforme (GBM), the most common malignant brain tumor, mainly manifests as a primary de novo and less frequently as a secondary glial neoplasm. GBM has been demonstrated to overexpress the NK-1 receptor and substance P can be used as a ligand for targeted therapy. Alpha emitters, e.g. 213 Bi, that deposit their high energy within a short range allow the selective irradiation of tumor cells while sparing adjacent neuronal structures. Material and methods Among 50 glioma patients of different subtypes that have to date been treated with targeted alpha therapy at the Medical University Warsaw, we report here the data on nine patients with secondary GBM. Following surgery, chemo- and radiotherapy, recurrent GBM was treated by intracavitary injection of 1–6 doses of 0.9–2.3 GBq 213 Bi- DOTA-[Thi 8 ,Met(O 2 ) 11 ]-substance P ( 213 Bi-DOTA-SP) in 2-month intervals. 68 Ga-DOTA-[Thi 8 ,Met(O 2 ) 11 ]-substance P ( 68 Ga-DOTA-SP) was coinjected with the therapeutic doses to assess biodistribution using PET/CT. Therapeutic response was monitored with MRI. Results Treatment with activities ranging from 1.4 to 9.7 (median 5.8) GBq 213 Bi- DOTA-SP was well tolerated with only mild transient adverse reactions, mainly headaches due to a transient perfocal edema reaction. The median progression free survival and overall survival time following the initiation of alpha therapy was 5.8 and 16.4 months, respectively. The median overall survival time from the first diagnosis was 52.3 months. Two out of nine patients are still alive 39 and 51 months, respectively, after the initiation of the therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI of testicular malignancies

Although testicular carcinoma represents approximately only 1% of solid neoplasms in men, it is the most common malignancy between young men. The two main histologic categories are testicular germ cell tumors (TGCTs), including seminomas and nonseminomas, accounting for 90–95% of testicular neoplasms and sex cord-stromal tumors. Scrotal MRI, including a multiparametric protocol, has been proposed as a valuable supplemental imaging technique in the investigation of testicular pathology. Recently, the Scrotal and Penile Imaging Working Group appointed by the board of the European Society of Urogenital Radiology has produced recommendations on when to perform scrotal MRI. Regarding intratesticular masses, MRI of the scrotum may be used for their characterization, when US findings are indeterminate and for local staging of TGCTs, when organ-sparing surgery is planned. Differentiation between seminomas and nonseminomas is possible based on MRI features, when clinically needed. Scrotal MRI may also help in differentiating between TGCTs and nongerm cell tumors. Functional information based on diffusion-weighted imaging and dynamic contrast-enhanced MRI data improve testicular mass lesion characterization. Preliminary observations on diffusion tensor imaging, magnetization transfer imaging, and proton MR spectroscopy bring about new data in the understanding of testicular microstructure and pathophysiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimation of split renal function using different volumetric methods: inter- and intraindividual comparison between MRI and CT

Purpose: This study aims to determine whether contrast-enhanced (CE)-magnetic resonance imaging (MRI) is comparable to CE-computed tomography (CT) for estimation of split renal function (SRF). For this purpose, two different kidney volumetry methods, the renal cortex volumetry (RCV) and modified ellipsoid volume (MELV), are compared for both acquisition types (CT vs. MRI) with regard to accuracy and reliability, subsequently referred to as RCV{sub CT}/RCV{sub MRI} and MELV{sub CT}/MELV{sub MRI}. Methods: This retrospective study included 29 patients (18 men and 11 women; mean age 62.8 ± 12.4 years) who underwent CE-MRI and CE-CT of the abdomen within a period of 3 months. Two independent readers (R1/R2) performed RCV and MELV in all datasets with corresponding semiautomated software tools. RCV was performed with datasets in the arterial phase and MELV in the venous phase. Statistics were calculated using one-way ANOVA, two-tailed Student’s t test, Pearson´s correlation, and Bland–Altman plots with p ≤ 0.05 being considered statistically significant. Results: In all datasets, SRF was almost identical for both volumetry methods with a mean difference of < 1%. Bland–Altman analysis comparing RCV in CT and MRI showed very good agreement for R1/R2. Interreader agreement was strong for RCV{sub CT} and good for RCV{sub MRI} (r = 0.89; r = 0.69). MELV{sub CT/MRI} interreader agreement was only moderate (r = 0.54; r = 0.50) with a high range of values. Intrareader agreement was excellent for all measurements, except MELV{sub MRI} which showed a high mean bias and range of values (RCV{sub CT}: r = 0.93, RCV{sub MRI}: r = 0.98, MELV{sub CT}: r = 0.89, MELV{sub MRI}: r = 0.54). Conclusion: Renal volumetric estimates of SRF are almost as accurate and reliable with CE-MRI as with CE-CT using RCV method. In distinction, the calculation of SRF using MELV was inferior to RCV with respect to accuracy and reliability. Thus, RCV method is recommended to estimate SRF, primarily using CT datasets. However, RCV with MRI datasets for kidney volumetry allows for comparable accuracy and reliability while sparing patients and healthy donors of unnecessary radiation exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗